Directional solidification of silicon in carbon crucibles by an oscillating crucible technique

The quality of silicon cast by present techniques is limited by the presence of dislocations and grain boundaries in unseeded growth and by cellular structures with dislocation networks in the case of the seeded growth. To address these concerns, a new method of directional solidification called the oscillating crucible technique (OCT) is developed. During growth, a carbon crucible is oscillated to provide for effective stirring of the melt. This growth technique (seeded growth only), along with material characterization and solar-cell fabrication and testing, is described. Solar-cell efficiencies of up to 13 percent at 100 mW/sq cm area obtained in the single crystalline areas. Minority-carrier diffusion lengths exceeding 100 microns are measured even in the polycrystalline areas of the wafers. Limitations of the present setup and possible future improvements are discussed.

Daud, T.↗

Precision atomic beam density characterization by diode laser absorption spectroscopy

We provide experimental and theoretical details of a simple technique to determine absolute line-of-sight integrated atomic beam densities based on resonant laser absorption. In our experiments, a thermal lithium beam is chopped on and off while the frequency of a laser crossing the beam at right angles is scanned slowly across the resonance transition. A lock-in amplifier detects the laser absorption signal at the chop frequency from which the atomic density is determined. The accuracy of our experimental method is confirmed using the related technique of wavelength modulation spectroscopy. For beams which absorb of order 1% of the incident laser light, our measurements allow the beam density to be determined to an accuracy better than 5% and with a precision of 3% on a time scale of order 1 s. Fractional absorptions of order 10{sup −5} are detectable on a one-minute time scale when we employ a double laser beam technique which limits laser intensity noise. For a lithium beam with a thickness of 9 mm, we have measured atomic densities as low as 5 × 10{sup 4} atoms cm{sup −3}. The simplicity of our technique and the details we provide should allow our method to be easily implemented in most atomic or molecular beam apparatuses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of mass disorder on the lattice thermal conductivity of MgO periclase under pressure

Thermal conductivity of mantle materials controlling the heat balance and thermal evolution of the Earth remains poorly constrained as the available experimental and theoretical techniques are limited in probing minerals under the relevant conditions. We report measurements of thermal conductivity of MgO at high pressure up to 60 GPa and 300 K via diamond anvil cells using the time-domain thermoreflectance technique. These measurements are complemented by model calculations which take into account the effect of temperature and mass disorder of materials within the Earth. Our model calculations agree with the experimental pressure dependencies at 300 and 2000 K for MgO. Furthermore, they predict substantially smaller pressure dependence for mass disordered materials as the mechanism of scattering changes. The calculated thermal conductivity at the core-mantle boundary is smaller than the majority of previous predictions resulting in an estimated total heat flux of 10.4 TW, which is consistent with modern geomodeling estimates.

CONDENSED-MATTER PHYSICS↗

A multi-detector, digitizer based neutron depth profiling device for characterizing thin film materials

Neutron depth profiling (NDP) is a mature, nondestructive technique used to characterize the concentration of certain light isotopes in a material as a function of depth by measuring the residual energy of charged particles in neutron induced reactions. Historically, NDP has been performed using a single detector, resulting in low intrinsic detection efficiency, and limiting the technique largely to high flux research reactors. In this work, we describe a new NDP instrument design with higher detection efficiency by way of spectrum summing across multiple detectors. Such a design is capable of acquiring a statistically significant charged particle spectrum at facilities limited in neutron flux and operation time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PPI DataHub Project Data Package: S. elongatus PCC 7942 Limited Proteolysis and Thermal Proteome Profiling Structural Proteomics (JM-PB-DP3)

The purpose of this experiment was to investigate structural alterations in proteins involved in central carbon metabolism and photosynthetic electron transfer pathways in Synechococcus elongatus PCC 7942. Sample data was obtained from S. elongatus cell lysates using three complementary mass spectrometry (MS) techniques using limited proteolysis (LiP-MS), thermal proteome profiling (TPP-MS), and redox enrichment (Redox-MS) in evaluating alterations solvent accessibility and structural stability caused by light perturbation at the molecular level. Experimentally processed sample data for LiP and TPP proteomic datasets were derived from the same cell culture stock, prepared simultaneously in parallel, and acquired by mass spectrometry. Processed datasets are openly accessible from the download button and contain secondary processed proteomic results files, computed outputs, and supporting metadata materials. Experimental samples processed for LiP-MS label-free quantification (LFQ) or TPP-MS tandem mass tag (TMT) 10-plex were acquired using a Q-Exactive HF-X mass spectrometer and processed/compiled using either MSGF+ (v2024.03.26) or ​​​​PlexedPiper for proteome evaluation. Additional software supporting downstream proteomic analysis include FragPipe (v.4.0), MSFragger (v.22.1), and an adapted Microbial Isolate LiP Analysis Workflow (located at Zenodo). Processed proteomic data downloads include a sample naming key, normalized quantification results files, and processed protein annotated abundance files.

59 BASIC BIOLOGICAL SCIENCES↗

High-speed Synchrotron X-ray Imaging of Laser Powder Bed Fusion Process

In additive manufacturing (AM) processes, materials are selectively added in layer-wise fashion to build three-dimensional objects. This approach provides several advantages over conventional manufacturing, including the ability to manufacture complex parts, design flexibility, shorter lead times, reduced inventory of spares, and on-demand manufacturing [1]. With these advantages, applications of AM are increasing rapidly in the medical, aerospace, automobile, and defense industries [2, 3]. Currently, laser powder bed fusion (LPBF) is the most extensively used AM technique for manufacturing metal parts. In a typical LPBF process, a high-power laser beam is scanned across a thin layer of powder, melting and subsequently fusing it to the previous layer. Highly transient interactions between the laser, powder particles, and the bottom layer lead to defects in the AM materials. These defects include porosity, residual stresses, surface roughness, and undesirable microstructures [1, 4]. Additionally, several in situ techniques have been developed to capture these interactions in real time, including high-speed visible light and infra-red imaging [5]. However these techniques are limited to surface observations. Most of the important phenomena that govern the quality of the AM parts, such as dynamics of the vapor depression and melt pool, occur sub-surface and hence cannot be captured using traditional optical techniques. Recently, a synchrotron-based high-speed X-ray imaging technique has been developed to record the sub-surface dynamics of metallic materials during the LPBF process. The unprecedented spatial and temporal resolutions afforded by the synchrotron sources allow direct observation of many important phenomena in AM for the first time [6–9]. Further, high-speed X-ray diffraction and optical imaging techniques are also being applied to capture the crystallographic and thermal information of the material, respectively, as they undergo melting, solidification, and cooling [6, 9]. In this contribution, we introduce the recent developments at the Advanced Photon Source (APS) for in situ and operando study of LPBF processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology

The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 Å at 293 K and 79 Å at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging Fluorescence-Correlation Spectroscopy for Measuring Fast Surface Diffusion at Liquid/Solid Interfaces

The development of techniques to probe interfacial molecular transport is important for understanding and optimizing surface-based analytical methods including surface-enhanced spectroscopies, biological assays, and chemical separations. Single-molecule-fluorescence imaging and tracking has been used to measure lateral diffusion rates of fluorescent molecules at surfaces, but the technique is limited to the study of slower diffusion, where molecules must remain relatively stationary during acquisition of an image in order to build up sufficient intensity in a spot to detect and localize the molecule. Although faster time resolution can be achieved by fluorescence-correlation spectroscopy (FCS), where intensity fluctuations in a small spot are related to the motions of molecules on the surface, long-lived adsorption events arising from surface inhomogeneity can overwhelm the correlation measurement and mask the surface diffusion of the moving population. Here, we exploit a combination of these two techniques, imaging-FCS, for measurement of fast interfacial transport at a model chromatographic surface. This is accomplished by rapid imaging of the surface using an electron-multiplied-charged-coupled-device (CCD) camera, while limiting the acquisition to a small area on the camera to allow fast framing rates. The total intensity from the sampled region is autocorrelated to determine surface diffusion rates of molecules with millisecond time resolution. Here, the technique allows electronic control over the acquisition region, which can be used to avoid strong adsorption sites and thus minimize their contribution to the measured autocorrelation decay and to vary the acquisition area to resolve surface diffusion from adsorption and desorption kinetics. As proof of concept, imaging-FCS was used to measure surface diffusion rates, interfacial populations, and adsorption–desorption rates of 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine (DiI) on planar C18- and C1-modified surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differential imaging using charge-coupled device (CCD) imagers with on-chip charge storage

A CCD technique is described which allows long integration periods between readouts together with moderate chopping rates. During each phase of a differential chopping cycle, one set of charge images is shifted to the center of the chip, which is light sensitive. At the same time, the other set of charge images is shifted under one of two masked areas which serve as charge-storage sites. Since the vertical shifting between phases can be accomplished in much less time than the typical exposure per phase, there is negligible image smearing. For a given light level and chopping rate the performance of this technique is limited primarily by the readout noise and the vertical charge transfer inefficiency. If many transfer cycles are required between readouts, the charge transfer inefficiency will diffuse the accumulated charge images along the vertical columns. Laboratory and astronomical data obtained with this technique using a CCD camera and the 2.3 m telescope on Kitt Peak are presented.

Stockman, H. S.↗

APT Data Analysis towards Fission Products in TRISO Fuels

Tristructural isotropic (TRISO) particle is a promising candidate as fuel for high temperature gas reactors (HTGR) and other new generation fuel concepts like accident tolerant fuel for light water reactors. The TRISO coating is part of the HTGR functional containment and critical for the safety strategy for licensing purposes. The microstructure of TRISO particles typically consists of SiC and inner pyrolytic carbon (IPyC) layers, and has been an interesting topic, in particular, the behavior of fission products (FPs), such as Ag, Pd, etc. for many years. Historically, due to equipment and technique resolution limitations on radiological fuel materials, the distribution and behavior of FPs were not fully understood and resolved. Knowledge leapfrogged recently asAg-rich phase and Pd-rich precipitates were found along grain boundaries and inside SiC grains, respectively, by using scanning transmission electron microscopy (STEM) combined with energy dispersive x-ray spectrometry (EDS) and electron energy loss spectrometry (EELS) techniques [1]. However, as the Ag-rich phase and Pd-rich precipitate are much smaller than the STEM sample’s thickness, accurate quantitative analysis is difficult with TEM techniques. Furthermore, it is also extremely difficult to reveal the presence of other FPs in trace quantities. Atom probe tomography (APT) technique has been widely accepted and applied in the field of nuclear science, in particular for irradiated materials (e.g. ODS alloys), to reveal the distribution and composition of nano-sized features. However, there are very limited applications of APT towards studying FPs in fuels. Our preliminary results on neutron irradiated TRISO coated particles reveal a grain boundary containing multiple FPs [2]. This presentation will demonstrate though our study on the TRISO fuel sample how we identified the FPs in the SiC layer of the TRISO coated Particle, and challenged as FPs contains many unstable isotopes that are not shown in the CAMECA Periodic Table of the Isotopes for Atom Probe Tomography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Age validation of canary rockfish (Sebastes pinniger) using two independent otolith techniques: lead-radium and bomb radiocarbon dating.

Canary rockfish (Sebastes pinniger) have long been an important part of recreational and commercial rockfish fishing from southeast Alaska to southern California, but localized stock abundances have declined considerably. Based on age estimates from otoliths and other structures, lifespan estimates vary from about 20 years to over 80 years. For the purpose of monitoring stocks, age composition is routinely estimated by counting growth zones in otoliths; however, age estimation procedures and lifespan estimates remain largely unvalidated. Typical age validation techniques have limited application for canary rockfish because they are deep dwelling and may be long lived. In this study, the unaged otolith of the pair from fish aged at the Department of Fisheries and Oceans Canada was used in one of two age validation techniques: (1) lead-radium dating and (2) bomb radiocarbon ({sup 14}C) dating. Age estimate accuracy and the validity of age estimation procedures were validated based on the results from each technique. Lead-radium dating proved successful in determining a minimum estimate of lifespan was 53 years and provided support for age estimation procedures up to about 50-60 years. These findings were further supported by {Delta}{sup 14}C data, which indicated a minimum estimate of lifespan was 44 {+-} 3 years. Both techniques validate, to differing degrees, age estimation procedures and provide support for inferring that canary rockfish can live more than 80 years.

54 ENVIRONMENTAL SCIENCES↗

CHARACTERIZATION OF SAMPLES FROM TANK 16H ANNULUS

In support of the closure of Tank 16H, the remaining waste material in the tank annulus must be removed. Samples of the waste material from Tank 16H annulus were obtained and sent to Savannah River National Laboratory (SRNL) to determine the chemical and radiochemical composition prior to further waste removal. The three samples obtained from the Tank 16H annulus show some similarity as to the types of mineral phases present in the materials but differ in the relative amounts of each phase present. The samples from outside the dehumidification duct at two locations in the annulus show very different compositions and estimated solubility in water. This indicates the waste material in Tank 16H annulus may have a wide range of compositions at different locations. The table below provides a simplified description of the composition of each sample. The limited characterization techniques conducted and the complex mixture of materials in each sample makes assigning a definitive composition for each sample difficult. Given the variability in composition with just the three small samples characterized, a more detailed description of any single sample may be of limited value.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Technique for Simulating Conditions of Walking and Performing Other Self-Locomotive Activities on the Lunar Terrain

One of the most important and probably the most interesting phase of a manned lunar mission will be the time the astronauts spend outside their vehicle on the moon's surface taking scientific measurements, exploring the surface features, surveying possible sites for a lunar base, inspecting their vehicle and preparing it for their return trip. Because the lunar gravity is only one-sixth that of the earth gravity, the explorers undoubtedly will have to adjust their accustomed methods of walking, climbing, jumping and performing other self-locomotive activities in order to carry out these various tasks. In as much as the over-all success of the lunar mission will depend to a large extent upon the self-reliance of the explorers, it will be necessary to have extensive knowledge of the effects of the moon's reduced gravity on the physical capabilities of man and of man's ability to adopt to the new environment prior to the planning and execution of the mission. At the present time there is a dearth of information on this subject due primarily to the lack of a practical technique for simulating the reduced gravity. Several techniques such as immersion in water and riding in an airplane flying a Keplerian trajectory have been used for zero-g or weightlessness studies to determine the physical capabilities of man but these techniques are limited in their usefulness either by restrictions imposed by the viscous effect of the water or by the short duration and small test area available in an airplane. Consequently, an effort was made at the NASA Langley Research Center to devise a new technique that would provide a realistic simlation of a reduced gravity for unlimited periods of time and allow freedom of movement over considerable distances. This paper concerns itself with a discussion of the newly developed simulation technique and a presentation of some preliminary results which were obtained utilizing a working model based on this scheme.

Hewes, Donald E.↗

08-ERD-071 Final Report: New Molecular Probes and Catalysts for Bioenergy Research

A major thrust in bioenergy research is to develop innovative methods for deconstructing plant cell wall polymers, such as cellulose and lignin, into simple monomers that can be biologically converted to ethanol and other fuels. Current techniques for monitoring a broad array of cell wall materials and specific degradation products are expensive and time consuming. To monitor various polymers and assay their breakdown products, molecular probes for detecting specific carbohydrates and lignins are urgently needed. These new probes would extend the limited biochemical techniques available, and enable realtime imaging of ultrastructural changes in plant cells. Furthermore, degradation of plant biomass could be greatly accelerated by the development of catalysts that can hydrolyze key cell wall polysaccharides and lignin. The objective of this project was to develop cheap and efficient DNA reagents (aptamers) used to detect and quantify polysaccharides, lignin, and relevant products of their breakdown. A practical goal of the research was to develop electrochemical aptamer biosensors, which could be integrated into microfluidic devices and used for high-throughput screening of enzymes or biological systems that degrade biomass. Several important model plant cell wall polymers and compounds were targeted for specific binding and purification of aptamers, which were then tested by microscopic imaging, circular dichroism, surface plasmon resonance, fluorescence anisotropy, and electrochemical biosensors. Using this approach, it was anticiated that we could provide a basis for more efficient and economically viable biofuels, and the technologies established could be used to design molecular tools that recognize targets sought in medicine or chemical and biological defense projects.

09 BIOMASS FUELS↗

Medical and surgical applications of space biosensor technology

Researchers in space life sciences are rapidly approaching a technology impasse. Many of the critical questions on the impact of spaceflight on living systems simply cannot be answered with the limited available technologies. Research subjects, particularly small animal models like the rat, must be allowed to function relatively untended and unrestrained for long periods to fully reflect the impact of microgravity and spaceflight on their behavior and physiology. These requirements preclude the use of present hard-wired instrumentation techniques and limited data acquisition systems. Implantable sensors and miniaturized biotelemetry are the only means of capturing the fundamental and critical data. This same biosensor and biotelemetry technology has direct application to Earth-based medicine and surgery. Continuous, on-line data acquisition and improved measurement capabilities combined with the ease and flexibility offered by automated, wireless, and portable instruments and data systems, should provide a boon to the health care industry. Playing a key role in this technology revolution is the Sensors 2000! (S2K!) Program at NASA Ames Research Center. S2K!, in collaboration with space life sciences researchers and managers, provides an integrated capability for sensor technology development and applications, including advanced biosensor technology development, spaceflight hardware development, and technology transfer and commercialization. S2K! is presently collaborating on several spaceflight projects with dual-use medical applications. One prime example is a collaboration with the Fetal Treatment Center (FTC) at the University of California at San Francisco. The goal is to develop and apply implantable chemical sensor and biotelemetry technology to continuously monitor fetal patients during extra-uterine surgery, replacement into the womb, through birth and beyond. Once validated for ground use, the method will be transitioned to spaceflight applications to remotely monitor key biochemical parameters in flight animals. Successful application of NASA implantable biosensor and biotelemetry technologies should accelerate the advancement of this and other modern medical procedures while furthering the exploration of life in space.

NASA Discipline General Space Life Sciences↗

Ultra-thin on-chip ALD LiPON capacitors for high frequency application

Multi-layer ceramic capacitors have been used for high frequency decoupling application due to a lower overall impedance leading to fast current response. However, high parasitic inductance limits the application of these capacitors in ultra-high frequency domain. Thus, Multlayer Ceramic Capacitors (MLCCs) are placed close to the IC to improve circuit efficiency and reduce inductance. With next generation applications, the demand for frequency range has further increased which not only requires enhanced capacitor material but improved manufacturing techniques to limit the inductive path. Here, we demonstrate ALD of two different polymorphs of ultra-thin film lithium phosphorus oxynitride (LiPON) as an inorganic solid state electrolyte (SSE) for on chip capacitors for decoupling application. Both the LiPON capacitors shows an electric double layer behavior with a capacitance of 15 μF/cm 2 and a low leakage current (<20 nA/cm 2 ) at 2V. The LiPON shows EDLC behavior up to 10 kHz and beyond, both the polymorphs show an electrostatic behavior with a high dielectric constant (14). Furthermore, this dual frequency behavior along with low parasitic inductance and on chip integration allows for operation in extended frequency ranges.

25 ENERGY STORAGE↗

Prediction of drag at subsonic and transonic speeds using Euler methods

A technique for the evaluation of aerodynamic drag from flowfield solutions based on the Euler equations is discussed. The technique is limited to steady attached flows around three-dimensional configurations in the absence of active systems such as surface blowing/suction and propulsion. It allows the decomposition of the total drag into induced drag and wave drag and, consequently, it provides more information on the drag sources than the conventional surface-pressure integration technique. The induced drag is obtained from the integration of the kinetic energy (per unit distance) of the trailing vortex system on a wake plane and the wave drag is obtained from the integration of the entropy production on a plane just downstream of the shocks. The drag-evaluation technique is applied to three-dimensional flowfield solutions for the ONERA M6 wing as well as an aspect-ratio-7 wing with an elliptic spanwise chord distribution and an NACA-0012 section shape. Comparisons between the drag obtained with the present technique and the drag based on the integration of surface pressures are presented for two Euler codes.

Nikfetrat, K.↗

Upgrading Limiting Peak-Power Analysis Techniques with Modern Validation and Uncertainty Quantification for the Advanced Test Reactor

Here, this work demonstrates the acceptability of the 2D deterministic transport code, HELIOS, to replace the legacy diffusion code, PDQ, for computing the peak-power performance parameters of the Advanced Test Reactor (ATR). The 95% Confidence Rule, commonly used in the commercial reactor sector, is explored to develop the so-called “reliability factors” which provide statistical confidence that the peak-power limits within the hottest location along a fuel plate, referred to as the hot-stripe, will not be exceeded. Additionally, an alternative “legacy” methodology was explored that attempts to mimic the exact PDQ analysis process used for defining the peak-power limits. The legacy methodology, involves interpolating power between regions at azimuthal boundaries subtending the regions of interest. In order to apply the 95% Confidence Rule, a statistically significant calculation-to-measurement bias must first be established. Unlike the commercial world where thousands of power observations can be collected every cycle using on-line flux mapping instrumentation, the ATR power distribution must be measured during “depressurized” zero-power measurements using fission wires in polyethylene wands. In 2012, fission wire activation data was collected during a flux run in the Advanced Test Reactor – Critical facility. Also to improve statistical validity, archival data from ATR zero power flux runs from 1977, 1986, and 1994 were digitized from scanned reports and used to create new benchmark models. Borrowing from least-squares adjustment methods commonly used for neutron activation spectroscopy, adjusted fission wire powers were calculated for all four datasets. The mean and standard deviation of the bias between a priori calculated and adjusted wire-powers was then taken as the bias and uncertainty used in the 95% Confidence Rule.