Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion conductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Oxygen-Mass-Flow Calibration Cell

Proposed calibration standard for mass flow rate of oxygen based on conduction of oxygen ions through solid electrolyte membrane made of zirconia and heated to temperature of 1,000 degrees C. Flow of oxygen ions proportional to applied electric current. Unaffected by variations in temperature and pressure, and requires no measurement of volume. Calibration cell based on concept used to calibrate variety of medical and scientific instruments required to operate with precise rates of flow of oxygen.

Martin, Robert E.↗

Electrochemical approaches for chemical and biological analysis on Mars

Obtaining in situ chemical data from planetary bodies such as Mars or Europa can present significant challenges. The one analytical technique that has many of the requisite characteristics to meet such a challenge is electroanalysis. Described here are three electroanalytical devices designed for in situ geochemical and biological analysis on Mars. The Mars Environmental Compatibility Assessment (MECA) was built and flight qualified for the now cancelled NASA Mars 2001 Lander. Part of MECA consisted of four "cells" containing arrays of electrochemical based sensors for measuring the ionic species in soil samples. A next-generation MECA, the Robotic Chemical Analysis Laboratory (RCAL), uses a carousel-type system to allow for greater customization of analytical procedures. A second instrument, proposed as part of the 2007 CryoScout mission, consists of a flow-through inorganic chemical analyzer (MICA). CryoScout is a torpedo-like device designed for subsurface investigation of the stratigraphic climate record embedded in Mars' north polar cap. As the CryoScout melts its way through the ice cap, MICA will collect and analyze the meltwater for a variety of inorganics and chemical parameters. By analyzing the chemistry locked in the layers of dust, salt, and ice, geologists will be able to determine the recent history of climate, water, and atmosphere on Mars and link it to the past. Finally, electroanalysis shows its abilities in the detection of possible microorganism on Mars or elsewhere in the solar system. To identify an unknown microorganism, one that may not even use Earth-type biochemistry, requires a detection scheme which makes minimal assumptions and looks for the most general features. Recent work has demonstrated that the use of an array of electrochemical sensors which monitors the changes in a solution via electrical conductivity, pH, and ion selective electrodes, can be used to detect minute chemical perturbations caused by the growth of bacteria and with the correct methodology provide unamibiguous detection of such life forms.

Non-NASA Center↗

Cathodes Delivered for Space Station Plasma Contactor System

The International Space Station's (ISS) power system is designed with high-voltage solar arrays that typically operate at output voltages of 140 to 160 volts (V). The ISS grounding scheme electrically ties the habitat modules, structure, and radiators to the negative tap of the solar arrays. Without some active charge control method, this electrical configuration and the plasma current balance would cause the habitat modules, structure, and radiators to float to voltages as large as -120 V with respect to the ambient space plasma. With such large negative floating potentials, the ISS could have deleterious interactions with the space plasma. These interactions could include arcing through insulating surfaces and sputtering of conductive surfaces as ions are accelerated by the spacecraft plasma sheath. A plasma contactor system was baselined on the ISS to prevent arcing and sputtering. The sole requirement for the system is contained within a single directive (SSP 30000, paragraph 3.1.3.2.1.8): "The Space Station structure floating potential at all points on the Space Station shall be controlled to within 40 V of the ionospheric plasma potential using a plasma contactor." NASA is developing this plasma contactor as part of the ISS electrical power system. For ISS, efficient and rapid emission of high electron currents is required from the plasma contactor system under conditions of variable and uncertain current demand. A hollow cathode plasma source is well suited for this application and was, therefore, selected as the design approach for the station plasma contactor system. In addition to the plasma source, which is referred to as a hollow cathode assembly, or HCA, the plasma contactor system includes two other subsystems. These are the power electronics unit and the xenon gas feed system. The Rocketdyne Division of Boeing North American is responsible for the design, fabrication, assembly, test, and integration of the plasma contactor system. Because of technical and schedule considerations, the NASA Lewis Research Center was asked to manufacture and deliver the engineering model, the qualification model, and the flight HCA units for the plasma contactor system as government furnished equipment. To date, multiple units have been built. One cathode has demonstrated approximately 28 000-hr lifetime, two development HCA units have demonstrated over 15 000-hr lifetime, and one HCA unit has demonstrated more than 38 000 ignitions. All eight flight HCA's have been manufactured, acceptance tested, and are ready for delivery to the flight contractor.

Patterson, Michael J.↗

Single-Event Effect Testing of the Cree C4D40120D Commercial 1200V Silicon Carbide Schottky Diode

This study was undertaken to determine the single event effect (SEE) susceptibility of the commercial silicon carbide 1200V Schottky diode manufactured by Cree, Inc. Heavy-ion testing was conducted at the Texas A&M University Cyclotron Single Event Effects Test Facility (TAMU). Its purpose was to evaluate this device as a candidate for use in the Solar-Electric Propulsion flight project.

silicon carbide (SiC)↗

Single-Event Effect Testing of the ON Semiconductor BSS123 N-Channel Logic Level Enhancement Mode FET and the Vishay Si1013R P-Channel MOSFET

This study was undertaken to determine the single event effect (SEE) susceptibility of two different MOSFET components. Heavy-ion testing was conducted at the Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Space Effects (BASE) Facility 88” Cyclotron. Its purpose was to evaluate these devices as candidates for use on Goddard Modular SmallSat Architecture (GMSA) adapter board for the GTOSat project.

Michael J Campola↗

Low-Power Ion Propulsion for Small Spacecraft

Analyses were conducted which indicate that sub kW-class ion thrusters may provide performance benefits for near-Earth space commercial and science missions. Small spacecraft applications with masses ranging from 50 to 500 kg and power levels less than 0.5 kW were considered. To demonstrate the efficacy of propulsion systems of this class, two potential missions were chosen as examples; a geosynchronous north-south station keeping application, and an Earth orbit magnetospheric mapping satellite constellation. Xenon ion propulsion system solutions using small thrusters were evaluated for these missions. A payload mass increase of more than 15% is provided by a 300-W ion system for the north-south station keeping mission. A launch vehicle reduction from four to one results from using the ion thruster for the magnetospheric mapping mission. Typical projected thruster performance over the input power envelope of 100-300 W range from approximately 40% to 54% efficiency and approximately 2000 to 3000 seconds specific impulse. Thruster technologies required to achieve the mission-required performance and lifetime are identified.

Patterson, Michael J.↗

Study directed at development of an implantable biotelemetry ion detector

A literature search was conducted to currently update known information in the field of ion-selective electrodes. The review attempts to identify present trends in cation and anions selective electrodes pertinent to the area of bioimplantable units. An electronic circuit was designed to provide the high impedance interface between the ion-selective sensors and signal-processing equipment. The resulting design emphasized the need for low power and miniaturization. Many of the circuits were constructed and used to evaluate the ion-selective electrodes. A cuvette capable of holding the ion-selective and the reference electrodes was designed and constructed. This equipment was used to evaluate commercially available ion-selective electrodes and the electrodes designed and constructed in the study. The results of the electrode tests are included.

Hanley, L. D.↗

Sensitivity of model calculations to uncertain inputs, with an application to neutron star envelopes

A method is given for determining the sensitivity of certain types of calculations to the uncertainties in the input physics or model parameters; this method is applicable to problems that involve solutions to coupled, ordinary differential equations. In particular the sensitivity of calculations of the thermal structure of neutron star envelopes to uncertainties in the opacity and equation of state is examined. It is found that the uncertainties in the relationship between the surface and interior temperatures of a neutron star are due almost entirely to the imprecision in the values of the conductive opacity in the region where the ions form a liquid; here the conductive opacity is, for the most part, due to the scattering of electrons from ions.

Epstein, R. I.↗

The plasma wake of mesosonic conducting bodies. II - An experimental parametric study of the mid-wake ion density peak

An experimental investigation of the disturbed flow field created by conducting bodies in a mesosonic, collisionless plasma stream is reported. The mid-wake region is investigated, where, for bodies of the order of a Debye length in size, the focused ion streams converge to form a significant current density peak on the wake axis. A parametric description is obtained of the behavior of the amplitude, width, and position of this peak. The results also indicate that portions of the axial ion peak are created by additional mechanisms and that body geometry affects the mid-wake structure only when the sheath is sufficiently thin to conform to the shape of the body.

Stone, N. H.↗

Effects of heavy ions on electron temperatures in the solar corona and solar wind

The effects of the reduction in the thermal conductivity due to heavy ions on electron temperatures in the solar corona and solar wind are examined. Large enhancements of heavy ions in the corona appear to be necessary to give appreciable changes in the thermal gradient of the electrons. These enhancements, if they should occur, may contribute to the understanding of some low values of solar wind temperature measurements at 1 AU.

Nakada, M. P.↗

Synthesis of H2 in dirty ice mantles by fast ion energy loss: New experimental results increase the relevance of this mechanism

Recent experimental results support the importance of H2 production in molecular clouds by cosmic ray bombardment of the mantles of grains. The formation of molecules different from those originally present in the irradiated layer can be explained by the production of molecular fragments induced by the release of energy if the impinging fast particle. One way of considering the process is in terms of a transiently hot cylinder, initially about 50 A in diameter, that exists around the track of an individual fast ion. Since ice has a relatively low thermal conductivity, energy lost by the ion in the ice layers remains confined around the track for time long enough to be thermalized. The hot cylinder increases in diameter and decreases in temperature on a time scale of 10(exp -11) to 10(exp -10) sec. Molecular fragments that are formed in this high temperature region acquire enough mobility to recombine with different partners, forming new molecules. A Monte Carlo simulation of the interaction between cosmic rays and grain mantles, at various depths in the core of a spherical molecular cloud, was performed. The simulation was continued until 40,000 ions had hit each grain of the type and size chosen. During the performed experiments thin icy films made of H2O and CD4 mixed in the gas phase and deposited on a cold finger at 9 K were irradiated with 1.5 MeV helium beams. Among synthesized molecules were found H2, HD, and D2.

Pirranello, Valero↗

Positive ions in the mesosphere.

Positive ions have been measured using the parachute borne blunt probe, a subsonic system launched on meteorological rockets, which measures polar electrical conductivities in the 30 to 80 km altitude range. A central feature of the daytime positive conductivity profiles is a sharp break occurring between 60 and 70 km which indicates the transition from galactic cosmic ray to solar ultraviolet ionization, and, hence provides information about the nitric oxide density. In the 50-60 km region the positive ion conductivity is relatively constant with altitude and correlates well with atmospheric temperature down to 35 km. Using temperature and pressure profiles and a reduced mobility, the conductivity profiles may be converted to density profiles. The average mid-latitude daytime profile at intermediate solar zenith angles showed a minimum at 63.5 km.

Hale, L. C.↗

Novel Polyimide Battery Separator Imbibed with Room-Temperature Ionic Liquids

The journey to Mars will require advancements in many existing technologies, including space power and energy storage systems. According to the 2015 NASA Technology Roadmaps, energy storage is a critical technology area to develop for both terrestrial as well as future long-term space missions. Currently, batteries represent one of the major areas in need of advancement, both in terms of energy density as well as safety. Recently, concerns regarding the fire safety of commercial lithium-ion batteries have prompted efforts to produce nonflammable battery components, namely the electrolyte and separator. Commercial lithium-ion batteries utilize polyolefin separators imbibed with a lithium salt dissolved in cyclic carbonates. This separator/electrolyte combination imparts good ionic conductivities in the range of 10(exp -2) to 10(exp -3) S/cm. However, the cyclic carbonates and polyolefin separator are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative to cyclic carbonates. They offer good ionic conductivities, similar to those observed in cyclic carbonates, but are inherently nonvolatile and nonflammable giving them a safety advantage. Many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Polyimide aerogels possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85 porous), required for lithium ion conduction, as well as good mechanical properties. Furthermore, these materials are compatible with all tested RTILs. By creating a polyimide gel and imbibing the gel with a RTIL containing a lithium salt instead of super critically drying them to form aerogels, a nonflammable separator/electrolyte system with conductivities in the range of 1x10(exp -3) S/cm has been demonstrated.

Polyimide↗

Model calculations of the dayside ionosphere of Venus - Energetics

A model of the energy balance of the dayside ionosphere of Venus is presented. Calculations of the dayside electron and ion temperature profiles are carried out and compared with data from experiments on the Pioneer Venus orbiter. The coupled heat conduction equations for electrons and ions are solved for several values of the solar zenith angle. It is shown that thermal conductivities are inhibited by the presence of a horizontal magnetic field. A realistic model of the magnetic field that includes fluctuations is employed in deriving an appropriate expression for the thermal conductivity. The contributions of photoelectrons, ion chemistry, Joule heating, and solar wind heating to the energy balance of the ionosphere are considered.

Cravens, T. E.↗

Ion energetics in the Venus nightside ionosphere

Consideration is given to the energetics of the ion gas flowing across the terminator into the Venus nightside ionosphere. Expressions are derived for the transport time of the ion gas (through 1 radian in solar zenith angle), the heat transfer time from the hot electron gas to the ions of an amount equal to the ion thermal energy), and the time required for vertical heat conduction to remove the internal energy of the ion column above a reference altitude, and it is shown that the time constant for transport is an order of magnitude smaller than the electron heat transfer time and comparable to the conduction time, and thus the ion gas is not a vertical conductive steady state. The conversion of bulk flow ion kinetic energy into heat is suggested as the mechanism responsible for the maintenance of the nightside ion temperatures at their observed values. It is thus concluded that the flow of the ion gas is quasi-adiabatic, and that steady-state, vertical, one dimensional energy balance models must be used with caution in the Venus ionosphere.

Knudsen, W. C.↗

Thermal Control and Enhancement of Heat Transport Capacity of Two-Phase Loops With Electrohydrodynamic Conduction Pumping

There are three kinds of electrohydrodynamics (EHD) pumping based on Coulomb force: induction pumping, ion-drag pumping, and pure conduction pumping. EHD induction pumping relies on the generation of induced charges. This charge induction in the presence of an electric field takes place due to a non-uniformity in the electrical conductivity of the fluid which can be caused by a non-uniform temperature distribution and/or an inhomogeneity of the fluid (e.g. a two-phase fluid). Therefore, induction pumping cannot be utilized in an isothermal homogeneous liquid. In order to generate Coulomb force, a space charge must be generated. There are two main mechanisms for generating a space charge in an isothermal liquid. The first one is associated with the ion injection at a metal/liquid interface and the related pumping is referred to as ion-drag pumping. Ion-drag pumping is not desirable because it can deteriorate the electrical properties of the working fluid. The second space charge generation mechanism is associated with the heterocharge layers of finite thickness in the vicinity of the electrodes. Heterocharge layers result from dissociation of the neutral electrolytic species and recombination of the generated ions. This type of pumping is referred to as pure conduction pumping. This project investigates the EHD pumping through pure conduction phenomenon. Very limited work has been conducted in this field and the majority of the published papers in this area have mistakenly assumed that the electrostriction force was responsible for the net flow generated in an isothermal liquid. The main motivation behind this study is to investigate an EHD conduction pump for a two-phase loop to be operated in the microgravity environment. The pump is installed in the liquid return passage (isothermal liquid) from the condenser section to the evaporator section. Unique high voltage and ground electrodes have been designed that generate sufficient pressure heads with very low electric power requirements making the EHD conduction pumping attractive to applications such as two-phase systems (e.g. capillary pumped loops and heat pipes). Currently, the EHD conduction pump performance is being tested on a two-phase loop under various operating conditions in the laboratory environment. The simple non-mechanical and lightweight design of the EHD pump combined with the rapid control of performance by varying the applied electric field, low power consumption, and reliability offer significant advantages over other pumping mechanisms; particularly in reduced gravity applications.

Seyed-Yagoobi, J.↗