Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases↗

A Simple Approach of CCD Camera Calibration for Optical Diagnostics Instrumentation

Solid State array sensors are ubiquitous nowadays for obtaining gross field images in numerous scientific and engineering applications including optical diagnostics and instrumentation. Linear responses of these sensors are often required as in interferometry, light scattering and attenuation measurements, and photometry. In most applications, the linearity is usually taken to be granted without thorough quantitative assessment or correction through calibration. Upper-grade CCD cameras of high price may offer better linearity: however, they also require linearity checking and correction if necessary. Intermediate- or low-grade CCD cameras are more likely to need calibration for linearity . Here, we present two very simple approaches: one for quickly checking camera linearity without any additional setup and one for precisely correcting nonlinear sensor responses. It is believed that after calibration, those sensors of intermediate or low grade can function as effectively as their expensive counterpart.

Cha, Soyoung Stephen↗

Compact Microscope Imaging System Developed

The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. The CMIS can be used in situ with a minimum amount of user intervention. This system, which was developed at the NASA Glenn Research Center, can scan, find areas of interest, focus, and acquire images automatically. Large numbers of multiple cell experiments require microscopy for in situ observations; this is only feasible with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control capabilities. The software also has a user-friendly interface that can be used independently of the hardware for post-experiment analysis. CMIS has potential commercial uses in the automated online inspection of precision parts, medical imaging, security industry (examination of currency in automated teller machines and fingerprint identification in secure entry locks), environmental industry (automated examination of soil/water samples), biomedical field (automated blood/cell analysis), and microscopy community. CMIS will improve research in several ways: It will expand the capabilities of MSD experiments utilizing microscope technology. It may be used in lunar and Martian experiments (Rover Robot). Because of its reduced size, it will enable experiments that were not feasible previously. It may be incorporated into existing shuttle orbiter and space station experiments, including glove-box-sized experiments as well as ground-based experiments.

McDowell, Mark↗

In situ Detection of Plasma Induced Surface Interaction based on Deep Learning based Visual Diagnostics (Technical Report)

It is characteristic for many plasma devices to undergo plasma-material interaction leading to surface erosion. These processes, often not easily detectable, lead to changes in device performance and lifespan. State-of-the-art lifetime tests and wear experiments require over 1000s hours. A self-consistent model for accurately predicting the erosion's effects is not available. In situ detection of these processes is not a trivial task since the surface variations at the early stages have a micron scale. Such limitations not only restrict testing and prediction capabilities but also slow the development of new thrusters and limit mission duration. To address these challenges, an in-situ diagnostic for real-time erosion assessment has been developed, aiming to expedite lifetime testing and broaden experimental campaigns. Several works were dedicated to real-time and in situ monitoring of material erosion during plasma exposure using laser holography, microscopy, and with telemicroscopes. However, the applicability of these approaches is limited due to complexity, cost and less flexibility as they often require placing diagnostic equipment inside the vacuum chamber. In collaboration with Princeton Collaborative Research Facility (PCRF), Princeton Plasma Physics Laboratory (PPPL), a new diagnostic approach is developed, where geometry modifications to the ceramic channel walls were introduced that would result in accelerated channel erosion. We employed Long-distance microscope (LDM) imagery, combined with Deep-Learning based Shape from focus or depth from focus (DFF or SFF) approach, that provides an accessible and cost-effective solution. LDM employs focus variation techniques to continuously capture multiple images of the target object at distinct focal planes. DFF, an optical focus variation method, generates a 3D topographical surface depth map from a sequence of variably focused images. Combined with the developed diagnostic, this approach offers a controllable means to study erosion under accelerated conditions. In this work, we develop Neural Network-based DFF algorithm applicable for LDM data to quantitatively evaluate plasma induced surface modification from LDM data. Next, we develop Deep Learning-based super-resolution depth map image reconstruction technique to increase the resolution of depth maps obtained from DFF algorithm to improve the accuracy of erosion measurements. Thirdly, we develop several image processing techniques to remove noise and improve the quality of depth map image. Here we report the results of initial tests for this approach. An experimental setup designed and built in PPPL was employed that consists of a 3-cm gridded ion source that produces a neutralized argon beam with energies up to 600 eV. A hexagonal boron nitride (h-BN) ceramic target, designed based on computational predictions, was used. Tests were conducted to reconstruct the complex geometry of the target under the lighting conditions of the operated ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development efforts to improve curved-channel microchannel plates

Curved-channel microchannel plate (C-plate) improvements resulting from an ongoing NASA STIS microchannel plate (MCP) development program are described. Performance limitations of previous C-plates led to a development program in support of the STIS MAMA UV photon counter, a second generation instrument on the Hubble Space Telescope. C-plate gain, quantum detection efficiency, dark noise, and imaging distortion, which are influenced by channel curvature non-uniformities, have all been improved through use of a new centrifuge fabrication technique. This technique will be described, along with efforts to improve older, more conventional shearing methods. Process optimization methods used to attain targeted C-plate performance goals will be briefly characterized. Newly developed diagnostic measurement techniques to study image distortion, gain uniformity, input bias angle, channel curvature, and ion feedback, will be described. Performance characteristics and initial test results of the improved C-plates will be reported. Future work and applications will also be discussed.

Corbett, M. B.↗

NASA Tech Briefs, November 2009

Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

Source record↗

Advanced Diagnostic System on Earth Observing One

In this infusion experiment, the Livingstone 2 (L2) model-based diagnosis engine, developed by the Computational Sciences division at NASA Ames Research Center, has been uploaded to the Earth Observing One (EO-1) satellite. L2 is integrated with the Autonomous Sciencecraft Experiment (ASE) which provides an on-board planning capability and a software bridge to the spacecraft's 1773 data bus. Using a model of the spacecraft subsystems, L2 predicts nominal state transitions initiated by control commands, monitors the spacecraft sensors, and, in the case of failure, isolates the fault based on the discrepant observations. Fault detection and isolation is done by determining a set of component modes, including most likely failures, which satisfy the current observations. All mode transitions and diagnoses are telemetered to the ground for analysis. The initial L2 model is scoped to EO-1's imaging instruments and solid state recorder. Diagnostic scenarios for EO-1's nominal imaging timeline are demonstrated by injecting simulated faults on-board the spacecraft. The solid state recorder stores the science images and also hosts: the experiment software. The main objective of the experiment is to mature the L2 technology to Technology Readiness Level (TRL) 7. Experiment results are presented, as well as a discussion of the challenging technical issues encountered. Future extensions may explore coordination with the planner, and model-based ground operations.

Hayden, Sandra C.↗

The SOHO space satellite - UV instrumentation

The UV and EUV instruments designed for the ESA/NASA Solar and Heliospheric Observatory (SOHO) are described, and their characteristics are presented. The SOHO instruments include the SUMER telescope for measuring line profiles and images in the wavelength range 500-1600 A, with a 1.5-arcsec resolution; the Coronal Diagnostics Spectrometer for measuring line ratios and images in the range 170-800 A, with a 2 arcsec resolution; a EUV imaging telescope for producing narrow band pass images in the spectral lines at 171 A, 195 A, 195 A, 284 A, and 304 A, with a 3-arcsec resolution; a UV coronagraph spectrometer for measuring line profiles and images of EUV lines from about 500 A to about 1200 A, with a several arcsec rosolution; and the SWAN, a lens with hydrogen absorption cell for measuring Ly-alpha profiles in the far corona and heliosphere.

Poland, Arthur I.↗

3D Cloud Tomography and Droplet Size Retrieval from Multi-Angle Polarimetric Imaging of Scattered Sunlight from Above

Tomography aims to recover a three-dimensional (3D) density map of a medium or an object. In medical imaging,it is extensively used for diagnostics via X-ray computed tomography (CT). We define and derive a tomographyof cloud droplet distributions via passive remote sensing. We use multi-view polarimetric images to fit a 3Dpolarized radiative transfer (RT) forward model. Our motivation is 3D volumetric probing of vertically-developedconvectively-driven clouds that are ill-served by current methods in operational passive remote sensing. Currenttechniques are indeed based on strictly 1D RT modeling and applied to a single cloudy pixel, where cloud geometrydefaults to that of a plane-parallel slab. Incident unpolarized sunlight, once scattered by cloud droplets, changesits polarization state according to droplet size. Therefore, polarimetric measurements in the rainbow and gloryangular regions can be used to infer the droplet size distribution. This work defines and derives a framework for afull 3D tomography of cloud droplets for both their mass concentration in space and their distribution across arange of sizes. This gridded 3D retrieval of key microphysical properties is made tractable by our novel approachthat involves a restructuring and partial linearization of an open-source polarized 3D RT code to accommodate aspecial two-step iterative optimization technique. Physically-realistic synthetic clouds are used to demonstrate themethodology with rigorous uncertainty quantification, while a real-world cloud imaged by AirMSPI is processedto illustrate the new remote sensing capability

Schechner, Yoav Y.↗

Crush Gun Impact of Unconfined Explosive with Flat-Faced Projectiles at Nominal Velocity of 60 m/s

A pneumatic gun apparatus was designed and built to deliver crushing impacts at velocities of 0-70 m/s. The apparatus is designed to halt the projectile (if desired) approximately 1 mm before impacting the sapphire imaging surface, preventing a complete “pinch” condition from attaining. The primary diagnostics include high-speed visible videography and infrared imaging to determine spatial temperature rise of the sample during impact.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Temporal laser pulse manipulation using multiple optical ring-cavities

An optical pulse stretcher and a mathematical algorithm for the detailed calculation of its design and performance is disclosed. The optical pulse stretcher has a plurality of optical cavities, having multiple optical reflectors such that an optical path length in each of the optical cavities is different. The optical pulse stretcher also has a plurality of beam splitters, each of which intercepts a portion of an input optical beam and diverts the portion into one of the plurality of optical cavities. The input optical beam is stretched and a power of an output beam is reduced after passing through the optical pulse stretcher and the placement of the plurality of optical cavities and beam splitters is optimized through a model that takes into account optical beam divergence and alignment in the pluralities of the optical cavities. The optical pulse stretcher system can also function as a high-repetition-rate (MHz) laser pulse generator, making it suitable for use as a stroboscopic light source for high speed ballistic projectile imaging studies, or it can be used for high speed flow diagnostics using a laser light sheet with digital particle imaging velocimetry. The optical pulse stretcher system can also be implemented using fiber optic components to realize a rugged and compact optical system that is alignment free and easy to use.

Nguyen, Quang-Viet↗

Dynamic and quasi-static strength of additively repaired aluminum

Additive manufacturing has the potential to repair high value components, saving significant time and resources; however, the level of reliability and performance of additive repairs is still relatively unknown. In this work, the structure–property and performance of laser wire additive manufacturing repairs in 1100 aluminum are investigated. Two types of intentional damage are inflicted on the samples and subsequently repaired with pulsed laser deposition additive manufacturing. Quasi-static (10 –3 s –1 ) and high strain-rate (10 –3 s –1 ) mechanical testing is carried out with in situ diagnostics and post-mortem imaging. The results show that while the quasi-static strength and ductility of samples with a repaired region are lower than a pristine sample, the dynamic strength under shock loading is comparable. This work highlights both the potential utility of additive manufacturing for repair purposes, the significant risk of compromised performance of additive parts under specific conditions, and the need to test at varying strain rates to fully characterize material performance.

36 MATERIALS SCIENCE↗

Probing shocks interacting with radiation waves with the Radishock experiment

Both radiation flows and shocks have been extensively studied in the laboratory in the past few decades due to their critical roles in many astrophysical and high-energy density physics processes. In the Radishock experiment, a halfraum-powered radiation wave is driven into a low-density foam and interacts with an ablatively driven, counter-propagating shock. The interacting waves produce a spike in energy density with a temperature greater than the local temperature of the individual waves. As in the successful predecessor experiment, COAX, the primary diagnostic uses absorption spectroscopy at many locations down the cylindrical target, enabling a spatial temperature inference of the radiation wave and its interactions with the shock. Combined with a radiography diagnostic that is capable of imaging the shock and interaction features, we are able to study and inform model predictions of the interaction spike phenomenon. We describe the underlying physics behind the shock interactions with the radiation front and the implications of this experimental study for a broad range of astrophysical phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wall heating by subcritical energetic electrons generated by the runaway electron avalanche source *

Abstract Subcritical energetic electrons (SEEs) produced by the runaway electron (RE) avalanche source at energies below the runaway threshold are found to be the primary contributor to surface heating of plasma-facing components (PFCs) during final loss events. This finding is supported by theoretical analysis, computational modeling with the Kinetic Orbit Runaway electrons Code (KORC), and qualitative agreement with DIII-D experimental observations. The avalanche source generates significantly more secondary electrons below the runaway threshold, which thermalize rapidly when well-confined. However, during a final loss event, the RE beam impacts the first wall, and SEEs are deconfined before they can thermalize. Additionally, because the energy deposition length decreases faster than energy, the deposited energy density, and thus the maximum PFC surface temperature change, is larger for SEEs than REs. KORC simulations employ an analytic first wall to model particle deconfinement onto a non-axisymmetric wall composed of individual tiles. PFC surface heating is calculated using a 1D model extended to include an energy-dependent deposition length scale. Simulations of DIII-D qualitatively agree with infrared (IR) imaging only when SEEs from the avalanche source are included. These results demonstrate that SEEs are the dominant contributor to PFC surface heating and indicate that the avalanche source plays a critical role in the PFC damage caused during final loss events. The prominence of SEEs also has important implications for interpreting IR imaging, one of the primary diagnostics for RE-wall interaction diagnosis, despite REs dominating the energy and current density. This result improves predictions of wall damage due to post-disruption REs to estimate material lifetime and design RE mitigation systems for ITER and future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

A light amplifier for large flat screen fluoroscopy was investigated which will decrease both its size and weight. The work on organ contouring was extended to yield volumes. This is a simple extension since the fluoroscopic image contains density (gray scale) information which can be translated as tissue thickness, integrated, yielding accurate volume data in an on-line situation. A number of devices were developed for analog image processing of video signals, operating on-line in real time, and with simple selection mechanisms. The results show that this approach is feasible and produces are improvement in image quality which should make diagnostic error significantly lower. These are all low cost devices, small and light in weight, thereby making them usable in a space environment, on the Ames centrifuge, and in a typical clinical situation.

Baily, N. A.↗

The SOHO project - Coronal and solar wind investigations

The Solar and Heliospheric Observatory (SOHO) satellite mission is planned to study the solar interior, to investigate the physical phenomena related to the formation of the solar corona and the solar wind, and to make in situ measurements of the solar wind. The SOHO instruments designed to study the solar atmosphere and the solar wind are described. The experiments include the study of solar UV radiation, a coronal diagnostic spectrometer, an extreme UV imaging telescope, a UV coronagraph spectrometer, a white light and spectrometric coronagraph, and a study of solar wind anisotropies.

Poland, A. I.↗

Two-phase flow bubbly mixing for liquid metal magnetohydrodynamic energy conversion

Experiments aimed at improving mixer design and investigating the effects of surfactants on the two-phase mixture in two-phase liquid metal MHD (LMMHD) energy conversion systems are described. In addition to conventional photography, flash X-ray imaging was used as a diagnostic tool. It was demonstrated that a high void fraction (0.8) and low velocity slip ratio (1.2) two-phase homogeneous bubbly mixture can be created. It is expected that such a two-phase mixture can be further expanded in a LMMHD generator while maintaining low velocity slip. In such a way, high generator and overall system efficiency would be achieved, making LMMHD systems competitive for a number of commercial applications.

Fabris, G.↗

Cancer Detection Using Neural Computing Methodology

This paper describes a novel learning methodology used to analyze bio-materials. The premise of this research is to help pathologists quickly identify anomalous cells in a cost efficient method. Skilled pathologists must methodically, efficiently and carefully analyze manually histopathologic materials for the presence, amount and degree of malignancy and/or other disease states. The prolonged attention required to accomplish this task induces fatigue that may result in a higher rate of diagnostic errors. In addition, automated image analysis systems to date lack a sufficiently intelligent means of identifying even the most general regions of interest in tissue based studies and this shortfall greatly limits their utility. An intelligent data understanding system that could quickly and accurately identify diseased tissues and/or could choose regions of interest would be expected to increase the accuracy of diagnosis and usher in truly automated tissue based image analysis.

liquid crystal tunable filters↗