Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

CY2020 Report for PECOS Activities

All experiments involving the Pecos target chamber in calendar year (CY) 2020 were dedicated to Pre-Heat studies in the context of Magnetized Liner Inertial Fusion (MagLIF). Activities at the target area included actual laser shots but also diagnostic and maintenance, and preparatory work for experiments with cryogenically cooled targets. The latter took up a large part of CY2020’s shot availability, and consequently there were fewer shots performed than in previous years. Since the Z-Beamlet and Z-Petawatt lasers support multiple campaigns, we can only anticipate laser and laser-operator time for one out of three shot windows in a day, and typically not on every day of the week. For that reason, many of our non-shot activities need to be traded against shots as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photodiode-based machine learning for optimization of laser powder bed fusion parameters in complex geometries

We report the quality of parts produced through laser powder bed fusion additive manufacturing can be irregular, with complex geometries sometimes exhibiting dimensional inaccuracies and defects. For optimal part quality, laser process parameters should be selected carefully prior to printing and adjusted during the print if necessary. This is challenging since approaches to control and optimize the build parameters need to take into account the part geometry, the material, and the complex physics of laser powder bed fusion. This work describes a data-driven approach using experimental diagnostics for the optimization of laser process parameters prior to printing. A training dataset is generated by collecting high speed photodiode signal data while printing simple parts containing key geometry features with various process parameter strategies. Supervised learning approaches are employed to train both a forward model and an inverse model. The forward model takes as inputs track-wise geometry features and laser parameters and outputs the photodiode signal along the scan path. The inverse model takes as inputs the geometry features and photodiode signal and predicts the laser parameters. Given the part geometry and a desired photodiode signal, the inverse model can thus determine the required laser parameters. Two test parts which contain defect-prone features are used to assess the validity of the inverse model. The use of the model leads to improved part quality (higher dimensional accuracy, reduced dross, reduced distortion) for both test geometries.

36 MATERIALS SCIENCE↗

Burst-mode dual-comb spectroscopy

We introduce a new modality of dual-comb spectroscopy that enables a simplified and powerful new approach for time-resolved measurements with increased acquisition rates. This "burst mode" form of dual-comb spectroscopy (BM-DCS) relies on the multiplexing of each probe pulse into a short train of pulses. With this approach we demonstrate a time-resolved series of absorption-based spectroscopic measurements of a laser-induced plasma using only a single laser ablation shot and identify 22 Nd lines not previously reported in the literature. The transmission spectra spanned 3.1 THz and were acquired at an effective acquisition rate of 25 kHz with 40 ms time-resolution. This simple modification to 100 MHz level dual-comb systems provides a flexible approach for studying transient and low duty-cycle events such as laser-induced plasmas, combustion, and explosive reactions.

(280.5395) Plasma Diagnostics, broadband laser spe↗

Implementation of a Doppler-Free Saturation Spectroscopy (DFSS) Diagnostic for Helicon Wave Electric Field Vector Measurement in Edge Plasma in DIII-D

A laser-based technique known as Doppler-free saturation spectroscopy (DFSS) has been designed, fabricated, and installed on the DIII-D National Fusion Facility to measure the helicon wave electric field vector in the edge plasma. These experimental measurements quantify phenomena resulting in decreased current drive efficiency due to wave/edge plasma interactions. This implementation of DFSS on DIII-D is the first of its kind on a tokamak and thus presents unique engineering challenges, including integration of the system onto an existing multidiagnostic port flange without impacts to system serviceability, as well as maintaining precise laser alignment over a 2-m distance during disruptions and thermal drift of the vessel. Further, these challenges were resolved using innovative design approaches such as a novel decoupled shutter system to facilitate serviceability of the in-vessel mirror assemblies without the need for personnel vessel entry, as well as an ex-vessel piezo-mirror-based optical system for laser beam shaping and real-time steering of the measurement location. The solutions to these engineering challenges were demonstrated during the successful installation and operation of these diagnostic components during the 2022 DIII-D vent and subsequent experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental capabilities of the LMJ-PETAL facility

In this study, recent progress in the experimental capabilities of the LMJ-PETAL laser facility is reviewed. Updates on the indirect-drive D 2 implosion experiments and equation-of-state experiments using the LMJ laser are presented, including the commissioning of new plasma diagnostics. Several recent campaigns using the PETAL laser alone are also presented, namely the development of a platform using high-resolution and high-energy X-ray sources for radiography experiments, laser wakefield acceleration studies in the self-modulated regime, and neutron generation using a Target Normal Sheath Accelerated proton beam in a pitcher-catcher configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A customizable data management framework for high-repetition-rate high-energy-density science

The high-energy-density (HED) physics community is moving toward a new paradigm of high-repetition-rate (HRR) operation. To fully leverage the scientific power of HRR HED facilities, all of the components of each subsystem (laser, targetry, and performance diagnostics) must be connected and synchronized in a reliable and robust manner while the data acquired are tagged and archived in real time. To this end, GA has begun developing a generalized NoSQL-database framework, the MongoDB repository for information and archiving. An organizational strategy has been developed that shifts HED data organization from a shot-based to a diagnostic-based approach in order to increase archival and retrieval efficiency that lends itself to optimization applications. This work is a first step in pushing HRR HED science toward data management solutions that emphasize machine actionability and aim to stimulate community engagement to define data standards in HED science.

Instruments & Instrumentation↗

A combined Phase Contrast Imaging and heterodyne interferometer for multiscale fluctuation measurements in tokamak plasmas

An upgrade to the Phase Contrast Imaging (PCI) diagnostic on the DIII-D tokamak has successfully combined PCI with density interferometry to provide electron density fluctuation measurements across an unprecedented range in wavenumber. The combined diagnostic uses a single laser and a single beam path through the tokamak, minimizing machine resources in anticipation of future reactor-scale devices where port access will be at a premium. The PCI multichannel detector provides low-noise, wavenumber-resolved detection of moderate-wavenumber turbulence, while the interferometer channel is sensitive to long-wavelength turbulence, including the peak of ion-scale turbulence and MHD. The overlap in wavenumber range between the two schemes allows for an in situ absolute calibration of the PCI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray-line coincidence photopumping in a potassium-chlorine mixed plasma

Exploiting the multiple long pulse capability and suite of x-ray diagnostics of the Orion laser, we have set out to explore line coincidence photopuming—the enhancement in population of an atomic level brought on by resonant absorption of x rays from a different emitting ion. Unlike previous work, the two ions are in the same plasma and so the experiment is an x-ray analog of the well-known Bowen resonance fluorescence mechanism that operates in astrophysical situations in the optical region. Herein, our measurements have shown enhanced fluorescence in a chlorine plasma, attributable to line coincident photopumping from co-mixed potassium ions. To detect this relatively low signal-to-noise phenomenon, the data from multiple shots are combined, and the statistical method of bootstrapping is used to assign a confidence value to the measured enhancement, resulting in an estimate of the enhancement of 39 ± 18 16 % compared to the null case, where no pumping occurs. The experimental results have been compared to coupled radiation-transport and radiation hydrodynamics simulations using the CRETIN code together with the NYM radiation hydrodynamics model and agreement has been found, with the simulations also predicting modest enhancement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Feasibility study for the hard x-ray free electron laser based on synergistic use of conventional and plasma accelerator technologies

Hard x-ray free electron lasers (XFELs) are great diagnostic tools in modern science. A number of XFELs have been constructed worldwide in the past decade. In the past, Los Alamos National Laboratory has expressed interest in hosting a similar facility to support ongoing Programs. The facility has been envisioned based on a conventional radio frequency (RF) accelerator technology. As a result, the estimated size and cost of the anticipated facility turned out to be large, which significantly decreased attractiveness of this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

S&TR July-August: Beyond Ignition

On December 5, 2022, Lawrence Livermore’s National Ignition Facility achieved the first-ever successful positive-gain ignition shot. This scientific advance, heralded worldwide, required a multidecadal effort to synthesize physics theory, laser technologies, computation and diagnostic capabilities, as well as engineering, materials development, and other inputs. The question, “Can ignition be achieved?” had been answered. Since then, the Laboratory has answered the question, “Can we do it again?” with additional ignition shots at increasing yield. Now Lawrence Livermore researchers ask, “Can we improve ignition outcomes?” for the benefit of the Stockpile Stewardship Program. Interrelated articles presenting the Laboratory’s ignition science, the role of supercomputing in achieving ignition, the evolution of diagnostic instruments to measure ignition data, and the ambitious steps required to realize a fusion energy future lead to one answer: “Yes, we can.”

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In Situ Laser Induced Florescence Measurements of Fuel Dilution from Low Load to Stochastic Pre Ignition Prone Conditions

This work employs a novel laser induced fluorescence (LIF) diagnostic to measure fuel dilution in a running single cylinder research engine operated at stochastic pre ignition (SPI) and non-SPI prone conditions. Measurements of LIF based fuel dilution are quantified over a range of engine loads and fuel injection timings for two fuels. The in situ LIF measurements of fuel/lubricant interactions illustrate regions of increased fuel dilution from fuel-wall interactions and is believed to be a fundamental underpinning to generating top ring zone liquid conditions conducive to SPI. Furthermore, a novel level of dye doped in the fuel, between 50 to 500 ppm was used as the fluorescence source, at engine operating speed of 2000r/min from 5 to 18 bar of IMEPg injection timings was swept for two fuels of varying volatility. The direct real time LIF measurements highlight that there are non-linear trends in fuel dilution beyond simple dependencies of fuel volatility, injection duration or injection timing, suggesting that further understanding of spray interaction with engine surfaces and the turbulent field are needed to quantify fuel dilution effects that are conducive to SPI. Moreover, results show the potential of this diagnostic technique as an additional tool for quantifying spray and fuel mixing in fundamental studies deployable across a variety of engine loads from law to full load.

47 OTHER INSTRUMENTATION↗

Infrared absorption spectroscopy of dynamically compressed water

Streaked visible spectroscopy is well established in dynamic compression research. Infrared measurements remain problematic, however, due to the diminishing sensitivity of streak camera photocathodes beyond 800 nm. Time-stretch techniques offer an alternative method for probing infrared features during single-event experiments. This paper discusses the development of a time-stretch spectroscopy diagnostic using dispersed supercontinuum laser pulses. The technique is applied to near-infrared measurements of liquid water during multiple shock compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared absorption spectroscopy of dynamically compressed water

Presentation describes development of a time-stretch spectroscopy diagnostic using dispersed supercontinuum laser pulses. The technique is applied to near-infrared measurements of liquid water during multiple shock compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fuel properties effects on wall-wetting and fuel-in-lube dilution under stochastic pre ignition prone conditions

Fuel-engine interactions have been shown to influence stochastic pre-ignition (SPI), however there is uncertainty on the root causes, participially if effects are primarily physical or chemical in nature. To better delineate the physical and chemical dependencies of fuel properties on SPI, this work studies interactions between aromatics, distillation, and particle matter index on SPI with a laser induced fluorescence (LIF) diagnostic to observe wall wetting. Fuels with high aromatic components or higher distillation temperatures tend to increase SPI events, but it is not well understood if the increased fuel dilution or a chemical aspect of this process is the primary mechanism for SPI. By employing the novel LIF in this work we measure fuel dilution in real-time in a running single cylinder research engine operated at SPI conditions. Three fuels were used in the present work, with the LIF diagnostic. Each fuel was operated at two injection timings, generating fuel specific effects on wall wetting. The LIF measurements are coupled with engine combustion measurements and SPI event counts. Results enable a deconvolution of fuel physical and chemical properties on SPI propensity, providing unique and novel insights into the dominant fuel effects affecting SPI.

Splitter, Derek↗