LCLS Big Data Handling – How I Learned to Stop Worrying and Love the Data Deluge

Advanced data and computing systems are vital to Linac Coherent Light Source (LCLS) operations, data interpretation and overall scientific productivity. The transition to MHz-era operation marks a fundamental change in scale that requires new infrastructure and architectures to link LCLS to the required scale of computing needed for scientific interpretation. The LCLS-II Data System meets big data challenges by implementing configurable data reduction that can adapt to multiple science areas, real-time analysis frameworks to provide visualization and fast feedback, and the ability to transfer data to local and remote computational facilities for near real time analysis at the appropriate scale. Feature extracted information generated in the data analysis pipeline - at the edge, local compute, or remote High-Performance Computing (HPC) resources - can be used to steer experiments and inform user decisions during beam time. Artificial Intelligence and Machine Learning (AI/ML) techniques present new opportunities to rapidly analyse large datasets and direct experiments, but create new challenges in scaling, adaptability, complexity, and trustworthiness. We describe how the LCLS-II Data System architecture addresses its data-driven challenges in the areas of data acquisition, data processing, data management, and workflow orchestration to decrease the overall time-to-science and provide a vision for future developments.

artificial intelligence↗

Quantitative x-ray scattering of free molecules

Advances in x-ray free electron lasers have made ultrafast scattering a powerful method for investigating molecular reaction kinetics and dynamics. Accurate measurement of the ground-state, static scattering signals of the reacting molecules is pivotal for these pump-probe x-ray scattering experiments as they are the cornerstone for interpreting the observed structural dynamics. Here, this article presents a data calibration procedure, designed for gas-phase x-ray scattering experiments conducted at the Linac Coherent Light Source x-ray Free-Electron Laser at SLAC National Accelerator Laboratory, that makes it possible to derive a quantitative dependence of the scattering signal on the scattering vector. A self-calibration algorithm that optimizes the detector position without reference to a computed pattern is introduced. Angle-of-scattering corrections that account for several small experimental non-idealities are reported. Their implementation leads to near quantitative agreement with theoretical scattering patterns calculated with ab-initio methods as illustrated for two x-ray photon energies and several molecular test systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION↗

Heat load measurements for the PIP-II pHB650 cryomodule

Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of testing and to continue pinpointing any sources of unexpectedly high heat loads.. The programme measured HTTS, LTTS, and 2 K isothermal/non-isothermal loads under "standard", "linac", and "simulated dynamic" operating modes, recording data both inside the cryomodule and across the bayonet can circuits. Thermal-acoustic oscillations were eliminated by replacing the original G10 cooldown-valve stem with a stainless-steel stem fitted with wipers. A newly developed Python script automated acquisition of ACNET data, performed real-time heat-load calculations, and generated plots and tables that were posted to the electronic logbook within minutes, vastly reducing manual effort and accelerating feedback between SRF and cryogenics teams. Analysis showed that JT heat-exchanger effectiveness and temperature stratification in the two-phase and relief piping strongly influence the observed loads and helped isolate sources of excess heat. The campaign demonstrates that rigorous pre-test planning, real-time diagnostics, and automated reporting can improve both accuracy and efficiency, providing a template for future PIP-II cryomodule tests and for implementing targeted heat-load mitigations.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.] (ORCID:↗

Accelerating data acquisition with FPGA-based edge machine learning: a case study with LCLS-II

New scientific experiments and instruments generate vast amounts of data that need to be transferred for storage or further processing, often overwhelming traditional systems. Edge machine learning (EdgeML) addresses this challenge by integrating machine learning (ML) algorithms with edge computing, enabling real-time data processing directly at the point of data generation. EdgeML is particularly beneficial for environments where immediate decisions are required, or where bandwidth and storage are limited. In this paper, we demonstrate a high-speed configurable ML model in a fully customizable EdgeML system using a field programmable gate array (FPGA). Our demonstration focuses on an angular array of electron spectrometers, referred to as the ‘CookieBox,’ developed for the Linac Coherent Light Source II project. The EdgeML system captures 51.2 Gbps from a 6.4 GS s −1 analog to digital converter and is designed to integrate data pre-processing and ML inside an FPGA. Our implementation achieves an inference latency of 0.2 µs for the ML model, and a total latency of 0.4 µs for the complete EdgeML system, which includes pre-processing, data transmission, digitization, and ML inference. The modular design of the system allows it to be adapted for other instrumentation applications requiring low-latency data processing.

97 MATHEMATICS AND COMPUTING↗

Inverse model based error detection in beamline optics

Optics tuning in transfer lines and LINACs can be challenging due to the fact that multiple combinations of machine settings can lead to the same diagnostic output. Moreover, the lack of a periodic solution can limit the ability to infer optics in the same way as rings from BPM signals. Model based approaches are often used to assist with the optics tuning in combination with optimization or parameter estimation. Here we have developed a novel approach using machine learning inverse models trained on a known configuration to detect variations in quadrupole settings without explicitly including them in the model. This paper shows a comparison of neural network models and linear models on both a simulation based study and experimental studies conducted at the AGS to RHIC transfer line at Brookhaven National Lab.

43 PARTICLE ACCELERATORS↗

Fingerprints of Triaxiality in the Charge Radii of Neutron-Rich Ruthenium

We present the first measurements with a new collinear laser spectroscopy setup at the Argonne Tandem Linac Accelerator System, utilizing its unique capability to deliver neutron-rich refractory metal isotopes produced by the spontaneous fission of 252 Cf. We measured isotope shifts from optical spectra for nine radioactive ruthenium isotopes 106–114 Ru, reaching deep into the mid-shell region. The extracted charge radii are in excellent agreement with predictions from the Brussels-Skyrme-on-a-Grid models that account for the triaxial deformation of nuclear ground states. We show that triaxial deformation impacts charge radii in models that feature shell effects, in contrast to what could be concluded from a liquid drop analysis. This indicates that this exotic type of deformation should not be neglected in regions where it is known to occur, even if its presence cannot be unambiguously inferred through laser spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wakefield generation in hydrogen and lithium plasmas at FACET-II: Diagnostics and first beam-plasma interaction results

Plasma wakefield acceleration provides ultrahigh acceleration gradients of tens of GeV/m, providing a novel path toward efficient, compact, TeV-scale linear colliders, and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single-stage plasma wakefield accelerator, providing a 10 GeV energy gain in a < 1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm mrad accuracy, energy spectra to determine both percent level energy spread, and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed as well as commissioning of the plasma sources and diagnostics. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Dual-energy electron storage ring

A dual-energy electron storage ring is a novel concept initially proposed to cool hadron beams at high energies. The design consists of two closed rings operating at significantly different energies: the low-energy ring and the high-energy ring. These two rings are connected by an energy recovery linac (ERL) that provides the necessary energy difference. The ERL features superconducting radio-frequency (SRF) cavities that first accelerate the beam from the low energy E L to the high energy E H and then decelerate the beam from E H to E L in the next pass. The different SRF cavities in the ERL section can be adjusted based on the applications. In this paper, we present a possible layout of a dual-energy electron storage ring. The preliminary optics of the ring is designed to optimize chromaticity correction, dynamic aperture, momentum aperture, beam lifetime, radiation damping, and intrabeam scattering effects. The primary focus of this paper is on the stability conditions and beam dynamics studies associated with this storage ring. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrotemporal Shaping of Attosecond X-Ray Pulses with a Fresh-Slice Free-Electron Laser

We propose a scheme allowing coherent shaping, i.e., controlling both the amplitude and phase, of attosecond x-ray pulses at free-electron lasers. Here, we show that by seeding an FEL with a short coherent seed that overfills the amplification bandwidth, one can shape the Wigner function of the pulse by controlling the undulator taper profile. The examples of controllable pulse pairs and trains, as well as isolated spectrotemporally shaped pulses with very broad bandwidths are examined in detail. Existing attosecond XFELs can achieve these experimental conditions in a two-stage cascade, in which the seed is generated by a short current spike in an electron bunch and shaped in an unspoiled region within the same bunch. We experimentally demonstrate the production and control of phase-stable pulse trains using this method at the Linac Coherent Light Source II.

47 OTHER INSTRUMENTATION↗

Three-dimensional theory of superradiant free-electron lasers

The solitonlike superradiant regime of free-electron lasers (FEL) offers a promising path towards ultrashort pulses, beyond the natural limit dictated by the bandwidth of the high-gain FEL instability. In this work we present a three-dimensional theory of the superradiant regime, including the effects of beam emittance and energy spread. Our work takes advantage of recent developments in nonlinear FEL theory to provide a fully analytical description of solitonlike superradiance. Our theory proves the existence of a diffraction-dominated steady-state regime in which the superradiant peak power grows indefinitely while leaving the pulse duration and on-axis intensity almost unchanged. These results are in excellent agreement with three-dimensional simulations and are supported by recent experimental results at the Linac Coherent Light Source. This work advances nonlinear FEL theory and provides a theoretical framework for the next generation of attosecond x-ray FELs. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

A Two-Dimensional Non-Linear Magnetic Equivalent Circuit Model to Facilitate the Preliminary Design of a Normal Conducting Quadrupole

Normal conducting quadrupoles have been used to focus charged particle beams in synchrotrons, beam transfer lines, medical linacs, etc. for a long time. Optimization techniques based on analytical expressions combined with the use of a numerical field analysis tool exist in the literature for the design of an optimal pole tip shape. However, the initial shape and dimensions of the remaining yoke (including the pole itself and yoke base that act as the return path) are usually less well defined. This article discusses a design methodology for a normal conducting quadrupole based on a two-dimensional magnetic equivalent circuit. Here, this approach considers the geometry of the entire magnet and the non-linear behavior of the yoke material, thereby eliminating the initial iterations. The design outcome of this exercise serves as a competent starting point and can then be used to refine the pole tip, pole taper, yoke size, and add other geometrical features to achieve the required field quality, gradient, coil considerations, etc. by employing a finite element analysis tool. An example design study to demonstrate the proposed methodology is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep learning-assisted modeling for χ (2) nonlinear optics

Modeling second-order (χ(2)) nonlinear optical processes remains computationally expensive due to the need to resolve fast field oscillations and simulate wave propagation using methods such as the split-step Fourier method (SSFM). This can become a bottleneck in real-time applications, such as high-repetition-rate laser systems requiring rapid feedback and control. We present a long short-term memory-based surrogate model trained on SSFM simulations generated from a start-to-end model of the photocathode drive laser at SLAC National Accelerator Laboratory’s Linac Coherent Light Source II. The model achieves over 250× speedup while maintaining high fidelity, enabling future real-time optimization and laying the foundation for data-integrated modeling frameworks and digital twins of laser systems.

Accelerator Physics (physics.acc-ph)↗

Establishing Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory

Background: Promising developments in Pb-212 radiopharmaceutical therapies have increased demand for Pb-203 diagnostic agents. Building on previous work from various isotope production facilities, this study optimized Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory (BNL). The additional supply of Pb-203 may help meet growing preclinical and clinical demands. Results: Two Tl targets were irradiated at the Brookhaven Linac Isotope Producer facility with 30 ± 1 MeV protons, measured using previously published cross section data. Distribution coefficients for Pb Resin in acetate media were investigated for both Na + and K + cations, where potassium acetate was ~ 4 times more effective at stripping Pb from the Pb Resin. The Tl electrodeposition was optimized to deposit 350 mg of Tl (~ 60 mg/cm 2 ) on Au backing in under 6 h. The proposed separation process was completed in < 1.5 h and achieved > 98% and 92 ± 3% recovery of Tl and Pb, respectively, with an overall Tl-Pb separation factor of 6 × 10 5 . The experimentally measured half-life of Pb-203 was 52.4 ± 0.7 h, agreeing with 51.93 ± 0.02 h reported by the National Nuclear Data Center. The radioisotopic purity of the Pb fraction at 24 h post end of bombardment (EOB) from a 24 h irradiation was 66% Pb-203, 28% Pb-201, and 6% Pb-200. Following chemical separation, the Pb-203 produced in this work (21 MBq Pb-203 EOB) achieved apparent molar activities of 10 ± 5 and 0.9 ± 0.5 GBq/µmol for [ 203 Pb]Pb-DOTAM and [ 203 Pb]Pb-DO3A, respectively, decay corrected to EOB. Data derived from this work suggests BNL can produce > 10’s GBq Pb-203 with > 99% radiochemical and radioisotopic purity from Tl-205 for worldwide distribution. Conclusions: The production and separation of Pb-203 from natural Tl target material was successfully demonstrated at BNL. Existing methods were adapted and optimized for the facilities at BNL. Results from this work will guide future large-scale Pb-203 production opportunities at BNL for clinical applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Image mapping for multiple charge state beams using a beam induced fluorescence profile monitors

Work continues on a minimally invasive, nitrogen fluorescence gas sheet at the Facility for Rare Isotope Beams (FRIB). A low density gas sheet may be used to observe the 2D transverse beam profile of high intensity, multiple charge state beams with minimal interference. Spatially and temporally correlated profiles are of particular interest in locations where there is significant charge state spread, such as the FRIB linac folding segments. A low-density gas sheet measurement system offers advantages for gas handling in nitrogen sensitive areas, however signal intensity is significantly lower than techniques using higher density gas sheets and jets. This work discusses measurement considerations for photon distributions generated by several spatially separated interaction points and design considerations for a high-sensitivity optics system for handling the expected low signal intensity.

Accelerator Physics↗