Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated demand management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (control-lable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Energy-efficient building technologies

Buildings consume one-third of the total final energy produced on the globe and are responsible for almost 40 percent of total carbon dioxide generation annually. The latest carbon dioxide burden of buildings approached 10 Gigatons in the year 2019. Energy-efficient building technologies are necessary to address the climate change induced by greenhouse gases and fulfill the growth in demand and continuously depleting energy reserves. To meet the net-zero carbon footprint goals, sustainable, renewable energy resources, efficient building technologies, and demand management strategies are needed. Achieving zero emissions will require buildings to be equipped with energy-efficient technologies while completely avoiding on-site fossil fuel consumption and being only powered by renewable energy. In this context, this chapter provides an overview of various building technologies, including envelopes, materials, equipment, appliances, and integration concepts, which will play a significant role in lowering the overall energy consumption in both existing building stock and new buildings. Specifically, the following areas are discussed in detail: emerging building envelope designs, thermal comfort and refrigeration equipment, bridging technologies for improved energy efficiency in the ongoing energy transition, hybrid renewable (photovoltaic) configurations, energy storage technologies, miscellaneous appliances, refrigerants, and renewable fuels. The influence of key design and operating characteristics on annual carbon footprint is presented.

Cheekatamarla, Praveen↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Estimated impacts of forest restoration scenarios on smoke exposures among outdoor agricultural workers in California

Abstract As wildfires continue to worsen across western United States, forest managers are increasingly employing prescribed burns as a way to reduce excess fuels and future wildfire risk. While the ecological benefits of these fuel treatments are clear, little is known about the smoke exposure tradeoffs of using prescribed burns to mitigate wildfires, particularly among at-risk populations. Outdoor agricultural workers are a population at increased risk of smoke exposure because of their time spent outside and the physical demands of their work. Here, we assess the smoke exposure impacts among outdoor agricultural workers resulting from the implementation of six forest management scenarios proposed for a landscape in the Central Sierra, California. We leverage emissions estimates from LANDIS-II to model daily PM 2.5 concentrations with the Hybrid Single Particle Lagrangian Integrated Trajectory Model (HYSPLIT) and link those to agricultural employment data from the Bureau of Labor Statistics. We find a u-shaped result, in that moderate amounts of prescribed burning result in the greatest reduction in total smoke exposure among outdoor agricultural workers, particularly during months of peak agricultural activity due to wildfire-specific smoke reductions. The reduction in total smoke exposure, relative to scenarios with the least amount of management, decreases as more prescribed burning is applied to the landscape due to the contributions of the fuel treatments themselves to overall smoke burden. The results of this analysis may contribute to preparedness efforts aimed at reducing smoke exposures among outdoor agricultural workers, while also informing forest management planning for this specific landscape.

Environmental Sciences & Ecology↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources: Preprint

Integration of a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problem requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs) including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperformed other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Optimization of distributed compute resources utilization in the CMS Global Pool

The CMS Submission Infrastructure is the primary system for managing computing resources for CMS workflows, including data processing, simulation, and analysis. It integrates geographically distributed resources from Grid, HPC, and cloud providers into federated pools managed by HTCondor and Glidein- WMS, for a total of around 500k CPU cores. This system dynamically manages workloads based on priorities defined by the collaboration. Additionally, CMS scheduling strategies must be flexible to handle multiple concurrent workloads while considering changing processing demands and resource availability from various providers.Efficient utilization of vast amounts of distributed compute resources is a key element for the success of the scientific programs of the LHC experiments. Optimizing the system is essential to maximize resource efficiency and fully utilize the distributed computing power. The CMS Submission Infrastructure team thus systematically investigates sources of inefficiency in workload scheduling to reduce their impact. In addition, a strategy of pilot overloading has been introduced to compensate for other inefficiency sources, thereby optimizing resource utilization and enhancing computational throughput.

Mascheroni, Marco [UC, San Diego (main)]↗

Lifting and Dropping VMs to Dynamically Transition Between Time- and Space-sharing for Large-Scale HPC Systems

As HPC environments increasingly integrate with edge based systems, system architectures will need to handle a broader class of workloads and scheduling requirements. One result of this shift will be the need to simultaneously support bulk-synchronous parallel (BSP) and on-demand service based applications on the same infrastructure. This in turn will require that future resource management approaches utilize both space-shared as well as time-shared resource scheduling strategies. In this work we introduce the concept of "VM-lifting'' (and its inverse "VM-Dropping'') which allows dynamically switching an HPC workload between space-shared and time-shared scheduling regimes. Our work targets co-kernel based HPC system software environments, in which multiple specialized OS kernels execute natively on dedicated physical resource partitions inside a single compute node. With VM-lifting, a native co-kernel can be migrated at runtime to and from locally hosted Virtual Machine Environments due to changing scheduling requirements of the node. This allows an HPC node to be dynamically (re-)configured as either a time-shared Infrastructure-as-a-Service (IaaS) resource or a dedicated space shared resource based on the current workload demands. We have implemented this approach in the context of the Hobbes Exascale System Software stack and have demonstrated that a node can be reconfigured with minimal impact on the running applications.

Gordon, Nick↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Integration and Visualization for Enhanced Resilience and Sustainability in Hydropower (DIVERS-H)

U.S. hydropower plants face potential threats from shrinking water supply, rising demands, and warmer stream temperatures from various causes. Power plant owners, operators, and regulators require new tools to take advantage of and interpret the diverse range of scientific data being produced by both observational methods (for example, satellite, radar, stream gauges) and computer modeling methods that evaluate and predict how earth's dynamic systems (atmosphere, oceans, land surface, and sea ice) are changing and interacting. Combining datasets such as these with AI-based analyses introduces a novel decision support system to help users anticipate and address potential impacts on power generation stations. This new technology has been named DIVERS-H for "Data Integration and Visualization for Enhanced Resilience and Sustainability in Hydropower." In Phase I, technical feasibility was established with the development and demonstration of all the new technologies that are required. Most notably, DIVERS-H will use new artificial intelligence (AI) methods to capture the complex dynamics of water availability, demand, and environmental changes. In addition, new data management software was developed, and a prototype user interface was implemented as the precursor to a full scale decision support system. With technical research complete, the project focus now shifts to development of a commercial software product to provide users with actionable insight into water availability and the risk/resilience of critical systems at their locations of interest. Although DIVER-H was originally conceived as a tool for hydroelectric power applications, the same underlying technology can be readily applied to other water-consuming systems including coal, natural gas, oil, and nuclear power plants.

Chaudhary, Aashish [Kitware, Inc., Clifton Park, N↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Energy Storage Using Solid Particles for Long-Duration Energy Storage

The rapid growth of renewable energy increases the importance of economically firming the electricity supply from variable solar photovoltaic- and wind-power generators. Energy storage will be the key to manage variability and to bridge the generation gap over time scales of hours or days for high renewable grid integration. The integration of renewable power and storage of excess electricity has several significant and positive impacts including: 1) expanding the renewable energy portion of total electricity generation, 2) improving the peak-load response, and 3) coordinating the electricity supply and demand over the grid. Long-duration energy storage can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Several energy storage methods are deployed or under development, including mechanical, chemical or electrochemical, and thermal energy storage (TES). Comparing their economic potential for different scales and applications helps identify suitable technology to support high renewable grid integration. Despite the progress of TES technologies developed and deployed with concentrating solar power (CSP) systems, TES has been undervalued for its potential role in electric energy storage. This paper introduces TES methods applicable to grid energy storage and particularly focuses on solid-particle-based TES to serve the purpose of long-duration energy storage (LDES). The objective of this paper is to present a standalone particle-based TES system for electric storage and to show the potential of TES systems for LDES applications over other energy storage methods such as batteries, compressed-air energy storage, or pumped-storage hydropower.

27 ARPA - Advanced Research Projects Agency-Energy↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

Rapid deployment of residential photovoltaic (PV) systems helps decarbonize our electricity supplies, but under certain circumstances, high-penetration PV may pose challenges to the electrical distribution grid. In a project funded by the U.S. Department of Energy's Solar Energy Technologies Office and Building Technologies Office, the National Renewable Energy Laboratory and its partners studied how flexible building loads and battery storage, when coordinated at home-level and community-level scales, can be used to address those challenges and enhance grid resilience. In this webinar, we will discuss the methodology, simulation and field pilot results, insights from partners, and lessons learned from the project.

artificial intelligence↗

Energy Efficiency Analysis and Grid Service Results for Commercial Buildings using the VOLTRON IoT Platform

In fiscal year 2021 (FY21), the Commercial Buildings Integration Program (CBI) within the Building Technologies Office (BTO), funded PNNL to conduct a field evaluation of the AIRCx and ILC using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load (beyond the traditional demand response) in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings opportunities (10% to 30%) as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective compared to a manual process in meeting the Re-tuning/retro commissioning (RCx) mandates and there is a pathway for broader adoption of this approach. This report provides AIRCx and ILC results for two building located in District of Columbia managed by the energy service provider Intellimation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗