Search NASA⌕ Search

SEARCH · Search NASA

Results for “image spectrometer instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A visible-infrared imaging spectrometer for planetary missions

This final report summarizes the design effort for the construction of a visible-infrared imaging spectrometer for planetary missions, funded by NASA under the Planetary Instrument Definition and Development Program. The goal was to design and develop a prototype brassboard pushbroom imaging spectrometer covering the 0.35 gm to 2.5 gm spectral region using a simplified optical layout that would minimize the size, mass and parts count of the instrument by using a single holographic grating to disperse and focus light from a single slit onto both the infrared and visible focal plane arrays. Design approaches are presented and analyzed, along with problems encountered and recommended solutions to those problems. In particular, a new type of grating, incorporating two sets of rulings and a filter in a layered structure, is presented for further development.

McCord, Thomas↗

Scientific requirements for a Moderate-Resolution Imaging Spectrometer (MODIS) for EOS

The MODIS is an instrument planned for the sun-synchronous polar orbiting segment of the Space Station system. The radiometer is required to have 1 km resolution in terrestrial remote sensing applications. The monitoring program is targeted to last 10 yr in order to provide a sufficient database for discerning trends as opposed to natural variations. The study areas of interest include tropical deforestation, regrowth and areal distributions, acid rain effects on northern forests, desertification rates and locations, snow cover/albedo relationships and total biomass. MODIS will have 192 channels with 30 m spatial resolution and cover seven bands in the 3.5-12 microns interval for land viewing. Ocean studies will be carried out in 17 bands from 0.4-1.0 micron, and atmospheric scans will be performed over the land and ocean intervals at narrowband wavelengths (1.2 nm). Si detector arrays will be used and will be accompanied by an expected 600:1 SNR and produce data at a rate of 1.4-9.1 Mb/sec.

Barnes, W. L.↗

Planning In-Flight Calibration for XRISM

The XRISM X-ray observatory will fly two advanced instruments, the Resolve high-resolution spectrometer and the Xtend wide-field imager. These instruments, particularly Resolve, pose calibration challenges due to the unprecedented combination of spectral resolution, spectral coverage, and effective area, combined with a need to characterize the imaging fidelity of the full instrument system to realize the mission’s ambitious science goals. We present the status of the XRISM in-flight calibration plan, building on lessons from Hitomi and other X-ray missions. We present a discussion of targets and observing strategies to address the needed calibration measurements, with a focus on developing methodologies to plan a thorough and flexible calibration campaign and provide insight on calibration systematic error. We also discuss observations that exploit Resolve’s spectral resolution to calibrate atomic codes, and cross-calibration between the XRISM instruments and with other observatories.

Eric D Miller↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

Lucy L’Ralph In-Flight Calibration and Results at (152830) Dinkinesh

The L'Ralph instrument is a key component of NASA's Lucy mission, intended to provide spectral image data of multiple Jupiter Trojans. The instrument operates from ∼0.35 to 4 μm using two focal plane assemblies: a 350–950 nm multispectral imager, Multi-spectral Visible Imaging Camera (MVIC), and a 0.97–4 μm imaging spectrometer, Linear Etalon Imaging Spectral Array (LEISA). Instrument calibration was established through ground testing before launch and has been monitored during cruise utilizing internal calibration sources and stellar targets. In-flight data have shown that the instrument thermal performance is exceeding expectations, allowing for early updates to LEISA radiometric and pointing calibrations. MVIC radiometric performance remains stable more than 3 yr since launch. The serendipitous identification of a new flyby target, (152830) Dinkinesh, allowed testing of instrument performance and interleaved LEISA and MVIC acquisitions on an asteroid target. Both MVIC and LEISA obtained data of Dinkinesh and its moon, Selam, demonstrating that they show good spectral agreement with an S- or Sq-type asteroid, along with evidence of a 3 μm absorption feature.

Amy A Simon↗

Correcting for Nonlinearity in a Photodetector

Simple positive-feedback circuit varies bias voltage as necessary. Ideal detector biased with constant voltage, detector current proportional to photon flux plus constant offset. Detector connected between inverting input and ground, and feedback from operational amplifier through feedback resistor Rf make voltage at inverting input equal to noninverting input. Bias voltage held constant. Principle applied to linearizing mercury cadmium telluride infrared detectors in Fourier-transform spectrometers and other spectral and imaging instruments.

Schindler, R. A.↗

Moderate Resolution Imaging Spectrometer - A progress report (April 1989)

The Moderate Resolution Imaging Spectrometer (MODIS) is a facility instrument to be flown on the first Earth Observing System (scheduled launch in the late 1990s). The MODIS has two components. One component is a 110-deg-scan-angle instrument called MODIS-N (nadir). This instrument has 40 selected bands supporting observations of the land surface, the oceans, and atmosphere in the visible, NIR, short-wave IR (1.0-3.0 microns), and thermal IR (3.0-15.0 microns). The other component is a 90-deg-scan-angle scanning instrument that can tilt fore and aft along the satellite track, called MODIS-T (tilt). Both MODIS-N and MODIS-T are nearing the end of detailed design studies. The driving scientific requirements include absolute calibration accuracy 2 percent, instrument-induced polarization less than 2 percent, SNR reaching 800:1 for observing ocean color at large solar zenith angles, and dynamic range allowing observations of cloud characteristics and snow-covered areas.

Salomonson, V. V.↗

Calibration Results for the AXAF Flux Contamination Monitor

The Flux Contamination Monitor (FCM) on the Advanced X-ray Astrophysics Facility (AXAF) serves the purposes of transfering the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center to operation on orbit and of detecting any changes in molecular contamination of the High Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation phase. we describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and the subsequent analysis.

Elsner, Ronald F.↗

Calibration Results for the AXAF Flux Contamination Monitor

The AXAF Flux Contamination Monitor (FCM) serves the purposes of transferring the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) to operation on orbit and of detecting any changes in molecular contamination of the High-Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation. We describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal-plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at the XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and for the subsequent analysis.

Elsner, R. F.↗

ACIS Door Failure Investigation and Mitigation Procedures

NASA's Chandra X-ray Observatory (formerly AXAF) was launched on July 23, 1999 and is currently in orbit performing scientific studies. Chandra is the third of NASA's Great Observatories to be launched, following the Hubble Space Telescope and the Compton Gamma Ray Observatory. One of four primary science instruments on Chandra, and one of only two focal plane instruments, is the Advanced CCD Imaging Spectrometer, or ACIS. The ACIS focal plane and Optical Blocking Filter (OBF) must be launched under vacuum, so a tightly sealed, functioning door and venting subsystem were implemented. The door was opened two and one-half weeks after launch (after most out-gassing of composite materials) and allowed X-rays to be imaged by the ACIS CCD's in the focal plane. A failure of this door to open on-orbit would have eliminated all ACIS capabilities, severely degrading mission science. During the final pre-flight thermal-vacuum test of the fully integrated Chandra Observatory at TRW, the ACIS door failed to open when commanded to do so. This paper describes the efforts, under considerable time pressure, by NASA, its contractors and outside review teams to investigate the failure and to develop modified hardware and procedures which would correct the problem. Of interest is the fact that the root cause of the test failure was never clearly identified despite massive effort. We ultimately focussed on hardware and procedures designed to mitigate the effects of potential, but unproven, failure modes. We describe a frequent real-world engineering situation in which one must proceed on the best basis possible in the absence of the complete set of facts.

Podgorski, William A.↗

Mapping Lithologic Units Exposed on the Summit of Mauna Kea Using AVIRIS Hyperspectral Reflectance Data

The Mauna Kea summit region is largely comprised of cinder cones and lava flows that form the cap of the Mauna Kea Volcano. The cones and flows at the summit are part of the Laupahoehoe Volcanic series. The Laupa hoehoe volcanism occurred both during and after the late Pleistocene Makanaka glacial episode at the summit. In addition, a few Laupahoehoe cones have been glacially eroded as evidenced by oversteepened slopes, which suggests that they predate the Makanaka glacial period. Two notable examples of possible preglacial cones are Puu Waiau and Puu Poliahu. These two cones are also significantly altered, most likely by hydrothermal activity that has weakly cemented the materials on the cones. Well-crystalline sulfates (alunite and jarosite), phyllosilicates, and zeolites, have been found in samples collected from altered cones at the summit. In addition, palagonitic tephra, which have nanophase ferric oxide, allophane, and other poorly crystalline forms of weakly altered basaltic glass (i.e., no phyllosilicates), have been described at several locations on Mauna Kea. While several studies have discussed the occurrence of alteration products on Mauna Kea, the distribution of these materials exposed at the summit has not been extensively mapped. Hyperspectral imaging can provide information for identifying and mapping lithologic units containing alteration minerals, such as are found on Mauna Kea. The Airborne Visible Infrared Imaging Spectrometer (AVIRIS) is a hyperspectral imaging instrument that covers the wavelength range from about 0.4 to 2.5 micron in 224 bands, with a band spacing of 10 nm and average band width of 10 nm

Guinness, E. A.↗

High Altitude Hyperspectral Remote Sensing with AVIRIS

None given. From Intro: This paper describes AVIRIS (the Airborne Visible and InfraRed Imaging Spectrometer) as a remote sensing instrument that is supported, calibrated, and maintained by JPL.

AVIRIS detector fiberoptics remote sensing spectro↗

The Staring OBservations of the Atmosphere (SOBA) Mission Concept

The Staring OBservations of the Atmosphere (SOBA) Mission is a concept that was developed and matured under the guidance of the NASA Ames Project EXellence (APEX) program. If funded, it will provide an unprecedented opportunity to improve ash transport forecasts and climate model simulations associated with volcanic eruptions. NASA and National science objectives require a better understanding of volcanic aerosol and trace gas emissions, transport, chemical transformation, and deposition, since they impact Earth's climate and atmospheric composition, human health, and aviation safety. Natural hazards such as the 2010 eruption of the Eyjafjallajökull volcano in Iceland demonstrated how existing remote-sensing assets were inadequate for individual volcanic event monitoring. During this eruption, available instruments were unable to provide data necessary to initialize volcanic plume transport models so that they could accurately predict the quantity and location of volcanic ash. As a result, thousands of flights around the world were grounded unnecessarily, at great expense. Volcanoes can also play a large role in regulation of the Earth's climate, so SOBA observations will also be used to evaluate and improve volcanic aerosol and trace gas simulation in chemical transport models (CTMs) and global climate models (GCMs). We propose the development of an airborne remote sensing concept and field campaign that will respond to an eruption and provide near real time observations of a volcanic plume, specifically ash injection height, transport, aerosol microphysical physical properties, and the location and concentration of sulfur dioxide (SO2) (sulfate (SO42-) aerosol precursor). This airborne system will utilize a depolarization sensitive, downward looking Light Detection And Ranging (lidar) instrument and an ultraviolet (UV) imaging spectrometer, and will provide data to be ingested by volcanic ash advisory models. Furthermore, the lessons learned in the development of this system could eventually guide regular deployment of similar systems by NASA or other government agencies.

Aerosols↗

Low Temperature Characterization of Mechanical Isolators for Cryocoolers

For spacecraft applications requiring active refrigeration, exported vibrations from a cryocooler can be a concern. One approach to minimizing the vibrations transmitted from cryocoolers to the spacecraft is to mount them on mechanical isolators. Many commercial off-theshelf (COTS) mechanical isolators exist and have been characterized at room temperature for ground applications. However, the space environment presents challenges that complicate the selection process. Mechanical isolators in space must be made of materials that can withstand harsh radiation environments. Future instruments, such as the Mapping Imaging Spectrometer for Europa (MISE) on the Europa Clipper mission, are considering operating cryocoolers with low heat rejection temperatures and mounting them on mechanical isolators. However, the performance of many simple, traditional mechanical isolators at low temperatures is unknown. This paper describes the testing and results of various mechanical isolators able to withstand harsh radiation between 200 K and 300 K. The transmissibility of wire rope type isolators showed very little temperature dependence up to ~500 Hz. On the other hand, the transmissibility of silicone gel was strongly dependent on temperature as the material had an abrupt change in stiffness near its solid-solid phase change. Custom titanium flexures showed the most promise with a maximum transmissibility of 0.04 above 500 Hz and no expected temperature dependence.

Rodriguez, J.I.↗

Shortwave Reflected Energy From NISTAR and EPIC Onboard the DSCOVR Spacecraft

We produce a one-year record of Shortwave reflected energy from the Earth Polychromatic Imaging Camera. Additional hyperspectral information is provided by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and the SCIAMACHY instrument. We spatially integrate our SW reflected energy for an entire EPIC disk and compare with the reflected energy from the SW Band B filtered NISTAR instrument (Electrical substitution radiometer). We also compare with the Single Scanner Footprint CERES observations.

Clark Weaver↗

Remote sensing of Earth's atmosphere and surface using a digital array scanned interferometer: A new type of imaging spectrometer

The capabilities of the digital array scanned interferometer (DASI) class of instruments for measuring terrestrial radiation fields over the visible to mid-infrared are evaluated. DASI's are capable of high throughput, sensitivity and spectral resolution and have the potential for field-of-view spatial discrimination (an imaging spectrometer). The simplicity of design and operation of DASI's make them particularly suitable for field and airborne platform based remote sensing. The long term objective is to produce a versatile field instrument which may be applied toward a variety of atmospheric and surface studies. The operation of DASI and its advantages over other spectrometers are discussed.

Hammer, Philip D.↗

The Gamma-Ray Imaging Spectrometer (GRIS): A new balloon-borne experiment for gamma-ray line astronomy

High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments.

Teegarden, B. J.↗

Robotic Subsurface Analyzer and Sample Handler for Resource Reconnaissance and Preliminary Site Assessment for ISRU Activities at the Lunar Cold Traps

Since the 1960s, claims have been made that water ice deposits should exist in permanently shadowed craters near both lunar poles. Recent interpretations of data from the Lunar Prospector-Neutron Spectrometer (LP- NS) confirm that significant concentrations of hydrogen exist, probably in the form of water ice, in the permanently shadowed polar cold traps. Yet, due to the large spatial resolution (45-60 Ian) of the LP-NS measurements relative to these shadowed craters (approx.5-25 km), these data offer little certainty regarding the precise location, form or distribution of these deposits. Even less is known about how such deposits of water ice might effect lunar regolith physical properties relevant to mining, excavation, water extraction and construction. These uncertainties will need to be addressed in order to validate fundamental lunar In Situ Resource Utilization (ISRU) precepts by 2011. Given the importance of the in situ utilization of water and other resources to the future of space exploration a need arises for the advanced deployment of a robotic and reconfigurable system for physical properties and resource reconnaissance. Based on a collection of high-TRL. designs, the Subsurface Analyzer and Sample Handler (SASH) addresses these needs, particularly determining the location and form of water ice and the physical properties of regolith. SASH would be capable of: (1) subsurface access via drilling, on the order of 3-10 meters into both competent targets (ice, rock) and regolith, (2) down-hole analysis through drill string embedded instrumentation and sensors (Neutron Spectrometer and Microscopic Imager), enabling water ice identification and physical properties measurements; (3) core and unconsolidated sample acquisition from rock and regolith; (4) sample handling and processing, with minimized contamination, sample containerization and delivery to a modular instrument payload. This system would be designed with three mission enabling goals, including: (1) a self-contained, low power, low mass, "black box'' configuration for operations from a lander, various classes of rovers or a surface-based platform with human assistance or robotic anchoring mechanisms; (2) reconfigurable and scalable sample handling for delivery to various types of instrumentation, depending on mission requirements; and (3) the use of advanced automation control and diagnostic techniques that will afford local human deployed, remote teleoperation and fully autonomous intelligent operations. Though a great deal of technology has been advanced toward these objectives, the SASH system faces significant design challenges, including the low gravity environment, various levels of autonomy in operations, radiation exposure, dust contamination, and temperature extremes and deltas. Significant input from the scientific and engineering communities, as well as a significant environmental testing program, will be required to guide the design process.

Gorevan, S. P.↗