Search NASA⌕ Search

SEARCH · Search NASA

Results for “hypercubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Identification of Distribution of Elastic Constants of SiC/SiC Braided Tubes

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiCf/SiCm) composite tubes due to their superior mechanical properties. There are many parameters in the manufacturing of SiCf/SiCm composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. A sensitivity analysis will be carried out to determine the dominant parameters among the abovementioned ones. We intend to determine the variability in elastic constants of SiCf/SiCm composite tubes considering the variability in dominant parameters. A chosen number of combinations of dominant variables will be sampled through Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in circumferential and longitudinal direction, Poisson's ratio and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used a surrogate to FE analysis. once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The variability can be calculated based on MCS-generated data which will be presented at the conference.

42 ENGINEERING↗

A cloud computing approach to massively-parallel distributed stochastic optimization with application to geomechanical reservoir characterization

Many search strategies used to optimize parameters during hydrologic model calibration are inherently limited in that simulations must be performed sequentially in order for the algorithm to converge. As a result, the overall time required to reach a solution increases linearly with the number of steps necessary. In contrast, sampling strategies that attempt to approximate the posterior distribution of the parameters do not require the model simulations to be run in sequence and therefore invite the use of a massively parallel approach across heterogeneous computing environments. We apply a cloud computing methodology to this problem where a head node running on Amazon Web Services continuously produces candidate models that are distributed to arbitrary compute environments to run the simulation, in our case Clemson’s Palmetto cluster computer. Thus the time required to obtain a sufficient number of samples to produce an adequate approximation of the posterior distribution of the parameters is limited by the number of available compute sites. Monte Carlo sampling of the posterior space would be duplicative and inefficient, thus we combine Latin hypercube methods with genetic algorithms to ensure that no large regions of the parameter space are left unexplored, and that high probability regions are investigated thoroughly. We independently assess the fit to different types of data sets without the need to construct a single objective function. Sets of Pareto optimal models are particularly valuable when the quality and information content of data is poorly known or conceptual model errors exist in our simulation. We illustrate our approach for a problem where in situ strain data are used to calibrate the parameters of an oil reservoir in the Avant oil field in Oklahoma. We use well injection and shut-in to stress a deep (500m) confined formation, and observe the geomechanical response using borehole strainmeters installed in the shallow subsurface (30m). These data were then used to calibrate the poroelastic properties of the reservoir and caprock along with the geometry of an elliptic channel associated with the formation. Using our approach we are able to identify issues with model error as well as substantial tradeoffs that occur within the parameters.

inversion, stochastic, geomechanics, poroelastic, ↗

Uncertainty Quantification and Sensitivity Analysis for Quantitative Risk Assessments of Hydrogen Infrastructure

Typical QRAs provide deterministic estimates and understanding of risks posed but are constructed using significant assumptions and uncertainties due to limited data availability and historical momentum of using nominal estimates. This report presents a hydrogen QRA analysis using HyRAM+ that incorporates uncertainty with Latin hypercube sampling and sensitivity analysis using linear regression.

08 HYDROGEN↗

Evaluating large scale aqueous organic redox flow battery performance with a hybrid numerical and machine learning framework

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low-capacity degradation in 10 cm$^2$ cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier to commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm$^2$ DHP-based AORFB by combining a physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. Such combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Toward a more robust variance-based global sensitivity analysis of model outputs

Global sensitivity analysis (GSA) measures the variation of a model output as a function of the variations of the model inputs given their ranges. In this paper we consider variance-based GSA methods that do not rely on certain assumptions about the model structure such as linearity or monotonicity. These variance-based methods decompose the output variance into terms of increasing dimensionality called 'sensitivity indices', first introduced by Sobol' [25]. Sobol' developed a method of estimating these sensitivity indices using Monte Carlo simulations. McKay [13] proposed an efficient method using replicated Latin hypercube sampling to compute the 'correlation ratios' or 'main effects', which have been shown to be equivalent to Sobol's first-order sensitivity indices. Practical issues with using these variance estimators are how to choose adequate sample sizes and how to assess the accuracy of the results. This paper proposes a modified McKay main effect method featuring an adaptive procedure for accuracy assessment and improvement. We also extend our adaptive technique to the computation of second-order sensitivity indices. Details of the proposed adaptive procedure as wells as numerical results are included in this paper.

99 GENERAL AND MISCELLANEOUS↗

Systems Analysis Programs for Hands-On Integrated Reliability Evaluations (SAPHIRE) Technical Reference

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer (PC) running the Microsoft Windows? operating system. Herein information is provided on the principles used in the construction and operation of Version 6.0 and 7.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, cut set "recovery," end state manipulation, and use of "compound events."

99 GENERAL AND MISCELLANEOUS↗

Optimization of the Area 5 Radioactive Waste Management Site Closure Cover

The U.S. Department of Energy Manual DOE M 435.1-1, “Radioactive Waste Management Manual,” requires that performance assessments demonstrate that releases of radionuclides to the environment are as low as reasonably achievable (ALARA). Quantitative cost benefit analysis of radiation protection options is one component of the ALARA process. This report summarizes a quantitative cost benefit analysis of closure cover thickness for the Area 5 Radioactive Waste Management Site (RWMS) on the Nevada Test Site. The optimum cover thickness that maintains doses ALARA is shown to be the thickness with the minimum total closure cost. Total closure cost is the sum of cover construction cost and the health detriment cost. Cover construction cost is estimated based on detailed cost estimates for closure of the 92-acre Low-Level Waste Management Unit (LLWMU). The health detriment cost is calculated as the product of collective dose and a constant monetary value of health detriment in units of dollars per unit collective dose. Collective dose is the sum of all individual doses in an exposed population and has units of person-sievert (Sv). Five discrete cover thickness options ranging from 2.5 to 4.5 meters (m) (8.2 to 15 feet [ft]) are evaluated. The optimization was subject to the constraints that (1) options must meet all applicable regulatory requirements and that (2) individual doses be a small fraction of background radiation dose. Total closure cost is found to be a monotonically increasing function of cover thickness for the 92-ac LLWMU, the Northern Expansion Area, and the entire Area 5 RWMS. The cover construction cost is orders of magnitude greater than the health detriment cost. Two-thousand Latin hypercube sampling realizations of the relationship between total closure cost and cover thickness are generated. In every realization, the optimum cover thickness is 2.5 m (8.2 ft) for the 92-ac Low-Level Waste Management Unit, the Northern Expansion Area, and the entire Area 5 RWMS. The conclusions of the optimization are found to be insensitive to all input parameters, the monetary value of the health detriment over a range of values from $200,000 to $15,000,000 per person-Sv, and the period of integration of collective dose. A 2.5 m (8.2 ft) closure cover at the Area 5 RWMS can meet all applicable regulatory requirements and maintain radionuclide releases ALARA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of Different Operation Conditions and Geological Formation Characteristics on CO2 Sequestration in Citronelle Dome, Alabama

Major concerns of carbon dioxide (CO2) sequestration in subsurface formations are knowledge of the well injectivity and gas storage capacity of the formation, the CO2 pressure and saturation plume extensions during and after injection, and the risks associated with CO2 leakage and fault reactivation. Saline reservoirs are considered as one of the target formations for CO2 sequestration through structural, residual, dissolution, and mineral trapping mechanisms. The boundary condition of the saline reservoir dictates the pressure and saturation plume extension of the injected supercritical CO2 that could expand over large distances. This can lead to sources of risk, e.g., leakage and/or fault reactivation due to presence of wells, thief zones, and geological discontinuities. Therefore, there is a critical need to develop a model that describes how risk-related performance metrics (i.e., the CO2 saturation plume size, the pressure differential plume area, and the pressure differential at specific locations) vary as a function of the size of injection, time following injection, injection operations, and geologic environment. In this study, a systematic reservoir modeling studies of anthropogenic CO2 sequestration in Citronelle dome, Alabama, was performed where all relevant scenarios and conditions to address the questions of the saturation and pressure plume size in the area of review (AoR) and post-injection site care (PISC) are considered. The objective for this study was firstly to systematically simulate CO2 sequestration, i.e., saturation dynamics, and pressure behavior over a range of operational and geological conditions and to derive conclusions about the factors influencing saturation and pressure plume size, post-injection behavior, and the risk associated with them, by developing third-generation reduced order models (ROMs) for reservoir behavior. Finally, to assess the uncertainty associated with our studies, Latin Hypercube Sampling (LHS) together with an experimental design technique, i.e., Plackett–Burman design, was used. Application of Pareto charts and respond surfaces enabled us to determine the most important parameters impacting saturation and pressure plume sizes and to quantify the auto- and cross-correlation among different parameters in both history-matched and upscaled models.

58 GEOSCIENCES↗

The Mira-Titan Universe. III. Emulation of the Halo Mass Function

We construct an emulator for the halo mass function over group and cluster mass scales for a range of cosmologies, including the effects of dynamical dark energy and massive neutrinos. The emulator is based on the recently completed Mira-Titan Universe suite of cosmological N-body simulations. The main set of simulations spans 111 cosmological models with 2.1 Gpc boxes. We extract halo catalogs in the redshift range z = [0.0, 2.0] and for masses M-200c >= 10(13)M(circle dot)/h. The emulator covers an eight-dimensional hypercube spanned by {Omega(m)h(2), Omega(b)h(2), Omega(nu)h(2), sigma(8), h, n(s), w(0), w(a)}; spatial flatness is assumed. We obtain smooth halo mass functions by fitting piecewise second-order polynomials to the halo catalogs and employ Gaussian process regression to construct the emulator while keeping track of the statistical noise in the input halo catalogs and uncertainties in the regression process. For redshifts z less than or similar to 1, the typical emulator precision is better than 2% for 10(13)-10(14)M(circle dot)/h and <10<^> M similar or equal to 101(circle dot)(54)/h. For comparison, fitting functions using the traditional universal form for the halo mass function can be biased at up to 30% at M similar or equal to 10(144)M(circle dot)/h for z = 0. Our emulator is publicly available at https://github.com/SebastianBocquet/MiraTitanHMFemulator.

cosmology: theory↗

An extensible perturbed parameter ensemble for the Community Atmosphere Model version 6

This paper documents the methodology and preliminary results from a perturbed parameter ensemble (PPE) technique, where multiple parameters are varied simultaneously and the parameter values are determined with Latin hypercube sampling. This is done with the Community Atmosphere Model version 6 (CAM6), the atmospheric component of the Community Earth System Model version 2 (CESM2). We apply the PPE method to CESM2–CAM6 to understand climate sensitivity to atmospheric physics parameters. The initial simulations vary 45 parameters in the microphysics, convection, turbulence and aerosol schemes with 263 ensemble members. These atmospheric parameters are typically the most uncertain in many climate models. Control simulations and targeted simulations to understand climate forcing due to aerosols and fast climate feedbacks are analyzed. The use of various emulators is explored in the multi-dimensional space mapping input parameters to output metrics. Parameter impacts on various model outputs, such as radiation, cloud and aerosol properties, are evaluated. Machine learning is also used to probe optimal parameter values against observations. Our findings show that PPE is a valuable tool for climate uncertainty analysis. Furthermore, by varying many parameters simultaneously, we find that many different combinations of parameter values can produce results consistent with observations, and thus careful analysis of tuning is important. The CESM2–CAM6 PPE is publicly available and extensible to other configurations to address questions of other model processes in the atmosphere and other model components (e.g., coupling to the land surface).

54 ENVIRONMENTAL SCIENCES↗

A flexible importance sampling method for integrating subgrid processes

Numerical models of weather and climate need to compute grid-box-averaged rates of physical processes such as microphysics. These averages are computed by integrating subgrid variability over a grid box. For this reason, an important aspect of atmospheric modeling is spatial integration over subgrid scales. The needed integrals can be estimated by Monte Carlo integration. Monte Carlo integration is simple and general but requires many evaluations of the physical process rate. To reduce the number of function evaluations, this paper describes a new, flexible method of importance sampling. It divides the domain of integration into eight categories, such as the portion that contains both precipitation and cloud, or the portion that contains precipitation but no cloud. It then allows the modeler to prescribe the density of sample points within each of the eight categories. The new method is incorporated into the Subgrid Importance Latin Hypercube Sampler (SILHS). The resulting method is tested on drizzling cumulus and stratocumulus cases. In the cumulus case, the sampling error can be considerably reduced by drawing more sample points from the region of rain evaporation.

54 ENVIRONMENTAL SCIENCES↗

Interpreting pulse-shape effects in pump-probe spectroscopies

The effect of the pulse-shape on pump-probe spectroscopies is examined for the simplest model of noninteracting fermions on an infinite-dimensional hypercubic lattice. The probe-modified density of states follows the time evolution of the pump and displays narrowing and Floquet-like sidebands at the pump maximum, whereas the photoelectron spectra are also strongly affected by the nonequilibrium occupation of the single-particle states due to the excitation from the pump. The nonequilibrium Raman cross section is derived, and the nonresonant one in both the A 1g and B 1g symmetries contains a number of peaks at the pump maximum, which can be attributed to an interference effect or Brillouin scattering off the time variations of the stress tensor. Both the "measured" occupation of single-particle states and the ratio of Stokes to anti-Stokes peaks are strongly modified by the probe-pulse width, which must be included in the interpretation of experimental results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards Fast and Accurate Predictions of Radio Frequency Power Deposition and Current Profile via Data-driven Modeling

Three machine learning techniques (multilayer perceptron, random forest, and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modeling and real-time control applications. The machine learning models use a database of 16,000+ GENRAY/CQL3D simulations for training, validation, and testing. Latin hypercube sampling methods ensure that the database covers the range of 9 input parameters ($n_{e0}$, $T_{e0}$, $I_p$, $B_t$, $R_0$, $n_{||}$, $Z_{eff}$, $V_{loop}$, $P_{LHCD}$) with sufficient density in all regions of parameter space. The surrogate models reduce the inference time from minutes to ~ms with high accuracy across the input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of Fire Severity Factors and Fire Non-Suppression Probabilities For A DOE Facility Fire PRA

Over a 12 month period, a fire PRA was developed for a DOE facility using the NUREG/CR-6850 EPRI/NRC fire PRA methodology. The fire PRA modeling included calculation of fire severity factors (SFs) and fire non-suppression probabilities (PNS) for each safe shutdown (SSD) component considered in the fire PRA model. The SFs were developed by performing detailed fire modeling through a combination of CFAST fire zone model calculations and Latin Hypercube Sampling (LHS). Component damage times and automatic fire suppression system actuation times calculated in the CFAST LHS analyses were then input to a time-dependent model of fire non-suppression probability. The fire non-suppression probability model is based on the modeling approach outlined in NUREG/CR-6850 and is supplemented with plant specific data. This paper presents the methodology used in the DOE facility fire PRA for modeling fire-induced SSD component failures and includes discussions of modeling techniques for: • Development of time-dependent fire heat release rate profiles (required as input to CFAST), • Calculation of fire severity factors based on CFAST detailed fire modeling, and • Calculation of fire non-suppression probabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BK using HYP-smeared staggered fermions in Nf = 2 + 1 unquenched QCD

We present results for the kaon mixing parameter B{sub K} calculated using HYP (hypercubic fat link)-smeared improved staggered fermions on the asqtad lattices generated by the MILC collaboration. We use three lattice spacings (a{approx} 0.12, 0.09 and 0.06 fm), ten different valence-quark masses (m {approx} m{sub s}/10-m{sub s}), and several light sea-quark masses in order to control the continuum and chiral extrapolations. We derive the next-to-leading order staggered chiral perturbation theory (SChPT) results necessary to fit our data, and use these results to do extrapolations based both on SU(2) and SU(3) SChPT. The SU(2) fitting is particularly straightforward because parameters related to taste breaking and matching errors appear only at next-to-next-to-leading order. We match to the continuum renormalization scheme [naive dimensional regularization (NDR)] using one-loop perturbation theory. Our final result is from the SU(2) analysis, with the SU(3) result providing a (less accurate) cross check. We find B{sub K}(NDR, {mu} = 2 GeV) = 0.529 {+-} 0.009 {+-} 0.032 and B{sub K} = B{sub K}(RGI) = 0.724 {+-} 0.012 {+-} 0.043, where the first error is statistical and the second systematic. The error is dominated by the truncation error in the matching factor. Our results are consistent with those obtained using valence domain-wall fermions on lattices generated with asqtad or domain-wall sea quarks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Is submodularity testable?

We initiate the study of property testing of submodularity on the boolean hypercube. Submodular functions come up in a variety of applications in combinatorial optimization. For a vast range of algorithms, the existence of an oracle to a submodular function is assumed. But how does one check if this oracle indeed represents a submodular function? Consider a function f: {l_brace}0, 1{r_brace}{sup n} {yields} R. The distance to submodularity is the minimum fraction of values of f that need to be modified to make f submodular. If this distance is more than {epsilon} > 0, then we say that f is {epsilon}-far from being submodular. The aim is to have an efficient procedure that, given input f that is {epsilon}-far from being submodular, certifies that f is not submodular. We analyze a very natural tester for this problem, and prove that it runs in subexponential time. This gives the first non-trivial tester for submodularity. On the other hand, we prove an interesting lower bound (that is, unfortunately, quite far from the upper bound) suggesting that this tester cannot be very efficient in terms of {epsilon}. This involves non-trivial examples of functions which are far from submodular and yet do not exhibit too many local violations. We also provide some constructions indicating the difficulty in designing a tester for submodularity. We construct a partial function defined on exponentially many points that cannot be extended to a submodular function, but any strict subset of these values can be extended to a submodular function.

99 GENERAL AND MISCELLANEOUS↗

SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Convergence of the Uncertainty Results

This paper describes the convergence of MELCOR Accident Consequence Code System, Version 2 (MACCS2) probabilistic results of offsite consequences for the uncertainty analysis of the State-of-the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout scenario at the Peach Bottom Atomic Power Station. The consequence metrics evaluated are individual latent-cancer fatality (LCF) risk and individual early fatality risk. Consequence results are presented as conditional risk (i.e., assuming the accident occurs, risk per event) to individuals of the public as a result of the accident. In order to verify convergence for this uncertainty analysis, as recommended by the Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards, a ‘high’ source term from the original population of Monte Carlo runs has been selected to be used for: (1) a study of the distribution of consequence results stemming solely from epistemic uncertainty in the MACCS2 parameters (i.e., separating the effect from the source term uncertainty), and (2) a comparison between Simple Random Sampling (SRS) and Latin Hypercube Sampling (LHS) in order to validate the original results obtained with LHS. Three replicates (each using a different random seed) of size 1,000 each using LHS and another set of three replicates of size 1,000 using SRS are analyzed. The results show that the LCF risk results are well converged with either LHS or SRS sampling. The early fatality risk results are less well converged at radial distances beyond 2 miles, and this is expected due to the sparse data (predominance of “zero” results).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗