Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedence analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

FDTD modeling of thin impedance sheets

Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. It is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods. These sheets are characterized by a discontinuity in the tangential magnetic field on either side of the sheet but no discontinuity in tangential electric field. This continuity, or single valued behavior of the electric field, allows the sheet current to be expressed in terms of an impedance multiplying this electric field.

Luebbers, Raymond↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗

The study of microstrip antenna arrays and related problems

In February, an initial computer program to be used in analyzing the four-element array module was completed. This program performs the analysis of modules composed of four rectangular patches which are corporately fed by a microstrip line network terminated in four identical load impedances. Currently, a rigorous full-wave analysis of various types of microstrip line feed structures and patches is being performed. These tests include the microstrip line feed between layers of different electrical parameters. A method of moments was implemented for the case of a single dielectric layer and microstrip line fed rectangular patches in which the primary source is assumed to be a magnetic current ribbon across the line some distance from the patch. Measured values are compared with those computed by the program.

Lo, Y. T.↗

Analytical modeling and simulation of electrical contact resistance for elastic rough electrode surface contact including frictional temperature rise

An improved electrical contact resistance (ECR) model for elastic rough electrode contact is proposed, incorporating the effects of asperity interactions and temperature rise by frictional and joule heating. The analytical simulation results show that the ECR decreases steeply at the beginning of the contact between Al and Cu. However, it becomes stabilized after reaching a specific contact force. It is also found that the longer elapsed sliding contact time, the higher ECR due to the increase in electrical resistivity of electrode materials by the frictional temperature rise at the interface. The effects of surface roughness parameters on ECR are studied through the 3 2 full-factorial design-of-experiment analysis. Based on the two representative roughness parameters, i.e., root-mean-square (rms) roughness and asperity radius, their individual and coupled effects on the saturated ECR are examined. The saturated ECR increases with the rms roughness for a rough machined surface condition, but it is hardly affected by the asperity radius. On the other hand, the saturated ECR increases with both the rms roughness and the asperity radius under a smooth thin film surface condition.

42 ENGINEERING↗

Conversion loss and noise of microwave and millimeter-wave mixers. I - Theory. II - Experiment

The conversion loss and noise of microwave and millimeter-wave mixers are analyzed. Nonlinear capacitance, arbitrary embedding impedances, as well as shot, thermal and scattering noise arising in the diode, figure in the analysis. The anomalous mixer noise noted in millimeter-wave mixers by Kerr (1975) is shown to be explainable in terms of the correlation of down-converted components of the time-varying shot noise. A digital computer analysis of the conversion loss, noise, and output impedance of an 80-120-GHz mixer is also conducted.

Held, D. N.↗

Broadband impedance modeling and single bunch instabilities estimations of the advanced light source upgrade project

We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Uncertainty and Sensitivity Analyses of a Two-Parameter Impedance Prediction Model

This paper presents comparisons of predicted impedance uncertainty limits derived from Monte-Carlo-type simulations with a Two-Parameter (TP) impedance prediction model and measured impedance uncertainty limits based on multiple tests acquired in NASA Langley test rigs. These predicted and measured impedance uncertainty limits are used to evaluate the effects of simultaneous randomization of each input parameter for the impedance prediction and measurement processes. A sensitivity analysis is then used to further evaluate the TP prediction model by varying its input parameters on an individual basis. The variation imposed on the input parameters is based on measurements conducted with multiple tests in the NASA Langley normal incidence and grazing incidence impedance tubes; thus, the input parameters are assigned uncertainties commensurate with those of the measured data. These same measured data are used with the NASA Langley impedance measurement (eduction) processes to determine the corresponding measured impedance uncertainty limits, such that the predicted and measured impedance uncertainty limits (95% confidence intervals) can be compared. The measured reactance 95% confidence intervals encompass the corresponding predicted reactance confidence intervals over the frequency range of interest. The same is true for the confidence intervals of the measured and predicted resistance at near-resonance frequencies, but the predicted resistance confidence intervals are lower than the measured resistance confidence intervals (no overlap) at frequencies away from resonance. A sensitivity analysis indicates the discharge coefficient uncertainty is the major contributor to uncertainty in the predicted impedances for the perforate-over-honeycomb liner used in this study. This insight regarding the relative importance of each input parameter will be used to guide the design of experiments with test rigs currently being brought on-line at NASA Langley.

Jones, M. G.↗

Analysis of a 170-GHz frequency doubler with an array of planar diodes

Analysis of a planar diode multiplier from 85-170 GHz is described. The doubler uses a waveguide mount with two series pairs of diodes in a balanced structure. Because of the difficulties in conventional scale model measurements, numerical electromagnetic simulation based on the finite element method was chosen for the analysis, using a commercial program. To optimize the diode design, the de-embedded diode terminal impedance was studied, as well as the power balance between the diodes. The analysis showed that the matching of the diode impedance to that of the waveguide is quite sensitive to the diode substrate thickness. Thicknesses from 25-100 micron in GaAs were studied as well as 100-micron-thick quartz. The accuracy of the theoretical analysis was verified by careful measurements using a slotted line to determine the diode terminal impedance under large signal pump, for frequencies between 80 and 90 GHz. Good agreement between the measured and simulated diode terminal impedance was observed, although full agreement requires the addition of an empirical loss term. Several options are considered for the source of this loss.

DIODE MULTIPLIER↗

High-intensity sound in air saturated fibrous bulk porous materials

The interaction high-intensity sound with bulk porous materials in porous materials including Kevlar 29 is reported. The nonlinear behavior of the materials was described by dc flow resistivity tests. Then acoustic propagation and reflection were measured and small signal broadband measurements of phase speed and attenuation were carried out. High-intensity tests were made with 1, 2, and 3 kHz tone bursts to measure harmonic generation and extra attenuation of the fundamental. Small signal standing wave tests measured impedence between 0.1 and 3.5 kHz. High level tests with single cycle tone bursts at 1 to 4 kHz show that impedance increases with intensity. A theoretical analysis is presented for high-porosity, rigid-frame, isothermal materials. One dimensional equations of motion are derived and solved by perturbation. The experiments show that there is excess attenuation of the fundamental component and in some cases a close approach to saturation. A separate theoretical model, developed to explain the excess attenuation, yields predictions that are in good agreement with the measurements. Impedance and attenuation at high intensities are modeled.

Kuntz, H. L., II↗

Time Domain Approach for Acoustic Liner Analysis

- Procedures for implementing the Ingard-Myers impedance condition in time domain - Instability issue of the Ingard-Myers Condition - Proposed stabilization of the Ingard-Myers condition - Numerical examples

time domain impedance boundary condition↗

Acoustic Absorption Characteristics of an Orifice With a Mean Bias Flow

The objective of the study reported here was to acquire acoustic and flow data for numerical validation of impedance models that simulate bias flow through perforates. The impedance model is being developed by researchers at High Technology Corporation. This report documents normal incidence impedance measurements a singular circular orifice with mean flow passing through it. All measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube. The mean flow is introduced upstream of the orifice (with the flow and incident sound wave travelling in the same direction) with an anechoic termination downstream of the orifice. Velocity profiles are obtained upstream of the orifice to characterize the inflow boundary conditions. Velocity in the center of the orifice is also obtained. All velocity measurements are made with a hot wire anemometer and subsequent checked with mass flow measurements made concurrently. All impedance measurements are made using the Two-Microphone Method. Although we have left the analysis of the data to the developers of the impedance models that simulate bias flow through perforate, our initial examination indicates that our results follow the trends consistent with published theory on impedance of perforates with a steady bias flow.

Ahuja, K. K.↗

Nanoscale imaging of He-ion irradiation effects on amorphous TaO x toward electroforming-free neuromorphic functions

Resistive switching in thin films has been widely studied in a broad range of materials. Yet, the mechanisms behind electroresistive switching have been persistently difficult to decipher and control, in part due to their non-equilibrium nature. Here, we demonstrate new experimental approaches that can probe resistive switching phenomena, utilizing amorphous TaO x as a model material system. Specifically, we applied scanning microwave impedance microscopy and cathodoluminescence (CL) microscopy as direct probes of conductance and electronic structure, respectively. These methods provide direct evidence of the electronic state of TaO x despite its amorphous nature. For example, CL identifies characteristic impurity levels in TaO x , in agreement with first principles calculations. We applied these methods to investigate He-ion-beam irradiation as a path to activate conductivity of materials and enable electroforming-free control over resistive switching. However, we find that even though He-ions begin to modify the nature of bonds even at the lowest doses, the films' conductive properties exhibit remarkable stability with large displacement damage and they are driven to metallic states only at the limit of structural decomposition. Finally, we show that electroforming in a nanoscale junction can be carried out with a dissipated power of <20 nW, a much smaller value compared to earlier studies and one that minimizes irreversible structural modifications of the films. Importantly, the multimodal approach described here provides a new framework toward the theory/experiment guided design and optimization of electroresistive materials.

36 MATERIALS SCIENCE↗

Effect of Cu on the passivity of Ti–xCu (x = 0, 3 and 5 wt%) alloy in phosphate-buffered saline solution within the framework of PDM-II

The effect of copper content on the passivity of Ti–xCu alloys in a phosphate-buffered saline electrolyte (pH 7.4), in the steady-state condition, was examined using potentiostatic polarization, electrochemical impedance spectroscopy, and Mott-Schottky analysis. The study demonstrates that the oxide layer forms on the Ti–xCu alloys surface have n-type semiconducting character, and the steady-state thickness of the oxide layer is observed linearly and depends on the applied potential. The study observations are in line with the predictions of the Point Defect Model (PDM-II), which provides a physiochemically realistic description of the oxide layer formation on Ti–xCu alloys. The observations reveal that the Cu additions result in a decrease in the charge transfer resistance and capacitances associated with the hydroxide and barrier layer, an increase in the donor density, and reduce the electrochemical resistance of the Ti–xCu alloys. The study also exhibits that the decrease in the steady-state current density after the initial addition of 3 wt% of Cu is attributed to the progressive substitution of copper on the cation sublattice of the film resulting in enhanced electrostatic interaction between the immobilized copper $Cu^{x'}_{Ti}$, and the mobile cation interstitials $Cu^{+}_{i}$, which carries the excess current over and that conveyed by oxygen vacancies $V^{••}_o$ in the barrier layer. Moreover, it is also observed that over a hundred-year implant period, about 0.006 cm (0.06 mm) of Ti–3Cu alloy is predicted to lose due to steady-state corrosion in the PBS solution under the given set of conditions, it is further seen that, as the Cu amount increased from 3 wt% to 5 wt% in the Ti–xCu alloys, the steady-state corrosion rate decreases.

Electrochemical Impedance Spectroscopy↗

Applicability of 1D site response analysis to shallow sedimentary basins: A critical evaluation through physics-based 3D ground motion simulations

One-dimensional site response analysis (1D SRA) remains the standard practice in considering the effect of local soil deposits and predicting site-specific ground motions, although its range of applicability to realistic seismic wavefields is still in question. In this 1D approach, horizontal and vertical ground shaking are assumed to be induced by vertically propagating shear and compressional waves, respectively. A recent study based on analytical two-dimensional (2D) plane waves and simple point source earthquake simulations has shown two mechanistic limitations in this 1D modelling technique for general inclined seismic waves, that is, systematic over-prediction of the vertical motion and wave trapping in the 1D soil column. In this article, we evaluate in detail the applicability of this 1D modelling approach to realistic three-dimensional (3D) simulated seismic wavefields in shallow sedimentary basins. Linear-viscoelastic 1D SRA predictions using two types of input motions that are commonly used in practice—rock outcrop and in-column motions, are compared with the reference true site response results from 3D earthquake simulations in terms of various measures in the frequency and time domain. It is shown that the horizontal motion in the 3D seismic wavefield exhibits dominant shear wave propagation phenomenon, while the vertical motion is a combined effect of compressional and shear waves and can be over-predicted by the 1D approach when the incident seismic waves are inclined. Direct evidence of the wave refraction process that leads to the vertical motion over-prediction is provided. 1D SRA with in-column inputs can yield motions that have significantly longer duration compared to the true 3D site response solution due to trapped waves, casting in doubt the frequent need for increased soil damping in existing site studies to compensate for wave attenuation due to scattering alone. Sensitivity investigation on the increase of soil profile damping by a multiplier D mul shows D mul values compatible with those found in the literature for both horizontal and vertical motions. It is shown that the level of D mul optimized for a best match of the spectral acceleration is dependent on the characteristic of the input motion and a larger D mul is typically required for the vertical component. In contrast, 1D SRA with outcrop motions predicts motions with shorter significant duration due to its inability to capture the basin-edge generated surface waves. A suite of ground motion simulations was performed to assess the sensitivity of the observations to the basin geologic structure including the velocity gradient, rock-basin impedance contrast and basin depth. The analysis results show that the accuracy of the simplified 1D procedure is dependent on the wavefield composition of both the input motions and the true 3D site response solution. While the horizontal motions in shallow sedimentary basins can, to the first order, be reasonably captured by the simplified 1D approach, 1D SRA for the vertical component is in general not reliable and contributions from inclined shear waves should be accounted for in site-specific evaluation of the vertical design ground motion.

1D assumption↗