Search NASA⌕ Search

SEARCH · Search NASA

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Nanoporous framework materials interfaced with mechanical sensors for highly-sensitive chemical sensing.

We will describe how novel nanoporous framework materials (NFM) such as metal-organic frameworks (MOFs) can be interfaced with common mechanical sensors, such as surface acoustic wave (SAW), microcantilever array, and quartz crystal microbalance (QCM) devices, and subsequently be used to provide selectivity and sensitivity to a broad range of analytes including explosives, nerve agents, and volatile organic compounds (VOCs). NFM are highly ordered, crystalline materials with considerable synthetic flexibility resulting from the presence of both organic and inorganic components within their structure. Chemical detection using micro-electro-mechanical-systems (MEMS) devices (i.e. SAWs, microcantilevers) requires the use of recognition layers to impart selectivity. Unlike traditional organic polymers, which are dense, the nanoporosity and ultrahigh surface areas of NFM allow for greater analyte uptake and enhance transport into and out of the sensing layer. This enhancement over traditional coatings leads to improved response times and greater sensitivity, while their ordered structure allows chemical tuning to impart selectivity. We describe here experiments and modeling aimed at creating NFM layers tailored to the detection of water vapor, explosives, CWMD, and volatile organic compound (VOCs), and their integration with the surfaces of MEMS devices. Molecular simulation shows that a high degree of chemical selectivity is feasible. For example, a suite of MOFs can select for strongly interacting organics (explosives, CWMD) vs. lighter volatile organics at trace concentrations. At higher gas pressures, the CWMD are deselected in favor of the volatile organics. We will also demonstrate the integration of various NFM on the surface of microcantiliver arrays, QCM crystals, and SAW devices, and describe new synthetic methods developed to improve the quality of NFM coatings. Finally, MOF-coated MEMS devices show how temperature changes can be tuned to improve response times, selectivity, and sensitivity.

36 MATERIALS SCIENCE↗

Structural Health Monitoring of Composite Materials Using Distributed Fiber Bragg Sensors

Health monitoring of polymer matrix composite materials using fiber optic Bragg grating (FBG) sensors is accomplished using a tunable IR (infrared) laser via transmission mode. Results are presented from experiments of composite structures with FBG's embedded at various orientations, and surface measurements of various cryogenic composite vessels.

Grant, Joseph↗

Capacitance-Based Dimensional Change Sensors for In-Pile Materials Measurements

Advanced fuel compositions, such as accident tolerate fuels (ATF), are an active area of developing in the nuclear power industry. The long-term performance of these newly developed fuels is estimated through physics-based simulation models of irradiation-, temperature-, pressure-, etc.-induced material degradation. As these fuels are deployed in test reactors, measurement and characterization of the fuel pin evolution is used to validate prediction models. In-pile material evolution parameters, such as fuel rod pressurization, fuel stack and cladding elongation, and cladding diameter, are commonly measured using a linear voltage differential transformer (LVDT). However, LVDTs are bulky and limited to lower (350-500C) temperature operation. The high power density and small size of most experimental positions in high performance research reactors used for accelerated materials irradiation studies generally precludes the use of LVDTs in these reactors. There is a critical need for sensors that provide real-time data regarding material evolution under highly accelerated irradiation. These sensors would ideally have a small profile and the ability to withstand irradiation at extremely high dose rates and temperatures for extended periods of time. A capacitance-based sensor is currently under development at the University of Tennessee to provide a direct measurement of in-pile dimensional change during irradiation. Sensor response was simulated using AutoCAD Electromagnetic field simulator (EMS) for a variety of sensor materials and configurations and fuel pin swelling conditions. Initial results of these simulations are summarized and areas of ongoing research and development are discussed.

Naughton, Tyler↗

Optical fiber sensors for damage analysis in aerospace materials

Under this grant, fiber optic sensors were investigated for use in the nondestructive evaluation of aging aircraft. Specifically, optical fiber sensors for detection and location of impacts on a surface, and for detection of corrosion in metals were developed. The use of neural networks was investigated for determining impact location by processing the output of a network of fiberoptic strain sensors distributed on a surface. This approach employs triangulation to determine location by comparing the arrival times at several sensors, of the acoustic signal generated by the impact. For this study, a neural network simulator running on a personal computer was used to train a network using a back-propagation algorithm. Fiber optic extrinsic Fabry-Perot interferometer (EFPI) strain sensors are attached to or embedded in the surface, so that stress waves emanating from an impact can be detected. The ability of the network to determine impact location by time-or-arrival of acoustic signals was assessed by comparing network outputs with actual experimental results using impacts on a panel instrumented with optical fiber sensors. Using the neural network to process the sensor outputs, the impact location can be inferred to centimeter range accuracy directly from the arrival time data. In addition, the network can be trained to determine impact location, regardless of material anisotropy. Results demonstrate that a back-propagation network identifies impact location for an anisotropic graphite/bismaleimide plate with the same accuracy as that for an isotropic aluminum plate. Two different approaches were investigated for the development of fiber optic sensors for corrosion detection in metals, both utilizing optical fiber sensors with metal coatings. In the first approach, an extrinsic Fabry-Perot interferometric fiber optic strain sensor was placed under tensile stress, and while in the resulting strained position, a thick coating of metal was applied. Due to an increase in the quantity of material, the sensor does not return to its original position upon removal of the applied stress, and some residual strain is maintained within the sensor element. As the metal thickness decreases due to corrosion, this strain is released, providing the sensing mechanism for corrosion detection. In the second approach, photosensitive optical fibers with long period Bragg gratings in the core were coated with metal. The Bragg gratings serve to couple core modes at discrete wavelengths to cladding modes. Since cladding modes interact with the metal coating surrounding the fiber cladding, the specific wavelengths coupled from core to cladding depend on the refractive index of the metal coating. Therefore, as the metal corrodes, the resulting change in index of the coating may be measured by measuring the change in wavelength of the coupled mode. Results demonstrate that both approaches can be successfully used to track the loss in metal coating on the optical fiber sensors due to corrosion.

Schindler, Paul↗

FRET Imaging of Diatoms Expressing a Biosilica-Localized Ribose Sensor

Future materials are envisioned to include bio-assembled, hybrid, three-dimensional nanosystems that incorporate functional proteins. Diatoms are amenable to genetic modification that enables localization of recombinant proteins in the biosilica cell wall. Our objective was to functionalize diatom biosilica with a reagent-less biosensor with FRET-based imaging capabilities for signaling. The design of the fusion protein conferring these properties included a bacterial periplasmic ribose binding protein (R) flanked by CyPet (C) and YPet (Y), cyan and yellow fluorescent proteins that act as a FRET pair. The structure and function of the recombinant chimeric protein was first confirmed in E. coli-expressed proteins, prior to transformation of the diatom Thalassiosira pseudonana. Mass spectrometry of CRY showed 95% identity with the deduced amino acid sequence. CRY with and without an N-terminal Sil3 tag for biosilica targeting exhibited characteristic ribose-dependent changes in FRET, with similar dissociation constants of 123.3 {mu}M and 142.8 {mu}M, respectively. The addition of the silaffin tag for biosilica localization did not influence the affinity of CRY for the ribose substrate. Subsequent transformation of T. pseudonana with a vector encoding Sil3-CRY resulted in fluorescence localization in the biosilica and changes in FRET in both living cells and isolated biosilica in response to ribose. This work demonstrated that the nano-architecture of the genetically modified biosilica cell wall was able to support the functionality of the relatively complex Sil3-CyPet-RBP-YPet fusion protein with its requirement for ligand binding and conformational change for FRET-signal generation.

59 BASIC BIOLOGICAL SCIENCES↗

Automation of materials processing

Sensors, instruments, and components which will be involved in automation of off-planet resource processing are discussed. The role of smart components in these activities is addressed. Process-specific control issues are briefly considered.

Suitor, Jerry↗

Upconverting nanoparticles for optimizing scintillator based detection systems

An upconverting device for a scintillation detection system is provided. The detection system comprises a scintillator material, a sensor, a light transmission path between the scintillator material and the sensor, and a plurality of upconverting nanoparticles particles positioned in the light transmission path.

47 OTHER INSTRUMENTATION↗

Wireless sensor

Disclosed is a sensor for detecting a target material. The sensor includes a ferromagnetic metal and a molecular recognition reagent coupled to the ferromagnetic metal. The molecular recognition reagent is operable to expand upon exposure to vapor or liquid from the target material such that the molecular recognition reagent changes a tensile stress upon the ferromagnetic metal. The target material is detected based on changes in the magnetic switching characteristics of the ferromagnetic metal caused by the changes in the tensile stress.

36 MATERIALS SCIENCE↗

Noncontacting Thermometer

Proposed laser/ultrasonic thermometer measures bulk and surface temperatures of part without physical contact. No sensors or wire connections needed on part, moving or stationary. Problems of bonding sensors, of mutal diffusion of materials between sensor and part, and of disturbances of fluid and heat flows by sensor avoided. Single thermometer used to measure many parts remotely.

Wyett, Lynn M.↗

High Sensitivity Stress Sensor Based on Hybrid Materials

A sensing device is used to detect the spatial distributions of stresses applied by physical contact with the surface of the sensor or induced by pressure, temperature gradients, and surface absorption. The sensor comprises a hybrid active layer that includes luminophores doped in a polymeric or organic host, altogether embedded in a matrix. Under an electrical bias, the sensor simultaneously converts stresses into electrical and optical signals. Among many applications, the device may be used for tactile sensing and biometric imaging.

Cao, Xian-An↗

Demonstration of Embedded Sensors in Ceramic Structures

The Transformational Challenge Reactor (TCR) program seeks to demonstrate an advanced 3D printed nuclear reactor core. A binder jet additive manufacturing process is used to fabricate the complex SiC ceramic components of the TCR core. After printing, the components are densified via chemical vapor infiltration (CVI). This process allows complex cavities to be created in which sensors can be placed at strategic locations. Inserting the sensors during the CVI process allows the sensors to be embedded within the component as it is infiltrated. The primary challenge for embedding the sensors is identifying the sensors and sensor sheath materials that can survive the temperatures (>1,000°C) and chemical exposure to H 2 and HCl during CVI. The embedded sensors that are being investigated for use during TCR operation include thermocouples, self-powered neutron detectors, and spatially distributed fiber-optic temperature sensors. This report describes the CVI materials compatibility tests and initial trials for embedding functional sensors. Mo is identified as the most suitable sensor sheath material based on its availability in small diameter tubing, relatively low neutron absorption cross section, and compatibility with H 2 , HCl, and the surrounding SiC matrix at the process temperatures. Amorphous SiO2 fiber-optic samples with Au and Cu metal coatings were successfully embedded in SiC along with bare fibers, although the metal coatings showed some evidence of localized melting during CVI. Initial experiments attempting to embed functional sensors showed that the sensors can be embedded in 3D printed SiC parts, but there are still challenges that must be overcome to ensure that the sensors and sensor sheaths do not fail during CVI. In particular, Nb-sheathed Mo-Nb thermocouples failed at temperatures far lower than expected despite thermodynamic calculations and materials compatibility tests that show the Nb sheath to be compatible with the CVI environment. One potential explanation for the large expansion of the Nb sheath could be related to hydride formation in the lower temperature region of the sheath. Future work will focus on Mo-sheathed thermocouples instead of Nb. The fiberoptic sensors tested during the instrumented experiment broke due to the lack of mechanical protection after their polymer-based coatings were vaporized. Future instrumented experiments will use metal-coated optical fibers for strain sensing to provide additional mechanical protection. However, custom coatings with higher melting points than commercially available Au and Cu might be required. Regardless, fiber-optic sensors are still candidates for spatially distributed temperature measurements since they can be inserted into an embedded metal sheath after CVI.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smart structures research program at Virginia Tech

A review of the smart structures and avionics research and teaching program that started in 1979 at Virginia Tech is described. Current smart structures research include major efforts in the development of embedded and attached optical fiber and acoustic fiber sensors for cure monitoring, in-service lifetime structural testing, nondestructive evaluation, and impact and damage detection and analysis; of gradual material degradation; sensor signal multiplexing, processing and data handling to achieve near real-time distributed structural analysis; and the integration of embedded sensors, actuators and control electronics to achieve controlled structural response. Special campus facilities used for this work include an optical fiber fabrication facility, an autoclave for composite structure fabrication and curing, and laboratories for optical fiber sensor development, materials response and nondestructive evaluation, structural control testing and computer engineering.

Claus, R. O.↗

Ultrasensitive and selective non-enzymatic electrochemical glucose sensor based on hybrid material of graphene nanosheets/graphene nanoribbons/nickel nanoparticle

Highlights: • Nickel nanoparticles incorporated graphene nanosheets/graphene nanoribbons (GS/GNR/Ni) composite was synthesized by in-situ chemical reduction route and the as prepared GS/GNR/Ni modified glassy carbon electrode (GCE) was applied to detect glucose. • The fabricated GS/GNR/Ni/GCE modified electrode exhibits outstanding performance for non-enzymatic glucose sensing with sensitivity (2.3 mA/mM cm{sup 2}), linear range (5 nM - 5 mM) and detection limit (2.5 nM). • GS/GNR/Ni/GCE modified electrode exhibited a high selectivity towards glucose against the interferents, such as ascorbic acid (AA), uric acid (UA), dopamine and sucrose. - Abstract: A fast, highly sensitive and selective non-enzymatic electrochemical glucose sensor based on graphene sheet/graphene nanoribbon/nickel nanoparticles (GS/GNR/Ni) hybrid material modified electrode was fabricated. The hybrid material was synthesized via facile in-situ chemical reduction and characterized by X-ray diffraction, transmission electron microscopy, Raman spectroscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The GS/GNR/Ni/GCE showed high electrochemical activity towards the oxidation of glucose in a 0.1 M NaOH solution. At an applied potential of +0.5 V, it displayed wide linear amperometric response towards glucose from the range of 5 nM–5 mM, with a detection limit of 2.5 nM and sensitivity of 2.3 mA/mM cm{sup 2}. Moreover, the modified electrode was relatively insensitive to commonly interfering species such as dopamine, ascorbic acid, sucrose, uric acid and Cl{sup −} ions. The fabricated sensor with better reproducibility, good long term stability, makes it a promising electrode for the development of effective glucose sensor.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tardigrade: Summary (LL20-AM-sensor)

Tardigrade is an effort to create small, passive remote sensor for material detection and identification. The microbolometer based sensor design uses custom bandpass filter bands combined with tuned thermal expansion materials in a ruggedized lens housing to provide passive mechanical correction for optical changes across a wide temperature range. This requires developing computational tools to model and predict thermal performance of meta-materials composed of multiple structured base materials and void-space, along with matching and developing 3D print technology to demonstrate the housing. Current efforts in the project are in 3 areas: material design algorithm development (transitioning into full 3D material design space), multi-material additive manufacturing process exploration, and sensor/optics design and engineering.

42 ENGINEERING↗

Harsh Environment Silicon Carbide Sensor Technology for Geothermal Instrumentation

This project utilizes Silicon Carbide (SiC) materials platform to fabricate advanced sensors to be used as high-temperature downhole instrumentation for the DOE’s Geothermal Technologies Program on Enhanced Geothermal Systems. The scope of the proposed research is to 1) develop a SiC pressure sensor that can operate in harsh supercritical conditions, 2) develop a SiC temperature sensor that can operate in harsh supercritical conditions, 3) develop a bonding process for adhering SiC sensor die to well casing couplers, and 4) perform experimental exposure testing of sensor materials and the sensor devices.

47 OTHER INSTRUMENTATION↗

Novel Harsh Environment Materials and Fabrication Techniques for Wireless Sensor Applications (Final Report)

The overarching goal of this project is to establish a center of excellence program at the University of Maine that is focused on Harsh Environmental Materials and Fabrication Techniques for Wireless Sensor Applications. UMaine is well-positioned to build on previous successes in the areas of materials science research and sensor engineering. Since 1980, the Laboratory for Surface Science & Technology (LASST) has been a very successful interdisciplinary UMaine research center with a well-established infrastructure to investigate surfaces, interfaces, thin films, and micro/nano-fabrication. This infrastructure established through NSF, DOE, DOD, NASA, the State of Maine, and industry includes (i) a 3,500 ft2 clean room with nano/microfabrication and photolithography instrumentation, (ii) thin film synthesis, processing and characterization, (iii) surface and thin film analytical chemistry tools, and (iv) device packaging, electronic testing, wireless devices, system fabrication, and sensor test facilities. This strong foundation is the basis for a planned significant growth in R&D capacity currently underway. To that end, since the start of this project in the Fall of 2019, LASST has undergone a transition to become a new interdisciplinary center at UMaine, named the Frontier Institute for Research in Sensor Technologies (FIRST). This new focus represents a commitment and investment by UMaine that aligns with the proposed DOE-EPSCoR theme, capitalizing on the state-of-the-art instrumentation to form an energized group of faculty and students pursuing advances in sensor materials, devices, and applications.

36 MATERIALS SCIENCE↗

Non-intrusive, high-resolution, real-time, two-dimensional imaging of multiphase materials using acoustic array sensors

Two parallel multi-element ultrasonic acoustic arrays combined with sets of focal laws for acoustic signal generation and a classical tomographic inversion algorithm are used to generate real-time two-dimensional micro seismic acoustic images of multiphase materials. Proof of concept and calibration measurements were performed for single phase and two phase liquids, uniform polyvinyl chloride (PVC) plates, and aluminum cylinders imbedded in PVC plates. Measurement artefacts, arising from the limited range of viewing angles, and the compromise between data acquisition rate and image quality are discussed. The angle range of scanning and the image resolution were varied, and the effects on the quality of the reproduction of the speed of sound profiles of model solids and liquids with known geometries and compositions were analysed in detail. The best image quality results were obtained for a scanning angle range of [−35°, 35°] at a step size of 2.5° post processed to generate images on a 40 μm square grid. The data acquisition time for high quality images with a 30 mm × 40 mm view field is 10 min. Representation of two-phase solids with large differences in speed of sound between phases and where one phase is dispersed in the form of macroscopic objects (greater than 1 mm in diameter) proved to be the most difficult to image accurately. Liquid-liquid and liquid-vapor phase boundaries, in micro porous solids by contrast, were more readily defined. Displacement of air by water and water by heptane in natural porous limestone provides illustrative kinetic examples. Measurement results with these realistic cases demonstrate the feasibility of the technique to monitor in real time and on the micrometer length scale local composition and flow of organic liquids in inorganic porous media, one of many envisioned engineering applications. Improvement of data acquisition rate is an area for future collaborative study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗