Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass gauge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Systematic Study of the Self-Renormalized Nucleon Gluon PDF in Large-Momentum Effective Theory

We present a systematic study of the nucleon gluon parton distribution function (PDF) using the self-renormalized large-momentum effective theory (LaMET) approach in lattice QCD. This work extends previous gluon-PDF extractions by performing a detailed analysis of key systematic effects, including gauge-link smearing, lattice spacing, pion mass, and nucleon boost momentum. The self-renormalization framework mitigates ultraviolet divergences associated with Wilson-line self-energy and renormalon contributions by combining lattice matrix elements with perturbative short-distance information, thereby preserving the correct infrared structure. Calculations are performed on $N_f=2+1+1$ HISQ ensembles generated by the MILC Collaboration at three lattice spacings and two pion masses, with boosted nucleon states reaching momenta up to 2.2~GeV. We determine renormalization factors from zero-momentum matrix elements and apply hybrid renormalization to suppress discretization artifacts. After extrapolating large-separation behavior and performing Fourier transforms, we reconstruct quasi-PDFs and match them to lightcone PDFs using next-to-leading order Wilson coefficients. Our results demonstrate that smearing and lattice-spacing effects are under control, and pion-mass and lattice-spacing dependence is mild relative to the current $O(10^6)$ statistics; however, momentum dependence remains a significant source of uncertainty. Future work including even larger boost momenta will be essential to reduce systematics in lattice determinations of the gluon PDF and to advance toward precision QCD phenomenology at the LHC and the future Electron-Ion Collider.

FOS: Physical sciences↗

Vertical density and temperature structure over northern Europe

Vertical profiles of upper-atmosphere temperature and density over northern Europe constructed from data obtained in November and December 1980, as part of the Energy Budget Campaign, are presented and discussed. Temperature sondes, passive spheres, accelerometers, mass and IR spectrometers, and density gauges were rocket launched from ESRANGE, Sweden and Andoya, Norway; the data are combined with ground measurements to construct 20-120-km-altitude profiles for night periods of severe, moderate, and minimal geomagnetic storm activity. The profiles are compared with each other and with the 1976 U.S. Standard Atmosphere (USSA). In the temperature profiles, increased geomagnetic activity is associated with lower temperatures and flattened profiles in the stratopause region, and higher temperatures in the 70-90-km range. The density profiles show a variation of less than about 15 percent, except for a 25-percent range for the moderate-geomagnetic-activity period. The inferred wavelengths and periods are those expected for internal gravity waves at this altitude, and the divergence from USSA is accounted for by season and latitude dependence.

Philbrick, C. R.↗

The International Space Station (ISS) Port 1 (P1) External Active Thermal Control System (EATCS) Ammonia Leak

From 2011 to 2017, the crew onboard the International Space Station (ISS) was at risk of dire consequences due to an external ammonia leak. Ammonia is used in the External Active Thermal Control System (EATCS) to cool the pressurized modules and external electrical systems. Engineers at NASA's Johnson Space Center (JSC) initially detected the leak in one of two cooling loops by monitoring the system ammonia inventory decay over time. White flakes seen on High Definition (HD) cameras were also thought to be associated with the leakage but not confirmed. Initially, the leak was small enough that the ammonia inventory and system operations were not in jeopardy. However, the leak began to accelerate to the point where troubleshooting and corrective action were vital to the sustainability of the ISS. Therefore, it became imperative that the leak be located and repaired for ISS operations to continue. No tools were readily available on the ISS to locate such a leak when it was initially detected, however NASA engineers were already in the process of developing a new device for this purpose called the Robotic External Leak Locator (RELL). The RELL is a robotic instrument package with a mass spectrometer and an ion pressure gauge. Initial checkout operations with RELL happened to coincide with the increasing leak, and ammonia vapors were measured around the P1 EATCS Radiator #3 flexible jumper hoses. The leak stopped after the radiator and its flexible hoses were remotely isolated from the loop and the ammonia from the isolated segment was vented to space. Astronauts conducted a spacewalk that successfully removed the hoses, which were returned to ground for further investigation. The purpose of this paper is to review the leak detection and isolation efforts, investigation results, lessons learned and the recovery plan.

Cowan, Darnell T.↗

The International Space Station (ISS) Port 1 (P1) External Active Thermal Control System (EATCS) Ammonia Leak

From 2011 to 2017, the crew onboard the International Space Station (ISS) was at risk of dire consequences due to an external ammonia leak. Ammonia is used in the External Active Thermal Control System (EATCS) to cool the pressurized modules and external electrical systems. Engineers at NASA's Johnson Space Center (JSC) initially detected the leak in one of two cooling loops by monitoring the system ammonia inventory decay over time. White flakes seen on High Definition (HD) cameras were also thought to be associated with the leakage but not confirmed. Initially, the leak was small enough that the ammonia inventory and system operations were not in jeopardy. However, the leak began to accelerate to the point where troubleshooting and corrective action were vital to the sustainability of the ISS. Therefore, it became imperative that the leak be located and repaired for ISS operations to continue. No tools were readily available on the ISS to locate such a leak when it was initially detected, however NASA engineers were already in the process of developing a new device for this purpose called the Robotic External Leak Locator (RELL). The RELL is a robotic instrument package with a mass spectrometer and an ion pressure gauge. Initial checkout operations with RELL happened to coincide with the increasing leak, and ammonia vapors were measured around the P1 EATCS Radiator #3 flexible jumper hoses. The leak stopped after the radiator and its flexible hoses were remotely isolated from the loop and the ammonia from the isolated segment was vented to space. Astronauts conducted a spacewalk that successfully removed the hoses, which were returned to ground for further investigation. The purpose of this paper is to review the leak detection and isolation efforts, investigation results, lessons learned and the recovery plan.

Cowan, Darnell T.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

Some astrophysical consequences of the existence of a heavy stable neutral lepton

It is suggested that a stable, massive, neutral lepton may dominate the present mass density in the universe. To investigate this assumption, attention is given to an analysis of extended gauge theories as they apply to a lepton with a mass of a few GeV/sq cm. A critical factor in the accuracy of the hypothesis is the actual mass of the lepton, and it is noted that the more massive the individual particle, the smaller the particle's aggregate contribution to the universal mass density. High energy accelerators could prove a useful tool in an empirical determination of the lepton's mass. It is further suggested that the lepton considered might provide the material in galactic halos, or supply the mass necessary to bind galactic clusters. A study of intergalactic annihilation radiation is expected to yield more data pertaining to the lepton's existence.

Gunn, J. E.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. It has been estimated that once the fiber-optic gauges are put into operation, it should be possible to determine fluid masses with 3 percent or less. It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank supporting legs.

Figueroa, Jorge↗

Seasonal Seismicity in the Lake Biwa Region of Central Japan Moderately Modulated by Lake Water Storage Changes

Seasonal seismicity in Japan has been observed and attributed to variations induced by hydrological loading, as well as atmospheric and pore-fluid pressure. We examine the seasonal variations of crustal (<15 km depth) and low magnitude (M < 4.5) earthquakes in central Japan near the Biwako-Seigan Fault Zone (BSFZ), and analyze their correlation with the annual hydrological cycle of nearby Lake Biwa, the largest freshwater lake in Japan. The 2002–2018 lake water storage is estimated using water-level gauge and satellite altimetry data. Regional surface mass loading from soil moisture and snow predicted by the Global Land Data Assimilation System is used to augment the lake mass variation. We compute the stress and stressing-rate changes induced by the surface mass loading from lake storage, snow, and soil moisture at seismogenic depth (10 km) along the BSFZ using a finite element model incorporating a 3D Earth structure. The results show that seasonal surface mass loading generates 1–5 kPa peak-to-peak Coulomb stress change and 2.5–15 kPa/year stressing-rate variations on the fault segments along the BSFZ. Two of the four fault segments present significant correlation between local seismicity rate and loading-derived stress and/or stressing rate changes. Among the hydrological load components, lake water, snow, and soil moisture exhibit different annual phases, and the lake water storage dominates the total annual stress changes. Our analysis indicates that seasonal surface hydrological loads, especially lake water variations, modulate the seismicity rate along the BSFZ in central Japan.

58 GEOSCIENCES↗

Structure of domain walls in chiral spin liquids

The chiral spin liquid is a canonical state of quantum spins combining topological and symmetry-breaking order, and possible experimental realizations have attracted growing interest. We examine the physics at interfaces between chiral spin liquid domains of opposite chirality. We show that a self-consistent mean-field description of spinons remains possible in the vicinity of a domain wall and use this to formulate a Ginzburg–Landau theory of the domain wall. The bulk of a chiral spin liquid contains gapped spinon excitations and gauge fluctuations, set by a finite spinon mass and a nonzero spinon Chern number. A third class of excitations consists of amplitude fluctuations of the spinon hoppings, which admit a geometric interpretation in terms of effective vielbein fields. These fluctuations are usually neglected because they are irrelevant for a homogeneous chiral spin liquid and are suppressed in standard large- N treatments. Going beyond the purely topological Chern–Simons limit, we incorporate these fluctuations into an effective field theoretic framework and show that they generate momentum-dependent corrections, including Chern–Simons-like linear terms and higher-order contributions, beyond the universal topological limit. We then analyze nontopological properties, including domain wall tension and edge velocity, and explain how they modify observables relative to the uniform case. These results connect measurable, nonuniversal quantities such as domain wall width, domain wall tension, and edge velocity to microscopic parameters and provide concrete targets for experiments.

domain walls↗

Light scalar meson and decay constant in SU(3) gauge theory with eight dynamical flavors

The SU(3) gauge theory with N f = 8 nearly massless Dirac fermions has long been of theoretical and phenomenological interest due to the near-conformality arising from its proximity to the conformal window. One particularly interesting feature is the emergence of a relatively light, stable flavor-singlet scalar meson σ ( J P C = 0 + + ) in contrast to the N f = 2 theory QCD. In this work, we study the finite-volume dependence of the σ meson correlation function computed in lattice gauge theory and determine the σ meson mass and decay constant extrapolated to the infinite-volume limit. We also determine the infinite-volume mass and decay constant of the flavor-nonsinglet scalar meson a 0 . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New nonrenormalization theorem from UV/IR mixing

In this paper, we prove a new nonrenormalization theorem which arises from UV/IR mixing. This theorem and its corollaries are relevant for all four-dimensional perturbative tachyon-free closed string theories which can be realized from higher-dimensional theories via geometric compactifications. As such, our theorem therefore holds regardless of the presence or absence of spacetime supersymmetry and regardless of the gauge symmetries or matter content involved. This theorem resolves a hidden clash between modular invariance and the process of decompactification, and enables us to uncover a number of surprising phenomenological properties of these theories. Chief among these is the fact that certain physical quantities within such theories cannot exhibit logarithmic or power-law running and instead enter an effective fixed-point regime above the compactification scale. This cessation of running occurs as the result of the UV/IR mixing inherent in the theory. These effects apply not only for gauge couplings but also for the Higgs mass and other quantities of phenomenological interest, thereby eliminating the logarithmic and/or power-law running that might have otherwise appeared for such quantities. These results illustrate the power of UV/IR mixing to tame divergences—even without supersymmetry—and reinforce the notion that UV/IR mixing may play a vital role in resolving hierarchy problems without supersymmetry. Published by the American Physical Society 2024

Abel, Steven (ORCID:000000031213907X)↗

Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

Prior to the full-scale wind tunnel test of the UH-60A Airloads rotor, a shake test was completed on the Large Rotor Test Apparatus. The goal of the shake test was to characterize the oscillatory response of the test rig and provide a dynamic calibration of the balance to accurately measure vibratory hub loads. This paper provides a summary of the shake test results, including balance, shaft bending gauge, and accelerometer measurements. Sensitivity to hub mass and angle of attack were investigated during the shake test. Hub mass was found to have an important impact on the vibratory forces and moments measured at the balance, especially near the UH-60A 4/rev frequency. Comparisons were made between the accelerometer data and an existing finite-element model, showing agreement on mode shapes, but not on natural frequencies. Finally, the results of a simple dynamic calibration are presented, showing the effects of changes in hub mass. The results show that the shake test data can be used to correct in-plane loads measurements up to 10 Hz and normal loads up to 30 Hz.

Large Rotor Test Apparatus↗

Shake Test Results and Dynamic Characterization of the Large Rotor Test Apparatus in the NFAC 40- by 80-Foot Wind Tunnel

Prior to the full-scale wind tunnel test of the UH-60A Airloads rotor, a shake test was completed on the Large Rotor Test Apparatus. The goal of the shake test was to characterize the oscillatory response of the test rig and provide a dynamic calibration of the balance to permit accurate measurement of vibratory hub loads. This paper provides a summary of the shake test results, including balance, shaft bending gauge, and accelerometer measurements. Sensitivity to hub mass and angle of attack were investigated during the shake test. Hub mass was found to have an important impact on the vibratory forces and moments measured at the balance, especially near the UH-60A 4/rev frequency. Comparisons were made between the accelerometer data and an existing finite-element model, showing agreement on mode shapes, but not on natural frequencies. The results suggest that the shake test data can be used to correct in-plane loads measurements up to 10 Hz and normal loads up to 30 Hz.

Shake Test↗

Backgrounds in gravitational effective field theory

Effective field theories describing gravity coupled to matter are investigated, allowing for operators of arbitrary mass dimension. Terms violating local Lorentz and diffeomorphism invariance while preserving internal gauge symmetries are included. The theoretical framework for violations of local Lorentz and diffeomorphism invariance and associated conceptual issues are discussed, including transformations in curved and approximately flat spacetimes, the treatment of various types of backgrounds, the implications of symmetry breaking, and the no-go constraints for explicit violation in Riemann geometry. Furthermore, techniques are presented for the construction of effective operators, and the possible terms in the gravity, gauge, fermion, and scalar sectors are classified and enumerated. Explicit expressions are obtained for terms containing operators of mass dimension six or less in the effective action for General Relativity coupled to the Standard Model of particle physics. Special cases considered include Einstein-Maxwell effective field theories and the limit with only scalar coupling constants.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Minimal dark 𝑆⁢𝑈⁡(2) origin of a massless Dirac neutrino

We propose a gauge-symmetry origin of a rank-two Dirac neutrino mass matrix that enforces one exactly massless neutrino, while being consistent with the oscillation data, as well as cosmological constraints. The mechanism relies on a minimal dark 𝑆⁢𝑈⁢(2) 𝐷 gauge symmetry under which one right-handed neutrinolike Weyl fermion is charged, thereby forbidding its Standard Model Yukawa coupling. Quantum consistency then fixes the minimal dark-sector completion: Cancellation of the Witten anomaly requires a second fermionic 𝑆⁢𝑈⁢(2) 𝐷 doublet, while a discrete 𝑍 4 symmetry that forbids Majorana masses allows the two dark doublets to form a vectorlike pair. This anomaly-free completion gives rise to a secluded, confining dark sector that can contain a potential dark matter candidate, linking the protected neutrino texture to dark infrared dynamics.

confinement↗

Lattice determination of 𝐼=0 and 2 𝜋⁢𝜋 scattering phase shifts with a physical pion mass

Phase shifts for 𝑠-wave 𝜋⁢𝜋 scattering in both the 𝐼 =0 and 𝐼 =2 channels are determined from a lattice QCD calculation performed on 741 gauge configurations obeying G-parity boundary conditions with a physical pion mass and lattice size of 32 3 ×64. These results support our recent 2021 study of direct 𝐶⁢𝑃 violation in 𝐾 → 𝜋⁢𝜋 decay, improving our earlier 2015 calculation. The phase shifts are determined for both stationary and moving 𝜋⁢𝜋 systems, at three (𝐼 = 0) and four (𝐼 = 2) different total momenta. We implement several 𝜋⁢𝜋 interpolating operators including a scalar bilinear “𝜎” operator and paired single-pion bilinear operators with the constituent pions carrying various relative momenta. Several techniques, including correlated fitting and a bootstrap determination of p-values have been used to refine the results and a comparison with the generalized eigenvalue problem method is given. A detailed systematic error analysis is performed which allows phase shift results to be presented at a fixed energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino Masses from Generalized Symmetry Breaking

We explore generalized global symmetries in theories of physics beyond the standard model. Theories of Z ′ bosons generically contain “noninvertible” chiral symmetries, whose presence indicates a natural paradigm to break this symmetry by an exponentially small amount in an ultraviolet completion. For example, in models of gauged lepton family difference such as the phenomenologically well motivated U ( 1 ) L μ − L τ , there is a noninvertible lepton number symmetry which protects neutrino masses. We embed these theories in gauged non-Abelian horizontal lepton symmetries, e.g., U ( 1 ) L μ − L τ ⊂ SU ( 3 ) H , where the generalized symmetries are broken nonperturbatively by the existence of lepton family magnetic monopoles. In such theories, either Majorana or Dirac neutrino masses may be generated through quantum gauge theory effects from the charged lepton Yukawas, e.g., y ν ∼ y τ exp ( − S inst ) . These theories require no bevy of new fields nor additional global symmetries but are instead simple, natural, and predictive: The discovery of a lepton family Z ′ at low energies will reveal the scale at which L μ − L τ emerges from a larger gauge symmetry. Published by the American Physical Society 2024

Córdova, Clay (ORCID:0000000205793295)↗