Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Assembly and testing of a 1.8 by 3.7 meter Fresnel lens solar concentrator

A project was initiated to establish a technical data base on line focusing acrylic Fresnel lenses for use in a solar collector system that could generate temperatures in the range of 200 C to 370 C. The effort was originally directed toward electric power generation in the 100 to 10,000 kWe range using a distributed collector approach. However, as the program progressed, it centered on the development of a concentrator/collector subsystem concept that could meet the general requirement of thermal delivery within the 200 C to 370 C range. The expanded list of possible applications includes commercial heating/cooling and industrial process heat as well as electric power generation.

Robertson, J. E.↗

Wall adjustment strategy software for use with the NASA Langley 0.3-meter transonic cryogenic tunnel adaptive wall test section

The Wall Adjustment Strategy (WAS) software provides successful on-line control of the 2-D flexible walled test section of the Langley 0.3-m Transonic Cryogenic Tunnel. This software package allows the level of operator intervention to be regulated as necessary for research and production type 2-D testing using and Adaptive Wall Test Section (AWTS). The software is designed to accept modification for future requirements, such as 3-D testing, with a minimum of complexity. The WAS software described is an attempt to provide a user friendly package which could be used to control any flexible walled AWTS. Control system constraints influence the details of data transfer, not the data type. Then this entire software package could be used in different control systems, if suitable interface software is available. A complete overview of the software highlights the data flow paths, the modular architecture of the software and the various operating and analysis modes available. A detailed description of the software modules includes listings of the code. A user's manual is provided to explain task generation, operating environment, user options and what to expect at execution.

Wolf, Stephen W. D.↗

Use of 3000 Bragg Grating Strain Sensors Distributed on Four Eight-meter Optical Fibers During Static Load Tests of a Composite Structure

This paper describes the use of a fiber optic system to measure strain at thousands of locations along optical fibers where weakly reflecting Bragg gratings have been photoetched. The optical fibers were applied to an advanced composite transport wing along with conventional foil strain gages. A comparison of the fiber optic and foil gage systems used for this test will be presented including: a brief description of both strain data systems; a discussion of the process used for installation of the optical fiber; comparative data from the composite wing test; the processes used for the location and display of the high density fiber optic data. Calibration data demonstrating the potential accuracy of the fiber optic system will also be presented. The opportunities for industrial and commercial applications will be discussed. The fiber optic technique is shown to be a valuable augmentation to foil strain gages providing insight to structural behavior previously requiring reliance on modeling.

Childers, Brooks A.↗

Using FENOSOL{sup TM} Phenolic Foam as a Shock Absorber for Type B Packaging - 17256

Type B and fissile material transportation packages are designed to withstand deformation from dynamic forces experienced during impacts in hypothetical accident conditions. A critical aspect is to ensure the containment system is not breached. The package design normally includes impact limiters made up of a shell filled with energy-absorbing material. Various types of materials are used as energy absorbers, including wood, foam, and honeycomb structures. Synthetic foam is an ideal material for impact limiters; it has isotropic material properties, it acts as a heat insulator during fire conditions, and it maintains structural integrity at high temperatures. In addition, the density of the foam may be controlled during the manufacturing process, allowing the cask designer flexibility to select the right density for each application. The foam properties can be used as inputs for numerical simulations of dynamic impacts. These simulations are a key component of the safety analysis report for Type B transportation casks. Robatel has recently invested in equipment to produce FENOSOL{sup TM} phenolic foam in our factory for use in our cask designs. This acquisition was made jointly between Robatel and the CEA, with Robatel ensuring the industrialization of the product. In the past decade, this foam was successfully integrated into more than 10 European cask designs, and there has been extensive in-laboratory characterization of its properties. FENOSOL{sup TM} has already been accepted by the French Nuclear Safety Authority (ASN) as a shock absorbing material for use in cask designs. Since the acquisition of the phenolic foam production process by Robatel, a new research and development program has been launched to provide more accurate information to our clients, extend the range of application of this foam, and to improve its properties. Robatel has built an extensive database of material characteristics through the use of a universal mechanical tester, a scanning electron microscope, and a nuclear magnetic resonance spectrometer. In addition, Robatel has successfully implemented FENOSOL{sup TM} in two recent cask designs. This included scale model drop testing of a 9 meter drop in three orientations, and a pin puncture drop test. Robatel is in the process of producing FENOSOL{sup TM} samples for testing according to ASTM standards. Various densities will be included in the study. The testing will include duro-meter hardness, specific heat, thermal conductivity, compressive strength and modulus, and tensile strength. Once the testing is complete, Robatel will compile the data in the form of product specification sheets for each density. These information sheets and test reports will be used to validate FENOSOL{sup TM} for use in future impact limiters for the North American Type B cask market. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characteristics and status of the US National Transonic Facility

A major application of the cryogenic wind tunnel concept is discussed. A closed return fan driven circuit with a 2.5 meter square slotted test section, pressurized up to 8.85 atmospheres, and providing chord Reynolds numbers of 120 million based on a chord of 0.25 meter at transonic speeds using cold nitrogen as the test gas is described.

Igoe, W. B.↗

Data from tests of a R4 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

Aerodynamic data for the DFVLR R4 airfoil are presented in both graphic and tabular form. The R4 was tested in the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT) at Mach number from 0.60 to 0.78 at angles of attack from -2.0 to 8.0 degrees. The airfoil was tested at Reynolds numbers of 4, 6, 10, 15, 30, and 40 million based on the 152.32 mm chord.

Jenkins, R. V.↗

Highlights of experience with a flexible walled test section in the NASA Langley 0.3-meter transonic cryogenic tunnel

The unique combination of adaptive wall technology with a contonuous flow cryogenic wind tunnel is described. This powerful combination allows wind tunnel users to carry out 2-D tests at flight Reynolds numbers with wall interference essentially eliminated. Validation testing was conducted to support this claim using well tested symmetrical and cambered airfoils at transonic speeds and high Reynolds numbers. The test section hardware has four solid walls, with the floor and ceiling flexible. The method of adapting/shaping the floor and ceiling to eliminate top and bottom wall interference at its source is outlined. Data comparisons for different size models tested and others in several sophisticated 2-D wind tunnels are made. In addition, the effects of Reynolds number, testing at high lift with associated large flexible wall movements, the uniqueness of the adapted wall shapes, and the effects of sidewall boundary layer control are examined. The 0.3-m TCT is now the most advanced 2-D research facility anywhere.

Wolf, Stephen W. D.↗

High Reynolds number tests of the cast 10-2/DOA 2 airfoil in the Langley 0.3-meter transonic cryogenic tunnel, phase 2

Wind tunnel tests of an advanced technology airfoil, the CAST 10-2/DOA 2, were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). This was the third of a series of tests conducted in a cooperative airfoil research program between the National Aeronautics and Space Administration and the Deutsche Forschungsund Versuchsanstalt fur Luft- und Raumfahrt e. V. For these tests, temperature was varied from 270 K to 110 K at pressures from 1.5 to 5.75 atmospheres. Mach number was varied from 0.60 to 0.80, and the Reynolds number (based on airfoil chord) was varied from 2 to 20 million. The aerodynamic data for the 7.62 cm chord airfoil model used in these tests is presented without analysis. Descriptions of the 0.3-m TCT, the airfoil model, the test instrumentation, and the testing procedures are included.

Dress, D. A.↗

Cold-Flow Model Tests to Determine Static Performance of a NASA One-Sided Ejector Nozzle System

This report presents the results of cold-flow model tests to determine the static performance of multiple configurations of a NASA one-sided ejector nozzle system. The existing ejector nozzle system hardware was provided by NASA and was previously used for acoustic tests. A new facility adapter duct and ejector box support brackets were designed and fabricated by the FluiDyne Aerotest Laboratory of Aero Systems Engineering, Inc. The tests were performed in the Channel 8 static thrust stand at ASE’s FluiDyne Aerotest Laboratory in Plymouth, Minnesota. Facility checkout tests were made using a standard American Society of Mechanical Engineers (ASME) long-radius metering nozzle. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 8 static tests included 40 ASME nozzle facility checkout tests and 24 model tests (plus an additional 1 at no charge). The model nozzle pressure ratio varied from 1.4 to 3.0. Test results include: thrust coefficients, thrust vector angles and location, nozzle discharge coefficients, charging station total and static pressures, and model static pressure distributions (in the Data Appendix).

McDonald, Timothy J.↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

The indirect effects on the computation of geoid undulations

The indirect effects on the geoid computation due to the second method of Helmert's condensation were studied. when Helmert's anomalies are used in Stokes's equation, there are three types of corrections to the free air geoid. The first correction, the indirect effect on geoid undulation due to the potential change in Helmert's reduction, had a maximum value of 0.51 meters in the test area covering the United States. The second correction, the attraction change effect on geoid undulation, had a maximum value of 9.50 meters when the 10 deg cap was used in Stokes' equation. The last correction, the secondary indirect effect on geoid undulatin, was found negligible in the test area. The corrections were applied to uncorrected free air geoid undulations at 65 Doppler stations in the test area and compared with the Doppler undulations. Based on the assumption that the Doppler coordinate system has a z shift of 4 meters with respect to the geocenter, these comparisons showed that the corrections presented in this study yielded improved values of gravimetric undulations.

Wichiencharoen, C.↗

Highlights of experience with a flexible walled test section in the NASA Langley 0.3-meter transonic cryogenic tunnel

The unique combination of adaptive wall technology with a continuous flow cryogenic wind tunnel is described. This powerful combination allows wind tunnel users to carry out two-dimensional (2-D) tests at flight Reynolds numbers with wall interferences essentially eliminated. Validation testing was conducted to support this claim using well tested symmetrical and cambered airfoils at transonic speeds and high Reynolds numbers. The test section hardware has four solid walls, with the floor and ceiling flexible. The method of adapting/shaping the floor and ceiling to eliminate top and bottom wall interference at its source is outlined. Data comparisons for different size models tested and others in several sophisticated 2-D wind tunnels are made. In addition, the effects of Reynolds number, testing at high lift with associated large flexible wall movements, the uniqueness of the adapted wall shapes, and the effects of sidewall boundary layer control are examined. The 0.3-m TCT is now the most advanced 2-D research facility anywhere.

Wolf, Stephen W. D.↗

Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

Gazda, Daniel B.↗

The development of the 15-Meter Hoop Column deployable antenna system with structural and electromagnetic performance results

This paper presents the technical results obtained during the development and engineering tests of a 15-Meter Hoop Column deployable antenna system. An important element of the 15-meter antenna program was the structural tests and the characterization of the surface accuracy of the deployed mesh surface. The overall system performance of the 15-meter antenna was obtained during radio frequency tests conducted in the Martin Marietta Near Field Test Laboratory in Denver, CO. The near field tests verified the electromagnetic performance of the structure which exhibited a surface accuracy of 0.061 in (RMS). Radio frequency tests were conducted at 2.3, 4.3, 7.7, and 11.6 GHz. The experiment and analytical results obtained through the 15-meter antenna program will provide new opportunities for the application of large space antennas for future missions.

Campbell, T. G.↗

Flight Test of a 30-Foot Nominal Diameter Cross Parachute Deployed at a Mach Number of 1.57 and a Dynamic Pressure of 9.7 Pounds per Square Foot

A 30-foot (9.1-meter) nominal-diameter cross-type parachute with a cloth area (reference area) of 709 square feet (65.9 square meters) was flight tested in the rocket-launched portion of the NASA Planetary Entry Parachute Program (PEPP). The test parachute was ejected from an instrumented payload by means of a mortar when the system was at a Mach number of 1.57 and a dynamic pressure of 9.7 psf. The parachute deployed to suspension-line stretch in 0.44 second with a resulting snatch-force loading of 1100 pounds (4900 newtons), Canopy inflation began at 0.58 second and a first full inflation was achieved at approximately 0.77 second. The maximum opening load occurred at 0.81 second and was 4255 pounds (18,930 newtons). Thereafter, the test item exhibited a canopy-shape instability in that the four panel arms experienced fluctuations, a "scissoring" type of motion predominating throughout the test period. Calculated values of axial-force coefficient during the deceleration portion of the test varied between 0.35 and 1.05, with an average value of 0.69. During descent, canopy-shape variations had reduced to small amplitudes and resultant pitch-yaw angles of the payload with respect to the local vertical averaged less than 10 degrees. The effective drag coefficient, based on the vertical components of velocity and acceleration during system descent, was 0.78.

TESTS↗