Search NASA⌕ Search

SEARCH · Search NASA

Results for “load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

Renal vascular control during normothermia and passive heat stress does not differ between healthy younger men and women

The mechanisms underlying greater heat-induced acute kidney injury risk in men versus women remain unknown. This study examined renal vascular control, including both vasodilatory (oral protein load) and vasoconstrictor (cold presser test) responses, during normothermia and heat stress and compared these responses between men and women. The results indicated that in both conditions neither renal vasodilatory nor vasoconstrictor responses differ between younger men and younger women.

Physiology↗

UMap: An application-oriented user level memory mapping library

Exploiting the prominent role of complex memories in exascale node architecture, the UMap page fault handler offers new capabilities to access large memory-mapped data sets directly. UMap provides flexible configuration options to customize page handling to each application, including analysis of massive observational and simulation data sets. The high-performance design features I/O decoupling, dynamic load balancing, and application-level controls. Page faults triggered by application threads and processes accessing data mapped to a UMapp’ed region are handled via the Linux userfaultfd protocol, an asynchronous message-oriented kernel-user communication mechanism that avoids the context switch penalty of traditional signal fault handlers. UMap is fully open source. In this paper, we give an overview of the UMap library architecture, its extensible plugin architecture, and the use/performance of UMap in emerging heterogeneous memory hierarchies such as near-node Non-volatile Memory (NVM) and network attached memories. We highlight new capabilities in two pagefault management plugins, the NetworkStore and SparseStore. We demonstrate the integration between UMap and multiple ECP products including Caliper, Metall, ZFP, Mochi, and Ripples.

97 MATHEMATICS AND COMPUTING↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

High Frequency Monitoring and Nitrate Sourcing Reveals Baseflow and Stormflow Controls on Total Dissolved Nitrogen and Carbon Export Along a Rural‐Urban Gradient

Abstract Efforts to reduce nitrogen and carbon loading from developed watersheds typically target specific flows or sources, but across gradients in development intensity there is no consensus on the contribution of different flows to total loading or sources of nitrogen export. This information is vital to optimize management strategies leveraging source reductions, stormwater controls, and restorations. We investigate how solute loading and sources vary across flows and land‐use using high frequency monitoring and stable nitrate isotope analysis from five catchments with different sanitary infrastructure, along a gradient in development intensity. High frequency monitoring allowed estimation of annual loading and attribution to storm versus baseflows. Nitrate loads were 16 kg/km 2 /yr. from the forested catchment and ranged from 68 to 119 kg/km 2 /yr., across developed catchments, highest for the septic served site. Across developed catchments, baseflow contributions ranged from 40% of N loading to 75% from the septic served catchment, and the contribution from high stormflows increased with development intensity. Stormflows mobilized and mixed many surface and subsurface nitrate sources while baseflow nitrate was dominated by fewer sources which varied by catchment (soil, wastewater, or fertilizer). To help inform future sampling designs, we demonstrate that grab sampling and targeted storm sampling would likely fail to accurately predict annual loadings within the study period. The dominant baseflow loads and subsurface stormflows are not treated by surface water management practices primarily targeted to surface stormflows. Using a balance of green and gray infrastructure and stream/riparian restoration may target specific flow paths and improve management.

Delesantro, Joseph M.↗

Object-Oriented Controllable High-Resolution Residential Energy (OCHRE) (TM) Model

This presentation describes the OCHRE model as part of NREL's Powered By webinar series. OCHRE is a building energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, electric vehicles, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Early Research in Load-Following Management for HPC-Nuclear Integration

With the rising demand for high performance computing (HPC) and artificial intelligence (AI) systems, maintaining a stable and efficient power supply is increasingly critical. The HPC team at Idaho National Laboratory is spearheading efforts to seamlessly integrate HPC systems with nuclear reactors. This lightning talk explores one early strategy for managing power fluctuations using software-defined controls. To effectively harness nuclear reactors for power generation, control mechanisms are essential to address the slow load-following capabilities of reactors, which are typically around 5% per minute. While this rate is sufficient for many uses, large HPC systems can experience rapid power consumption changes by tens of megawatts when jobs start or stop running. A reactor could overproduce power and match the peak power rating for the HPC system, however when the system is not running a job or a job unexpectedly stops, the load-following of the system would be affected leading to power being wasted and the likelihood of power transient occurrences increases. Controlling the increase or decrease of power consumption on these systems at the same rate as the load-following of reactors is one piece of the puzzle to properly utilizing nuclear reactors as a power source for HPC systems.

97 - MATHEMATICS AND COMPUTING↗

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration: Preprint

This paper presents an innovative wave energy conversion system employing an interleaved Cuk converter and advanced nonlinear control for seamless integration with the grid. The proposed system utilizes the interleaved Cuk converter for efficient power extraction on the DC side, while an inverter facilitates power transfer to the grid or load on the AC side. A sophisticated nonlinear control architecture based on Lyapunov energy functions ensures stable and optimal operation under varying wave conditions. Case study results demonstrate the effectiveness of the proposed system, highlighting its ability to efficiently harness wave energy and seamlessly integrate with the grid, thus paving the way for sustainable and reliable renewable energy generation. The overall system is verified via computer simulations based on MATLAB/Simulink and various case study results are presented.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Cyberattack Detection and Mitigation on Central Volt‐VAr Using Circuit Law and Machine Learning

ABSTRACT In a distribution grid, voltage is maintained within a nominal range through a Volt‐VAr function that controls capacitor banks, reactive power of distributed energy resources (DER), and on‐load tap changers (OLTC). Availability of communications helps with the implementation of central Volt‐VAr control; however, it also opens the system to cyberattacks, causing voltage disturbances. Previous work has shown the adverse impacts of false data injection (FDI) on the central Volt‐VAr control; however, very few works have studied methods to detect and mitigate FDI on Volt‐VAr control. This paper addresses gaps in the detection and mitigation of FDI on the measurement packets of a central Volt‐VAr control. This work uses a two‐stage algorithm for cyberattack detection since the accuracy of a single‐stage machine learning (ML)–based detection method decreases while dealing with unseen data. The first stage is based on the verification of measurements against circuit laws, and the second stage utilizes a tree search algorithm and an ML method to detect the falsified data. This paper compares long short‐term memory (LSTM) and bidirectional LSTM (BiLSTM) as the employed ML algorithms. Finally, the mitigation algorithm replaces the falsified data with the estimated output of the ML algorithm. The effectiveness of the proposed method is tested for several cases using the IEEE 13‐bus test system in PSCAD software.

Beikbabaei, Milad [Bradley Department of Electrica↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Trade-Off Study Between the Primary and Transient Responses of Grid-Forming Inverters

The control parameters of the grid-forming (GFM) inverter-based resources (IBRs) directly impact power system dynamics. The primary control requires the GFM inverter to balance generation and load. It is also preferred that a GFM inverter maintain the terminal frequency after a power system fault. In this paper, we investigate the trade-off between the primary control objective and the transient response. To quantify the transient performance of the GFM inverter, we introduce a new real-time transient stability index (TSI). This index plays a crucial role in our investigation, as it allows us to compare the performance trade-offs of different sets of GFM control parameters.

Lin, Xuheng↗

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan↗