Search NASA⌕ Search

SEARCH · Search NASA

Results for “isolate pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Photosystem II Water Oxidation: Mechanism, Efficiency and Flux in Diverse Oxygenic Phototrophs

In one year, we pursued four aims: 1) extend the VZAD model to allow analysis of PSII chlorophyll fluorescence emission as modulated by interaction with the WOC (partial success); 2) compare the solar energy conversion efficiencies of PSII-WOCs from intact cells, isolated thylakoid membranes and PSII core complexes and crystals from cyanobacterium Thermosynechococcus elongatus (collaboration with Lawrence Berkeley National Laboratory; some success after changing collaborator); 3) determine whether PSIIs can store light energy by pumping protons across the thylakoid membrane (PSII-cyclic electron flow) and how it is regulated within the green alga Chlorella ohadii (collaboration with the Hebrew University of Jerusalem; some success); and 4) genetically replace the native PSII-D1 protein subunit from a higher plant with two cyanobacterial D1 isoforms to test whether their functional advantages in growth and photoprotection can be transferred (collaboration with Rutgers University; success).

14 SOLAR ENERGY↗

Analysis of a second-order-accurate finite-volume method for temporally-growing compressible shear layers

A finite-volume method for solving the compressible laminar Navier-Stokes equation in two dimensions is assessed for use in the simulation of transitional flows. The method is second-order-accurate, uses alternating-direction-implicit time integration, and a total-variation-diminishing smoothing operator in the inviscid flux terms. The test problem was a free shear layer with a forced periodicity in x at a specified wavelength and with the parallel mean flow specified as a hyperbolic-tangent profile. A grid refinement investigation verified this method to be second-order-accurate with less than 4 percent error in the growth rate of isolated modes on a 32 by 64 grid. The interaction between modes of similar amplitude was small, less than 1 percent. However, in cases where there was a dominant mode, numerical phase error pumped energy into all other modes. This error results in nonphysical growth rate for modes whose energy content is several orders of magnitude below the dominant mode. In the case when the dominant mode saturates, the pumping action stops and the growth rate of the next largest growing mode regains physical significance.

Atkins, H. L.↗

The Summer of Hydrogen

Ground crew veterans at Kennedy Space Center still talk about what they call "the summer of hydrogen"-the long, frustrating months in 1990 when the shuttle fleet was grounded by an elusive hydrogen leak that foiled our efforts to fill the orbiter's external fuel tank. Columbia (STS-35) was on Launch Pad A for a scheduled May 30 launch when we discovered the hydrogen leak during - tanking. The external fuel tank is loaded through the orbiter. Liquid hydrogen flows through a 17-inch umbilical between the orbiter and the tank. During fueling, we purge the aft fuselage with gaseous nitrogen to reduce the risk of fire, and we have a leak-detection system in the mobile launch platform, which samples (via tygon tubing) the atmosphere in and around the vehicle, drawing it down to a mass spectrometer that analyzes its composition. When we progressed to the stage of tanking where liquid hydrogen flows through the vehicle, the concentration of hydrogen approached four percent-the limit above which it would be dangerously flammable. We had a leak. We did everything we could think of to find it, and the contractor who supplied the flight hardware was there every day, working alongside us. We did tanking tests, which involved instrumenting the suspected leak sources, and cryo-loaded the external tank to try to isolate precisely where the leak originated. We switched out umbilicals; we replaced the seals between the umbilical and the orbiter. We inspected the seals microscopically and found no flaws. We replaced the recirculation pumps, and we found and replaced a damaged teflon seal in a main propulsion system detent cover, which holds the prevalve-the main valve supplying hydrogen to Space Shuttle Main Engine 3 -in the open position. The seal passed leak tests at ambient temperature but leaked when cryogenic temperatures were applied. We added new leak sensors-up to twenty at a time and tried to be methodical in our placements to narrow down the possible sources of the problem. We even switched orbiters, sending Columbia back to the Vehicle Assembly Building and bringing out Atlantis, scheduled to fly as STS-38. Two shuttles on their mobile launchers passing in the night was a majestic sight, but not one you want to see if you're trying to get an orbiter launched. None of this told us where the leak was, or if we were dealing with more than one leak source.

Weber, Philip↗

Post-detonation fireball thermometry via femtosecond-picosecond coherent anti-Stokes Raman Scattering (CARS)

Accurate knowledge of post-detonation fireball temperatures is important for understanding device performance and for validation of numerical models. Such measurements are difficult to make even under controlled laboratory conditions. Here, temperature measurements were performed in the fireball of a commercial detonator (RP-80, Teledyne RISI). The explosion and fragments were contained in a plastic enclosure with glass windows for optical access. A hybrid femtosecond-picosecond (fs-ps) rotational coherent anti-Stokes Raman scattering (CARS) instrument was used to perform gas-phase thermometry along a one-dimensional measurement volume in a single laser shot. The 13-mm-thick windows on the explosive-containment housing introduced significant nonlinear chirp on the fs lasers pulses, which reduced the Raman excitation bandwidth and did not allow for efficient excitation of high-J Raman transitions populated at flame temperatures. To overcome this, distinct pump and Stokes pulses were used in conjunction with spectral focusing, achieved by varying the relative timing between the pump and Stokes pulses to preferentially excite Raman transitions relevant to flame thermometry. Light scattering from particulate matter and solid fragments was a significant challenge and was mitigated using a new polarization scheme to isolate the CARS signal. Fireball temperatures were measured 35–40 mm above the detonator, 12–25 mm radially outward from the detonator centerline, and at 18 and 28 µs after initiation. At these locations and times, significant mixing between the detonation products and ambient air had occurred thus increasing the nitrogen-based CARS thermometry signal. Initial measurements show a distribution of fireball temperatures in the range 300–2000 K with higher temperatures occurring 28 µs after detonation.

42 ENGINEERING↗

Guanidine Riboswitch-Regulated Efflux Transporters Protect Bacteria against Ionic Liquid Toxicity

Plant cell walls contain a renewable, nearly limitless supply of sugar that could be used to support microbial production of commodity chemicals and biofuels. Imidazolium ionic liquid (IIL) solvents are among the best reagents for gaining access to the sugars in this otherwise recalcitrant biomass. However, the sugars from IIL-treated biomass are inevitably contaminated with residual IILs that inhibit growth in bacteria and yeast, blocking biochemical production by these organisms. IIL toxicity is, therefore, a critical roadblock in many industrial biosynthetic pathways. Although several IIL-tolerant (IIL T ) bacterial and yeast isolates have been identified in nature, few genetic mechanisms have been identified. In this study, we identified two IIL T Bacillus isolates as well as a spontaneous IIL T Escherichia coli lab strain that are tolerant to high levels of two widely used IILs. We demonstrate that all three IIL T strains contain one or more pumps of the small multidrug resistance (SMR) family, and two of these strains contain mutations that affect an adjacent regulatory guanidine riboswitch. Furthermore, we show that the regulation of E. coli sugE by the guanidine II riboswitch can be exploited to promote IIL tolerance by the simple addition of guanidine to the medium. Our results demonstrate the critical role that transporter genes play in IIL tolerance in their native bacterial hosts. The study presented here is another step in engineering IIL tolerance into industrial strains toward overcoming this key gap in biofuels and industrial biochemical production processes.

09 BIOMASS FUELS↗

Degradation of TCE using sequential anaerobic biofilm and aerobic immobilized bed reactor

Bacteria capable of degrading trichloroethylene (TCE) were isolated from contaminated wastewaters and soil sites. The aerobic cultures were identified as Pseudomonas aeruginosa (four species) and Pseudomonas fluorescens. The optimal conditions for the growth of aerobic cultures were determined. The minimal inhibitory concentration values of TCE for Pseudomonas sps. were also determined. The aerobic cells were immobilized in calcium alginate in the form of beads. Degradation of TCE by the anaerobic and dichloroethylene (DCE) by aerobic cultures was studied using dual reactors - anaerobic biofilm and aerobic immobilized bed reactor. The minimal mineral salt (MMS) medium saturated with TCE was pumped at the rate of 1 ml per hour into the anaerobic reactor. The MMS medium saturated with DCE and supplemented with xylenes and toluene (3 ppm each) was pumped at the rate of 1 ml per hour into the fluidized air-uplift-type reactor containing the immobilized aerobic cells. The concentrations of TCE and DCE and the metabolites formed during their degradation by the anaerobic and aerobic cultures were monitored by GC. The preliminary study suggests that the anaerobic and aerobic cultures of our isolates can degrade TCE and DCE.

Chapatwala, Kirit D.↗

Evaluating cross-sectoral impacts of climate change and adaptations on the energy-water nexus: a framework and California case study

Abstract Electricity and water systems are inextricably linked through water demands for energy generation, and through energy demands for using, moving, and treating water and wastewater. Climate change may stress these interdependencies, together referred to as the energy-water nexus, by reducing water availability for hydropower generation and by increasing irrigation and electricity demand for groundwater pumping, among other feedbacks. Further, many climate adaptation measures to augment water supplies—such as water recycling and desalination—are energy-intensive. However, water and electricity system climate vulnerabilities and adaptations are often studied in isolation, without considering how multiple interactive risks may compound. This paper reviews the fragmented literature and develops a generalized framework for understanding these implications of climate change on the energy-water nexus. We apply this framework in a case study to quantify end-century direct climate impacts on California’s water and electricity resources and estimate the magnitude of the indirect cross-sectoral feedback of electricity demand from various water adaptation strategies. Our results show that increased space cooling demand and decreased hydropower generation are the most significant direct climate change impacts on California’s electricity sector by end-century. In California’s water sector, climate change impacts directly on surface water availability exceed demand changes, but have considerable uncertainty, both in direction and magnitude. Additionally, we find that the energy demands of water sector climate adaptations could significantly affect California’s future electricity system needs. If the worst-case water shortage occurs under climate change, water-conserving adaptation measures can provide large energy savings co-benefits, but other energy-intensive water adaptations may double the direct impacts of climate change on the state’s electricity resource requirement. These results highlight the value of coordinated adaptation planning between the energy and water sectors to achieve mutually beneficial solutions for climate resilience.

54 ENVIRONMENTAL SCIENCES↗

Space Shuttle Main Engine (SSME) LOX turbopump pump-end bearing analysis

A simulation of the shaft/bearing system of the Space Shuttle Main Engine Liquid Oxygen turbopump was developed. The simulation model allows the thermal and mechanical characteristics to interact as a realistic simulation of the bearing operating characteristics. The model accounts for single and two phase coolant conditions, and includes the heat generation from bearing friction and fluid stirring. Using the simulation model, parametric analyses were performed on the 45 mm pump-end bearings to investigate the sensitivity of bearing characteristics to contact friction, axial preload, coolant flow rate, coolant inlet temperature and quality, heat transfer coefficients, outer race clearance and misalignment, and the effects of thermally isolating the outer race from the isolator.

Source record↗

Method for producing components with internal architectures, such as micro-channel reactors, via diffusion bonding sheets

This invention relates to a method for producing components with internal architectures, and more particularly, this invention relates to a method for producing structures with microchannels via the use of diffusion bonding of stacked laminates. Specifically, the method involves weakly bonding a stack of laminates forming internal voids and channels with a first generally low uniaxial pressure and first temperature such that bonding at least between the asperites of opposing laminates occurs and pores are isolated in interfacial contact areas, followed by a second generally higher isostatic pressure and second temperature for final bonding. The method thereby allows fabrication of micro-channel devices such as heat exchangers, recuperators, heat-pumps, chemical separators, chemical reactors, fuel processing units, and combustors without limitation on the fin aspect ratio.

42 ENGINEERING↗

FLUOR HANFORD DECOMMISSIONING UPDATE

Fluor Hanford is completing D&D of the K East Basin at the U.S. Department of Energy's (DOE's) Hanford Site in southeastern Washington State this spring, with demolition expected to begin in June. Located about 400 yards from the Columbia River, the K East Basin is one of two indoor pools that formerly contained irradiated nuclear fuel, radioactive sludge and tons of contaminated debris. In unique and path-breaking work, workers finished removing the spent fuel from the K Basins in 2004. In May 2007, workers completed vacuuming the sludge into containers in the K East Basin, and transferring it into containers in the K West Basin. In December, they finished vacuuming the remainder of K West Basin sludge into these containers. The K East Basin was emptied of its radioactive inventory first because it was more contaminated than the K West Basin, and had leaked in the past. In October 2007, Fluor Hanford began physical D&D of the 8,400-square foot K East Basin by pouring approximately 14-inches of grout into the bottom of it. Grout is a type of special cement used for encasing waste. Two months later, Fluor Hanford workers completed sluicing contaminated sand from the large filter that had sieved contaminants from the basin water for more than 50 years. Next, they poured grout into the filter housing and the vault that surrounds the filter, as well as into ion exchange columns that also helped filter basin water. For a six-week period in February and March, personnel drained the approximately one million gallons of contaminated water from the K East Basin. The effort required more than 200 tanker truck loads that transported the water to an effluent treatment facility for treatment and then release. A thin fixative was also applied to the basin walls as the water was removed to hold residual contamination in place. As soon as the water was out of the basin, Fluor pumped in approximately 18 feet of 'controlled density fill' material (somewhat similar to sand) to shield workers to a safe level from the residual radioactivity. Workers then continued preparations for demolishing the structure. Currently, they are isolating utilities, removing asbestos, draining oils, and removing other items not allowed to be disposed in Hanford's Environmental Restoration Disposal Facility (ERDF). The basin's superstructure will be demolished using a heavy industrial excavator equipped with a shear. This portion of the work is expected to be completed in September, with removal of the basin substructure to follow in 2009. D&D of the K East Basin eliminated the final major radioactive sources there, and made the Columbia River and the adjacent environment safer for everyone who lives downstream.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

{sup 87}Rb D{sub 1} isoclinic point

In the research presented here, we reconsider the problem of obtaining stable resonant features in linear absorption spectroscopy, which has application to ultraminiature atomic physics where sub-Doppler spectroscopic techniques are not always optimal. In particular, we consider the applicability of isoclinic points for precision atomic spectroscopy. These are defined as ''[a] wavelength, wave number, or frequency at which the first derivative of an absorption spectrum of a sample does not change upon a chemical reaction or physical change of the sample,'' and we demonstrate the existence of isoclinic points in the D{sub 1} spectra of I=3/2 alkali-metal isotopes, where I is the nuclear spin. We then consider the D{sub 1} isoclinic point of {sup 87}Rb in detail, showing that a slight {sup 85}Rb contamination in real {sup 87}Rb samples should have no significant effect on the frequency stability of the isoclinic point and that optical pumping by a linearly polarized laser should also not affect the isoclinic point's stability (i.e., the isoclinic point is insensitive to laser intensity). Finally, we perform an experiment demonstrating that the {sup 87}Rb D{sub 1} isoclinic point has a temperature shift more than an order of magnitude smaller than that of the most isolated transition in the {sup 87}Rb D{sub 1} spectrum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Action at a distance: The remarkable coupling of CO 2 uptake to electron transfer in specialized cyanobacterial NDH-1 complexes

Cyanobacteria achieve highly efficient photosynthesis using a CO 2 -concentrating mechanism relying on specialized Type I (NDH-1) complexes. Among these, NDH-1 3 and NDH-1 4 catalyze redox-coupled hydration of CO 2 to bicarbonate, supporting carbon fixation in carboxysomes. The mechanism of coupling electron transfer to CO 2 -hydration by these variant NDH-1 complexes remains unknown. We engineered a Synechococcus PCC7942 strain that expresses exclusively the high flux/low affinity NDH-14 complex, enabling the observation of the coupling of CO 2 hydration to cyclic electron flow in isolation from the other NDH-1 isoforms normally present in cells. We found that inhibition of the CupB protein by the carbonic anhydrase inhibitor ethoxzolamide (EZ) suppressed CO 2 uptake, slowed photosystem I rereduction, and abolished proton pumping as probed by acridine orange fluorescence. These effects were absent in strains lacking Cup proteins, confirming specificity. The results demonstrate that CO 2 hydration and electron transfer through NDH-14 are tightly coupled via proton translocation across the thylakoid membrane. These findings provide direct evidence for the bidirectional interaction in bioenergetic coupling between the plastoquinone reduction and the CO 2 uptake at the distal Zn-site over a span of ~150 Å and support a proton-removal hypothesis involving the proton transfer pathways from the Zn-site of CO2 hydration to an energetically coupled proton loading site evolutionarily repurposed from the ancestral proton pumping mechanism to enable energetic CO 2 uptake.

59 BASIC BIOLOGICAL SCIENCES↗

Results of ultra compact plasma focus operating in repetitive burst-mode

The results of a miniature plasma focus are being presented in this paper which is operated with energy less than or equal to 150 Joules. The miniature plasma focus is driven by a small capacitor bank and the peak current delivered in the focus is 75kA. The deuterium gas is filled with a pressure range of 5-7 mbar inside the plasma focus chamber. The quartz glass is used for generating initial surface breakdown at 4-5 kV discharge which is a typical value for low-voltage plasma focus discharges. The repetitive operation of the device is achieved by a combination of a simple and high power (5 kW) power supply with the synchronized triggering of the capacitor bank at the time of isolation between supply and the capacitor bank. As the plasma focus chamber volume is very low, in order to achieve reduced after-shot contamination effects, the gas pressure inside the plasma focus is maintained by continuous pumping which is disallowed at the time of shorts rather having a sealed type plasma focus assembly. The results of such scheme are also discussed in the paper. The diameter of cathode is 25mm and anode diameter is 8-12 mm and both of them are made of stainless steel. The length of anode and gas pressure is adjusted in such a way that the pinching occurs at the time of occurrence of the peak of current. It enhances the neutron emission from the device. The time-of-flight diagnostic is used to distinguish neutron and X-ray emission from the plasma focus. The device can serve the purpose of being a portable and compact repetitive neutron source for various applications as the flux of the radiation is comparable with the bigger devices of same type. The modeling results of plasma focus are also compared with experimental results to give a broader picture of the device. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STATUS OF MECHANICAL SLUDGE REMOVAL AND COOLING COILS CLOSURE AT THE SAVANNAH RIVER SITE - F TANK FARM CLOSURE PROJECT - 9225

The Savannah River Site F-Tank Farm Closure project has successfully performed Mechanical Sludge Removal using the Waste on Wheels (WOW) system within two of its storage tanks. The Waste on Wheels (WOW) system is designed to be relatively mobile with the ability for many components to be redeployed to multiple tanks. It is primarily comprised of Submersible Mixer Pumps (SMPs), Submersible Transfer Pumps (STPs), and a mobile control room with a control panel and variable speed drives. These tanks, designated as Tank 6 and Tank 5 respectively, are Type I waste tanks located in F-Tank Farm (FTF) with a capacity of 2839 cubic meters (750,000 gallons) each. In addition, Type I tanks have 34 vertically oriented cooling coils and two horizontal cooling coil circuits along the tank floor. DOE intends to remove from service and operationally close Tank 5 and Tank 6 and other HLW tanks that do not meet current containment standards. After obtaining regulatory approval, the tanks and cooling coils will be isolated and filled with grout for long term stabilization. Mechanical Sludge Removal of the remaining sludge waste within Tank 6 removed {approx} 75% of the original 25,000 gallons in August 2007. Utilizing lessons learned from Tank 6, Tank 5 Mechanical Sludge Removal completed removal of {approx} 90% of the original 125 cubic meters (33,000 gallons) of sludge material in May 2008. The successful removal of sludge material meets the requirement of approximately 19 to 28 cubic meters (5,000 to 7,500 gallons) remaining prior to the Chemical Cleaning process. The Chemical Cleaning Process will utilize 8 wt% oxalic acid to dissolve the remaining sludge heel. The flow sheet for Chemical Cleaning planned a 20:1 volume ratio of acid to sludge for the first strike with mixing provided by the submersible mixer pumps. The subsequent strikes will utilize a 13:1 volume ratio of acid to sludge with no mixing. The results of the Chemical Cleaning Process are detailed in the 'Status of Chemical Cleaning of Waste Tanks at the Savannah River Site--F Tank Farm Closure Project--Abstract 9114'. To support Tank 5 and Tank 6 cooling coil closure, cooling coil isolation and full scale cooling coil grout testing was completed to develop a strategy for grouting the horizontal and vertical cooling coils. This paper describes in detail the performance of the Mechanical Sludge Removal activities and SMP operational strategies within Tank 5. In addition, it will discuss the current status of Tank 5 & 6 cooling coil isolation activities and the results from the cooling coil grout fill tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of hypokinesia on contractile function of cardiac muscle

Rats were subjected to hypokinesia for two months and the contractile function of isolated papillary muscle was studied. Hypokinesia reduced significantly the isotonic contraction rate which depended on the ATPase activity of the myofibrils; it also reduced the rate and index of relaxation which depended on the functional capacity of the Ca(++) pump of the sarcoplasmic reticulum. The maximum force of isometric contraction determined by the quantity of actomyosin bridges in the myofibrils did not change after hypokinesia. This complex of changes is contrary to that observed in adaptation to exercise when the rate of isotonic contraction and relaxation increases while the force of isometric contraction does not change. The possible mechanism of this stability of the contractile force during adaptation and readaptation of the heart is discussed.

Meyerson, F. Z.↗

The ISS 2B PVTCS Ammonia Leak: An Operational History

In 2006, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B power channel began leaking ammonia at a rate of approximately 1.5lbm/year (out of a starting approximately 53lbm system ammonia mass). Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity during the STS‐134 mission. During this mission the system was topped off with ammonia piped over from a separate thermal control system. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. Without these periodic EVAs to refill the 2B coolant system, the channel would eventually leak enough fluid as to risk pump cavitation and system failure, resulting in the loss of the 2B power channel - the most critical of the Space Station's 8 power channels. In mid‐2012, the leak rate increased to approximately 5lbm/year. Once discovered, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to a dormant thermal control system not intended to be utilized as anything other than spare components. The purpose of this rerouting of the TCS was to increase system volume and to isolate the photovoltaic radiator, thought to be the likely leak source. This EVA was successfully executed on November 1st, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a totally different radiator than what the system was designed to utilize. Unfortunately, data monitoring over the next several months showed that the isolated radiator was not leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, an EVA was in progress to replace the coolant pump - the only other replaceable leak source. This paper will explore the management of the 2B PVTCS leak from the operations perspective. It will discuss the methodology of performing the STS‐134 refill, the considerations and contingency plans which went into the architectural overhaul of the system in 2012, and the unprecedented effort which went into the EVA response to the visible leak of May 2013. In particular the paper will focus on the techniques utilized by flight controllers to monitor the system health and to respond to such instances as the rapid May 2013 leak by putting the electrical system in a safe configuration for loss of cooling, and will use recorded telemetry of these events to describe system response to EVA crew and ground actions. It will discuss the innovative design for redundancy of the integrated truss structure's cooling systems which allowed for this leak to be managed with minimal impact to other ISS operations and electrical services, contrasted against the real unintended operations consequences of utilizing the flexibility of the spacecraft's design in this manner. The paper will discuss how the training of the crew and flight controller personnel has adapted to the changing architecture of the power system and the unpredictable nature of the 2B leak.

Vareha, Anthony↗

Conformational changes in matrix-isolated 6-methoxyindole: Effects of the thermal and infrared light excitations

Conformational changes induced thermally or upon infrared excitation of matrix-isolated 6-methoxyindole were investigated. Narrowband near-infrared excitation of the first overtone of the N–H stretching vibration of each one of the two identified conformers is found to induce a selective large-scale conversion of the pumped conformer into the other one. This easily controllable bidirectional process consists in the intramolecular reorientation of the methoxy group and allowed a full assignment of the infrared spectra of the two conformers. Matrices with different conformational compositions prepared by narrow-band irradiations were subsequently used to investigate the effects of both thermal and broadband infrared excitations on the conformational mixtures. Particular attention is given to the influence of the matrix medium (Ar vs. Xe) and conformational effects of exposition of the sample to the spectrometer light source during the measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Brookhaven National Laboratory electron beam ion source for RHIC

As part of a new heavy ion preinjector that will supply beams for the Relativistic Heavy Ion Collider and the National Aeronautics and Space Administration Space Radiation Laboratory, construction of a new electron beam ion source (EBIS) is now being completed. This source, based on the successful prototype Brookhaven National Laboratory Test EBIS, is designed to produce milliampere level currents of all ion species, with q/m = (1/6)-(1/2). Among the major components of this source are a 5 T, 2-m-long, 204 mm diameter warm bore superconducting solenoid, an electron gun designed to operate at a nominal current of 10 A, and an electron collector designed to dissipate {approx} 300 kW of peak power. Careful attention has been paid to the design of the vacuum system, since a pressure of 10{sup -10} Torr is required in the trap region. The source includes several differential pumping stages, the trap can be baked to 400 C, and there are non-evaporable getter strips in the trap region. Power supplies include a 15 A, 15 kV electron collector power supply, and fast switchable power supplies for most of the 16 electrodes used for varying the trap potential distribution for ion injection, confinement, and extraction. The EBIS source and all EBIS power supplies sit on an isolated platform, which is pulsed up to a maximum of 100 kV during ion extraction. The EBIS is now fully assembled, and operation will be beginning following final vacuum and power supply tests. Details of the EBIS components are presented.

43 PARTICLE ACCELERATORS↗