Search NASA⌕ Search

SEARCH · Search NASA

Results for “low temperature processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Development of fine diameter mullite fiber

Results are presented of a program to develop and evaluate mullite fiber with a mean diameter under two microns. The two micron fiber is produced by a blowing process at room temperature from a low viscosity (10-25 poise) solution. The blown fiber was evaluated for dimensional stability in thermal cycling to 1371 C, and was equivalent to the 5 micron spun B and W mullite fiber. An additive study was conducted to evaluate substitutes for the boron. Three levels of chromium, lithium fluoride, and magnesium were added to the standard composition in place of boron and the fiber produced was evaluated for chemical and dimensional stability in thermal cycling to 1371 C. The magnesium was the most chemically stable, but the chrome additive imparted the best dimensional stability.

Long, W. G.↗

Thermodynamic analysis of alternate energy carriers, hydrogen and chemical heat pipes

The paper discusses the production concept and efficiency of two new energy transmission and storage media intended to overcome the disadvantages of electricity as an overall energy carrier. These media are hydrogen produced by water-splitting and the chemical heat pipe. Hydrogen can be transported or stored, and burned as energy is needed, forming only water and thus obviating pollution problems. The chemical heat pipe envisions a system in which heat is stored as the heat of reaction in chemical species. The thermodynamic analysis of these two methods is discussed in terms of first-law and second-law efficiency. It is concluded that chemical heat pipes offer large advantages over thermochemical hydrogen generation schemes on a first-law efficiency basis except for the degradation of thermal energy in temperature thus providing a source of low-temperature (800 K) heat for process heat applications. On a second-law efficiency basis, hydrogen schemes are superior in that the amount of available work is greater as compared to chemical heat pipes.

Cox, K. E.↗

Ortho and parahydrogen in interstellar material

The ortho/para molecular hydrogen ratio in the interstellar medium is considered. It is shown that the ortho/para ratio will be 3:1 in practically all chemical reactions, even at relatively low temperatures. Two examples of exothermic processes that will result in the formation of a 3:1 ortho:para ratio, corresponding to a high-temperature equilibrium, are examined: H2 formation via three-body or surface recombination and catalytic recombination involving electrons and H(-) ions. Gas-phase scrambling ion reactions are also discussed, and it is suggested that virtually all the H2 equilibrated via scrambling reactions involving H(+) and H3(+) ions should exist as parahydrogen in the J ? 0 quantum state. Arguments are given that deuterium cannot interfere with the long scrambling chain that results in parahydrogen formation.

Reeves, R. R.↗

The TIROS-N high resolution infrared radiation sounder

The high-resolution infrared radiation sounder (HIRS/2) was developed and flown on the Television and Infrared Observation Satellite, N Series (TIROS-N) as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow spectral channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel, and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic performance of the instrument in test is described. Early orbital information from the TIROS-N launched on October 13, 1978 are given and some observations on system quality are made.

Koenig, E. W.↗

Solar thermal materials research and development

Objectives of the Materials Research and Development effort are examined. The behavior and interaction of different materials used in solar thermal technologies are studied so as to create a sound technical base for future system and component designs. Materials are developed to extend the application potential of systems by either making materials more reliable in difficult operating environments or by offering lower cost alternatives to presently used materials. Solar thermal systems designed for electric power, industrial process heat from low to high temperature, and fuels and chemicals applications are discussed.

Gupta, B. P.↗

Performance of the HIRS/2 instrument on TIROS-N

The High Resolution Infrared Radiation Sounder (HIRS/2) was developed and flown on the TIROS-N satellite as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow radiation channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7 K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic features, operating characteristics and performance of the instrument in test are described. Early orbital information from the TIROS-N launched on October 13, 1978 is given and some observations on system quality are made.

Koenig, E. W.↗

ISEE 3 observations of solar wind thermal electrons with T-perpendicular greater than T-parallel

This study presents ISEE 3 observations of anomalous electron distributions for which T-perpendicular exceeds T-parallel in the solar wind near 1 AU. Twelve anomaly events were identified, lasting from 24 min to 6 hours. These events generally share the following characteristics: (1) high plasma density, (2) low solar wind speed, (3) magnetic field which is nearly transverse to the flow, and (4) low electron and ion temperatures. The processes of solar wind adiabatic expansion and isotropization via Coulomb collisions could be expected to lead to such anomalous anisotropies under conditions similar to those observed. However, these conditions actually produce T-perpendicular greater than T-parallel for only a small fraction of the time, suggesting that other mechanisms are also important in regulating solar wind electron distributions.

Phillips, J. L.↗

A conceptual approach for noncontact calorimetry in space

A concept is developed and described which allows to measure the heat capacity and the effective thermal conductivity of stable and undercooled liquid metals and alloys in an electromagnetic levitation apparatus. A proposal is made to use an ac pulse heating method which is used nowadays as a standard technique for precision measurement of low-temperature heat capacities. The ideal process parameters, including the drop diameter D, temperature T, and frequency of measurement omega, can be optimized when the following relations hold for the external and internal relaxation time constants tau-1 and tau-2, respectively: omega(tau-1) greater than 10 and omega(tau-2) less than 0.1. Then, heat capacity data can be obtained with an accuracy of better than 1 percent with D about 5 to 10 mm, T between 1200 and 1800 K, and omega between 0.1 and 1 Hz for typical metals and alloys.

Fecht, H. J.↗

Biogenic Magnetite in Martian Meteorite ALH84001

Fine-grained magnetite (Fe3O4) in martian meteorite ALH84001, generally less than 200 microns in size, is located primarily in the rims that surround the carbonate globules. There are two populations of ALH84001 magnets, which are likely formed at low temperature by inorganic and biogenic processes. Nearly 27/o of ALH84001 magnetite particles. also called elongated prisms, have characteristics which make them uniquely identifiable as biological precipitates.

Thomas-Keprta, Kathie L.↗

Biogenic Magnetite in Martian Meteorite ALH84001

Fine-grained magnetite (Fe3O4) in martian meteorite ALH84001, generally less than 200 nm in size, is located primarily in the rims that surround the carbonate globules. There are two populations of ALH84001 magnetites, which are likely formed at low temperature by inorganic and biogenic processes. Nearly 27% of ALH84001 magnetite particles, also called elongated prisms, have characteristics which make them uniquely identifiable as biological precipitates. Additional information is contained in the original extended abstract.

Thomas-Keprta, K. L.↗

Large Format Si:As IBC Array Performance for NGST and Future IR Space Telescope Applications

A mid-IR (5-30micrometer) instrument aboard a cryogenic space telescope can have an enormous impact in resolving key questions in astronomy and cosmology. A space platform's greatly reduced thermal backgrounds (compared to airborne or ground-based platforms), allow for more sensitive observations of dusty young galaxies at high redshifts, star formation of solar-type stars in the local universe, and formation and evolution of planetary disks and systems. The previous generation's largest, in sensitive IR detectors at these wavelengths are 256x256 pixel Si:As Impurity Band Conduction (IBC) devices built by Raytheon Infrared Operations (RIO) for the Space Infrared Telescope Facility/Infrared Array Camera (SIRTF)/(IRAC) instrument. RIO has successfully enhanced these devices, increasing the pixel count by a factor of 16 while matching or exceeding SIRTF/IRAC device performance. NASA-ARC in collaboration with RIO has tested the first high performance large format (1024x 1024) Si:As IBC arrays for low background applications, such as for the middle instrument on Next Generation Space Telescope (NGST) and future IR Explorer missions. These hybrid devices consist of radiation hard SIRTF/IRAC-type Si:As IBC material mated to a readout multiplexer that has been specially processed for operation at low cryogenic temperatures (below 10K), yielding high device sensitivity over a wavelength range of 5-28 micrometers. We present laboratory testing results from these benchmark, devices. Continued development in this technology is essential for conducting large-area surveys of the local and early universe through observation and for complementing future missions such as NGST, Terrestrial Planet Finder (TPF), and Focal Plane Instruments and Requirement Science Team (FIRST).

Ennico, Kimberly↗

Artificial Hair Cells for Sensing Flows

The purpose of this article is to present additional information about the flow-velocity sensors described briefly in the immediately preceding article. As noted therein, these sensors can be characterized as artificial hair cells that implement an approximation of the sensory principle of flow-sensing cilia of fish: A cilium is bent by an amount proportional to the flow to which it is exposed. A nerve cell at the base of the cilium senses the flow by sensing the bending of the cilium. In an artificial hair cell, the artificial cilium is a microscopic cantilever beam, and the bending of an artificial cilium is measured by means of a strain gauge at its base (see Figure 1). Figure 2 presents cross sections of a representative sensor of this type at two different stages of its fabrication process. The process consists of relatively- low-temperature metallization, polymer-deposition, microfabrication, and surface-micromachining subprocesses, including plastic-deformation magnetic assembly (PDMA), which is described below. These subprocesses are suitable for a variety of substrate materials, including silicon, some glasses, and some polymers. Moreover, because it incorporates a polymeric supporting structure, this sensor is more robust, relative to its silicon-based counterparts.

Chen, Jack↗

Laminar Non-Premixed Flames of Gaseous Fuel Aboard the International Space Station

From late 2017 to early 2022, six independent studies with flames of gaseous fuels were conducted on the International Space Station (ISS) in the U.S. combustion research facility. An exploration of flames at the extremes of high sooting and high dilution was conducted with a coaxial coflow burner, where the fuel and oxidizer velocities were typically matched. An investigation of electric-field effects also used the same coflow burner as well as a simple gas-jet burner, with a circular electrode mesh, downstream of the burner, at voltages of either polarity up to 10 kV. A study focused on material flammability in a quiescent atmosphere emulated the burning of condensed-phased fuels using cylindrical burners with a flat perforated outlet instrumented to measure the heat flux to the burner, i.e., emulated fuel. Three studies of soot processes, flame dynamics, and low-temperature combustion used porous spherical burners, yielding a nominally one-dimensional flame structure. The objectives and selected findings of each investigation will be briefly discussed after a short review of the advantages of studying combustion in microgravity, earlier ISS research, and the experimental hardware and its operation.

flames↗

Laminar Non-Premixed Flames of Gaseous Fuel Aboard the International Space Station

From late 2017 to early 2022, six independent studies with flames of gaseous fuels were conducted on the International Space Station (ISS) in the U.S. combustion research facility. An exploration of flames at the extremes of high sooting and high dilution was conducted with a coaxial coflow burner, where the fuel and oxidizer velocities were typically matched. An investigation of electric-field effects also used the same coflow burner as well as a simple gas-jet burner, with a circular electrode mesh, downstream of the burner, at voltages of either polarity up to 10 kV. A study focused on material flammability in a quiescent atmosphere emulated the burning of condensed-phased fuels using cylindrical burners with a flat perforated outlet instrumented to measure the heat flux to the burner, i.e., emulated fuel. Three studies of soot processes, flame dynamics, and low-temperature combustion used porous spherical burners, yielding a nominally one-dimensional flame structure. The objectives and selected findings of each investigation will be briefly discussed after a short review of the advantages of studying combustion in microgravity, earlier ISS research, and the experimental hardware and its operation.

flames↗

ACME: Advanced Combustion via Microgravity Experiments

From Nov. 2017 to Feb. 2022, the ACME project’s six independent investigations of laminar, non-premixed flames of gaseous fuels were conducted on the International Space Station (ISS) in the Combustion Integrated Rack (CIR). An exploration of flames at the extremes of high sooting and high dilution was conducted with a coaxial coflow burner, where the fuel and oxidizer velocities were typically matched. An investigation of electric-field effects also used the same coflow burner as well as a simple gas-jet burner, with a circular electrode mesh downstream of the burner, at voltages of either polarity up to 10 kV. A study focused on material flammability in a quiescent atmosphere emulated the burning of condensed-phased fuels using cylindrical burners with a flat perforated outlet instrumented to measure the heat flux to the burner, i.e., emulated fuel. Three studies of soot processes, flame dynamics, and low-temperature combustion used porous spherical burners yielding a nominally one-dimensional flame structure. The ACME research will be represented through images and text.

flames↗

Nanophase Carbonates on Mars: Implications for Carbonate Formation and Habitability

Despite having an atmosphere composed primarily of CO2 and evidence for abundant water in the past, carbonate minerals have only been discovered in small amounts in martian dust [1], in outcrops of very limited extent [2, 3], in soils in the Northern Plains (the landing site of the 2007 Phoenix Mars Scout Mission) [4] and may have recently been detected in aeolian material and drilled and powdered sedimentary rock in Gale Crater (the Mars Science Laboratory [MSL] landing site) [5]. Thermal analysis of martian soils by instruments on Phoenix and MSL has demonstrated a release of CO2 at temperatures as low as 250-300 degC, much lower than the traditional decomposition temperatures of calcium or magnesium carbonates. Thermal decomposition temperature can depend on a number of factors such as instrument pressure and ramp rate, and sample particle size [6]. However, if the CO2 released at low temperatures is from carbonates, small particle size is the only effect that could have such a large impact on decomposition temperature, implying the presence of extremely fine-grained (i.e., "nanophase" or clay-sized) carbonates. We hypothesize that this lower temperature release is the signature of small particle-sized (clay-sized) carbonates formed by the weathering of primary minerals in dust or soils through interactions with atmospheric water and carbon dioxide and that this process may persist under current martian conditions. Preliminary work has shown that clay-sized carbonate grains can decompose at much lower temperatures than previously thought. The first work took carbonate, decomposed it to CaO, then flowed CO2 over these samples held at temperatures >100 degC to reform carbonates. Thermal analysis confirmed that carbonates were indeed formed and transmission electron microsopy was used to determine crystal sized were on the order of 10 nm. The next step used minerals such as diopside and wollastonite that were sealed in a glass tube with a CO2 and H2O source. After reacting these materials for a number of hours, thermal analysis demonstrated the formations of carbonates that decomposed at temperatures as low as 500 degC [7]. Further work is underway to carry out the weathering process under more Mars-like conditions (low pressure and low temperature) to determine if the carbonate decomposition temperature can be shifted to even lower temperatures, consistent with what has been detected by thermal analysis instruments on Mars.

Archer, P. Douglas, Jr.↗

Effect of substituted phenylnadimides on processing and properties of PMR polyimide composites

Three nitrophenylnadimide cure initiators and two phenylnadimides (without nitros) were evaluated as additives to PMR-15 resins and Celion 6000 graphite fiber composites. The results of a resin screening study eliminated all of the additives except 3-nitrophenylnadimide (NO2PN) for use as a low temperature curing additive for PMR-15. Thus, NO2PN and the two control additives were investigated in PMR-15 formulations from which Celion 6000 graphite fiber/PMR-15 composites were processed both with low temperature (274 C) and normal (316 C) cure cycles. Comparisons of the two processing cycles, the resultant glass transition temperatures (Tg), the ambient, 274 and 316 C composite mechanical properties determined before and after 316 C postcure, the 316 C thermo-oxidative weight losses and the retention of 316 C composite mechanical properties are presented. Empirical correlations of the type and amount of nadimide additives with processing parameters, Tg, composite mechanical properties, composite thermo-oxidative stability and long term retention of 316 C composite mechanical properties are also presented.

Alston, W. B.↗

Effect of substituted phenylnadimides on processing and properties of PMR polyimide composites

Three nitrophenylnadimide cure initiators and two phenylnadimides (without nitros) were evaluated as additives to PMR-15 resins and Celion 6000 graphite fiber composites. The results of a resin screening study eliminated all of the additives except 3-nitrophenylnadimide (NO2PN) for use as a low temperature curing additive for PMR-15. Thus, NO2PN and the two control additives were investigated in PMR-15 formulations from which Celion 6000 graphite fiber/PMR-15 composites were processed both with low temperature (274 C) and normal (316 C) cure cycles. Comparisons of the two processing cycles, the resultant glass transition temperatures (Tg), the ambient, 274 and 316 C composite mechanical properties determined before and after 316 C postcure, the 316 C thermo-oxidative weight losses and the retention of 316 C composite mechanical properties are presented. Empirical correlations of the type and amount of nadimide additives with processing parameters, Tg, composite mechanical properties, composite thermo-oxidative stability and long term retention of 316 C composite mechanical properties are also presented.

Alston, W. B.↗