Search NASA⌕ Search

SEARCH · Search NASA

Results for “microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Low intensity X-ray and gamma-ray imaging device

A radiation to visible light converter is combined with a visible light intensifier. The converter is a phosphor or scintillator material which is modified to block ambient light. The intensifier includes fiber optics input and output face plates with a photocathode-microchannel plate amplifier-phosphor combination. Incoming radiation is converted to visible light by the converter which is piped into the intensifier by the input fiber optics face plate. The photocathode converts the visible light to electrons which are amplified by a microchannel plate amplifier. The electrons are converted back to light by a phosphor layer and piped out for viewing by the output fiber optics faces plate. The converter-intensifier combination may be further combined with its own radiation source or used with an independent source.

Yin, L. I.↗

Detector arrays for photometric measurements at soft X-ray, ultraviolet and visible wavelengths

The construction and modes of operation of the Multi-Anode Microchannel Array (MAMA) detectors are described, and the designs of spectrometers utilizing them are outlined. MAMA consists of a curved microchannel array plate, an opaque photocathode (peak quantum efficiency of 19% at 1216 A), and a multi-anode (either discrete- or coincidence-anode) readout array. Designed for use in instruments on spaceborne telescopes, MAMA can be operated in a windowless configuration in extreme-ultraviolet and soft X-ray wavelengths, or in a sealed configuration at UV and visible wavelengths. Advantages of MAMA include low applied potential (less than 3.0 kV), high gain (greater than 10 to the 6th electrons/pulse), low sensitivity to high-energy charged particles, and immunity to external magnetic fields of less than 500 Gauss

Timothy, J. G.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗

Images of the future - Two decades in astronomy

Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.

Weistrop, D.↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

An intensified photodiode array detector for space applications

The Hopkins Ultraviolet Telescope (HUT) is a general purpose moderate resolution spectrograph which is now being constructed for launch on the Space Shuttle. The instrument contains a Rowland spectrograph, which is located at the prime focus of a 0.9-m f/2 parabola. A description is given of the progress which has been made in the development of a flight detector for HUT. The detector developed is an intensified photodiode array. The image intensifier part of the detector contains two 25-mm 80:1, 12-micron pore microchannel plates (PCPs). A thin layer of CsI deposited on the front surface of the first microchannel plate has the objective to increase the quantum efficiency of the detector below 1850 A. The detector system utilizes a spectrometer processor (SP) which is based upon a bit-sliced microprocessor. The current status of the HUT detector system is discussed, and aspects of performance are evaluated. It is felt that the developed system will meet or exceed the design requirements.

Long, K. S.↗

Hybrid analog/digital, large format, photon counting detectors for astronomy

The development of a new microchannel plate photon-counting detector with an analog readout method based on a resistive anode is reported. This detector exhibits extremely high, stable electron gains of 10 to the 8th. At this gain, the spatial resolution is no longer primarily limited by the noise of the resistive anode, so that digital methods of readout, such as discrete conductors, lose their advantage. These detectors can be readily scaled to 40 mm and 70 mm formats to match plate scales of 2-m (and larger) telescopes. New, high speed digital electronics fully exploit the high spatial and time resolution made possible by gains of this level. Analysis of the theoretical performance of this detector shows that the major limitation to the spatial resolution is the proximity focus of the photocathode and the first microchannel plate. The detector has been mated to an echelle spectrograph developed.

Crocker, J.↗

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.↗

Phase Separators And Fountain-Effect Pumps For He 11

Fused-glass microchannel arrays for use as HE 11 phase separators and fountain-effect pumps. Microchannel devices for use in low-gravity storage and cooling systems containing superfluid helium. Phase separators and pumps take advantage of thermomechanical effect peculiar to He 11 in restricted spaces. By creating thermal gradient in porous plug, direction of flow reversed, turning phase separator into pump. However, addition of heat disadvantage. Thermal gradient created by using Peltier effect to transfer heat across array, removing heat from He 11 supply and overcoming undesirable addition of heat.

Whitehouse, Paul L.↗

Synchrotron radiation calibration of the EUVE variable line-spaced diffraction gratings at the NBS SURF II facility

The Extreme Ultraviolet Explorer (EUVE) has a spectrometer which utilizes variable line-spaced, plane diffraction gratings in the converging beam of a Wolter-Schwarzschild type II mirror. The gratings, microchannel plate detector, and thin film filters have been calibrated with continuum radiation provided by the NBS SURF II facility. These were calibrated in a continuum beam to find edges or other sharp spectral features in the transmission of the filters, quantum efficiency of the microchannel plate detector, and efficiency of the gratings. The details of the calibration procedure and the results of the calibration are presented.

Jelinsky, P.↗

A probe for real-time images of particle beams and their analyses in a merged-beams apparatus

A real-time charged particle beam probe was developed, which can be used both as a beam diagnostic (beam tuning) and to quantitatively determine the three-dimensional density distribution of a beam. The probe consists of a microchannel plate, an aluminized phosphor screen deposited on a fiber-optic faceplate, a flexible fiber-optic bundle, and a charge injection device (CID) in tandem. Digital or analog video output of the CID is fed into a computer or oscilloscope, respectively, for analysis or observation. The probe can be moved continuously along the beams' paths to obtain 'pictures' of the beam at any desired interval, thus giving three-dimensional form factors. The beams, singly or simultaneously, may be observed on the monitor facilitating the task of beam adjustment for optimum overlap. The digital output is used for quantitative computation of the beam overlaps. The device is linear with beam intensity, but the performance degrades with time due to beam damage of the microchannel plate.

Forand, J. L.↗

Imaging MAMA detector systems

Imaging multianode microchannel array (MAMA) detector systems with 1024 x 1024 pixel formats have been produced for visible and UV wavelengths; the UV types employ 'solar blind' photocathodes whose detective quantum efficiencies are significantly higher than those of currently available CCDs operating at far-UV and EUV wavelengths. Attention is presently given to the configurations and performance capabilities of state-of-the-art MAMA detectors, with a view to the development requirements of the hybrid electronic circuits needed for forthcoming spacecraft-sensor applications. Gain, dark noise, uniformity, and dynamic range performance data are presented for the curved-channel 'chevron', 'Z-plate', and helical-channel high gain microchannel plate configurations that are currently under evaluation with MAMA detector systems.

Slater, David C.↗

Receiver performance of laser ranging measurements between the Lunar Observer and a subsatellite for lunar gravity studies

The optimal receiver for a direct detection laser ranging system for slow Doppler frequency shift measurement is shown to consist of a phase tracking loop which can be implemented approximately as a phase lock loop with a 2nd or 3rd order loop filter. The laser transmitter consists of an AlGaAs laser diode at a wavelength of about 800 nm and is intensity modulated by a sinewave. The receiver performance is shown to be limited mainly by the preamplifier thermal noise when a silicon avalanche photodiode is used. A high speed microchannel plate photomultiplier tube is shown to outperform a silicon APD despite its relatively low quantum efficiency at wavelengths near 800 nm. The maximum range between the Lunar Observer and the subsatellite for lunar gravity studies is shown to be about 620 km when using a state-of-the-art silicon APD and about 1000 km when using a microchannel plate photomultiplier tube in order to achieve a relative velocity measurement accuracy of 1 millimeter per second. Other parameters such as the receiver time base jitter and drift also limit performance and have to be considered in the design of an actual system.

Davidson, Frederic M.↗

Fundamental and practical limitations of FUV/EUV photon-counting image detectors

In EUV and FUV space-astronomy applications, the best contemporary detector designs are based on the use of microchannel plates due to their ability to deliver photon-counting performance with high efficiency. The major unresolved issue is the choice of position-readout system for the individual photoevents. Electrical event-readout systems are divided into two classes: the discrete wire anodes that perform coordinate digitization by wire-group selection, and the continuous centroid-position encoders for which coordinates are digitized in the associated electronics. The centroid-position encoder techniques are discussed in terms of how they overcome the four chief limitations of the discrete-wire readouts - their limited format size, their flat focal surface, their fundamental hex-channel vs squared-pixel moire pattern, and their image undersampling. With these limitations overcome, microchannel based image systems can deliver the performance demanded by the forthcoming generation of applications in space astronomy.

Lampton, M.↗

Speckle imaging with the MAMA detector: Preliminary results

We report on the first successful speckle imaging studies using the Stanford University speckle interferometry system, an instrument that uses a multianode microchannel array (MAMA) detector as the imaging device. The method of producing high-resolution images is based on the analysis of so-called 'near-axis' bispectral subplanes and follows the work of Lohmann et al. (1983). In order to improve the signal-to-noise ratio in the bispectrum, the frame-oversampling technique of Nakajima et al. (1989) is also employed. We present speckle imaging results of binary stars and other objects from V magnitude 5.5 to 11, and the quality of these images is studied. While the Stanford system is capable of good speckle imaging results, it is limited by the overall quantum efficiency of the current MAMA detector (which is due to the response of the photocathode at visible wavelengths and other detector properties) and by channel saturation of the microchannel plate. Both affect the signal-to-noise ratio of the power spectrum and bispectrum.

Horch, E.↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Role of Boundary Conditions in Monte Carlo Simulation of MEMS Devices

A study is made of the issues surrounding prediction of microchannel flows using the direct simulation Monte Carlo method. This investigation includes the introduction and use of new inflow and outflow boundary conditions suitable for subsonic flows. A series of test simulations for a moderate-size microchannel indicates that a high degree of grid under-resolution in the streamwise direction may be tolerated without loss of accuracy. In addition, the results demonstrate the importance of physically correct boundary conditions, as well as possibilities for reducing the time associated with the transient phase of a simulation. These results imply that simulations of longer ducts may be more feasible than previously envisioned.

Nance, Robert P.↗

Scattered light in the STIS echelle modes

The Space Telescope Imaging Spectrograph (STIS) echelle spectra obtained during the Early Release Observations have non-zero residuals in the cores of saturated interstellar lines, indicating the need for a scattered light correction. A rough measure of the magnitude of the needed correction shows the ratio of the interorder to the in-order flux in different echelle modes in both pre-launch calibration images of a continuum lamp source and in post-launch images of stellar continuum sources. The interorder and in-order fluxes are computed by averaging the central 200 pixels in the dispersion direction. The amount of scattered light in the interorder region rises toward shorter wavelengths for two reasons: (1) the order separation decreases toward shorter wavelengths; and (2) the amount of echelle scattering is expected to have an inverse dependence on wavelength. At the shortest wavelengths the fraction of light scattered into the interorder region can be 10% for the Near-ultraviolet-Multi-Anode Microchannel Array (NUV-MAMA) and 15% for the Far-ultraviolet-Multi-Anode Microchannel Array (FUV-MAMA).

Landsman, W.↗