Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

N-point correlations for biased galaxy formation

A general series expansion of arbitrary accuracy is given for the correlation function of the 'biased' regions of galaxy formation in terms of the mass autocorrelations. It is shown how to calculate the N-point correlations to arbitrary accuracy, and the validity of the various approximations is discussed. The asymptotic values of the N-point correlation functions at their highest point at zero spatial separation are given, and the scaling of these values is discussed.

Jensen, L. G.↗

Performance Verification and Testing of the COWVR Instrument Antenna

The Compact Ocean Wind Vector Radiometer (COWVR) is a technology demonstration mission, developed at the Jet Propulsion Laboratory (JPL), and scheduled for launch in 2016. The goal of COWVR is to provide the same windvector retrieval accuracy of other instruments, like WindSat, while reducing the total mass and using less power. In this paper, we present an overview of the COWVR instrument, and a detailed description of the EM (Electromagnetic) modeling of the antenna system and the test campaign carried out at JPL to assess its performance. Special emphasis has been placed on assessing the accuracy of the predictions made with the RF (Radio Frequency) model. We will show that the predicted radiation patterns are accurate enough so one can use them for orbit radiometer calibration.

Radiation Patterns↗

LISA and LISA Pathfinder: Gravitational Wave Observation in Space

The Laser Interferometer Space Antenna (LISA) is a planned NASA-ESA gravitational wave observatory in the frequency range of 0.1 mHz--100 mHz. This observation band is inaccessible to ground-based detectors due to fluctuations in the Earth gravitational field. Gravitational wave sources for LISA include galactic binaries, mergers of supermassive black-hole binaries, extreme-mass-ratio inspirals, and cosmology backgrounds and bursts. LISA is a constellation of three spacecraft separated by 5 million km in an equilateral triangle, whose center follows the Earth in a heliocentric orbit with an orbital phase offset of 20 degrees. Challenging technology is required to ensure pure geodetic trajectories of the six onboard test masses, whose distance fluctuations will be measured by interspacecraft laser interferometers with picometer accuracy. LISA Pathfinder is an ESA-launched technology demonstration mission of key LISA subsystems such as spacecraft control with micronewton thrusters, test mass drag-free control, and precision laser interferometry between free-flying test masses. Ground testing of hardware of the Gravitational Reference Sensor and Optical Metrology subsystems of LISA Pathfinder is currently ongoing. A detailed description of the two missions and an overview of current investigations conducted by the community will be discussed. The current status in development and implementation of LISA Pathfinder pre-flight systems and latest results of the ongoing ground testing efforts will also be presented.

Guzman, Felipe↗

Comparative Accuracies of Models for Drag Prediction During Geomagnetically Disturbed Periods: A First Principles Model Versus Empirical Models

We examine the accuracy of density prediction by the first principles model Thermosphere Ionosphere Electrodynamics General Circulation Model (TIEGCM) developed by the National Center for Atmospheric Research and compare it to the accuracy of three empirical models: Jacchia 71, the Naval Research Laboratory Mass Spectrometer Incoherent Scatter Extended 2000 (NRLMSIS), Jacchia 1971, and Jacchia-Bowman 2008. Comparisons are made for three large storms: the October 2003 storm, the March 2013 storm, and the March 2015 storm. To evaluate the accuracy of these models we use tracking data for nine space objects in low Earth orbit. Additionally, we evaluate the accuracy of the TIEGCM and NRLMSIS with data from high precision accelerometers on the Challenging Minisatellite Payload (CHAMP) and Gravity field and Circulation Explorer (GOCE) satellites. The goal is to assess the use of a first principles model as a potential tool for forecasting satellite drag during large magnetic storms. For the storms considered, we found the TIEGCM, JB2008, and NRLMSIS models to be substantially more accurate than the Jacchia 71 model. The accuracies of the TIEGCM and JB2008 models were similar, but overall, the TIEGCM was more accurate. We found smaller differences for TIEGCM versus CHAMP than for NRLMIS for the Halloween Storm, and smaller differences than results published for JB2008 and the assimilative model HASDM. The empirical models are at present more practical for operational purposes, but the TIEGCM, developed as a research model, with a greater focus on operational use offers the potential for improved utility during stressing conditions.

R. L. Walterscheid↗

Laser Interferometry for Gravitational Wave Observation: LISA and LISA Pathfinder

The Laser Interferometer Space Antenna (LISA) is a planned NASA-ESA gravitational wave observatory in the frequency range of 0.1mHz-100mHz. This observation band is inaccessible to ground-based detectors due to the large ground motions of the Earth. Gravitational wave sources for LISA include galactic binaries, mergers of supermasive black-hole binaries, extreme-mass-ratio inspirals, and possibly from as yet unimagined sources. LISA is a constellation of three spacecraft separated by 5 million km in an equilateral triangle, whose center follows the Earth in a heliocentric orbit with an orbital phase offset oF 20 degrees. Challenging technology is required to ensure pure geodetic trajectories of the six onboard test masses, whose distance fluctuations will be measured by interspacecraft laser interferometers with picometer accuracy. LISA Pathfinder is an ESA-launched technology demonstration mission of key LISA subsystems such us spacecraft control with micro-newton thrusters, test mass drag-free control, and precision laser interferometry between free-flying test masses. Ground testing of flight hardware of the Gravitational Reference Sensor and Optical Metrology subsystems of LISA Pathfinder is currently ongoing. An introduction to laser interferometric gravitational wave detection, ground-based observatories, and a detailed description of the two missions together with an overview of current investigations conducted by the community will bc discussed. The current status in development and implementation of LISA Pathfinder pre-flight systems and latest results of the ongoing ground testing efforts will also be presented

Guzman, Felipe↗

Determining the Products of Inertia for Small Scale UAVs

Moments of inertia and products of inertia often need to be determined for aircraft. As complex bodies, their mass properties need to be determined experimentally for best accuracy. While several moment of inertia experimental techniques have been developed, there are few to determine the products of inertia. Products of inertia can be easily determined mathematically if the angle between the aircraft x body axis and principal x axis is known. This method finds the principal inclination angle by mathematically correlating the measured moments of inertia about a range of axes of the aircraft. This correlation uses a least squares error minimization of a mathematical model that describes the ellipse of inertia in the aircraft's x-z axes plane. Results from a test conducted on a small scale UAV (Unmanned Aerial Vehicle) at NASA Armstrong Flight Research Center is also presented, which is an example of the intended application of this technique.

mass properties↗

Three Dimensional Cross-Sectional Properties From Bone Densitometry

Bone densitometry has previously been used to obtain cross-sectional properties of bone in a single scan plane. Using three non-coplanar scans, we have extended the method to obtain the principal area Moments of inertia and orientations of the principal axes at each cross-section along the length of the scan. Various 5 aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of mass distribution. Factors considered included X-ray photon energy, initial scan orientation, the included angle of the 3 scans, and Imin/Imax ratios. Principal moments of inertia were accurate to within 3.1% and principal angles were within 1 deg. of the expected value for phantoms scanned with included angles of 60 deg. and 90 deg. at the higher X-ray photon energy. Low standard deviations in error also 10 indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 deg. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (Imin/Imax) values when various included angles are used make this technique viable for future in vivo studies.

Cleek, Tammy M.↗

Evaluation of ERBE scanner pointing accuracy based upon a coastline detection algorithm

Measurements from the Earth Radiation Budget Experiment (ERBE) scanning radiometers must be accurately located at the top of the Earth's atmosphere for proper interpretation of derived longwave and shortwave components of the Earth radiation field. The accuracy of the location calculations is affected by the orbit characteristics and attitude control systems of the three spacecraft, ERBS, NOAA-9, and NOAA-10. A technique was developed which makes use of the longwave scanner measurements to detect the thermal gradients at the boundaries of ocean and land masses. By analyzing many such coastline boundaries, estimates of the overall accuracy of the scanner measurement location calculations have been derived for the three satellites. The resulting measurement location errors are found to be smaller than the resolution of the radiometers, and this accuracy is well within the required location knowledge for useful science analysis of the ERBE scanner data.

Weaver, William L.↗

Improvement of modal scaling factors using mass additive technique

A general investigation into the improvement of modal scaling factors of an experimental modal model using additive technique is discussed. Data base required by the proposed method consists of an experimental modal model (a set of complex eigenvalues and eigenvectors) of the original structure and a corresponding set of complex eigenvalues of the mass-added structure. Three analytical methods,i.e., first order and second order perturbation methods, and local eigenvalue modification technique, are proposed to predict the improved modal scaling factors. Difficulties encountered in scaling closely spaced modes are discussed. Methods to compute the necessary rotational modal vectors at the mass additive points are also proposed to increase the accuracy of the analytical prediction.

Zhang, Qiang↗

What determines the stellar mass functions in globular clusters?

We analyze the dependence of stellar mass function slopes for a sample of 17 globular clusters on a variety of cluster parameters. The principal novelty of our approach is the use of appropriate multivariate statistical methods to disentangle the complex situation which is present in this problem: the slopes depend simultaneously on more than one variable, and many cluster parameters are mutually correlated. We find that the mass function slopes in the range M/M(solar) = 0.5-0.8 are largely determined by the position in the Galaxy and to a lesser extent by the cluster metallicity. Clusters closer to the Galactic center or plane have shallower mass function slopes. At a given distance to the Galactic center, clusters closer to the Galactic plane have shallower mass function slopes. At a given R(GC) and/or Z(GP), more metal-rich clusters have shallower mass function slopes. Thus, the monovariate correlations with the position or metallicity are both correct, but only partial, and in terms of slopes, biased descriptions of the situation. We present trivariate least-squares solutions where the mass function slopes can be predicted within the measurement accuracy. This relation can serve as a powerful observational constraint for theories of globular cluster formation and evolution, and it is one of the tightest correlations between globular cluster properties now known.

Djorgovski, S.↗

External Interference Effects of Flow Through Static-Pressure Orifices of an Airspeed Head at Several Supersonic Mach Numbers and Angles of Attack

Wind-tunnel tests have been made to determine the static-pressure error resulting from external interference effects of flow through the static-pressure orifices of an NACA airspeed head at Mach numbers of 2.4, 3.0, and 4.0 for angles of attack of 0 deg, 5 deg, 10 deg, and 15 deg. Within the accuracy of the measurements and for the range of mass flow covered, the static-pressure error increased linearly with increasing mass-flow rate for both the forward and rear sets of orifices at all Mach numbers and angles of attack of the investigation. For a given value of flow coefficient, the static-pressure error varied appreciably with Mach number but only slightly with angle of attack. For example, for a flow coefficient out of the orifices of 0.01 (the approximate value for a vertically climbing airplane for which the airspeed system incorporates an airspeed meter, a Mach meter, and an altimeter), the error increased from about 5 percent to about 12 percent of the static pressure as the Mach number increased from 2.4 to 4.0 with the airspeed head at an angle of attack of 0 deg.

Silsby, Norman S.↗

Effusion Cell Measurements of the Vapor Pressure of Cobalt at Temperatures up to 2000K; Comparisons with Iron and Nickel

It has become increasingly clear over the past decade that high temperature processes played important roles in the Primitive Solar Nebula. Unfortunately, basic data, such as the vapor pressures of Fe, Ni, Co or SiO have not been measured over the appropriate temperature range (near T approx. 2000K), but must be extrapolated from lower temperature measurements often made more than 50 years ago. The extrapolation of the available data to higher temperatures can be quite complex (e.g., see [1] for SiO vapor pressures) and can depend on other factors such as the oxygen fugacity or the presence of hydrogen gas not accounted for in the original measurements. Moreover, modern technology has made possible more accurate measurements of such quantities over a wider temperature range. We have acquired a commercial Thermo-Cahn Thermogravimetric system capable of vacuum operation to 1700C and measurement of a 10g change in sample mass using up to a 100g sample, with microgram accuracy. With this new system we have initiated a series of basic vapor pressure measurements on simple metals such as Fe[2] and Ni[3] with the intention to extend such measurements to more complex systems once we gain sufficient experience.

Nuth, J. A.↗

A Ground Testing Program to Verify Lunar Dust-Tolerant Hardware for the Artemis Mission

In preparation for NASA’s Artemis Mission that will return humans to the surface of moon by 2024, an extensive test campaign will be undertaken to understand the effects of lunar dust contamination on equipment. Historically, early Apollo astronauts were affected by lunar dust that entered the cabin after their extravehicular activities, and subsequent missions had various cleaning protocols to reduce the impact of the contamination. The longest stays on the lunar surface were Apollo 15, 16, and 17 (just over three days), so equipment and suits were required to operate reliably for a relatively short duration. The ultimate goal of Artemis is a sustained human presence on the lunar surface, beginning with Artemis 3 which targets a six-and-a-half day surface deployment. This requires the design and testing of dust-tolerant infrastructure. Ground testing with aerosolized lunar dust simulants in a specialized chamber is an inexpensive way to verify the performance of equipment. Chambers equipped with various powder dispersers and analysis instrumentation can explore a variety of realistic scenarios relevant to lunar surface missions, from the interaction of dust with sensitive surfaces such as solar panels, textiles, radiators, and scientific equipment, to the effects of dust as it intrudes into habitable areas. These experiments require careful consideration of the expected mass concentrations, aerosolization methods, and transport properties of dust. Instruments that use light-scattering techniques to measure mass concentrations require calibration against lunar simulants for improved accuracy, and different simulants may have different calibration factors. Test facilities, laboratory setup and test methods for aerosolizing lunar simulant will be described along with relevant aerosol instruments and calibration efforts.

Benjamin J Sumlin↗

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell↗

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell↗

Optimal Asteroid Mass Determination from Planetary Range Observations: A Study of a Simplified Test Model

Mars ranging observations are available over the past 10 years with an accuracy of a few meters. Such precise measurements of the Earth-Mars distance provide valuable constraints on the masses of the asteroids perturbing both planets. Today more than 30 asteroid masses have thus been estimated from planetary ranging data (see [1] and [2]). Obtaining unbiased mass estimations is nevertheless difficult. Various systematic errors can be introduced by imperfect reduction of spacecraft tracking observations to planetary ranging data. The large number of asteroids and the limited a priori knowledge of their masses is also an obstacle for parameter selection. Fitting in a model a mass of a negligible perturber, or on the contrary omitting a significant perturber, will induce important bias in determined asteroid masses. In this communication, we investigate a simplified version of the mass determination problem. Instead of planetary ranging observations from spacecraft or radar data, we consider synthetic ranging observations generated with the INPOP [2] ephemeris for a test model containing ~25000 asteroids. We then suggest a method for optimal parameter selection and estimation in this simplified framework.

asteroids↗

A Global End-Member Approach to Derive aCDOM(440) from Near-Surface Optical Measurements

This study establishes an optical inversion scheme for deriving the absorption coefficient of colored (or chromophoric, depending on the literature) dissolved organic material (CDOM) at the 440 nm wavelength, which can be applied to global water masses with near-equal efficacy. The approach uses a ratio of diffuse attenuation coefficient spectral end members, i.e., a short and long wavelength pair. The global perspective is established by sampling "extremely" clear water plus a generalized extent in turbidity and optical properties that each span three decades of dynamic range. A unique data set was collected in oceanic, coastal, and inland waters (as shallow as 0.6 m) from the North Pacific Ocean, the Arctic Ocean, Hawaii, Japan, Puerto Rico, and the east and west coasts of the United States. The data were partitioned using subjective categorizations to define a validation quality subset of conservative water masses, i.e., the inflow and outflow of properties constrain the range in the gradient of a constituent, plus 15 subcategories of water masses that were not evolving conservatively. The dependence on subcategories was confirmed with an objective methodology based on cluster analysis techniques. The latter defined five distinct classes with validation quality data present in all classes, but which also decreased in percent composition as a function of increasing class number and optical complexity. Four different algorithms based on different validation quality end members were validated with accuracies of 1.–6.2 %, wherein pairs with the largest spectral span were most accurate. Although algorithm accuracy decreased with the inclusion of more subcategories containing non-conservative water masses, changes to the algorithm fit were small when a preponderance of subcategories were included. The high accuracy for all end-member algorithms was the result of data acquisition and data processing improvements, e.g., increased vertical sampling resolution to less than 1mm and a boundary constraint to mitigate wave focusing effects, respectively. An independent evaluation with a historical database confirmed the consistency of the algorithmic approach and its application to quality assurance, e.g., to flag data outside expected ranges, identify suspect spectra, and objectively determine the in-water extrapolation interval by converging agreement for all applicable end-member algorithms. The legacy data exhibit degraded performance (as 44 % uncertainty) due to a lack of high-quality near-surface observations, especially for clear waters wherein wave-focusing effects are problematic. The novel optical approach allows the in situ estimation of an in-water constituent in keeping with the accuracy obtained in the laboratory.

Stanford B Hooker↗

Transient natural convection heat and mass transfer in crystal growth

A numerical analysis of transient combined heat and mass transfer across a rectangular cavity is performed by a numerical method based on the SIMPLE algorithm. The physical parameters are selected to represent a range of possible crystal growth in solutions. Numerical results are compared with available experimental data to confirm the accuracy of the results. Good qualitative agreements are obtained for the average mass transfer rate across the cavity. Also, qualitative agreements are observed for the global development of thermal and solute fields. It is found that the thermal and solute fields become highly oscillatory when the thermal and solute Grashof numbers are large. Oscillations are probably caused by a number of different instability mechanisms. By reducing the gravity some of these instabilities were made to disappear at the lower Grashof numbers. Transient temperature and solute distribution near the crystal growing surface are highly non-uniform at the higher Grashof numbers. These non-uniformities are less severe in the reduced gravity environments but still exist. The effects of convection on the rate of average mass transfer are more than one order of magnitude higher than those of conduction in the range of Grashof numbers studied. Dependency of mass transfer rate on the Grashof number indicates that the convection effects many not be negligible even in the microgravity environments for the range of parameters investigated.

Han, Samuel S.↗