Mars Biosignature - Detection Capabilities: A Method for Objective Comparison of In Situ Measurements and Sample Return

A Mars sample-return mission has been proposed within NASA's Mars Exploration Program. Studying Martian samples in laboratories on Earth could address many important issues in planetary science, but arguably none is as scientifically compelling as the question of whether biosignatures indicative of past or present life exist on that planet. It is reasonable to ask before embarking on a sample-return mission whether equivalent investigation of Martian biosignatures could be conducted in situ. This study presents an approach to (1)identifying an optimal instrument suite for in situ detection of biosignatures on Mars,and (2)comparing the projected confidence level of in situ detection in a 2026 timeframe to that of Earth-based analysis. We identify a set of candidate instruments, the development of which is projected to be achievable by 2026 well within a $200 million cost cap. Assuming that any biosignatures near the surface of Mars are similar to those of terrestrial life, we find that this instrument suite, if successfully developed and deployed, would enable in situ biosignature detection at essentially the same level of confidence as that of Earth-based analysis of the same samples. At a cost cap of half that amount,the confidence level of in situbiosignature detection analysis could reach about 90% that of Earth-based investigations.

National Environmental Policy Act (NEPA)

Air intakes for a probative missile of rocket ramjet

The methods employed to test air intakes for a supersonic guided ramjet powered missile being tested by ONERA are described. Both flight tests and wind tunnel tests were performed on instrumented rockets to verify the designs. Consideration as given to the number of intakes, with the goal of delivering the maximum pressure to the engine. The S2, S4, and S5 wind tunnels were operated at Mach nos. 1.5-3 for the tests, which were compartmentalized into fuselage-intake interaction, optimization of the intake shapes, and the intake performance. Tests were performed on the length and form of the ogive, the presence of grooves, the height of traps in the boundary layer, the types and number of intakes and the lengths and forms of diffusers. Attention was also given to the effects of sideslip, effects of the longitudinal and circumferential positions of the intakes were also examined. Near optimum performance was realized during Mach 2.2 test flights of the prototype rockets.

Laruelle, G.

The Updated GEO Population for ORDEM 3.1

The limited availability of data for satellite fragmentations and debris in the geosynchronous orbit (GEO) region creates challenges to building accurate models for the orbital debris environment at such altitudes. Updated methods to properly incorporate and extrapolate measurement data have become a cornerstone of the GEO component in the newest version of the NASA Orbital Debris Engineering Model (ORDEM), ORDEM 3.1. For the GEO region, the Space Surveillance Network (SSN) catalog provides coverage down to a limit of approximately 1 m. A more statistically complete representation of the GEO population for smaller objects, which can pose a high risk to operational spacecraft, is thus dependent on dedicated observations by instruments optimized to observe debris smaller than the SSN cataloging threshold. For ORDEM 3.1, optical data from the Michigan Orbital DEbris Survey Telescope (MODEST) provided the input for building the GEO population down to approximately 30 cm (converting absolute magnitude to size). For smaller sizes, the size distribution of debris in the MODEST dataset was extrapolated down to 10 cm, and orbital parameters were estimated based on the orbits of the larger objects. When compared to previous versions of the model, significant improvements were made to the process of building the GEO population in ORDEM 3.1, both in the assessment of fragmentation debris in the data and assignment of orbital elements within the model. A so-called “debris ring filter,” based on a range of angles between an orbit’s angular momentum vector and that of the stable Laplace plane, was applied to the data to reduce biases from non- GEO objects, such as objects in a GEO-transfer orbit. In addition, a new approach was implemented to assign noncircular mean motions and eccentricities to the fragmentation debris observed by MODEST because the short observation window (5 min) in GEO limits orbit resolution to a circular orbit assumption for assigning orbital parameters. For ORDEM 3.1, non-circular orbital elements were assigned using relationships that were identified between mean motion and the angle between the orbit plane and the stable Laplace plane, as well as between mean motion and eccentricity, based on breakup clouds modeled by the NASA Standard Breakup Model. This approach has yielded a high-fidelity GEO model that has been validated with data from more recent MODEST observation campaigns.

Manis, A.

Astrometry

Progress in astrometry is reviewed. Aspects of photographic astrometry are addressed, including the use and optimization of emulsions as detectors and the application of side-field and long-focus photographic astrometry to the determination of stellar positions, to proper motion surveys, the determination of more accurate parallaxes, the study of binaries, and the examination of the membership and internal motions of star clusters. The advantages and disadvantages of photoelectric astrometry are summarized, and the instruments used in this field is discussed, including scanners, detector arrays, stellar interferometers, space telescopes, and satellites. Promising observational methods for studying binary stars are addressed. Astrometry derived from meridian circle observations is considered, emphasizing the FK4 system. The use of radio astrometry is briefly discussed.

Van Altena, W. F.

Carbon Nanotubes on Titanium Substrates for Stray Light Suppression

A method has been developed for growing carbon nanotubes on a titanium substrate, which makes the nano tubes ten times blacker than the current state-of-the-art paints in the visible to near infrared. This will allow for significant improvement of stray light performance in scientific instruments, or any other optical system. Because baffles, stops, and tubes used in scientific observations often undergo loads such as vibration, it is critical to develop this surface treatment on structural materials. This innovation optimizes the carbon nano - tube growth for titanium, which is a strong, lightweight structural material suitable for spaceflight use. The steps required to grow the nanotubes require the preparation of the surface by lapping, and the deposition of an iron catalyst over an alumina stiction layer by e-beam evaporation. In operation, the stray light controls are fabricated, and nanotubes (multi-walled 100 microns in length) are grown on the surface. They are then installed in the instruments or other optical devices.

Hagopian, John

Determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution, appendix 3

The Always-Convergent Iterative Noise Removal and Deconvolution Method of Ioup is applied as a single-filter in the transform domain to deconvolution with both narrow and wide Gaussian impulse response functions. The wraparound error for both cases is also studied. A method is developed by which one can find the optimum iteration number for single-filter iterative deconvolution of sampled data. The method employs the mean square error (MSE), the square of the difference between the deconvolved result and the input, for optimization. The MSE decreases as the deconvolution iterations proceed, but at the optimum iteration number, the MSE starts to increase. This procedure is repeated for signal-to-noise ratio of 10 to 150. The optimum iteration number and the MSE are plotted vs SNR. By knowing the SNR for a particular experiment, one can find the optimum iteration number and MSE.

Ioup, George E.

Bridging length scales in hard materials with ultra-small angle X-ray scattering – a critical review

Owing to their exceptional properties, hard materials such as advanced ceramics, metals and composites have enormous economic and societal value, with applications across numerous industries. Understanding their microstructural characteristics is crucial for enhancing their performance, materials development and unleashing their potential for future innovative applications. However, their microstructures are unambiguously hierarchical and typically span several length scales, from sub-ångstrom to micrometres, posing demanding challenges for their characterization, especially for in situ characterization which is critical to understanding the kinetic processes controlling microstructure formation. This review provides a comprehensive description of the rapidly developing technique of ultra-small angle X-ray scattering (USAXS), a nondestructive method for probing the nano-to-micrometre scale features of hard materials. USAXS and its complementary techniques, when developed for and applied to hard materials, offer valuable insights into their porosity, grain size, phase composition and inhomogeneities. We discuss the fundamental principles, instrumentation, advantages, challenges and global status of USAXS for hard materials. Using selected examples, we demonstrate the potential of this technique for unveiling the microstructural characteristics of hard materials and its relevance to advanced materials development and manufacturing process optimization. We also provide our perspective on the opportunities and challenges for the continued development of USAXS, including multimodal characterization, coherent scattering, time-resolved studies, machine learning and autonomous experiments. Our goal is to stimulate further implementation and exploration of USAXS techniques and inspire their broader adoption across various domains of hard materials science, thereby driving the field toward discoveries and further developments.

36 MATERIALS SCIENCE

An Experimental and Analytical Evaluation of a Biaxial Test for Determining Shear Properties of Composite Materials

The results of an experimental and analytical investigation of a biaxial tension/compression test for determining shear properties of composite materials are reported. Using finite element models of isotropic and orthotropic laminates, a specimen geometry was optimized. A kinematic fixture was designed to introduce an equal and opposite pair of forces into a specimen with a one inch square test section. Aluminum and several composite laminates with the optimized geometry and a configuration with large stress gradients were tested in the fixture. The specimens were instrumented with strain gages in the center of the test section for shear stiffness measurements. Pure shear strain was measured. The results from the experiments correlated well with finite element results. Failure of the specimens occurred through the center of the test section and appeared to have initiated at the high stress points. The results lead to the conclusion that the optimized specimen is suitable for determining shear modulus for composite materials. Further revisions to the specimen geometry are necessary if the method is to give shear strength data.

Kennedy, John M.

Shuttle Entry Imaging Using Infrared Thermography

During the Columbia Accident Investigation, imaging teams supporting debris shedding analysis were hampered by poor entry image quality and the general lack of information on optical signatures associated with a nominal Shuttle entry. After the accident, recommendations were made to NASA management to develop and maintain a state-of-the-art imagery database for Shuttle engineering performance assessments and to improve entry imaging capability to support anomaly and contingency analysis during a mission. As a result, the Space Shuttle Program sponsored an observation campaign to qualitatively characterize a nominal Shuttle entry over the widest possible Mach number range. The initial objectives focused on an assessment of capability to identify/resolve debris liberated from the Shuttle during entry, characterization of potential anomalous events associated with RCS jet firings and unusual phenomenon associated with the plasma trail. The aeroheating technical community viewed the Space Shuttle Program sponsored activity as an opportunity to influence the observation objectives and incrementally demonstrate key elements of a quantitative spatially resolved temperature measurement capability over a series of flights. One long-term desire of the Shuttle engineering community is to calibrate boundary layer transition prediction methodologies that are presently part of the Shuttle damage assessment process using flight data provided by a controlled Shuttle flight experiment. Quantitative global imaging may offer a complementary method of data collection to more traditional methods such as surface thermocouples. This paper reviews the process used by the engineering community to influence data collection methods and analysis of global infrared images of the Shuttle obtained during hypersonic entry. Emphasis is placed upon airborne imaging assets sponsored by the Shuttle program during Return to Flight. Visual and IR entry imagery were obtained with available airborne imaging platforms used within DoD along with agency assets developed and optimized for use during Shuttle ascent to demonstrate capability (i.e., tracking, acquisition of multispectral data, spatial resolution) and identify system limitations (i.e., radiance modeling, saturation) using state-of-the-art imaging instrumentation and communication systems. Global infrared intensity data have been transformed to temperature by comparison to Shuttle flight thermocouple data. Reasonable agreement is found between the flight thermography images and numerical prediction. A discussion of lessons learned and potential application to a potential Shuttle boundary layer transition flight test is presented.

Horvath, Thomas

Experimental Determination of the Dynamic Hydraulic Transfer Function for the J-2X Oxidizer Turbopump: Methodology - Part One

An advanced methodology for extracting the hydraulic dynamic pump transfer matrix (Yp) for a cavitating liquid rocket engine turbopump inducer+impeller has been developed. The transfer function is required for integrated vehicle pogo stability analysis as well as optimization of local inducer pumping stability. Laboratory pulsed subscale waterflow test of the J-2X oxygen turbo pump is introduced and our new extraction method applied to the data collected. From accurate measures of pump inlet and discharge perturbational mass flows and pressures, and one-dimensional flow models that represents complete waterflow loop physics, we are able to derive Yp and hence extract the characteristic pump parameters: compliance, pump gain, impedance, mass flow gain. Detailed modeling is necessary to accurately translate instrument plane measurements to the pump inlet and discharge and extract Yp. We present the MSFC Dynamic Lump Parameter Fluid Model Framework and describe critical dynamic component details. We report on fit minimization techniques, cost (fitness) function derivation, and resulting model fits to our experimental data are presented. Comparisons are made to alternate techniques for spatially translating measurement stations to actual pump inlet and discharge.

Zoladz, Tom

Erasing the Variable: Empirical Foreground Discovery for Global 21 cm Spectrum Experiments

Spectral measurements of the 21 cm monopole background have the promise of revealing the bulk energetic properties and ionization state of our universe from z approx. 6 − 30. Synchrotron foregrounds are orders of magnitude larger than the cosmological signal, and are the principal challenge faced by these experiments. While synchrotron radiation is thought to be spectrally smooth and described by relatively few degrees of freedom, the instrumental response to bright foregrounds may be much more complex. To deal with such complexities, we develop an approach that discovers contaminated spectral modes using spatial fluctuations of the measured data. This approach exploits the fact that foregrounds vary across the sky while the signal does not. The discovered modes are projected out of each line-of-sight of a data cube. An angular weighting then optimizes the cosmological signal amplitude estimate by giving preference to lower-noise regions. Using this method, we show that it is essential for the passband to be stable to at least approx. 10(exp −4). In contrast, the constraints on the spectral smoothness of the absolute calibration are mainly aesthetic if one is able to take advantage of spatial information. To the extent it is understood, controlling polarization to intensity leakage at the approx. 10(exp −2) level will also be essential to rejecting Faraday rotation of the polarized synchrotron emission. Subject headings: dark ages, reionization, first stars - methods: data analysis - methods: statistical

Variable

Simultaneous Retrieval of Selected Optical Water Quality Indicators From Landsat-8, Sentinel-2, and Sentinel-3

Constructing multi-source satellite-derived water quality (WQ) products in inland and nearshore coastal waters from the past, present, and future missions is a long-standing challenge. Despite inherent differences in sensors’ spectral capability, spatial sampling, and radiometric performance, research efforts focused on formulating, implementing, and validating universal WQ algorithms continue to evolve. This research extends a recently developed machine-learning (ML) model, i.e., Mixture Density Networks (MDNs) (Pahlevan et al., 2020; Smith et al., 2021), to the inverse problem of simultaneously retrieving WQ indicators, including chlorophyll-a (Chla), Total Suspended Solids (TSS), and the absorption by Colored Dissolved Organic Matter at 440 nm (a cdom (440)), across a wide array of aquatic ecosystems. We use a database of in situ measurements to train and optimize MDN models developed for the relevant spectral measurements (400–800 nm) of the Operational Land Imager (OLI), MultiSpectral Instrument (MSI), and Ocean and Land Color Instrument (OLCI) aboard the Landsat-8, Sentinel-2, and Sentinel-3 missions, respectively. Our two performance assessment approaches, namely hold-out and leave-one-out, suggest significant, albeit varying degrees of improvements with respect to second-best algorithms, depending on the sensor and WQ indicator (e.g., 68%, 75%, 117% improvements based on the hold-out method for Chla, TSS, and a cdom (440), respectively from MSI-like spectra). Using these two assessment methods, we provide theoretical upper and lower bounds on model performance when evaluating similar and/or out-of-sample datasets. To evaluate multi-mission product consistency across broad spatial scales, map products are demonstrated for three near-concurrent OLI, MSI, and OLCI acquisitions. Overall, estimated TSS and a cdom (440) from these three missions are consistent within the uncertainty of the model, but Chla maps from MSI and OLCI achieve greater accuracy than those from OLI. By applying two different atmospheric correction processors to OLI and MSI images, we also conduct matchup analyses to quantify the sensitivity of the MDN model and best-practice algorithms to uncertainties in reflectance products. Our model is less or equally sensitive to these uncertainties compared to other algorithms. Recognizing their uncertainties, MDN models can be applied as a global algorithm to enable harmonized retrievals of Chla, TSS, and a cdom (440) in various aquatic ecosystems from multi-source satellite imagery. Local and/or regional ML models tuned with an apt data distribution (e.g., a subset of our dataset) should nevertheless be expected to outperform our global model.

Machine learning

Hyperspectral Radiative Transfer Modeling to Explore the Combined Retrieval of Biophysical Parameters and Canopy Fluorescence from FLEX - Sentinel-3 Tandem Mission Multi-Sensor Data

The FLuorescence EXplorer (FLEX) satellite mission, selected as ESA's 8th Earth Explorer, has been designed forthe measurement of sun-induced fluorescence (F) spectra emitted by plants. This will be accomplished through amulti-sensor approach by placing it in a common orbit in tandem with the Sentinel-3 (S3) mission, which willhave two optical sensors on board, OLCI (Ocean and Land Colour Instrument) and SLSTR (Sea and Land SurfaceTemperature Radiometer) to complement FLEX. These S3 instruments will be used in combination with theimaging spectrometers on board FLEX to provide data useful for atmospheric correction of FLEX data. However,a fully synergetic approach, i.e. by exploiting the spectral and directional information from all tandem missioninstruments together, is an attractive alternative which is explored in this paper. By employing all combined topof-atmosphere (TOA) spectral radiance data, one can (i) characterize the relevant optical properties of the atmosphere,(ii) retrieve biophysical canopy properties including the associated reflectance anisotropy, and (iii)retrieve a more accurate and consistent canopy F.Regarding retrieval methods, Fraunhofer Line Depth (FLD) and Spectral Fitting (SF) are well-known techniquesapplied to hyperspectral data. Both methods depend on a high spectral resolution and assume aLambertian (isotropic) canopy reflectance. However, most vegetation canopies are non-Lambertian. This impliesthat, in particular when ignoring the anisotropic surface reflection, substantial retrieval errors can occur due tothe interaction between atmospheric absorption bands and surface reflectance anisotropy. In this paper, a novelmethod based on spectral radiative transfer (RT) modeling is proposed, in which coupled RT models are used tosimulate TOA radiance spectra. These are then matched with ‘measured' spectra in order to retrieve surfacefluorescence, along with a suite of biophysical parameters, by model inversion through optimization. By applyingcoupled RT models of the soil-leaf-canopy and the surface-atmosphere systems, TOA radiance spectra canbe simulated for all optical sensors of this tandem mission. In this way, complex effects due to surface reflectanceanisotropy and the spectral sampling by the various instruments, which are difficult to compensate for in the endproducts, are properly taken into account by their incorporation in the forward modeling. Next, by model inversionof TOA radiance data via optimization, the most accurate F retrievals can be achieved in a consistentmanner, along with important canopy level biophysical parameters that may help interpret the F spectrum, suchas chlorophyll content and leaf area index (LAI). The potential of this approach has been explored in a numericalexperiment, and the results are presented in this paper. We find that, with the assumed well-characterized andplausible FLEX/S3 instrument performances, the simultaneous retrieval of biophysical canopy parameters and Fspectra would be possible with a remarkable accuracy, provided the correct atmospheric characterization isavailable.

Verhoef, Wouter

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg

ASMS 2024 Investigation of Uranyl Perchlorate Anion Complexes in the Gas Phase via Infrared Multiphoton Dissociation and Collision Induced Dissociation

Investigation of Uranyl Perchlorate Anion Complexes in the Gas Phase via Infrared Multiphoton Dissociation and Collision Induced Dissociation Brittany D. M. Hodges, Christopher A. Zarzana, JungSoo Kim, Jonathan Martens, and W. C. M. Berden Introduction (120 words max) Effects of electronic structure on chemical bonding and reactivity play critical roles shaping the chemical bonding and reactivity behaviors of heavy elements. Understanding the role of f electrons in bond formation between the actinide-series elements like uranium with other ligands is critical for solving technical challenges associated with these heavy elements, important to nuclear fuel cycles, efficient separations of rare earth metals, and understanding the chemistry of stored nuclear fuels and related environmental management sites. In this study, we further examine the interactions between uranyl and the perchlorate ion in order to understand the structures of these ions through the use of IRMPD. Here we report the IRMPD spectra of [UO2(ClO4)3]-, [UO3(ClO4)2]-, and a proposed transition state. Methods (120 word max) IRMPD spectra and CID spectra were acquired using a Bruker amaZon QIT/MS instrument at the Free-Electron Lasers for Infrared eXperiments (FELIX) laboratory at Radboud University. The FELIX QIT/MS is modified to allow for the high-intensity tunable IR beam from FELIX to be directed into the ion packet, resulting in multiphoton dissociation that is measured only when the IR frequency is in resonance with an adequately high absorption vibrational mode of the mass-selected complex. DFT geometry optimizations and frequency calculations using the Gaussian suite of programs were performed using B3LYP, TPSSh, and PBE0 level of theory with 6-31+G(d) basis for the O, C, H, and N atoms and the SDD basis set for U. The SDD basis set employs the Stuttgart/Dresden effective core potential. Preliminary Data or Plenary Speakers Abstract (300 words max) Metal ion clusters of uranyl perchlorate were formed via direct electrospray ionization. For each metal ligand complex of interest, the parent ion was isolated and collision induced dissociation fragmentation and Infrared Multiphoton Dissociation (IRMPD) fragmentation spectra were acquired. Results presented here are the first look at the IRMPD spectra of [UO3(ClO4)2]-, [UO2(ClO4)3]-. Structures were examined using Gaussian at different levels of theory B3LYP level of theory, TPPSh and PBE0 levels, to reflect the behaviors of uranium metal ligand complexes most accurately. In these structures, we identified an overlap between each of these uranyl stretches resulting in their largely being obscured by a perchlorate mode. The CID product spectra agree with similar structures reported by Groenewold for uranyl nitrate in 2006 (10.1021/ja058106n).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

The ICEBERG Test Stand for DUNE Cold Electronics Development

ICEBERG is a liquid argon time projection chamber at Fermilab for the purpose of testing detector components and software for the Deep Underground Neutrino Experiment (DUNE). The detector features a 1.15m x 1m anode plane following the specifications of the DUNE horizontal drift far detector and a newly installed X-ARAPUCA photodetector. The status of ICEBERG is reported along with analysis of noise, pulser, and cosmic ray data from the ninth run beginning May 2024 with the goal of advising the DUNE collaboration on the optimal wire readout electronics configuration. In addition, development of an absolute energy scale calibration method is currently underway using known sources such as cosmic ray muon Michel electrons at the ~10 MeV scale and $^{39}$Ar decay electrons at the ~100keV scale. Research into AI-based identification of such events at the data acquisition level is introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record

Empirical Absolute Calibration Model for Multiple Pseudo-Invariant Calibration Sites

This work extends an empirical absolute calibration model initially developed for the Libya 4 Pseudo-Invariant Calibration Site (PICS) to five additional Saharan Desert PICS (Egypt 1, Libya 1, Niger 1, Niger 2, and Sudan 1), and demonstrates the efficacy of the resulting models at predicting sensor top-of-atmosphere (TOA) reflectance. It attempts to generate absolute calibration models for these PICS that have an accuracy and precision comparable to or better than the current Libya 4 model, with the intent of providing additional opportunities for sensor calibration. In addition, this work attempts to validate the general applicability of the model to other sites. The method uses Terra Moderate Resolution Imaging Spectroradiometer (MODIS) as the reference radiometer and Earth Observing-1 (EO-1) Hyperion image data to provide a representative hyperspectral reflectance profile of the PICS. Data from a region of interest (ROI) in an “optimal region” of 3% temporal, spatial, and spectral stability within the PICS are used for developing the model. The developed models were used to simulate observations of the Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+), Landsat 8 (L8) Operational Land Imager (OLI), Sentinel 2A (S2A) MultiSpectral Instrument (MSI) and Sentinel 2B (S2B) MultiSpectral Instrument (MSI) from their respective launch date through 2018. The models developed for the Egypt 1, Libya 1 and Sudan 1 PICS have an estimated accuracy of approximately 3% and precision of approximately 2% for the sensors used in the study, comparable to the current Libya 4 model. The models developed for the Niger 1 and Niger 2 sites are significantly less accurate with similar precision.

Raut, Bipin