Search NASA⌕ Search

SEARCH · Search NASA

Results for “method of cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cost-effective Manufacturing and Morphological Stabilization of Nanostructured Cathodes for Commercial Solid Oxide Fuel Cells (SOFCs) [Slides]

The overall goals of the program were to develop methods for preparing and stabilizing SOFC electrodes by infiltration that can be manufactured on a practical scale, then transfer those methods to cells in stacks. Cathodes prepared by infiltration of nanoparticles into a porous scaffold of the electrolyte have demonstrated outstanding electrochemical performance and mechanical strength but are difficult to manufacture due to the large number of infiltration steps required to produce a conductive composite and show poor stability due to sintering of the nanoparticles. At Penn, the main goal was to develop a fabrication method that uses only a small number of infiltration steps. Infiltration with molten salts and electrodeposition were pursued but deemed impractical. A method in which an electronically conductive scaffold consisted of a composite of a mixed conductor, LSF (La 0.9 Sr 0.1 FeO 3 ), with yttria-stabilized zirconia (YSZ) was found to be promising. While some cation mixing between LSF and YSZ was observed during calcination, there was no evidence for new phases in XRD and incorporation of Zr into the perovskite could be minimized by reducing the Sr content of the LSF. To stabilize nanoparticles infiltrated into the LSF-YSZ composite scaffold, the USC team examined the effects of Atomic Layer Deposition with ZrO 2 and infiltrated nanoparticles. Significantly enhanced stability was observed with the infiltrated nanoparticles. The FuelCell Energy team prepared 4”x4” cells in which an LSF-YSZ composite scaffold was cofired with the YSZ electrolyte and infiltrated with LSCF nanoparticles. Apparently because the LSF-YSZ scaffold layer was very thin in this case, the cation mixing that occurred during calcination resulted in a poor scaffold-electrolyte interface which caused reduced performance.

30 DIRECT ENERGY CONVERSION↗

Nonlinear global gyrokinetic delta- f turbulence simulations in a quasi-axisymmetric stellarator

We use the global gyrokinetic stellarator code XGC-S to look at turbulence physics in geometry of the proposed quasi-axisymmetric stellarator, QUASAR. In this article, the XGC-S code is first verified for nonlinear simulations of ion temperature gradient-driven turbulence by a successful benchmark with the established nonlinear tokamak code XGC1 in a CYCLONE-like tokamak case. We then apply the XGC-S code to QUASAR for nonlinear turbulence physics. We find that the highly poloidally localized linear mode gives way to a more evenly distributed nonlinear turbulent structure. Furthermore, the radial extent of the mode increases and occupies a large fraction of the volume, despite the initially localized temperature profile, as the profiles relax.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic simulations comparing quasi-parallel and quasi-perpendicular piston-driven collisionless shock dynamics in magnetized laboratory plasmas

Magnetized collisionless shocks are common in astrophysical systems, and scaled versions can be created in laboratory experiments by utilizing laser-driven piston plasmas to create these shocks in a magnetized background plasma. A key parameter for these experiments is the angle θB between the shock propagation direction and the background magnetic field. We performed quasi-1D piston-driven shock simulations to explore shock formation, evolution, and key observables relevant to laboratory experiments for a range of shock angles between θB=90° to θB=30°. Our results show that the spatial and temporal scales of shock formation for all angles considered are similar when expressed in terms of the perpendicular component of the magnetic field. In a steady state, ion and electron temperatures become more isotropic, and the electron-to-ion temperature ratio is higher for smaller θB. At θB=30°, ion heating parallel to the magnetic field becomes dominant, associated with more ions being reflected at one discontinuity and subsequently trapped by the next discontinuity due to shock reformation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Regulation of Alfvén Eigenmodes by Microturbulence in Fusion Plasmas

Global gyrokinetic simulations of mesoscale reversed shear Alfven eigenmodes (RSAE) excited by energetic particles (EP) in fusion plasmas find that RSAE amplitude and EP transport are much higher than experimental levels at nonlinear saturation, but quickly diminish to very low levels after the saturation when background microturbulence is artificially suppressed. In contrast, in simulations coupling micro-meso scales, the RSAE amplitude and EP transport decrease drastically at the initial saturation but later increases to the experimental levels in the quasi-steady state with bursty dynamics due to regulation by thermal ion temperature gradient (ITG) microturbulence. The quasi-steady state EP transport is larger for a stronger microturbulence. Here, the RSAE amplitude in the quasi-steady state ITG-RSAE turbulence from gyrokinetic simulations, for the first time, agrees very well with experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

Christophersen, Jon P.↗

Control of power converters having integrated capacitor blocked transistor cells

Various examples of power converters including Integrated Capacitor Blocked Transistor (ICBT) cells and methods of control of power converters having ICBT cells are described. In one example, a power converter includes an upper arm including a plurality of upper ICBT cells connected in series to form a series connection path and a lower arm including a plurality of lower ICBT cells connected in series in the series connection path. A controller can be configured to provide a control signal pair to each of the upper ICBT cells and a complementary control signal pair to each of the lower ICBT cells to control the converter output. A capacitor voltage controller can be configured to balance a voltage potential among ICBT capacitors in at least one of the upper arm and the lower arm.

Yu, Jianghui↗

Self-healing electrode protection in electrochemical cells

Articles and methods for protection of electrodes in electrochemical cells, including protective material precursor layers for use in electrode protective structures, are provided. Certain embodiments relate to electrode protective structures that comprise protective material precursor layers that, upon direct contact with a liquid electrolyte, cause a reaction product to form between the material of the precursor layer and a component of the electrolyte.

36 MATERIALS SCIENCE↗

On the Road to Regeneration: “Tools” and “Routes” Towards Efficient Cardiac Cell Therapy for Ischemic Cardiomyopathy

Purpose of Review: Cardiac regenerative medicine is a field bridging together biotechnology and surgical science. In this review, we present the explored surgical roads to cell delivery and the known effects of each delivery method on cell therapy efficiency. We also list the more recent clinical trials, exploring the safety and efficacy of delivery routes used for cardiac cell therapy approaches. Recent Findings: There is no consensus in defining which way is the most suitable for the delivery of the different therapeutic cell types to the damaged heart tissue. In addition, it emerged that the “delivery issue” has not been systematically addressed in each clinical trial and for each and every cell type capable of cardiac repair. Summary: Cardiac damage occurring after an ischemic insult triggers a cascade of cellular events, eventually leading to heart failure through fibrosis and maladaptive remodelling. None of the pharmacological or medical interventions approved so far can rescue or reverse this phenomenon, and cardiovascular diseases are still the leading cause of death in the western world. Therefore, for nearly 20 years, regenerative medicine approaches have focused on cell therapy as a promising road to pursue, with numerous preclinical and clinical testing of cell-based therapies being studied and developed. Nonetheless, consistent clinical results are still missing to reach consensus on the most effective strategy for ischemic cardiomyopathy, based on patient selection, diagnosis and stage of the disease, therapeutic cell type, and delivery route.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid native single cell mass spectrometry

A method for analyzing single cells by mass spectrometry includes the steps of providing a plurality of cells in a liquid medium and placing the cells and liquid medium in a single cell isolation and ejection system. Liquid medium containing a single cell is released from the single cell isolation and ejection system. The liquid medium and single cell are captured in a capture probe containing a flowing capture probe solvent. The cell is lysed by a lysis inducer in the capture probe to disperse single cell components into the medium. The lysed single cell components are transported to a mass spectrometer, where the lysed single cell components entering the mass spectrometer are spatially and temporally separated from any dispersed components of another single cell from the sample entering the mass spectrometer. Mass spectrometry is conducted on the lysed single-cell components. A system for analyzing single cells by mass spectrometry is also disclosed.

Cahill, John F.↗

Rapid native single cell mass spectrometry

A method for analyzing single cells by mass spectrometry includes the steps of providing a plurality of cells in a liquid medium and placing the cells and liquid medium in a single cell isolation and ejection system. Liquid medium containing a single cell is released from the single cell isolation and ejection system. The liquid medium and single cell are captured in a capture probe containing a flowing capture probe solvent. The cell is lysed by a lysis inducer in the capture probe to disperse single cell components into the medium. The lysed single cell components are transported to a mass spectrometer, where the lysed single cell components entering the mass spectrometer are spatially and temporally separated from any dispersed components of another single cell from the sample entering the mass spectrometer. Mass spectrometry is conducted on the lysed single-cell components. A system for analyzing single cells by mass spectrometry is also disclosed.

Cahill, John F.↗

Methods for producing and using perovskite materials and devices therefrom

The present disclosure describes solution methods for manufacturing perovskite halide films for use in solar cells. The methods include the use of additives that facilitate the formation of transitory, intermediate films that are later transformed into the final target perovskite halide films, such that the final films provide improved physical characteristics and operational performance.

14 SOLAR ENERGY↗

Methods for producing and using perovskite materials and devices therefrom

The present disclosure describes solution methods for manufacturing perovskite halide films for use in solar cells. The methods include the use of additives that facilitate the formation of transitory, intermediate films that are later transformed into the final target perovskite halide films, such that the final films provide improved physical characteristics and operational performance.

Zhu, Kai↗

Method and apparatus of fabricating a solar cell device

Solar cell devices as well as method and apparatus for producing solar cell devices are disclosed. Aspects of the disclosure provide a solar cell device that includes a string of solar cells. The string of solar cells are conductively connected in series and arranged in a shingled manner with sides of adjacent solar cells being overlapped. A first metal ribbon segment is conductively bonded to a front surface of an end cell, the front surface being configured to face a light incoming direction to receive energy from a light source.

Caswell, Nathaniel Alexis↗

Method and apparatus of fabricating a solar cell device

Solar cell devices as well as method and apparatus for producing solar cell devices are disclosed. Aspects of the disclosure provide a solar cell device that includes a string of solar cells. The string of solar cells are conductively connected in series and arranged in a shingled manner with sides of adjacent solar cells being overlapped. A first metal ribbon segment is conductively bonded to a front surface of an end cell, the front surface being configured to face a light incoming direction to receive energy from a light source.

Caswell, Nathaniel↗

Engineered microcompartment protein and related methods and systems of engineering bacterial systems for non-native protein expression and purification

Engineered microcompartment proteins, and related engineered microcompartment, vectors, cells compositions, methods and systems configured to provide within a cell one or more proteins non-native to the cell are described, wherein the one or more proteins non-native to the cell are contained in at least one engineered microcompartment within the cell.

59 BASIC BIOLOGICAL SCIENCES↗