Development of a Precise Additively Manufactured Mechanical Assembly for Commercial Production of Lamina-Based Micro-channel Plate Detectors
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
High repetition rate laser systems enable new strategies for diagnosing plasma behavior with large datasets. Here, we define an ensemble technique that relies on randomized targeting of x-ray tracer micro-stripes. On each shot, a high-intensity laser pulse is focused on a solid target with Ti tracer stripes embedded in an Al foil, randomly targeting a micro-stripe, a portion of a stripe, or a gap between stripes. High-resolution, time-integrated x-ray spectrometers capture line emission from the portion of the micro-stripe that is heated to sufficiently high electron temperatures. Accumulation of many such cases is used to construct ensemble distributions of x-ray line intensities that encompass all relative offsets of the laser focus to the micro-stripe centers. Synthetic intensity distributions are likewise generated using collisional-radiative modeling. Bayesian fitting of modeled to measured intensity distributions establishes the most likely radial temperature profiles, enabling comparison to hydrodynamic models and calling into question the cylindrical symmetry of these micro-stripe-embedded systems. Ensemble techniques have significant potential for high-energy-density plasma diagnostics, especially with the advent of high repetition rate experiments.
The automated vehicle (AV) equipped with the Adaptive Cruise Control (ACC) system is expected to reduce the fuel consumption for the intelligent transportation system. This paper presents the Advanced ACC-Micro (AA-Micro) model, a new energy consumption model based on micro trajectory data, calibrated and verified by empirical data. Utilizing a commercial AV equipped with the ACC system as the test platform, experiments were conducted at the Columbus 151 Speedway, capturing data from multiple ACC and Human-Driven (HV) test runs. The calibrated AA-Micro model integrates features from traditional energy consumption models and demonstrates superior goodness of fit, achieving an impressive 90% accuracy in predicting ACC system energy consumption without overfitting. A comprehensive statistical evaluation of the AA-Micro model's applicability and adaptability in predicting energy consumption and vehicle trajectories indicated strong model consistency and reliability for ACC vehicles, evidenced by minimal variance in RMSE values and uniform RSS distributions. Conversely, significant discrepancies were observed when applying the model to HV data, underscoring the necessity for specialized models to accurately predict energy consumption for HV and ACC systems, potentially due to their distinct energy consumption characteristics.
Microcrystal electron diffraction (MicroED) is an emerging structural technique in which submicron crystals are used to generate diffraction data for structural studies. Structures allow for the study of molecular-level architecture and drive hypotheses about modes of action, mechanisms, dynamics, and interactions with other molecules. Combining cryoelectron microscopy (cryo-EM) instrumentation with crystallographic techniques, MicroED has led to three-dimensional structural models of small molecules, peptides, and proteins and has generated tremendous interest due to its ability to use vanishingly small crystals. In this perspective, we describe the current state of the field for MicroED methodologies, including making and detecting crystals of the appropriate size for the technique, as well as ways to best handle and characterize these crystals. Our perspective provides insight into ways to unlock the full range of potential for MicroED to access previously intractable samples and describes areas of future development.
Abstract Several classes of materials are being proposed for use in fusion reactors including oxide dispersion strengthened (ODS) and reduced activation ferritic-martensitic (RAF/M) steels to withstand the severe and harsh conditions. In this work, the mechanical properties of a Fe-16Cr-4Al-2W-0.3Ti-0.3Y 2 O 3 (K3) (ODS) ferritic steel and a Fe-8.9Cr-1.1W-0.47Mn-0.2V-0.14Ta-0.11C (Eurofer 97) (RAF/M) steel) after triple ion beam irradiation were locally evaluated utilizing in-situ micro-pillar compression tests, and continuous stiffness/quasi-static nanoindentation. No change in mechanical properties was observed in the K3 ODS steel. However, the Eurofer 97 RAF/M steel exhibited radiation-induced effects via increases in yield strength. Micro-pillar techniques were expanded to neutron-irradiated materials via an in-situ testing technique employing lift-out methods on Fe-14Cr-0.9Ti-0.3Mo-0.25Y 2 O 3 (MA957) ODS ferritic steel. Both the non-irradiated and irradiated compressive yield stresses of the MA 957 micro-pillars were in good agreement with bulk yield stress values reported in the literature, suggesting that the lift-out micro-pillar compression testing technique is a promising method. The demonstration of these techniques on ion beam and neutron irradiated ODS steels and ion beam RAF/M steels gives information to inform models of the material degradation during use in a fusion device.
Micro-scaled high-temperature gas-cooled reactors (micro-HTGRs) offer a promising option for reliable power in remote or off-grid locations. While the safety characteristics of modular HTGRs have been widely studied, a micro-HTGR configuration alters several key thermal-fluid phenomena that govern both normal operation and passive decay-heat removal. In many proposed concepts, the reactor vessel is oriented horizontally and integrated into an ISO shipping container to enhance transportability and modular deployment. This report documents a Phenomena Identification and Ranking Table (PIRT) exercise focused on the thermal hydraulic safety phenomena relevant to all micro-HTGRs. The objective is to systematically identify, describe, and rank the importance, uncertainty, and modeling complexity of the key phenomena that control core and vessel temperatures during normal operation, pressurized conduction cooldown (PCC), and depressurized conduction cooldown (with air ingress) conditions.
The Pierre Auger Observatory (Auger) and the Telescope Array (TA) are the world's two largest ultra-high-energy cosmic ray (UHECR) observatories. They operate in the Southern and Northern hemispheres, respectively, at similar latitudes but with distinct surface detector (SD) designs. A significant challenge in studying UHECR physics across the full sky is the apparent discrepancy in flux measurements between the two experiments. This discrepancy could arise from astrophysical differences and/or systematic effects related to their detector designs and sensitivities to extensive air shower components. To address this, the Auger@TA working group aims to cross-calibrate the two observatories with a self-triggering micro-Auger array within the TA array. This micro-array consists of eight Auger Surface Detector (SD) stations equipped with Water Cherenkov Detectors (WCDs) and AugerPrime Surface Scintillator Detectors. Seven SD stations, configured with a centered-1-PMT design, are arranged in a hexagonal pattern with one station in the center, with 1.5 km spacing, mirroring the Auger layout. The eighth station, which features a standard 3-PMT Auger station, is located in conjunction with a TA detector at the center of the hexagon, forming a triplet for high-statistics and low-uncertainty cross-calibration. A custom communication system that uses readily available components enables seamless communication between stations and remote access to each station through a central computer. The micro-array is now fully deployed, and initial data-taking is about to start. This presentation will detail the instrumentation, communication systems, central data acquisition system, expected performance of the micro-array, and preliminary results as appropriate.
Magnesium (Mg) alloys are ideal candidates for automotive applications due to their high strength to weight ratio, castability, recyclability etc., however, they lack corrosion and oxidation resistance. Solid-state deposition techniques, such as cold spray, have been demonstrated to enhance their corrosion resistance as it relies on the severe plastic deformation of powder particles upon impact with the substrate to form a metallurgical bond with the substrate and within the coating. At cold sprayed interfaces, a heterogeneous microstructure is formed that includes some porosity, oxides and intermetallics which can significantly affect coating performance. Thus, establishing a direct correlation between the interface microstructure and its properties can aid in designing optimal cold spray parameters. In this study, we investigated the microstructure and mechanical properties of a zinc (Zn) coating deposited on a high pressure die cast (HPDC) AZ91 Mg substrate via high resolution scanning transmission electron microscopy, in situ micro-tensile testing, and finite element method (FEM) modeling. Micro-tensile pillars fabricated using the plasma focused ion beam (PFIB) successfully isolates the coating-substrate interface within the gauge length. The average bond strength of Zn-Mg interface was determined to be ∼140 MPa with failure occurring partially at the interface and mostly into the coatings. A detailed microstructural characterization revealed evidence of a strong metallurgical bonding at the Zn-Mg interface and formation of the C14 MgZn 2 laves phase interlayer resulting in a mixed mode of fracture during the micro-tensile experiments. FEM modeling reveals the stress distribution along the interfaces and suggests that a MgZn 2 layer thickness between 200–400 nm is optimum to increase the bond strength and minimize the triaxiality. Such a site-specific interfacial analysis with correlative computational modeling provides crucial insight into the overall performance of cold spray interfaces.
2D materials exhibiting in‐plane anisotropy enable new applications in directional energy transport and polarized optical response. Silver phenylchalcogenides (AgEPh) – including mithrene (AgSePh), tethrene (AgTePh), and thiorene (AgSPh) – represent an exciting new addition to this family, with optical response spanning the visible to near‐UV. Here, excitonic anisotropy is predicted and characterized in this family of materials using a combination of ab initio theory and optical micro‐spectroscopy of single‐crystalline flakes. Using density functional theory and GW with the Bethe–Salpeter equation calculations, it is revealed that all AgEPh compounds exhibit anisotropic electronic band structure and host multiple delocalized excitons with in‐plane anisotropy. Room‐temperature polarization‐resolved optical micro‐spectroscopy shows that orthogonally polarized excitons with similar energy lead to nearly isotropic absorption in AgSPh, whereas energy separation between excitonic resonances in AgSePh and AgTePh leads to strong absorption and emission anisotropy. Cryogenic reflectance micro‐spectroscopy further reveals exciton fine structure in AgSePh, reconciling the discrepancies between room‐temperature experiments and theoretical predictions. Finally, it is demonstrated that the optical response of thicker AgEPh crystals is influenced by photonic effects arising from finite crystal size. Overall, this work advances the understanding of the relationship between anisotropic structure, composition, and excitonic properties in AgEPh, providing a foundation for technological integration.
Addressing sustainable energy storage remains crucial for transitioning to renewable sources. While Li‐ion batteries have made significant contributions, enhancing their capacity through alternative materials remains a key challenge. Micro‐sized silicon is a promising anode material due to its tenfold higher theoretical capacity compared to conventional graphite. However, its substantial volumetric expansion during cycling impedes practical application due to mechanical failure and rapid capacity fading. A novel approach is proposed to mitigate this issue by incorporating trace amounts of aluminum into the micro‐sized silicon electrode using ball milling. Density functional theory (DFT) is employed to establish a theoretical framework elucidating how grain boundary sliding, a key mechanism involved in preventing mechanical failure is facilitated by the presence of trace aluminum at grain boundaries. This, in turn, reduces stress accumulation within the material, reducing the likelihood of failure. To validate the theoretical predictions, capacity retention experiments are conducted on undoped and Al‐doped micro‐sized silicon samples. In conclusion, the results demonstrate significantly reduced capacity fading in the doped sample, corroborating the theoretical framework and showcasing the potential of aluminum doping for improved Li‐ion battery performance.
Here, in this study, microstructural studies and micro-mechanical testing of an ex-plant material harvested from the decommissioned pressurized water reactor (PWR) is carried out. Irradiated 304 stainless steel (SS) components were harvested by the Electric Power Research Institute, U.S. Nuclear Regulatory Commission, and members of the José Cabrera Nuclear Power Station (Zorita) in Spain. The bi-crystalline micro-tensile specimens, atom probe tomography (APT) tips, and transmission electron microscopy (TEM) lamellae were fabricated from the baffle plate materials irradiated to 0.05, 15 and 50 dpa to elucidate microstructural, microchemical, and local mechanical properties changes as a function of dose. TEM and APT studies reveal radiation induced Ni, Cr, and Si rich precipitates in the 15 dpa sample that become smaller and partially redissolve into the matrix of the 50 dpa sample (decreasing size and number density). Dislocation loop and cavity number density and size were quantified as a function of dose as well as swelling. Intergranular Ni and Si enrichments with concomitant Fe and Cr depletion were observed in the 15 dpa sample and were more pronounced in the 50 dpa sample. Micro-tensile testing performed in the scanning electron microscope (SEM) at room temperature and 300 °C shows that the material's local yield strength and ultimate tensile strength decreases with increased dose and elevated test temperature and provides further insights via localized strain mapping. Current and previous mechanical data was compared with calculated values using the dispersed barrier hardening model with inputs of dislocation loops, precipitates, and cavities from microstructural characterization.
We observed enhanced net lithium deposition and lithium erosion, possibly dominated by physical sputtering of lithium by lithium-ion bombardment, on the outer plasma-facing surface in the Lithium Tokamak eXperiment-β (LTX-β) during liquid lithium wall operations. Silicon crystal samples with micro-trenches (30 μm × 30 μm × 2–7 μm deep) were exposed to hydrogen plasmas in LTX-β for solid and liquid lithium wall operations. Post-mortem analysis using X-ray photoelectron spectroscopy combined with argon ion sputtering measured net lithium deposition of 8.2 or 21 nm on the silicon crystal surface exposed for ~ 50 repeated shots of ~ 50-ms hydrogen plasma discharges during the liquid lithium wall operations at a vessel temperature of 475 K. Energy dispersive X-ray spectroscopy measured oxygen concentration patterns on the micro-trench floors, which were due to oxidized lithium deposition. Using the inhomogeneous oxygen concentration pattern caused by an ion-shadowing effect associated with the micro-trench’s geometric structure, we determined a polar incident ion direction of 68.4 ± 1.6° referenced to the surface normal direction. This observation was well-explained by the hypothesis that self-sputtering of Li was a dominant lithium erosion source in addition to lithium sputtering by hydrogen bombardment.
Abstract Various researchers have studied fluctuations in pore‐scale phase occupancy during multiphase flow in porous media using synchrotron‐based X‐ray microcomputed tomography (micro‐CT). However, the impact of these fluctuations on the concept of a representative volume is not yet fully understood. In this study, we performed spatial and temporal averaging of multiphase flow experiments visualized with synchrotron‐based micro‐CT, focusing on oil saturation as the key parameter to determine a representative time‐and‐space average. Our findings revealed that a saturation value representative of both time and space was achieved during fractional flow experiments in drainage mode with fractional flows of 0.8, 0.5, and 0.3. Furthermore, we computed a range of relative permeabilities on the basis of whether momentaneous saturation or time‐and‐space averaged saturation was utilized for direct simulation. Our results highlighted the importance of time‐and‐space averaging in determining a representative relative permeability and indicated that the temporal and spatial scales covered in a typical micro‐CT flow experiment were sufficient to obtain a representative saturation value for sandstone rock under intermittent flow conditions.
Magnetic reconnection is a ubiquitous fundamental process in space and astrophysical plasmas that rapidly converts magnetic energy into some combination of flow energy, thermal energy, and non-thermal energetic particles. Over the past decade, a new experimental platform has been developed to study magnetic reconnection using strong coil currents powered by high-power lasers at low plasma beta, typical conditions under which reconnection is energetically important in space and astrophysics. KJ-class lasers were used to drive parallel currents to reconnect MG-level magnetic fields in a quasi-axisymmetric geometry, similar to the magnetic reconnection experiment or MRX, and thus this platform is named micro-MRX. This presentation summarizes two major findings from micro-MRX: direct measurement of accelerated electrons and observation of ion acoustic waves during anti-parallel reconnection. The angular dependence of the measured electron energy spectrum and the resulting accelerated energies, supported by particle-in-cell simulations, indicate that direct acceleration by the out-of-plane reconnection electric field is at work. Furthermore, a sudden onset of ion acoustic bursts has been measured by collective Thomson scattering in the exhaust of magnetic reconnection, followed by electron acoustic bursts with electron heating and bulk acceleration. These results demonstrate that the micro-MRX platform offers a novel and unique approach to study magnetic reconnection in the laboratory in addition to the capabilities provided by traditional magnetized plasma experiments such as MRX and the upcoming Facility for Laboratory Reconnection experiments (FLARE). Future prospects to study other particle acceleration mechanisms and ion acoustic waves from magnetic reconnection are also discussed.
We performed synchrotron-based micro-X-ray absorption near-edge spectroscopy (µ-XANES) coupled with micro-X-ray fluorescence (µ-XRF) for the identification of elements that included biometal zinc (Zn) and nonmetal sulfur (S) (and its species) in the condylar zones of a rat temporomandibular joint (TMJ). Zone-specific spatial localization of biometal Zn and nonmetal S from a materials viewpoint when correlated with hypoxia inducible factor-1α (HIF-1α) (a surrogate for tissue oxygenation) can provide insights into Zn-specific redox pathways at the vulnerable subchondral interface. Histologic localization of Zn, HIF-1α, and sulfur-rich proteoglycans (PGs) were mapped using an optical microscope. The µ-XRF maps coupled with site-specific micro-X-ray diffraction (µ-XRD) patterns were used to underline Zn-incorporated biological apatite in the subchondral bone and the bone of a rat TMJ condyle. Results demonstrated an association between Zn, PG, and HIF-1α histologic maps with µ-XRF, µ-XANES, and µ-XRD data and provided insights into plausible biological S species in Zn-enriched zones of a rat TMJ condyle. Spatially localized Zn and S underscore their roles in cell and tissue functions in a zone-specific manner. Elemental Zn with organic and inorganic S species at the cartilage-bone interface and the biomineral phase of Zn-enriched biological apatite from subchondral bone to condylar bone were ascertained using µ-XRF-XANES and µ-XRF-XRD. The coupled µ-XRF-XANES in situ complemented with µ-XRF-XRD in situ and immunohistochemistry provided valuable biological insights into zone-specific biological pathways in rat TMJ condyles. Based on these data, we present a workflow to reliably map and correlate S species within Zn-enriched regions of cartilage, bone, and their interface. We suggest the use of this correlative and complementary microspectroscopic spatial information for zone-specific localization of biometal Zn and nonmetal S to gain insights into plausible microanatomy-specific oxidative stress in the TMJ.
Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.
Populations of Bull Trout Salvelinus confluentus and Westslope Cutthroat Trout Oncorhynchus clarkii lewisi in the Pend Oreille Basin have declined, partly due to fragmentation caused by hydropower dams. This study aimed to analyze the movements and behavior of these species downstream of Albeni Falls Dam over two years to inform fishway design. Radiotracking investigations were conducted to monitor 10 adult Bull Trout and 17 adult Westslope Cutthroat Trout from September 2008 to July 2010. Macro and micro detection zones were delineated to study fine- and large-scale movements in the tailrace. Macro zones included the spillway and powerhouse tailrace areas. Micro zones were nested within macro zones to identify regions close to the dam where fishway structures could be built. Both Bull Trout and Westslope Cutthroat Trout exhibited high mobility in the dam tailrace, transitioning between macro detection zones. Seasonal variations influenced their distribution patterns. During the spring freshet migration season, both species were primarily detected at the left powerhouse micro zone. In sedentary periods (fall/winter and summer), fish actively swam throughout the tailrace, displaying search behavior. These behavior observations suggest that potential fishway entrances located near dam concrete would be effective: the area near the left powerhouse was identified as the optimal construction location. This study highlights the feasibility of designing fish passage structures to mitigate population fragmentation and support species recovery.