Search NASA⌕ Search

SEARCH · Search NASA

Results for “islanding operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Field Verification of Grid-Forming Inverter-Based Power Plant Performance for Transmission System Reliability

This report describes some examples of the operation of two grid-forming (GFM) inverter-based photovoltaic-battery hybrid power plants connected to the electric system of the island of Kauai in Hawaii. Both plants are photovoltaic power plants with battery energy storage and are connected to the networked transmission system operated by Kauai Island Utility Cooperative (KIUC), along with several other power plants including an oil-fired plant, diesel generators, small hydroelectric plants, a biofuel plant, and several other photovoltaic plants.

14 SOLAR ENERGY↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗

Higher Order Parametric Excitation Modes for Spaceborne Quadrupole Mass Spectrometers

This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupole mass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and the ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system.When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.

Gershman, D. J.↗

Quantum information processing with majorana bound states in superconducting circuits

In a weak link of two s-wave superconductors (SCs) coupled via a time-reversal-invariant (TRI) topological superconducting (TSC) island, a Josephson current can flow due to Cooper pairs tunneling in and out of spatially separated Majorana Kramers pairs (MKPs), which are doublets of Majorana bound states (MBSs). The sign of the resulting Josephson current is fixed by the joint parity of the four Majorana bound states that make up the MKPs on the TSC island. This parity-controlled Josephson effect can be used as a read-out mechanism for the joint parity in Majorana-based quantum computing. For a TSC island with four terminals, the SC leads can address a Majorana superconducting qubit (MSQ) formed by the charge ground states of the TSC island's terminals. Cooper pair splitting enables single-qubit operations, qubit read-out, as well as two-qubit entangling gates. Hence, TSC islands between SC leads may provide an alternative approach to superconducting quantum computation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Modified Andronov-Hopf Oscillator-Based Grid-Forming Converter with Emulated Virtual Cable for Enhanced Power Sharing Performance

Nonlinear oscillator-based grid-forming converters offer superior dynamic and steady-state performance, making them an attractive solution for interconnecting renewable resources. This paper proposes a novel modified Andronov-Hopf oscillator to enhance the operating spectrum and facilitate the integration of renewable energy sources. An inner loop controller based on the Lyapunov energy function is implemented to achieve robust stability and performance, while a virtual cable emulation strategy enables seamless parallel operation. Comprehensive modeling and simulation studies validate the effectiveness of the proposed system, demonstrating its capabilities in addressing diverse operating scenarios, including grid faults, renewable energy fluctuations, and parallel operation. The proposed solution exhibits fast transient response, robust stability, and flexible operation, making it a valuable contribution to the field of renewable energy integration. The results of this study can be used to inform the design and implementation of next-generation grid-forming converters, enabling a more sustainable and reliable energy future. Additionally, the proposed system's ability to operate in both grid-connected and islanded modes makes it an ideal candidate for remote and off-grid renewable energy applications. The proposed solution's scalability and modularity also make it suitable for large-scale renewable energy integration. The proposed system is verified through MATLAB/Simulink and PLECS simulations, demonstrating its effectiveness in ensuring robust and efficient operation.

Andronov-Hopf Oscillator (AHO)↗

JSC Pharmacy Services for Remote Operations

The Johnson Space Center Pharmacy began operating in March of 2003. The pharmacy serves in two main capacities: to directly provide medications and services in support of the medical clinics at the Johnson Space Center, physician travel kits for NASA flight surgeon staff, and remote operations, such as the clinics in Devon Island, Star City and Moscow; and indirectly provide medications and services for the International Space Station and Space Shuttle medical kits. Process changes that occurred and continued to evolve in the advent of the installation of the new JSC Pharmacy, and the process of stocking medications for each of these aforementioned areas will be discussed. Methods: The incorporation of pharmacy involvement to provide services for remote operations and supplying medical kits was evaluated. The first step was to review the current processes and work the JSC Pharmacy into the existing system. The second step was to provide medications to these areas. Considerations for the timeline of expiring medications for shipment are reviewed with each request. The third step was the development of a process to provide accountability for the medications. Results: The JSC Pharmacy utilizes a pharmacy management system to document all medications leaving the pharmacy. Challenges inherent to providing medications to remote areas were encountered. A process has been designed to incorporate usage into the electronic medical record upon return of the information from these remote areas. This is an evolving program and several areas have been identified for further improvement.

Stoner, Paul S.↗

A tool for assessing demand side management and operating strategies for isolated microgrids

Globally, power system operators are exploring ways to leverage the capabilities of smart meters to implement fine-grained demand side management (DSM). Here this paper presents a new simulation tool to evaluate operating strategies for smart-meter-enabled (SME) islanded microgrids being advanced for sustainable rural electrification in emerging economies. Based on MATLAB/Simulink, the tool's component-level models of small microgrids can be easily configured. Alternative rule-based operating strategies are implemented with controllable supply and storage components as well as other components driven by external factors (e.g., weather and time of day). To account for the wide range of possible operating conditions in real-world applications, statistical metrics can be evaluated using Monte Carlo (MC) methods based on user-defined, time-dependent probability distributions for demands, supplies, and environmental variables. Features of the tool are demonstrated with case studies for a representative microgrid in rural Rwanda.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Growth in the Number of SSN Tracked Orbital Objects

The number of objects in earth orbit tracked by the US Space Surveillance Network (SSN) has experienced unprecedented growth since March, 2003. Approximately 2000 orbiting objects have been added to the "Analyst list" of tracked objects. This growth is primarily due to the resumption of full power/full time operation of the AN/FPS-108 Cobra Dane radar located on Shemya Island, AK. Cobra Dane is an L-band (23-cm wavelength) phased array radar which first became operational in 1977. Cobra Dane was a "Collateral Sensor" in the SSN until 1994 when its communication link with the Space Control Center (SCC) was closed. NASA and the Air Force conducted tests in 1999 using Cobra Dane to detect and track small debris. These tests confirmed that the radar was capable of detecting and maintaining orbits on objects as small as 5-cm diameter. Subsequently, Cobra Dane was reconnected to the SSN and resumed full power/full time space surveillance operations on March 4, 2003. This paper will examine the new data and its implications to the understanding of the orbital debris environment and orbital safety.

Stansbery, Eugene G.↗

What Crime? Legal Jurisdiction over Civilians in the Pacific Proving Ground

In late 1948 the Atomic Energy Commission “designated Enewetak Atoll as a permanent proving ground.” Subsequently renamed, the Pacific Proving Ground (PPG), six nuclear tests, including Mike, were conducted on the atoll. When Mike vaporized an entire island, it became clear that Enewetak’s small islands were insufficient and Bikini Atoll, abandoned after Operation Crossroads, was made part of the PPG. Authority to create the PPG resided in a “Trusteeship” agreement between the United States and the United Nations. Following the first World War, the Marshall Islands became a “Mandate” of the League of Nations. After World War II, the League’s successor, the United Nations, converted the Marshall Islands to a “Strategic Trusteeship” with the United States as its administrator. The Strategic Trust designation gave the U.S. nearly unfettered control over the islands, including the right to establish the PPG.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NOAA PSL Microwave Radiometer Block Island / Thermodynamic retrievals TROPoe

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous brightness temperature measurements at 35 channels observed with a microwave radiometer MP3000A operated by NOAA Physical Sciences Laboratory on the Block Island for WFIP3. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the MWR housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Plasma self-driven current in tokamaks with magnetic islands

Magnetic island perturbations may cause a reduction in plasma self-driven current that is needed for tokamak operation. A novel effect on tokamak self-driven current revealed by global gyrokinetic simulations is due to magnetic-island-induced 3D electric potential structures, which have the same dominant mode numbers as that of the magnetic island, whereas centered at both the inner and outer edge of the island. The non-resonant potential islands are shown to drive a current through an efficient nonlinear parallel acceleration of electrons. In large aspect ratio (large-A) tokamak devices, this new effect can result in a significant global reduction of the electron bootstrap current when the island size is sufficiently large, in addition to the local current loss across the island region due to the pressure profile flattening. It is shown that there exists a critical magnetic island width for large-A tokamaks beyond which the electron bootstrap current loss is global and increases rapidly with the island size. As such, this process may introduce a size limit for tolerable magnetic islands in large-A tokamak devices in the context of steady state operation. On the other hand, the current loss caused by magnetic islands in low-A tokamaks such as spherical tokamak (ST) NSTX/U is minor. The reduction of the axisymmetric current by magnetic islands scales with the square of island width. However, the loss of the current is mainly local to the island region, and the pace of current loss as the island size increases is substantially slower compared to large-A tokamaks. In particular, the bootstrap current reduction in STs is even smaller in the reactor-relevant high-β p regime where neoclassical tearing modes are more likely to develop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of U.S. Urban Surface Temperature Using GOES-16 and GOES-17 Data: Urban Heat Island and Temperature Inequality

Abstract This study utilizes hourly land surface temperature (LST) data from the Geostationary Operational Environmental Satellite (GOES) to analyze the seasonal and diurnal characteristics of surface urban heat island intensity (SUHII) across 120 largest U.S. cities and their surroundings. Distinct patterns emerge in the classification of seasonal daytime SUHII and nighttime SUHII. Specifically, the enhanced vegetation index (EVI) and albedo (ALB) play pivotal roles in influencing these temperature variations. The diurnal cycle of SUHII further reveals different trends, suggesting that climate conditions, urban and nonurban land covers, and anthropogenic activities during nighttime hours affect SUHII peaks. Exploring intracity LST dynamics, the study reveals a significant correlation between urban intensity (UI) and LST, with LST rising as UI increases. Notably, populations identified as more vulnerable by the social vulnerability index (SVI) are found in high UI regions. This results in discernible LST inequality, where the more vulnerable communities are under higher LST conditions, possibly leading to higher heat exposure. This comprehensive study accentuates the significance of tailoring city-specific climate change mitigation strategies, illuminating LST variations and their intertwined societal implications.

Environmental Sciences & Ecology↗

Stratocumulus cloud properties derived from simultaneous satellite and island-based instrumentation during FIRE

Cloud parameters derived from visible and infrared window data from the Geostationary Operational Environmental Satellite (GOES) are compared to corresponding properties determined from instrumentation on San Nicolas Island off the coast of California during the First ISCCP Regional Experiment marine stratocumulus intensive field observations period in July 1987. Examination of the satellite imagery revealed that the apparent bias can be explained by the persistence of the clouds over the northwest part of the island during periods of clearing around the island. Diurnal variations in the cloud cover were very significant; minimum cloudiness occurred during the late afternoon and maximum cloudiness early in the morning. Relationships were established between the satellite-derived cloud optical depth and two surface-observed quantities: cloud liquid water path and cloud thickness. Simultaneous observations of liquid water path and satellite-derived cloud optical depth were used to infer effective cloud-droplet radius, resulting in good agreement with correlative data. The diurnal variations in cloud amount are accompanied by changes in cloud thickness, cloud-top height, cloud liquid water path, and effective droplet size. These observations provide the most complete picture, to date, of the diurnal cycle of marine stratocumulus clouds, confirming previous satellite-based inferences of the diurnal behavior of marine stratocumulus at larger scales.

Minnis, Patrick↗

NANT Site - ASSIST / Thermodynamic retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Rochette et al. 2009) operated by NOAA Physical Sciences Laboratory on Nantucket Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the ASSIST housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗