Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Confronting Large‐Eddy Simulations With Stereo Camera Data by Means of Reconstructed Hemispheric Cloud Size Distributions

High-resolution hemispheric camera images at a meteorological site in western Germany are used to analyze the multi-dimensional spatial characteristics of continental cumulus cloud fields, and to evaluate Large-Eddy Simulations on this aspect. Traditional non-hemispheric cloud-detecting instruments provide additional reference data. The main model-observation comparison focuses on cloud size distributions (CSDs), employing two methods: (a) directly using three-dimensional model fields, direct CSDs, and (b) using rendered hemispheric images of the model fields as produced by a camera simulator based on path-tracing. In the latter method, both the real and rendered images are used to three-dimensionally reconstruct the cloud fields, yielding hemispheric CSDs. Advantages of hemispheric comparisons over more classic approaches include (a) fair comparisons between model and data, and (b) full use of the enhanced resolutions and hemispheric spatial coverage of the camera imagery. Basic evaluation of the simulations demonstrates good agreement on thermodynamic structure and its diurnal cycle. Cloud heights and cloud cover are intercompared between the model, camera data and other instrumentation, providing insight into their structural differences. A consistent alignment is found between the hemispheric CSDs from both the model and the cameras. Power law fits reveal structurally lower exponents in hemispheric CSDs compared to non-hemispheric CSDs, which particularly caution against directly comparing hemispheric CSDs to non-hemispheric distributions. This result is robust for sample size and fitting method. These findings inform future use of hemispheric camera systems for studying cumulus cloud field morphology and model evaluation.

54 ENVIRONMENTAL SCIENCES↗

mzPeak: Designing a Scalable, Interoperable, and Future-Ready Mass Spectrometry Data Format

Advances in mass spectrometry (MS) instrumentation, such as higher resolution, faster scan speeds, and improved sensitivity, have significantly increased the volume and complexity of data. The growing adoption of imaging and ion mobility further amplifies these challenges across MS-based omics fields, including proteomics, metabolomics, and lipidomics. While these technologies unlock new possibilities, they also present significant challenges in data management, storage, and accessibility. Existing open formats, such as the XML-based community standards mzML and imzML, struggle to meet the demands of modern MS workflows due to their large file sizes, slow data access, and limited metadata support. Vendor-specific formats, while optimized for proprietary instruments, lack interoperability, comprehensive metadata support and long-term archival reliability. This white paper lays the groundwork for mzPeak, a next-generation community data format designed to address these challenges and support high-throughput, multi-dimensional MS workflows. By adopting a hybrid model that combines efficient binary storage for numerical data and both human and machine-readable metadata storage, mzPeak will reduce file sizes, accelerate data access, and offer a scalable, adaptable solution for evolving MS technologies. For researchers, mzPeak will enable enhanced interoperability across platforms, seamless support for complex workflows including ion mobility and MS imaging, and faster data access compared to existing community formats such as mzML. Its design will ensure data is managed in compliance with regulatory standards, essential for applications such as precision medicine and chemical safety, where long-term data integrity and accessibility are critical. For vendors, mzPeak provides a streamlined, open alternative to proprietary formats, reducing the burden of regulatory compliance while aligning with the industry's push for transparency and standardization. By offering a high-performance, interoperable solution, mzPeak positions vendors to meet customer demands for sustainable data management tools which will be able to handle emerging and future data types and workflows. mzPeak aspires to become the cornerstone of MS data management, empowering researchers, vendors, and developers to innovate and collaborate more effectively.

data formats↗

A Perspective into Operando Methods for Probing Catalytic Interfaces

Rational design of electrocatalysts for (photo)electrochemical (PEC) processes like hydrogen and oxygen evolution and CO2 reduction reactions is aided by the recent improvements in capabilities of operando measurements, where morphology, composition, and/or function are probed during active catalysis. Through operando microscopy and spectroscopy, structure, catalytic microenvironment, oxidation state, adsorbates, and products can be measured to gain a better understanding of catalyst behavior and suggest possible improvements. Visualizing evolving catalyst morphologies, surface compositions, and electrochemical behavior also helps address many fundamental research questions for a better understanding of catalytic mechanisms. Correlating morphology with chemical identity or functional behavior using a variety of innovative microscopy methods is particularly promising for guiding development of next generation catalysts, and there are also many recent examples of using AI and robotics tools to innovate and speed development. In this Perspective, advances made over the past few years in operando imaging of catalysts relevant to solar fuels will be explored, followed by an outlook on technological developments in instrumentation, sample design, and computational power that may be applied to this field.

Catalysts↗

DESI 2024 II: sample definitions, characteristics, and two-point clustering statistics

We present the samples of galaxies and quasars used for DESI 2024 cosmological analyses, drawn from the DESI Data Release 1 (DR1). We describe the construction of largescale structure (LSS) catalogs from these samples, which include matched sets of synthetic reference ‘randoms’ and weights that account for variations in the observed density of the samples due to experimental design and varying instrument performance. We detail how we correct for variations in observational completeness, the input ‘target’ densities due to imaging systematics, and the ability to confidently measure redshifts from DESI spectra. We then summarize how remaining uncertainties in the corrections can be translated to systematic uncertainties for particular analyses. We describe the weights added to maximize the signalto-noise of DESI DR1 2-point clustering measurements. We detail measurement pipelines applied to the LSS catalogs that obtain 2-point clustering measurements in configuration and Fourier space. The resulting 2-point measurements depend on window functions and normalization constraints particular to each sample, and we present the corrections required to match models to the data. We compare the configuration- and Fourier-space 2-point clustering of the data samples to that recovered from simulations of DESI DR1 and find they are, generally, in statistical agreement to within 2% in the inferred real-space over-density field. The LSS catalogs, 2-point measurements, and their covariance matrices will be released publicly with DESI DR1.

79 ASTRONOMY AND ASTROPHYSICS↗

Mask-side Hyper-NA EUV imaging on the SHARP microscope

Hyper-NA, the prospective successor to high-numerical aperture (NA) extreme ultraviolet lithography (EUVL) could be inserted soon after 2030. Hyper-NA poses a number of challenges, including reduced depth of focus, amplified mask three-dimensional effects, and increased mask-side angular range. A Hyper-NA capable extreme ultraviolet (EUV) mask-imaging tool can address these challenges and accelerate research and development toward Hyper-NA. The Sharp High-Numerical Aperture Actinic Reticle Review Project (SHARP) EUV mask microscope is supporting mask-side high-NA imaging since 2015. Implementing mask-side Hyper-NA imaging in 2024 enables research and development toward the corresponding nodes of EUVL. Hyper-NA zoneplates at 0.75 4x/8x NA with a 6.7-deg chief ray angle and 0.85 4x/8x NA with a 7.4-deg chief ray angle are added to the SHARP microscope. Imaging at mask-side Hyper-NA is demonstrated. Imaging of 5-nm half-pitch (wafer scale) horizontal lines and spaces is demonstrated using dipole illumination. Imaging of 5-nm half-pitch (wafer scale) vertical lines and spaces is demonstrated using frequency-doubled imaging of 40-nm hp (mask scale) lines and spaces. Normalized image log slope (NILS) and modulation of Hyper-NA image data match closely to simulations for horizontal lines and spaces. A reduction in NILS of 0.3 or less is observed for vertical lines and spaces in the two-beam imaging regime. Through-focus image data are discussed, comparing different dipole sources and mask-side NAs. Mask-side Hyper-NA photomask imaging has been implemented and demonstrated on the SHARP microscope and is now available to users of the instrument.

Benk, Markus↗

Secondary Emission Detector Modules for High Energy Physics Experiments

The objectives of this Phase I SBIR project and the corresponding work plan consisted of detector geometry simulations and functional studies of pre-prototypes for both venetian-blind type and MEMS type. Modifications and improvements to the vacuum test station and data acquisition were also made throughout the project. In the final stages of this Phase I, we were able to do initial testing of devices built and we provide in this report the results of these measurements and all corresponding conclusions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulating Continuum-based Redshift Measurement in the Roman’s High Latitude Spectroscopic Survey

We investigate the capability of the Nancy Grace Roman Space Telescope’s (Roman) Wide-Field Instrument G150 slitless grism to detect red, quiescent galaxies based on the current reference survey. We simulate dispersed images for Roman reference High-Latitude Spectroscopic Survey (HLSS) and analyze two-dimensional spectroscopic data using the grism Redshift and Line Analysis (Grizli) software. This study focus on assessing Roman grism’s capability for continuum-level redshift measurement for a redshift range of 0.5 ≤ z ≤ 2.5. The redshift recovery is assessed by setting three requirements of: σ z = $\frac{|z–z_{true}|}{1+z}$ ≤ 0.01, signal-to-noise ratio≥ 5 and the presence of a single dominant peak in redshift likelihood function. We find that, for quiescent galaxies, the reference HLSS can reach a redshift recovery completeness of ≥50% for F158 magnitude brighter than 20.2 mag. We also explore how different survey parameters, such as exposure time and the number of exposures, influence the accuracy and completeness of redshift recovery, providing insights that could optimize future survey strategies and enhance the scientific yield of the Roman in cosmological research.

Astronomical simulations↗

Effect of local environment on Ly$α$ line profile in DESI/ODIN LAEs

Lyman-Alpha Emitters (LAEs) are star-forming galaxies with significant Ly$α$ emission and are often used as tracers of large-scale structure at high redshift. We explore the relationship between the Ly$α$ line profile and environmental density with spectroscopy from the Dark Energy Spectroscopic Instrument (DESI) of LAEs selected with narrow-band photometry through the One-hundred-deg$^2$ DECam Imaging in Narrowbands (ODIN) survey. We use LAE surface density maps in the N419 (z $\sim$ 2.45) and N501 (z $\sim$ 3.12) narrow bands to probe the relationship between local environmental density and the Ly$α$ line profile. In both narrow bands, we stack the LAE spectra in bins of environmental density and inside and outside of protocluster regions. The N501 data shows $\sim$15% higher Ly$α$ line luminosity for galaxies in protoclusters, suggesting increased star formation in these regions. However, the line luminosity is not appreciably greater in protocluster galaxies in the N419 band, suggesting a potential redshift evolution of this effect. The shape of the line profile itself does not vary with environmental density, suggesting that line shape changes are caused by local effects independent of a galaxy's environment. These data indicate a potential relationship between LAE local environmental density, ionized gas distribution, and Ly$α$ line luminosity.

Uzsoy, Ana M. [Harvard-Smithsonian Ctr. Astrophys.↗

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

Imaging Power Losses in CdSeTe Solar Cells

Much of the research on CdSeTe photovoltaics is focused on improving the open-circuit voltage (V oc ) of the solar cell. But solar cells operate at the maximum power point (MPP) rather than at V oc . The recombination processes at MPP may be different than those at V oc , and increasing the power output at MPP is the key to advancing efficiency. Here, we introduce a camera-based PL imaging system that enables power loss analysis under operating conditions and across cm-sized areas covering multiple cells. The instrument is demonstrated with CdSeTe devices having efficiencies greater than 19%. An implied current density versus implied voltage (iJV) curve can be produced at each pixel with <20 µm resolution. We find that regions with high implied open circuit voltage are often those with low implied fill factor, showing that voltage loss analysis at open circuit is not sufficient to understand power losses under operating conditions. Measurement of JV curves as a function of irradiance can also be performed in the system, which allows series resistance-free pseudo JV (pJV) curves to be produced. Comparison of pJV to measured JV and iJV curves allows further analysis of the operational losses, pointing the way to higher efficiency.

14 SOLAR ENERGY↗

Aerosol size determination via light scattering of viruses and protein complexes

Abstract The study of ultrafine particle aerosols, those with particle diameters of 100 nm or less, is important due to their impact on our health and environment. However, given their small sizes, such particles can be difficult to measure and trace. Most common optical methods are unable to reach this size range. Other methods exist but incur other limitations, such as the need for electrically charged particles. Here we show how light scattering can be used to detect and measure the size and location of single viruses and protein complexes forming an aerosol beam, as well as trace their path. We were able to detect individual particles down to 16 nm in diameter. The primary purpose of our instrument is to monitor the delivery of single bioparticles to the focus of an X-ray laser to image those particles, but it has the potential to study any other aerosols such as those resulting from ultrafine sea spray, with important consequences for cloud formation and climate modeling, or from combustion, responsible for most air pollution and resulting health impacts.

Physics↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

A Quantum Leap for Dynamic Radiography

Dynamic radiography techniques have been instrumental in advancing the National Nuclear Security Administration's (NNSA) mission since WWII. This paper explores the transformative potential of quantum information science (QIS) to revolutionize dynamic radiography through enhanced image processing, tomographic reconstruction, statistics and uncertainty quantification (UQ), and artificial intelligence integration. By leveraging quantum algorithms to extract previously inaccessible information from existing datasets, this interdisciplinary approach promises unprecedented insights at the intersection of dynamic imaging, artificial intelligence, and quantum information technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗