Search NASA⌕ Search

SEARCH · Search NASA

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Hawkeye Ocean Color Instrument – Performance Summary

Hawkeye is an ocean color instrument that is part of the SeaHawk satellite developed for SOCON, the Sustained Ocean Color Observations using Nanosatellites program funded by the Gordon and Betty Moore Foundation and managed by the University of North Carolina – Wilmington (UNC-W). HawkEye has spectral characteristics similar to SeaWiFS, but with 8 times finer resolution and a smaller field of view more appropriate for lakes, rivers, and near-shore terrestrial environments. With a volume of only 10 X 10 X 10 cm (a CubeSat 1U), it can produce 8 bands of image data in a single pass, each with 1800 x 6000 pixels, with a resolution of 120 meters per pixel. This paper will present a short summary of instrument design, the spacecraft interface, and “lessons learned” during this effort. Scientists considering using linear arrays in a pushbroom mode for remote sensing will find this useful. Much of the discussion will center on optical performance, such as flat field calibration, polarization effects, stray light, out-of-band response, and exposure linearity. Images from field tests will be shown.The Hawkeye instrument is an ocean color measuring instrument designed to fly on the SeaHawk satellite developed for SOCON, the Sustained Ocean Color Observations using Nanosatellites program funded by the Gordon and Betty Moore Foundation and managed by the University of North Carolina – Wilmington (UNC-W). The Hawkeye instrument measures ocean color in 8 spectral bands, similar to SeaWiFS, except Band 7, which is shifted to a slightly lower wavelength to avoid the oxygen absorption feature that a wider band overlapped on SeaWiFS. The instrument is approximately 1/3rd the volume of the entire satellite, which is a 3U Cubesat manufactured by Clydespace in Glasgow, Scotland. The purpose of this instrument is to ascertain the quality of ocean color data possible with such a small, inexpensive instrument and bus. The nominal orbit is 540 km, and the nominal pixel geometric instantaneous field of view (GIFOV) 120 meters on a side. Each band will produce an image 1800 x 6000 pixels in size, for a total field of view of 216 X 720 km.2) DESIGN CONCEPTThe Hawkeye instrument uses linear arrays in pushbroom mode to collect data over a two dimensional area. The instrument has 4 linear CCD arrays, the Onsemi KLI-4104, to collect the 8 bands of data. Figure 1 illustrates the optical design for two bands, sharing a single array.

Hawkeye↗

Investigation of techniques for correcting ERTS data for solar and atmospheric effects

The author has identified the following significant results. A technique is described by which an ERTS investigator can obtain absolute target reflectances by correcting spacecraft radiance measurements for variable target irradiance, atmospheric attenuation, and atmospheric backscatter. A simple measuring instrument and the necessary atmospheric measurements are discussed, and examples demonstrate the nature and magnitude of the atmospheric corrections. Preliminary results indicate that the radiant power measuring instrument will provide one technique for calibrating ERTS-1 data. The March 27, 1973 mission was significant in the NASA C-130 aircraft and ERTS-1 simultaneously passed over the test sites where RPMI's were being deployed to measure solar and atmospheric parameters and site reflectance.

Rogers, R. H.↗

Ozone Layer Observations

The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical distribution, the SBUV and SAGE (Stratospheric Aerosol and Gas Experiment) instruments for example, show that the largest changes are occurring in the lower stratosphere and upper troposphere. The goal of ozone measurement in the next decades will be to document the predicted recovery of the ozone layer as CFC (chlorofluorocarbon) levels decline. This will require a continuation of global measurements of total column ozone on a global basis, but using data from successor instruments to TOMS. Hyperspectral instruments capable of measuring in the UV will be needed for this purpose. Establishing the relative roles of chemistry and dynamics will require instruments to measure ozone in the troposphere and in the stratosphere with good vertical resolution. Instruments that can measure other chemicals important to ozone formation and destruction will also be needed.

McPeters, Richard↗

Current status and prospects for development of thermometry

The paper deals with results of an analysis carried out at the VNIIM with the purpose to ascertain the current status of thermometry as well as to make an attempt to determine a line of development of this field of measurements in future. The analysis was based on a survey of 150 industrial enterprises and scientific organizations. The results of the survey showed that during two last decades the accuracy of measuring instruments used in science and industry was increased almost tenfold. However, advances in the improvement of temperature measuring instruments were achieved not owing to new principles of designing thermometers, but due to rapid development of electronics, which allowed to solve the problem of accurate measurements of resistance and electromotive force and automatize measurement information processing. In most cases the contemporary measuring instruments perfectly meet the requirements to the measurement accuracy claimed by the enterprises surveyed and are provided with a necessary metrological assurance. Although there is a general understanding of the necessity to use the thermodynamic scale rather than the conditional one, we have no objective evidence with regard to how close we have to bring the international scale used in our everyday practice to the thermodynamic scale and what will be a benefit for development of science and industry. Increasing the accuracy of national standards does not affect, as a rule, the accuracy of temperature measurements in industry and scientific research since the main contribution to a total measurement error is made by components caused by an improper measurement procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable Instrument to Measure CDOM Light Absorption in Aquatic Systems: WPI Success Story

World Precision Instruments, Inc. (WPI), of Sarasota, FL, in collaboration with NASA's John C. Stennis Space Center, has developed an innovative instrument to accurately measure Colored Dissolved Organic Matter (CDOM) absorption in the field. This successful collaboration has culminated in an exciting new device, called the UltraPath, now commercially available through WPI. Traditional methods of measuring absorption of dissolved materials require special handling and storage prior to measurement. Use of laboratory spectrophotometers as the measuring devices have proven time consuming, cumbersome, and delicate to handle. The UltraPath provides a low-cost, highly sensitive, rugged, portable system that is capable of high sensitivity measurements in widely divergent waters.

Source record↗

Developmental long trace profiler using optimally aligned mirror based pentaprism

A low-budget surface slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought into operation at the Advanced Light Source Optical Metrology Laboratory [Nucl. Instr. and Meth. A 616, 212-223 (2010)]. The instrument is based on a precisely calibrated autocollimator and a movable pentaprism. The capability of the DLTP to achieve sub-microradian surface slope metrology has been verified via cross-comparison measurements with other high-performance slope measuring instruments when measuring the same high-quality test optics. In the present work, a further improvement of the DLTP is achieved by replacing the existing bulk pentaprism with a specially designed mirror based pentaprism. A mirror based pentaprism offers the possibility to eliminate systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of a bulk pentaprism. We provide the details of the mirror based pentaprism design and describe an original experimental procedure for precision mutual alignment of the mirrors. The algorithm of the alignment procedure and its efficiency are verified with rigorous ray tracing simulations. Results of measurements of a spherically curved test mirror and a flat test mirror using the original bulk pentaprism are compared with measurements using the new mirror based pentaprism, demonstrating the improved performance.

47 OTHER INSTRUMENTATION↗

Developmental long trace profiler using optimally aligned mirror based pentaprism

A low-budget surface slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought into operation at the Advanced Light Source Optical Metrology Laboratory. The instrument is based on a precisely calibrated autocollimator and a movable pentaprism. The capability of the DLTP to achieve sub-microradian surface slope metrology has been verified via cross-comparison measurements with other high-performance slope measuring instruments when measuring the same high-quality test optics. In the present work, a further improvement of the DLTP is achieved by replacing the existing bulk pentaprism with a specially designed mirror based pentaprism. A mirror based pentaprism offers the possibility to eliminate systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of a bulk pentaprism. We provide the details of the mirror based pentaprism design and describe an original experimental procedure for precision mutual alignment of the mirrors. The algorithm of the alignment procedure and its efficiency are verified with rigorous ray tracing simulations. Results of measurements of a spherically curved test mirror and a flat test mirror using the original bulk pentaprism are compared with measurements using the new mirror based pentaprism, demonstrating the improved performance.

42 ENGINEERING↗

The Fourier Tachometer 2: an Instrument for Measuring Global Solar Velocity Fields

The High Altitude Observatory and Sacramento Peak Observatory have jointly constructed a second version of the Fourier Tachometer, which is now undergoing final integration and testing. This is an interferometric instrument for measuring the Doppler shift of solar spectrum lines. The principal features and performance goals of this instrument are: simultaneous velocity observations over a 2-dimensional, 100 x 100 pixel field of view; measurement of absolute Doppler shifts with 1 m/s accuracy; noise level for moderate-1 oscillation modes of 1 cm/s for a 1-day observing run; flexibility and ease of use. Early (though incomplete) testing suggests that these goals should be attainable with the current instrument.

Brown, T. M.↗

Ground-based instrumentation for measurements of atmospheric conduction current and electric field at the South Pole

Attention is given to instruments constructed to measure the atmospheric conduction current and the atmospheric electric field - two fundamental parameters of the global-electric circuit. The instruments were deployed at the Amundsen-Scott South Pole Station in January 1991 and are designed to operate continuously for up to one year without operator intervention. The atmospheric current flows into one hemisphere, through the electronics where it is measured, and out the other hemisphere. The electric field is measured by a field mill of the rotating dipole type. Sample data from the first days of operation at the South Pole indicate variations in the global circuit over time scales from minutes to hours to days.

Byrne, G. J.↗

Measurement and Instrumentation

This is a chapter for a book called the Standard Handbook for Electrical Engineering. Though it is not obvious from the title, the book deals mainly with power engineering. The first chapter (not mine) is about the fundamental quantities used in measurement. This chapter is about the process and the instrumentation.

instrument technology↗

Contamination effects from materials selected for spacecraft instruments

Measurements of the Total Mass Loss (TML) and the Collected Volatile Condensable Materials (CVCM) are used as a guide for selecting those materials being low in outgassing. A contamination modelling method utilizing the data and also the rate at which a material outgasses in a system with a known conductance has been developed and has been applied to the problem encountered with the Very High Resolution Radiometer (VHRR). Recently, the contamination model has been applied to the problem with the 5th band of the Multi-Spectral Scanner on the Landsat-C satellite. In the MSS design, the volumes involved and their respective conductance in a molecular flow field demonstrated that the water vapor adsorbed and absorbed by an epoxy paint was being pumped off and re-ad(b)sorbed, with a resultant very slow loss of water during each degassing temperature cycle of the instrument's cooler. Recommendations for designing improved coolers are presented.

Heslin, T. M.↗

A high precision instrument to measure angular and binocular deviation introduced by aircraft windscreens by using a shadow casting technique

Objects viewed through transparent sheets with residual non-parallelism and irregularity appear shifted and distorted. This distortion is measured in terms of angular and binocular deviation of an object viewed through the transparent sheet. The angular and binocular deviations introduced are particularly important in the context of aircraft windscreens and canopies as they can interfere with decision making of pilots especially while landing, leading to accidents. In this work, we have developed an instrument to measure both the angular and binocular deviations introduced by transparent sheets. This instrument is especially useful in the qualification of aircraft windscreens and canopies. It measures the deviation in the geometrical shadow cast by a periodic dot pattern trans-illuminated by the distorted light beam from the transparent test specimen compared to the reference pattern. Accurate quantification of the shift in the pattern is obtained by cross-correlating the reference shadow pattern with the specimen shadow pattern and measuring the location of the correlation peak. The developed instrument is handy to use and computes both angular and binocular deviation with an accuracy of less than {+-}0.1 mrad ( Almost-Equal-To 0.036 mrad) and has an excellent repeatability with an error of less than 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two Instruments for Measuring Distributions of Low-Energy Charged Particles in Space

Current estimates indicate that the bulk of interplanetary gas consists of protons with energies between 0 and 20 kev and concentrations of 1 to 105 particles/cu cm. Methods and instrumentation for measuring the energy and density distribution of such a gas are considered from the standpoint of suitability for space vehicle payloads. It is concluded that electrostatic analysis of the energy distribution can provide sufficient information in initial experiments. Both magnetic and electrostatic analyzers should eventually be used. Several instruments designed and constructed at the Ames Research Center for space plasma measurements, and the methods of calibration and data reduction are described. In particular, the instrument designed for operation on solar cell power has the following characteristics: weight, 1.1 pounds; size, 2 by 3 by 4 inches; and power consumption, 145 mw. The instrument is designed to yield information on the concentration, energy distribution, and the anisotropy of ion trajectories in the 0.2 to 20 kev range.

Bader, Michel↗

Water surface depth instrument

Measurement gage provides instant visual indication of water depth based on capillary action and light diffraction in a group of solid, highly polished polymethyl methacrylate rods. Rod lengths are adjustable to measure various water depths in any desired increments.

Davis, Q. C., IV↗

Water detection at the moon, Mars and comets with a combined neutron gamma ray instrument

Measuring the fluxes of thermal and epithermal neutrons at a planetary object in conjunction with gamma-ray spectroscopic observations will provide information about the chemical composition of the surface which is less model dependent than the gamma ray measurements by themselves. Researchers devised a passive neutron detector for this purpose. An experimental model was designed and built. Three variables provided the basis for a set of experiments: thickness of the Sm and B layers, the presence or absence of the ACS, and the position of the source relative to the PND's cylindrical axis. Experimental results are given.

Metzger, Albert E.↗