The Ductility of 49Fe-49Co-2V Soft Magnetic Alloy Bar: Surface Effects and Test Methods

The tensile ductility of 49Fe-49Co-2V (Hiperco® 50A) bar was investigated in both as-received and heat-treated conditions. The as-received/machined specimens exhibit very low ductility compared to samples where heat treatment was the final step prior to testing. Microstructural characterization showed that internal residual strain from bar processing and, most importantly, surface machining damage, cause lower elongation in the as-received material. Because fracture of this intermetallic alloy initiates at the surface, it is particularly susceptible to surface machining damage, i.e., the near-surface region has already exhausted most of its ability to accumulate tensile strain. During heat treatment, the internal residual strain and near-surface machining damage are eliminated and ductility is improved, despite a higher degree of crystallographic ordering in the heat-treated condition (which typically lowers ductility). Furthermore, if machining is again performed after heat treatment, the material again exhibits brittle behavior, even with only light touch-up machining passes. Here, in this work, methods of tensile strain measurement were investigated, namely conventional knife-edge extensometry and noncontact digital image correlation (DIC) on heat-treated material. For clip-on knife-edge extensometry, the range of failure strain was 2.5-5.5% for heat-treated Hiperco. For noncontact methods, ductility up to 7% was observed. The results highlight the tendency for the alloy to fail at surface imperfections, even those produced by application of the extensometer itself. Noncontact laser extensometry is recommended for determining the intrinsic ductility of the alloy. A method of laser surface modification was developed which increased ductility by ~ 100% compared to unmodified samples. The high cooling rates achieved during laser surface processing can bypass the ordering reaction and produce a ductile disordered structure at the surface that exhibits ductile fracture characteristics.

EBSD↗

Structure preserving transport stabilized compatible finite element methods for magnetohydrodynamics

Here, we present compatible finite element space discretizations for the ideal compressible magnetohydrodynamic equations. The magnetic field is considered both in div- and curl-conforming spaces, leading to a strongly or weakly preserved zero-divergence condition, respectively. The equations are discretized in space such that transfers between the kinetic, internal, and magnetic energies are consistent, leading to a preserved total energy. We also discuss further adjustments to the discretization required to additionally achieve magnetic helicity preservation. Finally, we describe new transport stabilization methods for the magnetic field equation which maintain the zero-divergence and energy conservation properties, including one method which also preserves magnetic helicity. The methods' preservation and improved stability properties are confirmed numerically using a steady state and a magnetic dynamo test case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tailoring magnetization reversal of a single-domain bar nanomagnet via its end geometry

Nanoscale single-domain bar magnets are building blocks for a variety of fundamental and applied mesoscopic magnetic systems, such as artificial spin ices, magnetic shape-morphing microbots, and magnetic majority logic gates. The magnetization reversal switching field of the bar nanomagnets is a crucial parameter that determines the physical properties and functionalities of their constituted artificial systems. Previous methods on tuning the magnetization reversal switching field of a bar nanomagnet usually relied on modifying its aspect ratio, such as its length, width, and/or thickness. Here, we show that the switching field of a bar nanomagnet saturates when extending its length beyond a certain value, preventing further tailoring of the magnetization reversal via aspect ratios. We showcase a highly tunable switching field of a bar nanomagnet by tailoring its end geometry without altering its size. This provides an easy method to control the magnetization reversal of a single-domain bar nanomagnet. It would enable new research and/or applications, such as designing artificial spin ices with additional tuning parameters, engineering magnetic microbots with more flexibility, and developing magnetic quantum-dot cellular automata systems for low power computing.

36 MATERIALS SCIENCE↗

Study of Self-Interaction Errors in Density Functional Calculations of Magnetic Exchange Coupling Constants Using Three Self-Interaction Correction Methods

We examine the role of self-interaction errors (SIE) removal on the evaluation of magnetic exchange coupling constants. In particular we analyze the effect of scaling down the self-interaction-correction (SIC) for three non-empirical density functional approximations (DFAs) namely, the local spin density approximation, the Perdew-Burke-Ernzerhof generalized gradient approximation, and recent SCAN family of meta-GGA functionals. To this end, we employ three one-electron SIC methods: Perdew-Zunger [Perdew, J. P.; Zunger, A. Phys. Rev. B, 1981, 23, 5048] SIC, the orbitalwise scaled SIC method [Vydrov, O. A. et al., J. Chem. Phys. 2006, 124, 094108], and the recent local scaling method [Zope, R. R. et al., J. Chem. Phys. 2019, 151, 214108]. We compute the magnetic exchange coupling constants using the spin projection and non projection approaches for sets of molecules composed of dinuclear and polynuclear H-He models, organic radical molecules, and chlorocuprate, and compare these results against accurate theories and experiment. Our results show that for the systems that mainly consist of single electron regions, PZSIC performs well but for more complex organic systems and the chlorcuprates, an overcorrecting tendency of PZSIC combined with the DFAs utilized in this work is more pronounced, and in such cases LSIC with kinetic energy density ratio performs better than PZSIC. Furthermore, analysis of the results in terms of SIC corrections to the density and to the total energy shows that both density and energy correction are required to obtain an improved prediction of magnetic exchange couplings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local and long-range atomic/magnetic structure of non-stoichiometric spinel iron oxide nanocrystallites

Spinel iron oxide nanoparticles of different mean sizes in the range 10–25 nm have been prepared by surfactant-free up-scalable near- and super-critical hydrothermal synthesis pathways and characterized using a wide range of advanced structural characterization methods to provide a highly detailed structural description. The atomic structure is examined by combined Rietveld analysis of synchrotron powder X-ray diffraction (PXRD) data and time-of-flight neutron powder-diffraction (NPD) data. The local atomic ordering is further analysed by pair distribution function (PDF) analysis of both X-ray and neutron total-scattering data. It is observed that a non-stoichiometric structural model based on a tetragonal γ-Fe 2 O 3 phase with vacancy ordering in the structure (space group P 4 3 2 1 2) yields the best fit to the PXRD and total-scattering data. Detailed peak-profile analysis reveals a shorter coherence length for the superstructure, which may be attributed to the vacancy-ordered domains being smaller than the size of the crystallites and/or the presence of anti-phase boundaries, faulting or other disorder effects. The intermediate stoichiometry between that of γ-Fe 2 O 3 and Fe 3 O 4 is confirmed by refinement of the Fe/O stoichiometry in the scattering data and quantitative analysis of Mössbauer spectra. The structural characterization is complemented by nano/micro-structural analysis using transmission electron microscopy (TEM), elemental mapping using scanning TEM, energy-dispersive X-ray spectroscopy and the measurement of macroscopic magnetic properties using vibrating sample magnetometry. Notably, no evidence is found of a Fe 3 O 4 /γ-Fe 2 O 3 core-shell nanostructure being present, which had previously been suggested for non-stoichiometric spinel iron oxide nanoparticles. Finally, the study is concluded using the magnetic PDF (mPDF) method to model the neutron total-scattering data and determine the local magnetic ordering and magnetic domain sizes in the iron oxide nanoparticles. The mPDF data analysis reveals ferrimagnetic collinear ordering of the spins in the structure and the magnetic domain sizes to be ∼60–70% of the total nanoparticle sizes. The present study is the first in which mPDF analysis has been applied to magnetic nanoparticles, establishing a successful precedent for future studies of magnetic nanoparticles using this technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-Field EMR Studies of Permalloy Films and Gratings

Flat and profile-modulated permalloy films have been studied by the electron magnetic resonance (EMR) method. In addition to ferromagnetic and spin-wave resonances, the structures demonstrate low-field EMR signals of an unusual shape, which form a hysteresis loop in sweeping fields. The low-field signals are attributed to a fast reorientation of magnetic domains. The low-field EMR behavior is comparable to the behavior in magneto-dependent photovoltage previously observed in the optical experiments. The shapes of the loops and typical values of the switching fields depend on the profile modulation parameters confirming the possibility of controlling magnetic properties and the coupling of magnetic and optical effects with nanoscale geometry.

36 MATERIALS SCIENCE↗

Aberration corrected RF flipper for high resolution neutron spectroscopy

Project Summary Company: Adelphi Technology, Inc. Title: Aberration-corrected High Frequency RF Flipper for High-Resolution Neutron Spectroscopy PI: Dr. Jay Theodore Cremer Topic: C55-11 Enhancement of Scattering Instrumentation Technology Used at Pulsed and Continuous Sources Subtopic: d. Other Statement of the problem or situation that is being addressed. The quest to understand heterogeneous and hierarchical materials is gathering momentum, as described in a 2015 report by the Basic Energy Sciences Advisory Committee on Challenges at the Frontiers of Matter and Energy. For the past 40 years a technique called neutron spin echo (NSE) has been used to probe molecular motions in such non-crystalline materials over time scales from 10’s of picoseconds to 100’s of nanoseconds. The method has provided unique information about the dynamics of soft heterogeneous materials, including confirmation of the de Gennes model of polymer reptation and quantitative measurement of bending constants of biologically relevant lipid membranes. However, scientists continue to clamor for even higher resolution than NSE can provide. Biomaterials, polymers, glasses, and artificially nanostructured materials all manifest slow molecular motions because of weak or competing interactions between subunits and are amenable to study with neutrons, provided sufficiently long dynamical correlation times can be achieved. All these materials have important applications to advanced technologies so understanding them is key to technological progress. General statement of how this problem is being addressed. We will address the need for high-resolution neutron spectroscopy by using a technique called Neutron Resonance Spin Echo (NRSE). While similar to NSE in many respects, this method has the potential to exceed the NSE capabilities, if 2 technical hurdles can be overcome. The major impediments to successful high-resolution NRSE are the availability of two technologies: a very high frequency, efficient, radiofrequency (rf) flipper for neutrons and a method to correct certain magnetic aberrations. Based on previous STTR support and follow-on research we have developed a suitable rf flipper and we have invented a method to correct the magnetic aberrations. Both technologies need refinement to make them suitable for implementation at a neutron source such as the Oak Ridge National Laboratory nuclear reactor. In this proposal we seek to perfect the two technologies and to combine them into a single, operationally convenient device. Commercial Applications and Other Benefits In view of the increasing demand for the unique scientific information that high resolution neutron spectroscopy can provide, we expect several major instrumentation upgrades at both U.S. and foreign neutron centers will require make use of the NRSE method over the coming decade, creating a market for the devices we will design. These components will enhance scientists’ abilities to probe the time dependence of density fluctuations in a wide range of hierarchical and heterogeneous materials many of which are vital to existing and future technologies. Key Words – Polarized Neutrons, Neutron Spin Echo, Neutron Scattering, advanced materials. Summary for Members of Congress Neutron beams are a powerful materials-science probe that provide unique information about the structure of matter. The proposed devices will accelerate scientific discoveries required to achieve national goals for new technological materials.

36 MATERIALS SCIENCE↗

High‐Throughput Screening Assisted Discovery of a Stable Layered Anti‐Ferromagnetic Semiconductor: CdFeP 2 Se 6

Recent advances in 2D magnetism have heightened interest in layered magnetic materials due to their potential for spintronics. In particular, layered semiconducting antiferromagnets exhibit intriguing low-dimensional semiconducting behavior with both charge and spin as carrier controls. However, synthesis of these compounds is challenging and remains rare. Here, first-principles based high-throughput search is conducted to screen potentially stable mixed metal phosphorous trichalcogenides (MM ' P 2 X 6 , where M and M ' are transition metals and X is a chalcogenide) that have a wide range of tunable bandgaps and interesting magnetic properties. Among the potential candidates, a stable semiconducting layered magnetic material, CdFeP 2 Se 6 , that exhibits a short-range antiferromagnetic order at T N = 21 K with an indirect bandgap of 2.23 eV is successfully synthesized . This work suggests that high-throughput screening assisted synthesis can be an effective method for layered magnetic materials discovery.

2D materials↗

Study of solid molecular deuterium D 2 growth under gas pressure

The injection of high-speed cryogenic pellets made of frozen hydrogen-isotopes, represents to date the most effective method to fuel magnetically confined thermonuclear fusion plasmas. Additionally, the injection of very large pellets composed of cryogenic solid of some suitable impurity (typically a noble-gas such as H 2 , Ne, or H 2 /Ne, D 2 /Ne mixtures), shattered in relatively small fragments just before entering the plasma, seems to be the most promising method to reduce the damage risks for the plasma-facing components in case of a plasma disruption. This technology, known as "Shattered Pellet Injection" (SPI), allows to spread out the plasma energy and mitigate possible damage to the in-vessel components, as well as to densify the plasma to suppress the formation of runaway electrons, and/or dissipate their energy. Several techniques to produce and launch cryogenic pellets have been investigated in the past decades. "Pipe gun" injectors are reliable and relatively simple devices are still commonly used today. They make use of single- or two-stage pneumatic light-gas guns to accelerate the pellet at high speeds. In these injectors, the cryogenic pellets are formed “ in situ ” (i.e., inside the launching barrel), by de-sublimating them directly from the gas phase, i.e., at temperatures and pressures below those of the triple point. The simplest case is pure deuterium pellets ($\mathcal{T}$ < 18.7 K, $\mathcal{P}$ < 171.3 hPa). The production of good quality solid deuterium, capable of withstanding the mechanical stress during the acceleration of the pellets, is a key issue. To this end the phase transition of deuterium from gas to solid (and vice versa) is modeled with extensive molecular-dynamics (MD) simulations. Furthermore, the solid growth from the gas phase is simulated in an ample range of temperatures and pressures, to find the best compromise between growth velocity and mechanical properties of the resulting solid system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modulating above-room-temperature magnetism in Ga-implanted Fe 5 GeTe 2 van der Waals magnets

The creation of van der Waals (vdW) ferromagnets with tunable Curie temperature (T C ) and magnetic anisotropy is essential in developing vdW magnet-based devices. Here, we report an effective and reliable method for modulating the magnetic properties of vdW Fe 5 GeTe 2 by site-specific Ga + implantation. In this study, we report an easy axis in the ab-plane for bulk Fe 5 GeTe 2 (T C = 310 K) and an axis out of the plane for thin Fe 5 GeTe 2 flakes (T C = 290 K). Combining element-resolved photoemission electron microscopy and spatially resolved magneto-optic Kerr microscopy, we find that the implantation of a tiny amount of 10 –3 Ga + ·Å –3 in Fe 5 GeTe 2 greatly enhances the T C from 290 to 360 K and switches the magnetic easy axis from the out-of-plane c axis to the ab-plane. The room-temperature x-ray magnetic circular dichroism signal is enhanced from 0% to 9% at an implantation level of 10 –2 Ga + ·Å –3 . These results provide new opportunities for tailoring the magnetic properties of vdW materials beyond room temperature.

36 MATERIALS SCIENCE↗

Generation of strong fields with subcritical density plasmas to study the phase transitions of magnetized warm dense matter

Warm dense matter (WDM) is a regime where Fermi degenerate electrons play an important role in the macroscopic properties of a material. Recent experiments have brought us closer to understanding unmagnetized processes in WDM, but magnetized WDM remains unexplored because kilotesla magnetic fields are required. Although there are examples of field compression generating such fields by imploding pre-magnetized targets, these existing methods give no independent control over the parameters of the magnetized plasma and result in limited laser access for sample creation and diagnosis. In this paper, numerical simulations show that kilotesla magnetic fields can be obtained by shining laser beams onto the inner surface of a cylindrical target, rather than on the outer surface. This approach relies on field compression by a low-density, high-temperature plasma, rather than a high-density, low-temperature plasma, used in the more conventional approach. With this novel configuration, the region of peak magnetic field is mostly free of plasma, hence, other beams can reach a sample placed in the region of the peak field to form WDM and diagnose it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High efficiency radio frequency antennas for amplifier free quantum sensing applications

Radio frequency (RF) signals are frequently used in emerging quantum applications due to their spin state manipulation capability. Efficient coupling of RF signals into a particular quantum system requires the utilization of carefully designed and fabricated antennas. Nitrogen vacancy (NV) defects in diamond are commonly utilized platforms in quantum sensing experiments with the optically detected magnetic resonance (ODMR) method, where an RF antenna is an essential element. We report on the design and fabrication of high efficiency coplanar RF antennas for quantum sensing applications. Single and double ring coplanar RF antennas were designed with -37 dB experimental return loss at 2.87 GHz, the zero-field splitting frequency of the negatively charged NV defect in diamond. The efficiency of both antennas was demonstrated in magnetic field sensing experiments with NV color centers in diamond. In conclusion, an RF amplifier was not needed, and the 0 dB output of a standard RF signal generator was adequate to run the ODMR experiments due to the high efficiency of the RF antennas.

47 OTHER INSTRUMENTATION↗

A new approach to study adsorption on shales and other microporous solids via the thermogravimetric analysis (TGA) technique

Measuring the adsorption of gases in microporous solids like the shales requires accurate knowledge of the solid’s skeletal volume. Helium (He) is commonly used to determine the sample’s skeletal volume based on the assumption that it does not adsorb in these porous media. The validity of such an assumption for microporous solids has been questioned in recent years, and in this study, we show that it is not applicable for the shale sample studied. We present a new method to measure the adsorption of shale-gas components in shales, which does not require the use of He to measure the solid’s skeletal volume. Since the proposed analysis method relies on the use of dynamic adsorption data, we also propose here a new zero-point correction method for the magnetic suspension balance, which is better suited for the analysis of such data. Here, we employ the new technique to the study of Argon adsorption in Marcellus Shales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stereolithography additive manufacturing of magnetically aligned liquid crystal elastomers

A method of forming a three-dimensional structure includes forming a layer of resin comprising liquid crystal oligomers and a photoinitiator, applying a magnetic field to the formed layer in a predefined alignment direction for substantially aligning the liquid crystal oligomers in a first orientation; and exposing the formed layer to radiation for curing a first portion of the layer during application of the magnetic field thereby resulting in the first portion having liquid crystal elastomers substantially aligned in the first orientation. The method includes applying a second magnetic field to the formed layer in a predefined second alignment direction for substantially aligning uncured liquid crystal oligomers in a second orientation, and exposing the layer to radiation for curing a second portion of the layer during application of the second magnetic field thereby resulting in the second portion having liquid crystal elastomers substantially aligned in the second orientation.

Arriaga, Rodrigo Telles↗

Magnetometer based on spin wave interferometer

A magnetic field detector and associated methods are shown. One example of a magnetic field detector uses spin wave interference to detect information about an external magnetic field.

Khitun, Alexander↗