Search NASA⌕ Search

SEARCH · Search NASA

Results for “low temperature detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Warming nuclear pasta with dark matter: kinetic and annihilation heating of neutron star crusts

Neutron stars serve as excellent next-generation thermal detectors of dark matter, heated by the scattering and annihilation of dark matter accelerated to relativistic speeds in their deep gravitational wells. However, the dynamics of neutron star cores are uncertain, making it difficult at present to unequivocally compute dark matter scattering in this region. On the other hand, the physics of an outer layer of the neutron star, the crust, is more robustly understood. We show that dark matter scattering solely with the low-density crust still kinetically heats neutron stars to infrared temperatures detectable by forthcoming telescopes. We find that for both spin-independent and spin-dependent scattering on nucleons, the crust-only cross section sensitivity is 10 -43 - 10 -41 cm 2 for dark matter masses of 100 MeV - 1 PeV, with the best sensitivity arising from dark matter scattering with a crust constituent called nuclear pasta (including gnocchi, spaghetti, and lasagna phases). For dark matter masses from 10 eV to 1 MeV, the sensitivity is 10 -39 - 10 -34 cm 2 , arising from exciting collective phonon modes in a neutron superfluid in the inner crust. Furthermore, for any s-wave or p-wave annihilating dark matter, we show that dark matter will efficiently annihilate by thermalizing just with the neutron star crust, regardless of whether the dark matter ever scatters with the neutron star core. This implies efficient annihilation in neutron stars for any electroweakly interacting dark matter with inelastic mass splittings of up to 200 MeV, including Higgsinos. We conclude that neutron star crusts play a key role in dark matter scattering and annihilation in neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

AGR-5/6/7 Final Release-to-Birth Ratio Data Analysis

AGR-5/6/7 is the last of a series of Advanced Gas Reactor (AGR) experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tristructural isotropic (TRISO) low-enriched fuel for use in the high-temperature gas cooled reactor (HTGR). AGR configuration and irradiation conditions are based on prismatic HTGR technology that is distinguished primarily through the use of helium coolant, a low-power-density ceramic core capable of withstanding very high temperatures, and TRISO-coated particle fuel. The AGR tests provide valuable irradiation-performance data to support fuel process development, qualify fuel for normal operation and accident conditions, and support development and validation of fuel performance and fission-product (FP) transport models and codes. Each AGR test consists of multiple independently controlled and monitored capsules containing fuel compacts placed in a graphite cylinder shrouded by a steel shell. Release-to-birth ratios (R/B) for fission-gas isotopes released from each capsule are calculated from release rates, measured by germanium detectors in the Fission Product Monitoring System (FPMS) installed downstream from each capsule, and birth rates calculated using numerical models of FG generation. The R/Bs are a critical measure of the ability of the fuel kernel, the particle coating layers, and the compact matrix to retain fission-gas atoms, preventing their release into the sweep-gas flow, and the impact of initially defective particles and/or particle-coating failures that occur during irradiation. For fission-gas isotopes, particle failure is defined as failure of all coating layers, allowing gaseous fission atoms to escape from a particle. During the first five cycles (162B ? 165A), R/Bs were stable in the 10-8?10-6 range, and no in-pile particle failures were observed, based on the gross gamma counts. The maximum R/B value of around 2 ? 10-6 for Kr-85m resulted from the presence of as-fabricated exposed kernels (based on the high exposed kernel fraction), the dispersed uranium, and high fuel particle temperatures in Capsule 1. Comparison of capsule-measured R/Bs from these early cycles to predictions using the previously developed AGR R/B model demonstrated FG release from the AGR-5/6/7 TRISO fuel was comparable to that of previous experiments. In addition, the Kr-85m R/B per-exposed-kernel values are comparable to R/B values obtained in AGR-3/4 irradiation experiment and four irradiation experiments performed during 1980s: (1) HRB-17/18, (2) COMEDIE-BD1, (3) HFR B1, and (4) HRB-21. In contrast, all measured R/B values are lower than predictions by the commonly used Richards and German models, which are intentionally conservative. A large number of in-pile particle failures occurred in Capsule 1 by the end of Cycle 166A. During the final four cycles (166A ? 168A), apparent damage to the Capsule 1 gas line appeared to cause FG leakage from that capsule into the other four capsules, resulting in an increase in fission gas (FG) detected in the effluent for all capsules. Isolation of the Capsule 1 gas line during the last three cycles also prevented measurement of its FG release. Thus, R/Bs in all capsules after Cycle 166A are highly uncertain because of undefined amount of leakage from Capsule 1, especially for long-lived isotopes. A few hundred in-pile particle failures were estimated for Capsule 1 before the end of Cycle 166A, but the total number of failures is unknown due to the lack of FG release data in the later cycles. Based primarily on evidence from the gross gamma counts during Cycle 168A, approximately 15 particles failed in Capsule 3 and four particles failed in Capsule 2. In-pile failures in Capsule 3 were anticipated because this capsule was designed to operate beyond the HTGR normal operating temperature range. In contrast, no in-pile failures were identified in the top two capsules (4 and 5) based on the absence of the typical spikes in gross gamma counts and low failure estimates using the AGR model, developed in INL/EXT-14-32970, for R/B of the short-lived isotopes (Kr-89 and Xe-137) with minimal leakage from Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diamond and SiC Detectors for Rare Event Searches

In recent years, there has been increasing interest in developing detectors which are sensitive to sub-GeV dark matter and low-energy events from coherent neutrino scattering. Due to carbon’s light atomic weight and its tendency to form crystals with high-energy, long-lived phonon modes, carbon-based crystals (including diamond and silicon carbide (SiC)) present themselves as natural target materials for scattering-based searches in this regime. Here, we present our preliminary results in adapting our TES-based detectors to these substrates, specifically 4-H SiC and polycrystalline diamond. We focus on our fabrication efforts, specifically tuning the transition temperature (T C ) of tungsten films sputtered on these materials, as well as our advancement toward fabricating and testing devices on these substrates.

47 OTHER INSTRUMENTATION↗

Demonstration of Temperature Compensation Techniques for SPNDs Operating in High Temperatures

This report presents the testing results of rhodium-based self-powered neutron detectors (Rh-SPND) irradiated in a furnace dry tube from ambient temperature to 850°C at the Ohio State University Research Reactor. The purpose of the experiment is to demonstrate the technique and application of a temperature compensation technique for the Rh-SPND. This is performed by characterizing the temperature effects observed in past experiments—a displacement current and a stabilized dark current—of the Rh-SPND as a function of temperature under the models of shifting space charges as a product of photoconductivity properties. Low-power irradiation at the OSURR was performed with stabilized temperatures of ambient, 550, 575, 600, 625, 650, 675, and 700°C were first performed to obtain the curve fit parameters that describes the temperature effects. The results provided further insight for the behavior of the SPND at high temperatures in accordance with available insulation conductivity models. Transition points from photoconductivity to ionic conductivity were identified in the range of 550–600°C. Additionally, transition points ionic to electric conductivity were observed in the range of 675–700°C, however, the data was not able to fully capture the transition and did not have enough resolution to provide predictive compensation based only on temperature readings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray imaging and electron temperature evolution in laser-driven magnetic reconnection experiments at the national ignition facility

We present results from x-ray imaging of high-aspect-ratio magnetic reconnection experiments driven at the National Ignition Facility. Two parallel, self-magnetized, elongated laser-driven plumes are produced by tiling 40 laser beams. A magnetic reconnection layer is formed by the collision of the plumes. A gated x-ray framing pinhole camera with micro-channel plate detector produces multiple images through various filters of the formation and evolution of both the plumes and current sheet. As the diagnostic integrates plasma self-emission along the line of sight, two-dimensional electron temperature maps ⟨Te⟩Y are constructed by taking the ratio of intensity of these images obtained with different filters. The plumes have a characteristic temperature ⟨Te⟩Y=240 ± 20 eV at 2 ns after the initial laser irradiation and exhibit a slow cooling up to 4 ns. The reconnection layer forms at 3 ns with a temperature ⟨Te⟩Y=280 ± 50 eV as the result of the collision of the plumes. The error bars of the plumes and current sheet temperatures separate at 4 ns, showing the heating of the current sheet from colder inflows. Using a semi-analytical model, we survey various heating mechanisms in the current sheet. We find that reconnection energy conversion would dominate at low density (ne≲7×1018 cm−3) and electron-ion collisional drag at high-density (≳1019 cm−3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Charge Trap Analysis in a SENSEI Skipper-CCD: Understanding Low-Energy Backgrounds in Rare-Event Searches

Skipper Charge-Coupled Devices (Skipper-CCDs) are ultra-low-threshold detectors capable of detecting energy deposits in silicon at the eV scale. Increasingly used in rare-event searches, one of the major challenges in these experiments is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon Skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we employ the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly but more work is needed to assess the impact of the traps that can not be characterized.

Brusco, Agustin [Buenos Aires U.]↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a J -coupled spectrometer for multidimensional structure and relaxation detection at low magnetic fields

In recent years, it has been realized that low and ultra-low field (mT-nT magnetic field range) nuclear magnetic resonance (NMR) spectroscopy can be used for molecular structural analysis. However, spectra are often hindered by lengthy acquisition times or require large sample volumes and high concentrations. Here, we report a low field (50 µT) instrument that employs a linear actuator to shuttle samples between a 1 T prepolarization field and a solenoid detector in a laboratory setting. The current experimental setup is benchmarked using water and 13 C-methanol with a single scan detection limit of 2x10 20 spins (3 μL, 55 M H 2 O) and detection of 2.9x10 19 (200 μL, 617 mM 13 C-methanol) spins with signal averaging. The system has a dynamic range of >3 orders of magnitude. Investigations of room-temperature relaxation dynamics of 13Cmethanol show that sample dilution can be used in lieu of sample heating to acquire spectra with linewidths comparable to high-temperature spectra. These results indicate that the T 1 and T 2 mechanisms are governed by both the proton exchange rate and the dissolved oxygen in the sample. Finally, a 2D correlation spectroscopy (COSY) experiment is reported, performed in the strong coupling regime that resolves the multiple resonances associated with the heteronuclear Jcoupling. The spectrum was collected using 10 times less sample and in less than half the time from previous reports in the strong coupling limit.

47 OTHER INSTRUMENTATION↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Tuning microwave losses in superconducting resonators

Abstract The performance of superconducting resonators, particularly cavities for particle accelerators and micro cavities and thin film resonators for quantum computations and photon detectors, has been improved substantially by recent material treatments and technological advances. As a result, the niobium cavities have reached the quality factors Q ∼ 10 11 at 1–2 GHz and 1.5 K and the breakdown radio-frequency (rf) fields H close to the dc superheating field of the Meissner state. These advances raise the questions of whether the state-of-the-art cavities are close to the fundamental limits, what these limits actually are, and to what extent the Q and H limits can be pushed by the materials nano structuring and impurity management. These issues are also relevant for many applications using high-Q thin film resonators, including single-photon detectors and quantum circuits. This topical review outlines basic physical mechanisms of the rf nonlinear surface impedance controlled by quasiparticles, dielectric losses and trapped vortices, as well as the dynamic field limit of the Meissner state. Sections cover methods of engineering an optimum quasiparticle density of states and superfluid density to reduce rf losses and kinetic inductance by pairbreaking mechanisms related to magnetic impurities, rf currents, and proximity-coupled metallic layers at the surface. A section focuses on mechanisms of residual surface resistance, which dominates rf losses at ultra low temperatures. Microwave losses of trapped vortices and their reduction by optimizing the concentration of impurities and pinning potential are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Measurements of Intermediate Species in Fuel-Rich Oxidation of Ethylene, Toluene, and n -Decane

Polycyclic aromatic hydrocarbons (PAHs) are important precursors to the formation of soot and are also pollutant emissions from combustion devices, including internal combustion engines. To understand the formation of PAHs, the low-molecular-weight hydrocarbon chemistry leading to their formation needs to be understood. Toward this goal, fuel-rich oxidation of three different hydrocarbons, i.e., ethylene, toluene, and n-decane, has been investigated in an atmospheric pressure flow reactor at varying temperatures (1000–1350 K), equivalence ratios (φ = 3.0–12.0), and residence times of 0.25–1.5 s. The major C 1 to C 7 intermediates, such as methane, acetylene, ethylene, allene, propyne, propylene, vinylacetylene, 1,3-butadiene, cyclopentadiene, benzene, and toluene, were quantified using a gas chromatograph equipped with a flame ionization detector. The experimental tendency of intermediate species formation, e.g., the dependence of temperature, equivalence ratio, and residence time, was similar in ethylene oxidation and n-decane oxidation. The concentrations of intermediate species up to C 4 were higher in ethylene/n-decane oxidation than toluene oxidation, while a nearly equal or larger amount of C5–C7 species was produced in toluene oxidation. The experimental data were compared with modeling results using a detailed chemical kinetic mechanism. The calculated data using the kinetic model were in agreement with the experimental results. Additionally, a comprehensive kinetic analysis on the reaction pathways of each species was conducted to assess the differences in the oxidation chemistry with the change in the structure of hydrocarbons. In particular, in-depth analysis of benzene formation was performed, elucidating that two benzene formation pathways were important in ethylene and n-decane oxidation: (1) H elimination of the 2,4-cyclohexadienyl radical produced from the isomerization of the 2,4-cyclopentadienylmethyl radical, and (2) dehydrogenation of cyclohexadiene produced from reactions of vinyl radical with 1,3-butadiene. In toluene oxidation, it was found that benzene was primarily produced from toluene through the replacement of the methyl group with hydrogen.

30 DIRECT ENERGY CONVERSION↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗