Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Phasor Based Control with the Distributed, Extensible Grid Control Platform

This paper describes how to implement Phasor Based Control (PBC) using the Distributed, Extensible Grid Control (DEGC) Platform. PBC is a novel method for controlling distributed energy resources (DER) that coordinates a centralized optimization with distributed feedback controllers to enforce voltage phasor targets. DEGC is an open source software and communication platform designed for general DER control. We deployed PBC at Lawrence Berkeley Lab's FLEXLAB test site, conducting multiple hardware-in-the-loop test runs. Here, we describe how DEGC was used to implement PBC on hardware, and results demonstrating successful deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Miniature DC electromagnetic pumps of molten lead and sodium to support development of Gen-IV nuclear reactors

This work developed designs of submerged, dual-regions, miniature DC-EM pumps for circulating molten lead and liquid sodium at ≤500 °C without active cooling for use in ex-pile and in-pile test loops to support of materials and fuel developments for Gen-IV sodium and molten lead fast nuclear reactor. These pumps with two pumping regions are 57 mm, 66.8 mm, 95.4 mm, and 133.5 mm in diameter and have two Alnico 5 permanent magnets with Hiperco-50 pole pieces for focusing the magnetic field lines in the flow duct. The Equivalent Circuit Model (ECM) linked to the Finite Element Method Magnetics (FEMM) software in MATLAB platform calculated the pumps characteristics for a wide range of parameters. Also determined are the pumps dimensions for the highest cumulative pumping power and peak efficiency. These dimensions are the height, width, and length of the flow duct, the thickness of the Alnico magnets, the length of current electrodes, and the separation distance between the two pumping regions. For molten lead, the pumping power increases from 368 W to 728 W, and the peak efficiency from 14.7% to 31.6% with increased pump diameter from 57 mm to 133.5 mm. In conclusion, for liquid sodium, both the pumping power and peak efficiency are higher, increasing from 392 W to 767 W and from 44.3 to 51.2%, respectively, with increased pump diameter from 57 mm to 133.5 mm.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Compact Heat Exchanger Design and Testing for Advanced Reactors and Advanced Power Cycles

The goal of the proposed research is to demonstrate the thermal hydraulic performance of innovative surface geometries in compact heat exchangers used as intermediate heat exchangers (IHXs) and recuperators for the supercritical carbon dioxide (s-CO 2 ) Brayton cycle. Printed-circuit heat exchangers (PCHEs) are the primary compact heat exchangers of interest. The overall objectives are: To develop optimized PCHE designs for different working fluid combinations including helium to s-CO 2 , liquid salt to s-CO 2 , sodium to s-CO 2 , and liquid salt to helium; To experimentally and numerically investigate thermal performance, thermal stress and failure mechanism of PCHEs under various transients; and To study diffusion bonding techniques for elevated-temperature alloys and examine post-test material integrity of the PCHEs. The project objectives were accomplished by defining and executing five different tasks corresponding to these specific objectives. The first task involved a thorough literature review and a selection of IHX candidates with different surface geometries as well as a summary of prototypic operational conditions. The second task involved optimization of PCHE design with numerical analyses of thermal-hydraulic performances and mechanical integrity. The subsequent task dealt with the development of testing facilities and engineering design of PCHE to be tested in s-CO 2 fluid conditions. The next task involved experimental investigation and validation of the thermal-hydraulic performances and thermal stress distribution of prototype PCHEs manufactured with particular surface geometries. The last task involved an investigation of diffusion bonding process and posttest destructive testing to validate mechanical design methods adopted in the design process. The experimental work utilized the two test facilities at The Ohio State University (OSU) including one existing High-Temperature Helium Test Facility (HTHF) and the newly developed s-CO 2 test loop (STL) facility and s-CO 2 test facility at University of Wisconsin – Madison (UW).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Considerations for testing full-scale wind turbine nacelles with hardware-in-the-loop

In this paper, pole placement control techniques are utilized to compensate for variations in the torsional dynamics resulting from the different boundary conditions experienced by a wind turbine nacelle when mounted on a test bench. Simulation case studies are used to understand the baseline torsional characteristics of the nacelle coupled to the test bench versus that coupled to the rotor. It was found that the frequency shifts by up to 200% and 400% for the first and second torsional modes, respectively. The feasibility of utilizing pole placement technique to match the torsional characteristics of the turbine on the test bench is investigated using PI and PID controllers. Here, the performance of the tuned controller is then verified under two test scenarios: Low Voltage Ride Through (LVRT), and a highly dynamic turbulent wind input. It is demonstrated that tuning the test bench speed controller can effectively shift the poles of the closed-loop system to match the desired first and second modes of the full turbine and replicate transient field events on the test bench.

17 WIND ENERGY↗

Boiling Closure Model Validation/Development Effort with TAMU Experimental Data

This report describes a model validation and developmental effort in INL based on the analysis of experimental data taken from TAMU subcooled flow boiling facility. This report first describes briefly the test loop, experimental strategy, measurement techniques, data quality achieved, and test boundary conditions. Then, two main topics are discussed based on the experimental observation, bubble departure frequency and sliding bubble characteristics. The comparison of experimental data with the prediction of bubble departure frequency models shows that the predictive capability of existing models depends strongly on flow conditions. Also, the best performance region of each bubble departure frequency model could be determined from this analysis. Another critical achievement through this study is that the limitation of existing CFD boiling models dealing with sliding bubble effect was clearly identified. Specifically, the experimental observation indicates that the wall area influenced by sliding bubbles is not just a function of bubble size, but also depends strongly on sliding bubble trajectory and sliding distance. As a result, the bubble influence factor ( K ) for the small size of sliding bubbles was often found substantially higher than those reported in literature. In this regard, an effort is currently being made in INL to develop a new model to predict the sliding bubble effect on wall heat transfer based on the insight achieved from TAMU subcooled flow boiling experiment.

42 ENGINEERING↗

Heated Bundle Test in AREVA Inc's Fuel Cooling Test Facility

As part the Department of Energy (DOE) initiative for advanced nuclear fuel development, AREVA Inc is performing a series of flow and thermal mixing tests on a simulated, internally heated bundle of wire-wrapped fuel pins of the type commonly used in liquid-metal fast-breeder reactors at its Fuel Cooling Test Facility (FCTF) in Richland, Washington. The FCTF is part of the Product Development Test Facility (PDTF), which is a dedicated facility for advanced thermal-hydraulic testing of nuclear fuel assemblies. Initially developed to perform post Loss Of Coolant Accident (LOCA) testing, i.e., spray and reflood tests, this test facility has been adapted to accommodate the unique requirements of the heated bundle tests described here. The purpose of this test is to investigate and measure thermal distribution and pressure drop behavior for two configurations (non-deformed and deformed duct) of heated 61-pin, hexagonally packed fast reactor test assembly in a fully turbulent regime for generating Computational Fluid Dynamics (CFD) validation grade data. This test is performed in conjunction with high fidelity flow field measurement experiments and high fidelity CFD to provide a comprehensive understanding of the flow inside such a design. The present paper focuses on the heated bundle test performed at AREVA Inc. First, the test loop is described and then an overview of the test activities is presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of LWR Fuels with Enhanced Accident Tolerance

Significant progress was made on the technical, licensing, and business aspects of the Westinghouse Electric Company’s Enhanced Accident Tolerant Fuel (ATF) by the Westinghouse ATF team. The fuel pellet options included waterproofed U 15 N and U 3 Si 2 and the cladding options SiC composites and zirconium alloys with surface treatments. Technology was developed that resulted in U 3 Si 2 pellets with densities of >94% being achieved at the Idaho National Laboratory (INL). The use of U 3 Si 2 will represent a 15% increase in U235 loadings over those in UO₂ fuel pellets. This technology was then applied to manufacture pellets for 6 test rodlets which were inserted in the Advanced Test Reactor (ATR) in early 2015 in zirconium alloy cladding. The first of these rodlets are expected to be removed in about 2017. Key characteristics to be determined include verification of the centerline temperature calculations, thermal conductivity, fission gas release, swelling and degree of amorphization. Waterproofed UN pellets have achieved >94% density for a 32% U 3 Si 2 /68% UN composite pellet at Texas A&M University. This represents a U235 increase of about 31% over current UO 2 pellets. Pellets and powders of UO 2 , UN, and U 3 Si 2 the were tested by Westinghouse and Los Alamos National Laboratory (LANL) using differential scanning calorimetry to determine what their steam and 20% oxygen corrosion temperatures were as compared to UO 2 . Cold spray application of either the amorphous steel or the Ti 2 AlC was successful in forming an adherent ~20 micron coating that remained after testing at 420°C in a steam autoclave. Tests at 1200°C in 100% steam on coatings for Zr alloy have not been successful, possibly due to the low density of the coatings which allowed steam transport to the base zirconium metal. Significant modeling and testing has been carried out for the SiC/SiC composite/SiC monolith structures. A structure with the monolith on the outside and composite on the inside was developed which is the current baseline structure and a SiC to SiC tube closure approach. Permeability tests and mechanical tests were developed to verify the operation of the SiC cladding. Steam autoclave (420°C), high temperature (1200°C) flowing steam tests and quench tests were carried out with minimal corrosion, mechanical or hermeticity degradation effect on the SiC cladding or end plug closure. However, in-reactor loop tests carried out in the MIT reactor indicated an unacceptable degree of corrosion, likely due to the corrosive effect of radiolysis products which attacked the SiC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hawaiian Electric Advanced Inverter Grid Support Function Laboratory Validation and Analysis

The objective for this test plan was to better understand how to utilize the performance capabilities of advanced inverter functions to allow the interconnection of distributed energy resource (DER) systems to support the new Customer Self-Supply, Customer Grid-Supply, and other future DER programs. The purpose of this project was: 1) to characterize how the tested grid supportive inverters performed the functions of interest, 2) to evaluate the grid supportive inverters in an environment that emulates the dynamics of O'ahu's electrical distribution system, and 3) to gain insight into the benefits of the grid support functions on selected O'ahu island distribution feeders. These goals were achieved through laboratory testing of photovoltaic inverters, including power hardware-in-the-loop testing.

14 SOLAR ENERGY↗

Evaluation of precipitates used in strainer head loss testing : Part I. chemically generated precipitates.

The purpose of the current program was to evaluate the properties of chemical precipitates proposed by industry that have been used in sump strainer head loss testing. Specific precipitates that were evaluated included aluminum oxyhydroxide (AlOOH) and sodium aluminum silicate (SAS) prepared according to the procedures in WCAP-16530-NP, along with precipitates formed from injecting chemicals into the test loop according to the procedure used by one sump strainer test vendor for U.S. pressurized water reactors. The settling rates of the surrogate precipitates are strongly dependent on their particle size and are reasonably consistent with those expected from Stokes Law or colloid aggregation models. Head loss tests showed that AlOOH and SAS surrogates are quite effective in increasing the head loss across a perforated pump inlet strainer that has an accumulated fibrous debris bed. The characteristics of aluminum hydroxide precipitate using sodium aluminate were dependent on whether it was formed in high-purity or ordinary tap water and whether excess silicate was present or not.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal evaluation of uranium silicide miniplates irradiated at high heat flux

The Gas Test Loop (GTL)-1 irradiation experiment was conducted in the Advanced Test Reactor (ATR) to assess corrosion performance of proposed booster fuel at heat flux levels ~30% above the design operating condition. Sixteen miniplates fabricated from 25% enriched, high-density (4.8 g U/cm3) U3Si2/Al dispersion fuel with 6061 aluminum cladding were subjected to peak beginning of cycle (BOC) heat fluxes ranging from 411 to 593 W/cm2. No adverse impacts to the miniplates were observed at these high heat flux levels. A detailed finite element model was constructed to calculate temperatures and heat flux for an as-run cycle average effective ATR south lobe power of 25.4 MW(t). Miniplate heat flux levels and fuel, cladding, hydroxide, and coolant–hydroxide interface temperatures were calculated using the average hydroxide thickness on each miniplate measured during post-irradiation examination. The purpose of this study was to obtain a best estimate of the as-run experiment temperatures to aid in establishing acceptable heat flux levels and designing fuel qualification experiments for this fuel type.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-GWP HVAC System with Ultra-small Centrifugal Compression

Mechanical Solutions, Incorporated (MSI) was awarded a contract from the United States Department of Energy under Contract DE-EE0007042 to advance the potential of vapor compression utilizing an advanced high speed centrifugal compressor with an advanced heat exchanger design. The design was mandated to maintain high efficiency while utilizing a low GWP refrigerant. The specific goal of this program was to develop an advanced 5 ton air conditioning system. The target of the air conditioner is residential and commercial. To accomplish these goals, MSI teamed with Lennox International, a leading air conditioning manufacturer. MSI would design, oversee manufacturing, assemble, and test the compressor, while Lennox designed the heat exchanger and tested the overall air conditioner. Lennox initiated the project with a detailed cycle analysis that examined systems and refrigerants. At various break points, MSI performed a preliminary compressor design to identify realizable targets. Initially, the refrigerant that was targeted was R1234ze(E), but this was subsequently rejected over concerns of flammability. R515a was ultimately accepted as a qualified fluid based upon its GWP and flammability rating. MSI performed a complete design of the centrifugal compressor based upon the cycle system design and analysis. The design was based upon advanced aerodynamics utilizing transient Computational Fluid Dynamics (CFD), as well as mechanical and rotordynamic analysis. A detailed materials investigation was conducted to ensure mechanical integrity and refrigerant compatibility. To achieve the high rotational speed required by the compressor (105,300 rpm), foil bearings were designed by MSI, as was a high speed motor to provide the required torque for the compressor. All elements of the design complied with Design for Manufacturing and Assembly (DFMA) principles. The compressor was manufactured in components, utilizing specializing subcontractors throughout the country. The components were assembled into an operational compressor in MSI’s Albany facility, where it was tested in the MSI refrigeration test loop. The compressor achieved 90% of its maximum speed during testing at MSI. The interaction between the inverter and the high speed motor was the reason that full speed could not be attained. The compressor operated smoothly and quietly at all speeds, with the bearings performing as expected. The compressor was then shipped to Lennox’s facilities in Texas, where it was tested in the entire air conditioning system. Lennox was able to achieve 95% of the maximum rotational speed. They employed the same inverter as MSI. Lennox compiled the results of the testing and based upon the results, a go forward plan has been developed to correct the issues with the inverter, as well as redesign some parts that proved to be a challenge during the program. The consensus of the team is that a fully functional air conditioning system can be developed to achieve all of the goals identified in this program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Hydraulic Experimental Test Article: Status Report for FY2019

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, the secondary system in the 18-inch Test Vessel #6, and its sodium-to-air heat exchanger will occupy the location for 18-inch Test Vessel #5 (Test Vessel #5 will not be installed), Figure 2. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gear Test Assembly - Status Report For FY2019

The final stages of pre-sodium commissioning were completed for the Gear Test Assembly (GTA) in late 2018 and all the components were moved to building 308 for final preparations for insertion into the Mechanisms Engineering Test Loop (METL). The GTA was fully assembled in the experimental test assembly workstation and all supporting electrical and hardware systems were installed on the METL Mezzanine. The GTA was installed in Test Vessel 1 after performing a final systems check, and the vessel and article were raised to operating temperature and held for two weeks to bake-out any moisture present in the components. Test Vessel 1 was filled with sodium and a purification process was completed using the cold trap system. When the sodium was sufficiently clean, Test Vessel 1 was isolated from the rest of METL, and experimental operation of the GTA commenced. The experimental operations consisted of rotating two shafts using Parker servomotors to apply a prototypic torque of a fuel handling mechanism removing and inserting a sodium fast reactor fuel assembly. This removing and inserting motion was repeated until the system seized, indicating component degradation of either the gears or the bearings in the test gearbox. A total of 19,600 cycles were completed, corresponding to the removal and insertion of 9,800 fuel assemblies. The system was shut down and then prepared for removal. The Flexicask System was successfully used to remove the GTA from Test Vessel 1 while keeping both vessel and article inert during the process. The GTA was installed in the Carbonation System, where the process of slowly reacting the sodium away using moist CO 2 has been started. Once the GTA is fully cleaned, it will be disassembled and the gears will undergo the same NDE process performed before testing to quantify the wear that occurred. A report on this, along with the data analysis from the experimental operations will be submitted in late 2019.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗