Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Koshti, Ajay M.↗

Plug-and-Play Priors for Bright Field Electron Tomography and Sparse Interpolation

Many material and biological samples in scientific imaging are characterized by nonlocal repeating structures. These are studied using scanning electron microscopy and electron tomography. Sparse sampling of individual pixels in a two-dimensional image acquisition geometry, or sparse sampling of projection images with large tilt increments in a tomography experiment, can enable high speed data acquisition and minimize sample damage caused by the electron beam. In this paper, we present an algorithm for electron tomographic reconstruction and sparse image interpolation that exploits the nonlocal redundancy in images. We adapt a framework, termed plug-and-play priors, to solve these imaging problems in a regularized inversion setting. The power of the plug-and-play approach is that it allows a wide array of modern denoising algorithms to be used as a “prior model” for tomography and image interpolation. We also present sufficient mathematical conditions that ensure convergence of the plug-and-play approach, and we use these insights to design a new nonlocal means denoising algorithm. Finally, we demonstrate that the algorithm produces higher quality reconstructions on both simulated and real electron microscope data, along with improved convergence properties compared to other methods.

47 OTHER INSTRUMENTATION↗

Mechanical behavior of bimetallic stainless steel and gray cast iron repairs via directed energy deposition additive manufacturing

The utility of gray cast iron in engine components remains tied to the mechanical performance and cost. Repair and remanufacturing of castings offer economical and sustainable benefits; however, high thermal input from traditional fusion-based welding is unable to restore the original mechanical quality owing to brittle microstructures and porosity formed in situ. Directed energy deposition (DED) is an additive manufacturing method that has received considerable interest for repairs owing to the highly controllable nature of the process. Despite this, few works have connected the effect of DED parameters on actual interfacial strength. Consequently, distinct DED parameter combinations were identified to maximize the strength and fatigue life of the repaired cast iron. Further, high speed melt pool imaging and residual stress measurements are provided to aid in the understanding of the metallurgical quality and strength seen in these structures. In general, higher scanning speeds and lower thermal gradients promoted comparable tensile strength to that of the original gray cast iron. The results presented here provide a foundation to tune in the DED process to generate the required mechanical quality as a starting point for future process advancements.

36 MATERIALS SCIENCE↗

Self-Healing Thermal Annealing: Surface Morphological Restructuring Control of GaN Nanorods

With advances in nanolithography and dry etching, top-down methods of nanostructuring have become a widely used tool for improving the efficiency of optoelectronics. These nano dimensions can offer various benefits to the device performance in terms of light extraction and efficiency, but often at the expense of emission color quality. Broadening of the target emission peak and unwanted yellow luminescence are characteristic defect-related effects due to the ion beam etching damage, particularly for III–N based materials. In this article we focus on GaN based nanorods, showing that through thermal annealing the surface roughness and deformities of the crystal structure can be “self-healed”. Correlative electron microscopy and atomic force microscopy show the change from spherical nanorods to faceted hexagonal structures, revealing the temperature-dependent surface morphology faceting evolution. The faceted nanorods were shown to be strain- and defect-free by cathodoluminescence hyperspectral imaging, micro-Raman, and transmission electron microscopy (TEM). In-situ TEM thermal annealing experiments allowed for real time observation of dislocation movements and surface restructuring observed in ex-situ annealing TEM sampling. This thermal annealing investigation gives new insight into the redistribution path of GaN material and dislocation movement post growth, allowing for improved understanding and in turn advances in optoelectronic device processing of compound semiconductors.

36 MATERIALS SCIENCE↗

Facile synthesis of CuSe nanoparticles and high-quality single-crystal two-dimensional hexagonal nanoplatelets with tunable near-infrared optical absorption

A rapid injection approach is used to synthesize the copper selenide nanoparticles and two-dimensional single crystal nanoplates. This technique excludes the use of toxic or expensive materials, increasing the availability of two-dimensional binary chalcogenide semiconductors. The structure of the nanocrystals has been studied and the possible formation mechanism of the nanoplates has been proposed. The optical absorption showed that the nanoplates demonstrated wide and tuneable absorption band in the visible and near infrared region. These nanoplates could be interesting for converting solar energy and for nanophotonic devices operating in the near infrared. - Graphical abstract: TEM images of the copper selenides nanoparticles and nanoplates synthesized at 180 °C for 0 min, 10 min, 60 min. And the growth mechanism of the copper selenide nanoplates via the “oriented attachment”. Display Omitted - Highlights: • CuSe nanoparticles and nanoplates are synthesized by a rapid injection approach. • CuSe band gap can be widely tuned simply by modifying the synthesized time. • Al{sup 3+} ions have a significant impact on the growth rate of the nanoplates. • Growth mechanism of the CuSe nanoplates is based on the “oriented attachment”.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Destructive Evaluation of Materials via Ultraviolet Spectroscopy

A document discusses the use of ultraviolet spectroscopy and imaging for the non-destructive evaluation of the degree of cure, aging, and other properties of resin-based composite materials. This method can be used in air, and is portable for field use. This method operates in reflectance, absorbance, and luminescence modes. The ultraviolet source is used to illuminate a composite surface of interest. In reflectance mode, the reflected response is acquired via the imaging system or via the spectrometer. The spectra are analyzed for organic compounds (conjugated organics) and inorganic compounds (semiconducting band-edge states; luminescing defect states such as silicates, used as adhesives for composite aerospace applications; and metal oxides commonly used as thermal coating paints on a wide range of spacecraft). The spectra are compared with a database for variation in conjugation, substitution, or length of molecule (in the case of organics) or band edge position (in the case of inorganics). This approach is useful in the understanding of material quality. It lacks the precision in defining the exact chemical structure that is found in other materials analysis techniques, but it is advantageous over methods such as nuclear magnetic resonance, infrared spectroscopy, and chromatography in that it can be used in the field to assess significant changes in chemical structure that may be linked to concerns associated with weaknesses or variations in structural integrity, without disassembly of or destruction to the structure of interest.

Pugel, Betsy↗

SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between the plans on CT-sim with assigned CT-number and the deformable SEMAR CT datasets.

60 APPLIED LIFE SCIENCES↗

Aberration corrected scanning transmission electron microscopy and electron energy loss spectroscopy studies of epitaxial Fe/MgO/(001)Ge heterostructures

Aberration correction in the scanning transmission electron microscope combined with electron energy loss spectroscopy allows simultaneous mapping of the structure, the chemistry and even the electronic properties of materials in one single experiment with spatial resolutions of the order of one Angstrom. Here the authors will apply these techniques to the characterization of epitaxial Fe/MgO/(001)Ge and interfaces with possible applications for tunneling junctions, and the authors will show that epitaxial MgO films can be grown on a (001)Ge substrates by molecular beam epitaxy and how it is possible to map the chemistry of interfaces with atomic resolution. Epitaxial growth of insulator oxides on semiconductors constitutes a key issue within the field of electronics, and a considerably large effort has been devoted to harness the growth of high-k oxides on Si. Ge, due to its high electronic and hole mobility, is a very interesting alternative as a potential substrate for future high performance complementary metal-oxide-semiconductor field-effect transistors. However, a major issue is to avoid the high resistivity at the source and drain contacts ensuing from the pinning of the Fermi level at the valence-band maximum. It has been suggested that this problem could be fixed by depositing a thin insulating tunneling barrier between the Ge substrate and the metal contacts. In this case, single crystal epitaxy would represent an additional benefit, since it would lead to a reduction of interfacial defects and improved performance of the tunneling barrier. MgO has been suggested to fulfill such requisites. Furthermore, MgO has been demonstrated to be a good substrate for epitaxial growth of transition metals thin films, such as Fe and Co, thus avoiding the potential problem of chemical reactivity with Ge. In such a scenario, epitaxial deposition of high quality MgO films on Ge substrates is highly desirable. But in addition, successful epitaxial growth of MgO on a semiconductor would also constitute a plus for applications in spintronics, since the injection of a spin polarized current from a ferromagnetic electrode to a non-magnetic semiconductor requires the presence of a potential barrier. MgO represents a convenient choice because the symmetry filtering properties at the interface with transition metals would allow an efficient spin filtering effect. For this approach to succeed, a suitable semiconducting substrate where MgO can be grown epitaxially must be found. And again, while GaAs and Si have been investigated for such role, Ge has not received much attention so far. In this study the authors report on the atomic resolution characterization of high quality interfaces in Fe/MgO/(001)Ge heterostructures. The study of the defects, the inhomogeneities and the interface structure of such junctions is a must to pave the way toward future applications. For this aim, the combination of scanning transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) is a most useful tool, since it allows these features to be probed with atomic resolution. Spherical aberration correction in the STEM allows for increased contrast, allowing even single atoms to be detected both in imaging and spectroscopy.

36 MATERIALS SCIENCE↗

ZnO-Au x Cu 1-x Alloy and ZnO-Au x Al 1-x Alloy Vertically Aligned Nanocomposites for Low-Loss Plasmonic Metamaterials

Hyperbolic metamaterials are a class of materials exhibiting anisotropic dielectric function owing to the morphology of the nanostructures. In these structures, one direction behaves as a metal, and the orthogonal direction behaves as a dielectric material. Applications include subdiffraction imaging and hyperlenses. However, key limiting factors include energy losses of noble metals and challenging fabrication methods. In this work, self-assembled plasmonic metamaterials consisting of anisotropic nanoalloy pillars embedded into the ZnO matrix are developed using a seed-layer approach. Alloys of Au x Al 1-x or Au x Cu 1-x are explored due to their lower losses and higher stability. Optical and microstructural properties were explored. The ZnO-Au x Cu 1-x system demonstrated excellent epitaxial quality and optical properties compared with the ZnO-Au x Al 1-x system. Both nanocomposite systems demonstrate plasmonic resonance, hyperbolic dispersion, low losses, and epsilon-near-zero permittivity, making them promising candidates towards direct photonic integration.

36 MATERIALS SCIENCE↗

Surface Modification of Polycrystalline Cu(In,Ga)Se2 Thin-Film Solar Cell Absorber Surfaces for PEEM Measurements

We present a thorough examination of the {micro}m-scale topography of Cu(In, Ga)Se{sub 2} ('CIGSe') thin-film solar cell absorbers using different microscopy techniques. We specifically focus on the efficacy of preparing smooth sample surfaces - by etching in aqueous bromine solution - for a spatially resolved study of their chemical and electronic structures using photoelectron emission microscopy (PEEM). The etching procedure is shown to reduce the CIGSe surface roughness from ca. 40 to 25 nm after 40s etching, resulting in an increase in the quality of the obtained PEEM images. Furthermore we find that the average observed grain size at the etched surfaces appears larger than at the unetched surfaces. Using a liftoff procedure, it is additionally shown that the backside of the absorber is flat but finely patterned, likely due to being grown on the finely-structured Mo back contact.

14 SOLAR ENERGY↗

SU-E-T-801: Verification of Dose Information Passed Through 3D-Printed Products

Purpose: When quality assurance (QA) of patient treatment beam is performed, homogeneous water equivalent phantom which has different structure from patient’s internal structure is normally used. In these days, it is possible to make structures which have same shapes of human organs with commercialization of 3D-printer. As a Result, structures with same shape of human organs made by 3D-printer could be used to test qualification of treatment beam with greater accuracy than homogeneous water phantom. In this study, we estimated the dose response of 3D-printer materials to test the probability as a humanoid phantom or new generation of compensator tool. Methods: The rectangular products with variety densities (50%, 75% and 100%) were made to verify their characteristics. The products for experiment group and solid water phantom and air for control group with 125 cubic centimeters were put on solid water phantom with enough thickness. CT image of two products were acquired to know their HU values and to know about their radiologic characteristics. 6MV beams with 500MU were exposed for each experiment. Doses were measured behind the 3D-printed products. These measured doses were compared to the results taken by TPS. Results: Absorbed dose penetrated from empty air is normalized to 100%. Doses measured from 6MV photon beams penetrated from 50%, 75% and 100% products were 99%, 96% and 84%, respectively. HU values of 50%, 75% and 100% products are about −910, −860 and −10. Conclusion: 3D-printer can produce structures which have similar characteristics with human organ. These results would be used to make similar phantoms with patient information. This work was supported by the Nuclear Safety Research Program (Grant No. 1305033 and 1403019) of the Korea Radiation Safety Foundation and the Nuclear Safety and Security Commission and Radiation Technology Development Program (2013M2A2A4027117) of the Republic of Korea.

60 APPLIED LIFE SCIENCES↗

Imaging local electric fields produced upon synchrotron X-ray exposure

Electron-hole separation following hard X-ray absorption during diffraction analysis of soft materials under cryogenic conditions produces substantial local electric fields visualizable by second harmonic generation (SHG) microscopy. Monte Carlo simulations of X-ray photoelectron trajectories suggest the formation of substantial local electric fields in the regions adjacent to those exposed to X-rays, indicating a possible electric-field-induced SHG (EFISH) mechanism for generating the observed signal. In studies of amorphous vitreous solvents, analysis of the SHG spatial profiles following X-ray microbeam exposure was consistent with an EFISH mechanism. Within protein crystals, exposure to 12-keV (1.033-angstrom) X-rays resulted in increased SHG in the region extending similar to 3 mu m beyond the borders of the X-ray beam. Moderate X-ray exposures typical of those used for crystal centering by raster scanning through an X-ray beam were sufficient to produce static electric fields easily detectable by SHG. The X-ray-induced SHG activity was observed with no measurable loss for longer than 2 wk while maintained under cryogenic conditions, but disappeared if annealed to room temperature for a few seconds. These results provide direct experimental observables capable of validating simulations of X-ray-induced damage within soft materials. In addition, X-ray-induced local fields may potentially impact diffraction resolution through localized piezoelectric distortions of the lattice.

Dettmar, Christopher M.↗

Advanced X-Ray Inspection of Reinforced Carbon Composite Materials on the Orbiter Leading Edge Structural Subsystem (LESS)

The post return-to-flight (RTF) inspection methodology for the Orbiter Leading Edge Structural Subsystem (LESS) is currently being defined. Numerous NDT modalities and techniques are being explored to perform the flight-to-flight inspections of the reinforced carbon/carbon (RCC) composite material for impact damage, general loss of mass in the bulk layers, or other anomalous conditions that would pose risk to safe return upon re-entry. It is possible to have an impact upon ascent that is not visually observable on the surface, yet causes internal damage. Radiographic testing may be a useful NDT technique for such occurrences. The authors have performed radiographic tests on full-sized mock samples of LESS hardware with embedded image quality phantoms. Digitized radiographic film, computed radiography and flat panel digital real-time radiography was acquired using a GE Eresco 200 x-ray tube, and Se-75 and Yb-169 radioisotopes.

Hernandez, Jose M.↗

AM metal substrates for inkjet-printing of smart devices

Highlights: • An experimental study to characterize 3D-printed metal substrates and their surfaces for inkjet-printing is presented. • Multilayer structures composed of an insulating layer and a superposed conductive layer, inkjet-printed onto various metallic substrates. • Characterization based on microscopic and Focused Ion Beam (FIB) images, profilometer and contact angle measurements of the substrates. • Microscopic images and four-point-probe resistance- and profilometer measurements to gain insight into the quality of the multilayer print. - Abstract: A study to characterize surface and structural properties of 3D-printed metal substrates for multilayer inkjet-printing is presented. Such substrates can enable and alleviate the fabrication of smart and functional packages, implants or spare parts. For the characterization, a multilayer structure composed of an insulating layer and a superposed conductive layer is inkjet-printed onto the various 3D-printed metallic substrates. The printing is done using equivalent settings for all substrates. The characterization is based on microscopic and Focused Ion Beam (FIB) images, as well as profilometer and contact angle measurements of the substrates. Furthermore, microscopic images and four-point-probe resistance- and profilometer measurements are carried out, to gain insight into the quality of the multilayer print. We show the diversity in surface and structural properties of 3D-printed substrates, also for those fabricated using the same process. Also, the 3D-printed samples exhibit different wettability properties than metals processed using standard processes. Finally, we can also demonstrate the suitability of selected substrates for inkjet-printing.

36 MATERIALS SCIENCE↗

Kinematic fixtures to enable multi-material printing and rapid non-destructive inspection during two-photon lithography

Here, two-photon lithography (TPL) is a polymerization based technique that enables additive manufacturing of millimeter scale parts with submicron features. TPL equipment is often based on retrofitted optical microscopes that lack precise registration capabilities. Consequently, slow and error-prone visual alignment to fiducials is necessary if registration to pre-existing features is required. Herein, we have designed, built, and tested precise kinematic fixtures that are repeatable to within ±315 nm (3σ value) and passively register the build surface to TPL equipment with an accuracy of ±1.7 μm. This enables one to sequentially print with multiple materials by building the structures directly on top of the kinematic fixtures. In addition, the same fixtures passively register to an X-ray computed tomography (CT) system to enable non-destructive 3D inspection that is integrated with the fabrication process. These fixtures (i) provide a practical means to handle micro-scale parts during non-destructive imaging, (ii) reduce the set-up time for X-ray CT from more than an hour to less than a few minutes, and (iii) eliminate operator uncertainty from the multi-material printing and imaging process. As such, these fixtures enable new printing and imaging functionalities that are critical for high-quality additive manufacturing of multi-material polymer parts with microscale and submicron features.

42 ENGINEERING↗

Evaluation of Radiation Dose and Image Quality for the Varian Cone Beam Computed Tomography System

Purpose: To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as 'new' and 'old' protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. Methods and Materials: A calibrated Farmer chamber and two standard cylindrical Perspex CT dosimetry phantoms with diameter of 16 cm (head phantom) and 32 cm (body phantom) were used to measure the weighted cone-beam computed tomography dose index (CBCTDIw) of the Varian CBCT system. The absorbed dose of different organs was measured in a female anthropomorphic phantom with thermoluminescent dosimeters (TLD) and the total effective dose was estimated according to International Commission on Radiological Protection (ICRP) Publication 103. The dose measurement and image quality were studied for head-and-neck and pelvic regions, and comparison was made between the new and old protocols. Results: The values of the new CBCTDIw head-and-neck and pelvic protocols were 36.6 and 29.4 mGy, respectively. The total effective doses from the new head-and-neck and pelvic protocols were 1.7 and 8.2 mSv, respectively. The absorbed doses of lens for the new 200{sup o} and old 360{sup o} head-and-neck protocols were 3.8 and 59.4 mGy, respectively. The additional secondary cancer risk from daily CBCT might be up to 2.8%. Conclusions: The new Varian CBCT provided volumetric information for image guidance with acceptable image quality and lower radiation dose. This imaging tool gave a better standard for patient daily setup verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three dimensional silicon photonic crystals fabricated by two photon phase mask lithography

We describe the fabrication of silicon three dimensional photonic crystals using polymer templates defined by a single step, two-photon exposure through a layer of photopolymer with relief molded on its surface. Here, the resulting crystals exhibit high structural quality over large areas, displaying geometries consistent with calculation. Spectroscopic measurements of transmission and reflection through the silicon and polymer structures reveal excellent optical properties, approaching properties predicted by simulations that assume ideal layouts.

36 MATERIALS SCIENCE↗

Demonstrating Advanced Sensors for In-Situ Monitoring Towards Qualification of Nuclear Relevant Components

The U.S. Department of Energy’s Office of Nuclear Energy Advanced Materials and Manufacturing Technologies (AMMT) program is pursuing qualification of laser powder bed fusion (LPBF) components for nuclear applications. A major focus of this effort is the use of in situ process monitoring and machine learning–based tools to establish real-time quality assurance. The primary objective of this report is to identify and evaluate the most relevant in situ sensor systems for LPBF, and to document the deployment of these systems across platforms critical to the AMMT program. This work demonstrates how in situ monitoring can detect process anomalies, track geometry-dependent flaws, and identify limiting combinations of processing parameters—particularly those related to energy density and complex geometries (e.g., overhanging structures). To support this goal, a diverse suite of sensor modalities was evaluated across LPBF platforms, including visible and near-infrared (NIR) imaging, fringe projection profilometry, long-wavelength infrared (LWIR) thermography, and high-speed photodiode/pyrometry systems. These sensor streams were integrated with Peregrine, a machine-agnostic software platform that, among other capabilities, can generate real-time process anomaly classification. This report documents sensor deployments on multiple AMMT flagship platforms, including the Concept Laser M2 and Renishaw AM400/AM250 systems. Calibration builds with complex, flaw-prone geometries such as unsupported overhangs, stepped features, and thin walls, were used to evaluate how well Peregrine and its associated sensors could detect process anomalies and other instabilities under varied energy densities. It will be shown how Peregrine reliably identifies common process anomalies such as recoater streaking, superelevation, etc., and can be used in post-build analysis for anomaly spatial distributions throughout the build height to better understand the impact of geometry and processing parameter choice on the build. This work demonstrates measurable progress toward the vision that components can be born-qualified by establishing a real-time monitoring framework, identifying limiting process conditions, and laying the foundation for sensor fusion–enabled prediction pipelines that are scalable across platforms and applicable to nuclear-relevant components.