Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Impedances of nickel electrodes cycled in various KOH concentrations

Recent tests at Hughes have shown that Ni/H2 cells cycled in 26 percent KOH have much longer lives than those cycled in other concentrations. As part of an ongoing program to try to correlate the impedances of nickel electrodes with their life and performance, impedances were measured of a number of electrodes from these tests that had been cycled in concentrations from 21 to 36 percent KOH. These had ranged from about 1000 to 40,000 cycles. After cycling ten times to reduce possible changes due to storage, impedances were measured at five voltages corresponding to low states of charge. The results were analyzed using a standard circuit model including Warburg impedance term. Lower kinetic resistances and Warburg slopes were found for several electrodes which had been cycled in 26 percent KOH even though they had been cycled for a much longer time than the others. Interpretation of the data is complicated by the fact that the cycle lives, storage times, and failure mechanisms varied. Several other circuit models have also been examined, but the best correlations with life were found with parameters obtained from the simple model.

Margaret A Reid↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Effect of H + Exchange and Surface Impurities on Bulk and Interfacial Electrochemistry of Garnet Solid Electrolytes

Contact loss and current constriction pose significant challenges at the Li metal interface of solid-state batteries. For garnet-structured Li 7 La 3 Zr 2 O 12 (LLZO), these effects are amplified by Li + /H + exchange and surface contamination reactions, which lead to conductivity losses and poor Li wetting. In this study, we utilize a variety of surface treatment processes across 37 cells to selectively induce proton exchange and contamination reactions in LLZO. The resulting bulk and surface chemistry is systematically characterized and correlated to changes in electrochemical properties. Additionally, we combine impedance analysis and finite element method modeling to deconvolute sources of impedance contributions at the Li metal interface. Specifically, we show that constriction impedance at the Li metal interface arises not solely from voids, but also from ionically-resistive surface contaminants. Further, these findings emphasize the connection between ionic conductivity and constriction, demonstrating that micron-scale ionically-resistive components increase constriction even with identical contact geometries. Finally, we leverage our comprehensive dataset to highlight unstable overpotential growth as a failure mechanism, additionally showing that the phase of a cell’s impedance is a sensitive indicator for the onset of interfacial instability. Overall, this study clarifies the impacts of proton exchange and surface contamination on electrochemical properties at the Li|solid electrolyte interface and elucidates insights that are generalizable to other solid-state battery systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aperture excited dielectric antennas

The results of a comprehensive experimental and theoretical study of the effect of placing dielectric objects over the aperture of waveguide antennas are presented. Experimental measurements of the radiation patterns, gain, impedance, near-field amplitude, and pattern and impedance coupling between pairs of antennas are given for various Plexiglas shapes, including the sphere and the cube, excited by rectangular, circular, and square waveguide feed apertures. The waveguide excitation of a dielectric sphere is modeled using the Huygens' source, and expressions for the resulting electric fields, directivity, and efficiency are derived. Calculations using this model show good overall agreement with experimental patterns and directivity measurements. The waveguide under an infinite dielectric slab is used as an impedance model. Calculations using this model agree qualitatively with the measured impedance data. It is concluded that dielectric loaded antennas such as the waveguide excited sphere, cube, or sphere-cylinder can produce directivities in excess of that obtained by a uniformly illuminated aperture of the same cross section, particularly for dielectric objects with dimensions of 2 wavelengths or less. It is also shown that for certain configurations coupling between two antennas of this type is less than that for the same antennas without dielectric loading.

Crosswell, W. F.↗

Finding the missing pieces: filling gaps that impede the translation of omics data into models

High-throughput omics technologies such as DNA sequencing have made the sequencing and computational assembly of microbial genomes recovered from the environment relatively routine. Computational inference of the protein products encoded by these genomes, and the associated biochemical functions, should enable the accurate prediction and modeling of microbial metabolism, organismal interactions, and ecosystem processes. However, a lack of scalable, probabilistic protein annotation tools limits the full potential of modeling for understanding the metabolism and biogeochemical cycles of microbial communities. Our approach to improve inference of protein annotations and metabolic models relied on learning from and emulating expert manual curation, leveraging software engineering and data science best practices to scale up the throughput and accuracy of annotations and metabolic model construction, building software to objectively evaluate different annotation strategies, and more closely linking the protein annotation and metabolic model inference process. Outcomes of this research include several improved or new computational tools, including DRAM (Distilled and Refined Annotation of Metabolism) for annotating microbial genomes with protein function and metabolic traits, CAMPER (Curated Annotations for Microbial Polyphenol Enzymes and Reactions) for annotating key polyphenol metabolisms, EC-Bench for comprehensive and unbiased benchmarking of annotation tools, and several apps available via the DOE Systems Biology Knowledgebase (KBase) for building genome-scale metabolic models. We demonstrate that these tools allow us to scalably annotate and understand thousands of genomes for microbial communities from a variety of systems and test cases, including rivers, thawing permafrost, and gut microbiomes. All of these computational tools are available as open-source software, with most broadly and easily accessible to the scientific community via KBase apps.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning-based inversion for acoustic impedance with large synthetic training data: Workflow and data characterization

Where wells are sparse or training data are difficult to label with high-quality wireline-derived impedance logs, machine learning (ML)-based inversion of acoustic impedance typically depends on small training data sets, leading to biased prediction. We have advanced a novel workflow that applies large synthetic seismic training data to reduce facies-related bias. Using a geologically realistic model as the truth model, we randomly select sparse seed wells to perform sequential Gaussian simulation (SGS) for impedance models of the same geometry and simulate facies variability. We implement random forest regression on 30 features extracted from the synthetic volume. We observe that more seed wells tend to reduce facies-induced bias by sampling more types of facies, resulting in a better prediction. We then focus on the responses of SGS models to facies changes, the number of seed wells necessary for a useful synthetic model, and how much a synthetic model can help ML-based inversion. Here, we observe that the SGS synthetic training model outperforms well-direct training in general. For modeled clastic shore-zone systems in Miocene Gulf of Mexico, two or more seed wells are necessary for a significant reduction of root-mean-square error and outliners, and improvement of facies imaging. In a field-data test, we apply a similar workflow to quantitatively predict acoustic impedance, which is then converted to a sand-volume map at a high-frequency sequence (10–100 m), revealing detailed facies and sandstone patterns. Such results are valuable in many geologic and engineering applications, such as hydrocarbon and CO 2 reservoir prospecting, reserve estimation, simulation, etc.

3D seismic↗

An electrochemical study of corrosion protection by primer-topcoat systems on 4130 steel with ac impedance and dc methods

To investigate metal surface corrosion and the breakdown of metal protective coatings, the ac impedance method is applied to six systems of primer coated and primer topcoated 4130 steel. Two primers were used: a zinc-rich epoxy primer and a red lead oxide epoxy primer. The epoxy-polyamine topcoat was used in four of the systems. The EG and G-PARC Model 368 ac impedance measurement system, along with dc measurements with the same system using the polarization resistance method, were used to monitor changing properties of coated 4230 steel disks immersed in 3.5 percent NaCl solutions buffered at pH 5.4 over periods of 40 to 60 days. The corrosion system can be represented by an electronic analog called an equivalent circuit consisting of resistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for the resistors and capacitors, that can be assigned in the equivalent circuit following a least-squares analysis of the data, describe changes that occur on the corroding metal surface and in the protective coatings. Two equivalent circuits have been determined that predict the correct Bode phase and magnitude of the experimental sample at different immersion times. The dc corrosion current density data are related to equivalent circuit element parameters. Methods for determining corrosion rate with ac impedance parameters are verified by the dc method.

Mendrek, M. J.↗

Higher Order Mode Coupling in Feed Waveguide of a Planar Slot Array Antenna

A simple technique was developed to account for the higher order mode coupling between adjacent coupling slots in the feed waveguide of a planar slot array. The method uses an equation relating the slot impedance to the slot voltage and a reaction integral involving the equivalent magnetic current of the slot aperture and the magnetic field coupled from an adjacent slot. In the proposed method, one uses the Elliott s design technique to determine tilt angles and lengths of the coupling slots. The radiating slots are modeled as shunt admittances, and the coupling slots are modeled as series impedances.

Rengarajan, Sembiam↗

Determination of Complex Microcalorimeter Parameters with Impedance Measurements

The proper understanding and modeling of a microcalorimeter s response requires the accurate knowledge of a handful of parameters, such as C, G, alpha, . . . . While a few of these, such 8s the normal state resistance and the total thermal conductance to the heat bath (G) are directly determined from the DC IV characteristics, some others, notoriously the heat capacity (C) and alpha, appear in degenerate combinations in most measurable quantities. The case of a complex microcalorimeter, i.e. one in which the absorber s heat capacity is connected by a finite thermal impedance to the sensor, and subsequently by another thermal impedance to the heat bath, results in an added ambiguity in the determination of the individual C's and G's. In general, the dependence of the microcalorimeter s complex impedance on these parameters varies with frequency. This variation allows us to determine the individual parameters by fitting the prediction of the microcalorimeter model to the impedance data. We describe in this paper our efforts at characterizing the Goddard X-ray microcalorimeters. Using the parameters determined with this method we them compare the pulse shape and noise spectra predicted by the microcalorimeter model to data taken with the same devices.

Saab, T.↗

Impeller leakage flow modeling for mechanical vibration control

HPOTP and HPFTP vibration test results have exhibited transient and steady characteristics which may be due to impeller leakage path (ILP) related forces. For example, an axial shift in the rotor could suddenly change the ILP clearances and lengths yielding dynamic coefficient and subsequent vibration changes. ILP models are more complicated than conventional-single component-annular seal models due to their radial flow component (coriolis and centrifugal acceleration), complex geometry (axial/radial clearance coupling), internal boundary (transition) flow conditions between mechanical components along the ILP and longer length, requiring moment as well as force coefficients. Flow coupling between mechanical components results from mass and energy conservation applied at their interfaces. Typical components along the ILP include an inlet seal, curved shroud, and an exit seal, which may be a stepped labyrinth type. Von Pragenau (MSFC) has modeled labyrinth seals as a series of plain annular seals for leakage and dynamic coefficient prediction. These multi-tooth components increase the total number of 'flow coupled' components in the ILP. Childs developed an analysis for an ILP consisting of a single, constant clearance shroud with an exit seal represented by a lumped flow-loss coefficient. This same geometry was later extended to include compressible flow. The objective of the current work is to: supply ILP leakage-force impedance-dynamic coefficient modeling software to MSFC engineers, base on incompressible/compressible bulk flow theory; design the software to model a generic geometry ILP described by a series of components lying along an arbitrarily directed path; validate the software by comparison to available test data, CFD and bulk models; and develop a hybrid CFD-bulk flow model of an ILP to improve modeling accuracy within practical run time constraints.

Palazzolo, Alan B.↗

Tracking the evolution of processes occurring in silicon anodes in lithium ion batteries by 3D visualization of relaxation times

An unconventional electroanalytical method has been used for tracking processes in silicon anodes in lithium ion batteries: a 3D visualization of relaxation times. Impedance data of the electrodes were collected at different potentials and different cycles during cyclic voltammetry, and were treated by means of the Distribution of Relaxation Times (DRT) method. A 3D visualization of the results allowed to identify the formation of a solid electrolyte interphase on the anode, composed of two layers with different relaxation times. Such findings are not possible by conventional analysis of impedance data by modeling with equivalent circuits, nor by simple DRT alone. Additionally, it was possible to observe that the characteristic relaxation time of the lithiation of the Si anode becomes smaller upon cycling, indicating that the material experiences structural transformations that allow it to lithiate faster. The result is relevant to motivate the use of micron-sized particles in the anode.

25 ENERGY STORAGE↗

Simulation of Impedance Changes with Aging in Lithium Titanate-based Cells Using Physics-Based Dimensionless Modeling

Quantifying aging effects in lithium-ion cells with chemistries that have a flat open circuit potential is challenging. We implement a physics-based electrochemical model to track changes in the electrochemical impedance response of lithium titanate-based cells. Frequency domain equations of a pseudo two-dimensional model are made dimensionless, and the corresponding non-dimensional parameters are estimated using a Levenberg-Marquardt routine. The model weighs the relative contributions of changes in diffusion, ionic conduction within the electrolyte phase against solid phase electronic conduction towards cell aging. Solid-phase diffusion, charge transfer resistance and double layer capacitance at the solid-liquid interface are accounted for in the particle impedance. The estimation routine tracks dimensionless parameters using accelerated cycling data from full cells over 1000 cycles. The model can be deployed within a short time for state estimation using physics-based models without requiring prior knowledge of the battery chemistry, format, or capacity.

25 ENERGY STORAGE↗

Amorphization of Pseudocapacitive T−Nb 2 O 5 Accelerates Lithium Diffusivity as Revealed Using Tunable Isomorphic Architectures

Abstract Intercalation pseudocapacitance can combine capacitor‐like power densities with battery‐like energy densities. Such surface‐limited behavior requires rapid diffusion where amorphization can increase solid‐state diffusivity. Here intercalation pseudocapacitive materials with tailored extents of amorphization in T‐Nb 2 O 5 are first reported. Amorphization was characterized with WAXS, XPS, XAFS, and EPR which suggested a peroxide‐rich (O 2 2− ) surface that was consistent with DFT predictions. A series of tunable isomorphic architectures enabled comparisons while independently varying transport parameters. Through process of elimination, solid‐state lithium diffusion was identified as the dominant diffusive‐constraint dictating the maximum voltage sweep rate for surface‐limited kinetics ( v SLT ), termed the Surface‐Limited Threshold (SLT). The v SLT increased with amorphization however stable cycling required crystalline T‐Nb 2 O 5 . A current‐response model using series‐impedances well‐matched these observations. This perspective revealed that amorphization of T‐Nb 2 O 5 enhanced solid‐state diffusion by 12.2 % and increased surface‐limitations by 17.0 % (stable samples). This approach enabled retaining 95 % lithiation capacity at ∼800 mV s −1 (1,600 C‐rate equivalent).

25 ENERGY STORAGE↗

Design of PGM-free cathodic catalyst layers for advanced PEM fuel cells

Here, the design of cathodic catalysts layer (CCL) consisted of Platinum Group Metal-free (PGM-free) electrocatalysts was done by catalyst coated membrane approach. Three different Fe-Mn-N-C compounds were synthesized with Fe:Mn ratio of 1:1, 2:1 and 2:1 with modified heat treatment profile. The catalysts were characterized by X-ray photoelectron spectroscopy, X-ray powder diffraction, pore and particle size distribution, zeta potential and transmission electron microscopy. Electrocatalysts were integrated into membrane electrode assembly and evaluated by electrochemical methods. Electrochemical impedance spectroscopy in combination with modeling were used for estimation of proton conductivity of CCL and its oxygen diffusivity. It was found that all CCLs possess extremely high proton conductivity, which was demonstrated for the first time for these types of PGM-free catalysts. The observed ORR mechanism was predominantly 4e- due to peroxide/radicals scavenging effect of Mn.

impedance↗

Highly Ordered Hierarchical Anodes for Extreme Fast Charging Batteries (Final Report)

The goal of this project is to enable extreme fast charging (XFC) of Li-ion batteries, which was accomplished through a combination of 1) rational design and manufacturing of hierarchically structured anode architectures; 2) blending graphite/hard carbon into a bulk hybrid anode; 3) engineering artificial solid-electrolyte interphase (SEI) coatings with reduced interphase impedance; 4) computational modeling of coupled transport, kinetic, and electrochemical phenomena; and 5) improved fundamental understanding of lithium plating through operando analysis. This work integrated structural, compositional, and surface modification of graphite anodes, multi-physics modeling of ion transport, electrochemical activity, and heat transfer, advanced strategies to detect Li plating, and semi-automated roll-to-roll cell assembly. The unique facilities at the University of Michigan (UM) and Sandia National Laboratories (SNL) were leveraged to manufacture, prototype, and characterize commercially relevant >2Ah and >180 Wh/kg cells with a target of <20% capacity fade over 500 XFC cycles.

25 ENERGY STORAGE↗

Preliminary analysis of measured sound propagation over various seasonal snow covers

Measurements of acoustic pulse propagation in the 5 to 500-Hz frequency band were conducted under various snow cover conditions during the 1989 to 1990 winter in New Hampshire. The objective was to determine the effect of snow cover thickness and other snow properties on the absorption of acoustic pulses. Blank pistol shots were used as the source of the acoustic waves, and geophones and microphones in an 80 m-long linear array served as receivers. Snow thicknesses ranged from 0.05 to 0.35 m, and densities varied from 100 to 350 kg m(sup -3) during the 10 separate measurement days. Preliminary analysis indicates that the peak pulse amplitude decayed in proportion to approx. gamma (sup -1.7) for most conditions and that the acoustic-to-seismic ratios varied from about 4 to 15 x 10(exp -6) m s(sup -1) Pa(sup -1). Theoretical waveforms were calculated for propagation in a homogeneous atmosphere using Attenborough's model of ground impedance. An automatic fitting procedure for the normalized experimental and theoretical waveforms was used to determine the effective flow resistivity of the snow covers, and gave values of 10 to 35 kN s m(sup -4), in agreement with earlier results.

Albert, Donald G.↗

Environmental fatigue of an Al-Li-Cu alloy. Part 1: Intrinsic crack propagation kinetics in hydrogenous environments

Deleterious environmental effects on steady-state, intrinsic fatigue crack propagation (FCP) rates (da/dN) in peak aged Al-Li-Cu alloy 2090 are established by electrical potential monitoring of short cracks with programmed constant delta K and K(sub max) loading. The da/dN are equally unaffected by vacuum, purified helium, and oxygen but are accelerated in order of decreasing effectiveness by aqueous 1 percent NaCl with anodic polarization, pure water vapor, moist air, and NaCl with cathodic polarization. While da/dN depends on delta K(sup 4.0) for the inert gases, water vapor and chloride induced multiple power-laws, and a transition growth rate 'plateau'. Environmental effects are strongest at low delta K. Crack tip damage is ascribed to hydrogen embrittlement because of the following: (1) accelerated da/dN due to part-per-million levels of H2O without condensation; (2) impeded molecular flow model predictions of the measured water vapor pressure dependence of da/dN as affected by mean crack opening; (3) the lack of an effect of film-forming O2; (4) the likelihood for crack tip hydrogen production in NaCl, and (5) the environmental and delta K-process zone volume dependencies of the microscopic cracking modes. For NaCl, growth rates decrease with decreasing loading frequency, with the addition of passivating Li2CO3, and upon cathodic polarization. These variables increase crack surface film stability to reduce hydrogen entry efficiency. The hydrogen environmental FCP resistance of 2090 is similar to other 2000 series alloys and is better than 7075.

Piascik, Robert S.↗

Environmental fatigue of an Al-Li-Cu alloy. I - Intrinsic crack propagation kinetics in hydrogenous environments

Deleterious environmental effects on steady-state, intrinsic fatigue crack propagation (FCP) rates (da/dN) in peak aged Al-Li-Cu alloy 2090 are established by electrical potential monitoring of short cracks with programmed constant delta K and K(sub max) loading. The da/dN are equally unaffected by vacuum, purified helium, and oxygen but are accelerated in order of decreasing effectiveness of aqueous 1 percent NaCl with anodic polarization, pure water vapor, moist air, and NaCl with cathodic polarization. While da/dN depends on delta K(sup 4.0) for the inert gases, water vapor and chloride induced multiple power-laws, and a transition growth rate 'plateau'. Environmental effects are strongest at low delta K. Crack tip damage is ascribed to hydrogen embrittlement because of the following: (1) accelerated da/dN due to part-per-million levels of H2O without condensation; (2) impeded molecular flow model predictions of the measured water vapor pressure dependence of da/dN as affected by mean crack opening; (3) the lack of an effect of film-forming O2; (4) the likelihood for crack tip hydrogen production in NaCl; and (5) the environmental and delta K-process zone volume dependencies of the microscopic cracking modes. For NaCl, growth rates decrease with decreasing loading frequency, with the addition of passivating Li2CO3, and upon cathodic polarization. These variables increase crack surface film stability to reduce hydrogen entry efficiency. The hydrogen environmental FCP resistance of 2090 is similar to other 2000 series alloys and is better than 7075.

Piascik, Robert S.↗