Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument designs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cassini Camera Contamination Anomaly: Experiences and Lessons Learned

We discuss the contamination 'Haze' anomaly for the Cassini Narrow Angle Camera (NAC), one of two optical telescopes that comprise the Imaging Science Subsystem (ISS). Cassini is a Saturn Orbiter with a 4-year nominal mission. The incident occurred in 2001, five months after Jupiter encounter during the Cruise phase and ironically at the resumption of planned maintenance decontamination cycles. The degraded optical performance was first identified by the Instrument Operations Team with the first ISS Saturn imaging six weeks later. A distinct haze of varying size from image to image marred the images of Saturn. A photometric star calibration of the Pleiades, 4 days after the incident, showed stars with halos. Analysis showed that while the halo's intensity was only 1 - 2% of the intensity of the central peak of a star, the halo contained 30 - 70% of its integrated flux. This condition would impact science return. In a review of our experiences, we examine the contamination control plan, discuss the analysis of the limited data available and describe the one-year campaign to remove the haze from the camera. After several long conservative heating activities and interim analysis of their results, the contamination problem as measured by the camera's point spread function was essentially back to preanomaly size and at a point where there would be more risk to continue. We stress the importance of the flexibility of operations and instrument design, the need to do early infight instrument calibration and continual monitoring of instrument performance.

Cassini↗

Design and Requirements Creep In A Build-To-Print Mission

Build-to-Print designs, or rebuilds of flight proven designs, are attractive to mission stakeholders, as they give the appearance of minimal engineering development cost, risk, and schedule. The reality is that seldom is a project an exact duplicate of a predecessor. Mission reclassification, improvements in hardware, and science objective changes can all serve as a source of requirements and design creep and have ramifications often not fully anticipated during initial proposals. The Thermal Infrared Sensor Instrument (TIRS) was a late addition to the LandSat-8 program to provide infrared imaging to measure evapotranspiration for water cycle management. To meet the launch requirements for LandSat-8, instrument design life requirements were relaxed, the sensor development expedited, and technology development was minimized. Consequently, TIRS was designed as a higher risk instrument, with less redundancy than an instrument critical to mission success. After the successful LandSat-8 launch in 2013 and instrument performance, a rebuild of the instrument for the next LandSat spacecraft was included in the baseline mission success criteria. This paper discusses the technical challenges encountered during the rebuild of the TIRS-2 (Thermal Infrared Sensor 2) instrument and the resultant impacts on the thermal system design.

TIRS-2 Thermal Design↗

SAFIRE - A novel high resolution cooled spectrometer for atmospheric research

The SAFIRE (Spectroscopy of Atmospheric Far Infra-Red Emissions) experiment is discussed with particular reference to the scientific aims and the conceptual instrument design of the project. The principal requirements of the experiment are reviewed, and it is shown how these requirements are met in the instrument concept. In particular, measurements of hydrogen oxides and other important species in the stratosphere require a far infrared limb sounder. Some problems involved in the optical and thermal design of the instrument are examined.

Harries, J. E.↗

In-Flight Thermal Performance of the Lidar In-Space Technology Experiment

The Lidar In-Space Technology Experiment (LITE) was developed at NASA s Langley Research Center to explore the applications of lidar operated from an orbital platform. As a technology demonstration experiment, LITE was developed to gain experience designing and building future operational orbiting lidar systems. Since LITE was the first lidar system to be flown in space, an important objective was to validate instrument design principles in such areas as thermal control, laser performance, instrument alignment and control, and autonomous operations. Thermal and structural analysis models of the instrument were developed during the design process to predict the behavior of the instrument during its mission. In order to validate those mathematical models, extensive engineering data was recorded during all phases of LITE's mission. This inflight engineering data was compared with preflight predictions and, when required, adjustments to the thermal and structural models were made to more accurately match the instrument s actual behavior. The results of this process for the thermal analysis and design of LITE are presented in this paper.

Roettker, William↗

Advanced Systems for Monitoring Underwater Sounds

The term "Passive Acoustic Monitoring System" (PAMS) describes a developmental sensing-and-data-acquisition system for recording underwater sounds. The sounds (more precisely, digitized and preprocessed versions from acoustic transducers) are subsequently analyzed by a combination of data processing and interpretation to identify and/or, in some cases, to locate the sources of those sounds. PAMS was originally designed to locate the sources such as fish of species that one knows or seeks to identify. The PAMS unit could also be used to locate other sources, for example, marine life, human divers, and/or vessels. The underlying principles of passive acoustic sensing and analyzing acoustic-signal data in conjunction with temperature and salinity data are not new and not unique to PAMS. Part of the uniqueness of the PAMS design is that it is the first deep-sea instrumentation design to provide a capability for studying soniferous marine animals (especially fish) over the wide depth range described below. The uniqueness of PAMS also lies partly in a synergistic combination of advanced sensing, packaging, and data-processing design features with features adapted from proven marine instrumentation systems. This combination affords a versatility that enables adaptation to a variety of undersea missions using a variety of sensors. The interpretation of acoustic data can include visual inspection of power-spectrum plots for identification of spectral signatures of known biological species or artificial sources. Alternatively or in addition, data analysis could include determination of relative times of arrival of signals at different acoustic sensors arrayed at known locations. From these times of arrival, locations of acoustic sources (and errors in those locations) can be estimated. Estimates of relative locations of sources and sensors can be refined through analysis of the attenuation of sound in the intervening water in combination with water-temperature and salinity data acquired by instrumentation systems other than PAMS. A PAMS is packaged as a battery-powered unit, mated with external sensors, that can operate in the ocean at any depth from 2 m to 1 km. A PAMS includes a pressure housing, a deep-sea battery, a hydrophone (which is one of the mating external sensors), and an external monitor and keyboard box. In addition to acoustic transducers, external sensors can include temperature probes and, potentially, underwater cameras. The pressure housing contains a computer that includes a hard drive, DC-to- DC power converters, a post-amplifier board, a sound card, and a universal serial bus (USB) 4-port hub.

Lane, Michael↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Geostationary earth climate sensor: Scientific utility and feasibility, phase A

The possibility of accurate broad band radiation budget measurements from a GEO platform will provide a unique opportunity for viewing radiation processes in the atmosphere-ocean system. The CSU/TRW team has prepared a Phase 1 instrument design study demonstrating that measurements of radiation budget are practical from geosynchronous orbit with proven technology. This instrument concept is the Geostationary Earth Climate Sensor (GECS). A range of resolutions down to 20 km at the top of the atmosphere are possible, depending upon the scientific goals of the experiment. These tradeoffs of resolution and measurement repeat cycles are examined for scientific utility. The design of a flexible instrument is shown to be possible to meet the two goals: long-term, systematic monitoring of the diurnal cycles of radiation budget; and high time and space resolution studies of regional radiation features.

Campbell, G. Garrett↗

Star sensor/mapper for the Small Astronomy Satellites.

As a requirement for the Small Astronomy Satellite-B (SAS-B), a star sensor was designed to provide satellite positional data to an accuracy of 3 arc minutes for satellite spin rates of 1/12 rpm and 1 rpm. The star sensor is required to detect stars having a +4 visual magnitude during the sunlit portion of the orbit. The spacecraft orientation can be anything achievable in its near equatorial 500-km orbit. The design of the star sensor resulted in an instrument which weighs 6.5 lbs., consumes 0.4 W and operates at spin rates ranging from 1/12 rpm to 3 rpm. The instrument design incorporates optical features providing excellent uniformity of response across the 5 by 10 deg field of view.

Schenkel, F. W.↗

The solar physics Shuttle/Spacelab program and its relationship to studies of the flare build-up

The main phase of solar physics (including flare-buildup) research on Shuttle/Spacelab during the 1980s centers around the use of facility instruments for multiple-user, multiple flight operations. Three main facilities are being considered: a meter-class optical telescope for visible and near-UV wavelengths, an EUV/XUV/soft X-ray facility, and a hard X-ray imaging facility (including a full-sun 5-600 keV spectrometer, a nuclear gamma ray spectrometer, and an X-ray polarimeter for the 5-100 keV range). Smaller instruments designed for specific observations and other classes of instruments such as solar monitors that are not on the facility level are also being considered.

Neupert, W. M.↗

The Main Electronics Box (MEB) of the HAO coronagraph/polarimeter

The SMM satellite was launched in February, 1980 with a complex of instruments designed to study the active sun. The HAO instrument (c/p) operated satisfactorily until July when a series of partial failures began. This report describes analysis and resolution of problems up to the terminal failure on September 23, 1980. The MEB was replaced in orbit in April, 1984, restoring the observational capability of the c/p instrument. The process of trouble-shooting and restoration of the failed MEB at GSFC is described. Conclusions are presented regarding the cause of the failures encountered.

Robert E Davis↗

Tropospheric Chemistry from Space

Measuring tropospheric chemical constituents from space has been only of the "Holy Grails" of remote sensing. Tropospheric remote sensing has been done in two phases, extracting troposheric constituent information from satellite instruments designed for other purposes and constituent measurements with instruments optimized for tropospheric detection. Examples from the first phase, tropospheric ozone and aerosols from Total Ozone Mapping Spectrometer (TOMS) and Global Ozone Monitoring Experiment (GOME) will be presented. Expected results from upcoming instruments and missions, Atmospheric Ultraviolet Radiance Analyzer (AURA), Ozone Monitoring Instrument (OMI), GOME2, and Scanning Imaging Spectrometer for Atmospheric Chartography (SCIAMACHY) will be presented.

Gleason, James↗

The Lunar Flashlight CubeSat Instrument: A Compact SWIR Laser Reflectometer to Quantify and Map Water Ice on the Surface of the Moon

The Lunar Flashlight (LF) mission will send a CubeSat to lunar orbit via NASA’s Space Launch System (SLS) test flight. The LF spacecraft will carry a novel instrument to quantify and map water ice harbored in the permanently shadowed craters of the lunar South Pole. The LF instrument, an active multi-band reflectometer which employs four high power diode lasers in the 1-2 μm infrared band, will measure the reflectance of the lunar surface near water ice absorption peaks. We present the detailed instrument design and system engineering required to deploy this instrument within very demanding CubeSat resource allocations.

Shelton, Jacob↗

High Elevation Radiation Array (HERA) detectors for airborne thunderstorm investigations

A high-energy atmospheric physics phenomenon, referred to as a terrestrial gamma ray flash (TGF), is associated with lightning and produces large bursts of energetic photon radiation. TGFs will be investigated using a suite of gamma-ray instruments designed and constructed to fly on ten United States Air Force (USAF) WC-130J Hurricane Hunter aircraft as part of an aircrew ionization study led by the Air Force Institute of Technology (AFIT) and the United States Air Force School of Aerospace Medicine (USAFSAM), in cooperation with the 53rd Weather Reconnaissance Squadron (WRS). Each instrument consists of one NaI and one plastic detector, a GPS timing device, and an instrument computer that performs data acquisition. High Elevation Radiation Array (HERA) detectors will be employed to maximize the chances of observing TGFs near their source and to gain a better understanding of their origin, mechanism, ubiquity, and to assess potential hazards posed to military and commercial aircrew and passengers. The HERA program, deployed on 10 separate Air Force aircraft over a multi-year campaign, will result in thousands of observational flight hours and be the largest concerted effort to date to observe TGFs in situ through aircraft observations. In this paper, we give an overview of the scientific goals of this campaign and how the HERA instruments have been designed to meet those goals. Here, we include a detailed description of the HERA instrument, along with mass model and signal processing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hubble Space Telescope servicing mission scientific instrument protective enclosure design requirements and contamination controls

The Scientific Instrument Protective Enclosures were designed for the Hubble Space Telescope Servicing Missions to provide a beginning environment to a Scientific Instrument during ground and on orbit activities. The Scientific Instruments required very stringent surface cleanliness and molecular outgassing levels to maintain ultraviolet performance. Data from the First Servicing Mission verified that both the Scientific Instruments and Scientific Instrument Protective Enclosures met surface cleanliness level requirements during ground and on-orbit activities.

Hansen, Patricia A.↗

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

The Re-Analysis of Ozone Profile Data from a 41-Year Series of SBUV Instruments

In this study we present the validation of ozone profiles from a number of Solar Back Scattered Ultra Violet (SBUV) and SBUV/2 instruments that were recently reprocessed using an updated (Version 8.6) algorithm. The SBUV dataset provides the longest available record of global ozone profiles, spanning a 41-year period from 1970 to 2011 (except a 5-year gap in the 1970s) and includes ozone profile records obtained from the Nimbus-4 BUV and Nimbus-7 SBUV instruments, and a series of SBUV(/2) instruments launched on NOAA operational satellites (NOAA 09, 11, 14, 16, 17, 18, 19). Although modifications in instrument design were made in the evolution from the BUV instrument to the modern SBUV(/2) model, the basic principles of the measurement technique and retrieval algorithm remain the same. The long term SBUV data record allows us to create a consistent, calibrated dataset of ozone profiles that can be used for climate studies and trend analyses. In particular, we focus on estimating the various sources of error in the SBUV profile ozone retrievals using independent observations and analysis of the algorithm itself. For the first time we include in the metadata a quantitative estimate of the smoothing error, defined as the error due to profile variability that the SBUV observing system cannot inherently measure. The magnitude of the smoothing error varies with altitude, latitude, season and solar zenith angle. Between 10 and 1 hPa the smoothing errors for the SBUV monthly zonal mean retrievals are of the order of 1 %, but start to increase above and below this layer. The largest smoothing errors, as large as 15-20%, were detected in in the troposphere. The SBUV averaging kernels, provided with the ozone profiles in version 8.6, help to eliminate the smoothing effect when comparing the SBUV profiles with high vertical resolution measurements, and make it convenient to use the SBUV ozone profiles for data assimilation and model validation purposes. The smoothing error can also be minimized by combining layers of data, and we will discuss recommendations for this approach as well. The SBUV ozone profiles have been intensively validated against satellite profile measurements obtained from the Microwave Limb Sounders (MLS) (on board the UARS and AURA satellites), Stratospheric Aerosol and Gas Experiment (SAGE) and Michelson Interferometer for Passive Atmospheric Sounding (MIPAS). Also, we compare coincident and collocated SBUV ozone retrievals with observations made by ground-based instruments, such as microwave spectrometers, lidars, Umkehr instruments and balloon-borne ozonosondes. Finally, we compare the SBUV ozone profiles with output from the NASA GSFC GEOS-CCM model. In the stratosphere between 25 and 1 hPa the mean biases and standard deviations are within 5% for monthly mean ozone profiles. Above and below this layer the vertical resolution of the SBUV algorithm decreases and the effects of vertical smoothing should be taken into account. Though the SBUV algorithm has a coarser vertical resolution in the lower stratosphere and troposphere, it is capable of precisely estimating the integrated ozone column between the surface and 25 hPa. The time series of the tropospheric - lower stratospheric ozone column derived from SBUV agrees within 5% with the corresponding values observed by an ensemble of ozone sonde stations in North Hemisphere. Drift of the ozone time series obtained from each SBUV(/2) instrument relative to ground based and satellite measurements are evaluated and some features of individual SBUV(l2) instruments are discussed. In addition to evaluating individual instruments against independent observations, we also focus on the instrument to instrument consistency in the series. Overall, Version 8.6 ozone profiles obtained from two different SBUV(l2) instruments compare within a couple of percent during overlap periods and are consistently varying in time, with some exceptions. Some of the noted discrepancies might bssociated with ozone diurnal variations, since the difference in the local time of the observations for a pair of SBUV(l2) instruments could be several hours. Other issues include the potential short-term drift in measurements as the instrument orbit drifts, and measurements are obtained at high solar zenith angles (>85 ). Based on the results of the validation, a consistent, calibrated dataset of SBUV ozone profiles has been created based on internal calibration only.

Kramarova, Natalya↗