Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Power meter for optical efficiency measurements of laser-induced plasmas

A power meter was constructed to measure the power being deposited in transient laser-induced plasmas (LIP). The design rejects the radiation scattered from the laser beam by the LIP and that transmitted past the LIP. The power meter is constructed from a small metal-capped flask placed in an evacuated chamber. The steady-state heat production in the flask is determined from measurements of the temperature gradient on a thermal resistance connecting the top of the flask with a heat sink. The design worked well and should be applicable to a wide variety of situations if the dimensions of the system are adjusted to compensate for power levels substantially different from those used here.

Borucki, William J.↗

Imaging observations of the evolution of meter-decameter burst emission during a major flare

The results of a study of the evolution of the February 3, 1986 flare at meter-decameter wavelengths are presented, using the two-dimensional imaging observations made with the Clark Lake multifrequency radioheliograph. The flare was complex and produced various types of meter-decameter bursts. The preflare activity was observed in the form of type III bursts some tens of minutes prior to the impulsive onset. From the positional analysis of the preflare and impulsive phase type III bursts and other measured characteristics, the characteristics of energy release and possible magnetic field configurations in the vicinity of the energy release region are discussed. From positional and temporal studies of the flare continuum and type II burst in relation to the microwave and hard X-ray emissions, the possible magnetic field structures in which the accelerated particles are confined or along which they propagate are discussed; a schematic model of the flaring region is developed, based upon this study.

Gopalswamy, N.↗

Automatic Range Changer For SWR Meter

Commercial unit modified for antenna-pattern measurements. Addition of automatic range-changing circuit converts Hewlett-Packard 415E standing-wave-ratio (SWR) meter into radio-frequency detector suitable for computer-controlled measurements of radiation patterns of antennas. Modification gives SWR meter effective dynamic range of at least 40 dB. Includes two digital lines communicating one of four range settings to controlling computer and one digital line to inhibit transfer of data when range being changed. Ideal instrument for use in applications involving computer-controlled monitoring of power when large changes in signal level expected.

Dengler, Robert J.↗

Three-meter balloon-borne telescope

The Three-Meter Balloon-Borne Telescope is planned as a general purpose facility for making far-infrared and submillimeter astronomical observations from the stratosphere. It will operate throughout the spectral range 30 microns to 1 millimeter which is largely obscurred from the ground. The design is an f/13.5 Cassegrain telescope with an f/1.33 3-meter primary mirror supported with a 3-axis gimbal and stabilization system. The overall structure is 8.0 m high by 5.5 m in width by 4.0 m in depth and weighs 2000 kg. This low weight is achieved through the use of an ultra lightweight primary mirror of composite construction. Pointing and stabilization are achieved with television monitoring of the star field, flex-pivot bearing supports, gyroscopes, and magnetically levitated reaction wheels. Two instruments will be carried on each flight; generally a photometric camera and a spectrometer. A 64-element bolometer array photometric camera operating from 30 to 300 microns is planned as part of the facility. Additional instruments will be derived from KAO and other development programs.

Hoffmann, William F.↗

Evaluation of a metering, mixing, and dispensing system for mixing polysulfide adhesive

Tests were performed to evaluate whether a metered mixing system can mix PR-1221 polysulfide adhesive as well as or better than batch-mixed adhesive; also, to evaluate the quality of meter-mixed PR-1860 and PS-875 polysulfide adhesives. These adhesives are candidate replacements for PR-1221 which will not be manufactured in the future. The following material properties were evaluated: peel strength, specific gravity and adhesive components of mixed adhesives, Shore A hardness, tensile adhesion strength, and flow rate. Finally, a visual test called the butterfly test was performed to observe for bubbles and unmixed adhesive. The results of these tests are reported and discussed.

Evans, Kurt B.↗

A conflict analysis of 4D descent strategies in a metered, multiple-arrival route environment

A conflict analysis was performed on multiple arrival traffic at a typical metered airport. The Flow Management Evaluation Model (FMEM) was used to simulate arrival operations using Denver Stapleton's arrival route structure. Sensitivities of conflict performance to three different 4-D descent strategies (clear-idle Mach/Constant AirSpeed (CAS), constant descent angle Mach/CAS and energy optimal) were examined for three traffic mixes represented by those found at Denver Stapleton, John F. Kennedy and typical en route metering (ERM) airports. The Monte Carlo technique was used to generate simulation entry point times. Analysis results indicate that the clean-idle descent strategy offers the best compromise in overall performance. Performance measures primarily include susceptibility to conflict and conflict severity. Fuel usage performance is extrapolated from previous descent strategy studies.

Izumi, K. H.↗

Preliminary design considerations for 10 to 40 meter-diameter precision truss reflectors

A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.

Mikulas, Martin M., Jr.↗

Pattern-recognition techniques applied to performance monitoring of the DSS 13 34-meter antenna control assembly

The results of applying pattern recognition techniques to diagnose fault conditions in the pointing system of one of the Deep Space network's large antennas, the DSS 13 34-meter structure, are discussed. A previous article described an experiment whereby a neural network technique was used to identify fault classes by using data obtained from a simulation model of the Deep Space Network (DSN) 70-meter antenna system. Described here is the extension of these classification techniques to the analysis of real data from the field. The general architecture and philosophy of an autonomous monitoring paradigm is described and classification results are discussed and analyzed in this context. Key features of this approach include a probabilistic time-varying context model, the effective integration of signal processing and system identification techniques with pattern recognition algorithms, and the ability to calibrate the system given limited amounts of training data. Reported here are recognition accuracies in the 97 to 98 percent range for the particular fault classes included in the experiments.

Mellstrom, J. A.↗

A reflection-type oil-film skin-friction meter

Unlike many conventional methods of measuring skin-friction, the oil-film method is absolute in nature, requires no calibration, and, in principle, can be universally applied. In all existing forms of the meter, however, interferometry is used to make measurements of the oil film. Here, the technique has been simplified by completely eliminating interferometry. This has been achieved by making direct and dynamic measurements of the oil-film slope by directing a reflected beam of light off the top of the oil film to a small position sensing photodiode. The reflection method has been verified in incompressible flat plate turbulent boundary-layers. The standard of deviation of the measurements is about 10 percent of the mean. The present version of the meter is compact and simple.

Bandyopadhyay, P. R.↗

Dynamic modeling of the servovalves incorporated in the servo hydraulic system of the 70-meter DSN antennas

As the pointing accuracy and service life requirements of the DSN 70 meter antenna increase, it is necessary to gain a more complete understanding of the servo hydraulic system in order to improve system designs to meet the new requirements. A mathematical model is developed for the servovalve incorporated into the hydraulic system of the 70 meter antenna and uses experimental data to verify the validity of the model and to identify the model parameters.

Bartos, R. D.↗

Active member vibration control for a 4 meter primary reflector support structure

The design and testing of a new low voltage piezoelectric active member with integrated load cell and displacement sensor is described. This active member is intended for micron level vibration and structural shape control of the Precision Segmented Reflector test-bed. The test-bed is an erectable 4 meter diameter backup support truss for a 2.4 meter focal length parabolic reflector. Active damping of the test-bed is then demonstrated using the newly developed active members. The control technique used is referred to as bridge feedback. With this technique the internal sensors are used in a local feedback loop to match the active member's input impedance to the structure's load impedance, which then maximizes vibrational energy dissipation. The active damping effectiveness is then evaluated from closed loop frequency responses.

Umland, J. W.↗

4 X 7 M Modeling Program. The Use of Small-Scale Modeling in Defining Flow Improvements for the Langley 4 X 7-Meter Tunnel

The use of small scale modeling in defining flow improvements for the Langley 4 x 7 meter wind tunnel is presented. Topics covered in viewgraph format include: description of the 4 x 7 meter wind tunnel, description of the 1/24 scale model, wind tunnel circuit flow characteristics, open test section turbulence characteristics, and conclusions.

Applin, Zachery T.↗

Reflection-Type Oil-Film Skin-Friction Meter

Oil-film skin-friction meter for both flight and wind-tunnel applications uses internal reflection and is self-contained, compact unit. Contained in palm-sized housing, in which source of light, mirrors, and sensor mounted rigidly in alignment. Entire unit mounted rigidly under skin of aircraft or wind tunnel, eliminating any relative vibration between optical elements and skin of aircraft or wind tunnel. Meter primarily applicable to flight and wind-tunnel tests, also used in chemical-processing plants.

Bandyopadhyay, Promode R.↗

Ampere-Hour Meter For Rechargeable Battery

Low-power analog/digital electronic circuit meters discharge of storage battery in ampere-hours. By metering discharge, one obtains indication of state of charge of battery and avoids unnecessary recharging, maintaining capacity of battery and prolonging life. Because of its small size and low power consumption, useful in such applications as portable video cameras, communication equipment on boats, portable audio equipment, and portable medical equipment.

Tripp, John S.↗

Two-directional skin friction measurement utilizing a compact internally mounted thin-liquid-film skin friction meter

A new, compact oil film skin friction meter capable of measuring skin friction in two directions has been designed and constructed. The instrument allows the thin liquid film technique to now be applied in flight and in a wider variety of laboratory conditions. The instrument was tested by comparing measurements with those given by a floating element gage in laminar, transitional, and turbulent boundary layers with zero pressure gradient. Both instruments agreed satisfactorily with each other and with the expected curves for the laminar and turbulent boundary layers. Significant differences were at first seen between the oil film meter and two floating element gages in the case of a favorable pressure gradient, but when a correction is applied to account for the normal force acting on the pendulum-type gage, the three instruents are much closer. The directional sensitivity of the oil film gage is also demonstrated.

Seto, Jeffrey A.↗

Thermal emissivity analysis of a GEMINI 8-meter telescopes design

The GEMINI 8-meter Telescopes Project is designing twin 8-meter telescopes to be located in Hawaii and Chile. The GEMINI telescopes will have interchangeable secondary mirrors for use in the visible and IR. The APART/PADE program is being used to evaluate the effective IR emissivity of the IR configuration plus enclosure as a function of mirror contamination at three IR wavelengths. The goal is to design a telescope whose effective IR emissivity is no more than 2 percent when the mirrors are clean.

St. Clair Dinger, Ann↗

Description of the Klemperer wing strain meter (accelerometer)

The wing strain meter enables a pilot to know the strain on lifting surfaces and to warn him of the safe limits which may not be exceeded. In wing strain the most important factors are the force of gravity and the force of lift which gives the measure of the sustaining force, and their components which are perpendicular to the lifting surfaces. This reports methods for using the wing strain meter.

INSTRUMENTS - WING LOAD INDICATORS - KLEMPERER (ZE↗

The Efficiency of the Smoke Meter at Characterizing Engine Emissions

The effectiveness of a smoke meter's ability to characterize the particulate emissions of a jet fuel combustor was evaluated using the University of Missouri-Rolla Mobile Aerosol Sampling System (UMR-MASS). A burner simulating an advanced jet engine combustor design was used to generate typical combustion particulates, which were then analyzed by the smoke meter. The same particulates were then size discriminated to ascertain the effective impact of aerosol diameter on smoke number readings.

Paladino, Jonathan D.↗