Internal protein motions in molecular-dynamics simulations of Bragg and diffuse X-ray scattering

Molecular-dynamics (MD) simulations of Bragg and diffuse X-ray scattering provide a means of obtaining experimentally validated models of protein conformational ensembles. This paper shows that compared with a single periodic unit-cell model, the accuracy of simulating diffuse scattering is increased when the crystal is modeled as a periodic supercell consisting of a 2 × 2 × 2 layout of eight unit cells. The MD simulations capture the general dependence of correlations on the separation of atoms. There is substantial agreement between the simulated Bragg reflections and the crystal structure; there are local deviations, however, indicating both the limitation of using a single structure to model disordered regions of the protein and local deviations of the average structure away from the crystal structure. Although it was anticipated that a simulation of longer duration might be required to achieve maximal agreement of the diffuse scattering calculation with the data using the supercell model, only a microsecond is required, the same as for the unit cell. Rigid protein motions only account for a minority fraction of the variation in atom positions from the simulation. The results indicate that protein crystal dynamics may be dominated by internal motions rather than packing interactions, and that MD simulations can be combined with Bragg and diffuse X-ray scattering to model the protein conformational ensemble.

59 BASIC BIOLOGICAL SCIENCES↗

Communication: Oscillating charge migration between lone pairs persists without significant interaction with nuclear motion in the glycine and Gly-Gly-NH-CH{sub 3} radical cations

Coupled electron-nuclear dynamics has been studied, using the Ehrenfest method, for four conformations of the glycine molecule and a single conformation of Gly-Gly-NH-CH{sub 3}. The initial electronic wavepacket was a superposition of eigenstates corresponding to ionization from the σ lone pairs associated with the carbonyl oxygens and the amine nitrogen. For glycine, oscillating charge migration (when the nuclei were frozen) was observed for the 4 conformers studied with periods ranging from 2 to 5 fs, depending on the energy gap between the lone pair cationic states. When coupled nuclear motion was allowed (which was mainly NH{sub 2} partial inversion), the oscillations hardly changed. For Gly-Gly-NH-CH{sub 3}, charge migration between the carbonyl oxygens and the NH{sub 2} lone pair can be observed with a period similar to glycine itself, also without interaction with nuclear motion. These simulations suggest that charge migration between lone pairs can occur independently of the nuclear motion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluid structure interaction of a subaqueous pendulum: Analyzing the effect of wake correction via large eddy simulations

The dynamic behavior of a subaqueous cylindrical pendulum and corresponding flow dynamics are investigated. The objectives were twofold: (i) to examine whether the two-dimensional model equations sufficiently capture the three-dimensional dynamics and (ii) to investigate the emerging three-dimensional vortical flow structures. Large eddy simulations with two-way coupling fluid structure interaction were carried out using the immersed boundary method to simulate the motion of the pendulum and its interactions with the initially stagnant water. The resulting pendulum motion is compared against measured data obtained in a series of experimental tests to validate the simulation results and the model equations with and without wake corrections. An analysis of the flow vorticity revealed the development of a vortex ring during the first swing and the formation of tip vortices. The evolution of the vortex rings emerging from the motion of the subaqueous cylindrical pendulum was visualized using Q-criteria showing a reasonable agreement with vortical structures observed in the experiment using particle imaging velocimetry. The hydrodynamic moments acting on the simulated pendulum and the moments calculated from the model equations are analyzed. Using the insights from these numerical simulations, a modification of the wake correction is proposed to enhance the accuracy of the rate of decay and period. The transient effect of coherent flow on pendulum dynamics, especially the added mass effect, is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated rheology model: Explosive Composition B-3

Composition B-3 (Comp B-3) is a high explosive formulation composed of 60/40wt% RDX (1,3,5-trinitroperhydro-1,3,5-triazine) /TNT (2,4,6 trinitrotoluene). Above approximately 78°C this formulation partially melts to form a multiphase system with solid RDX particles in a molten TNT matrix. This multiphase system presents a number of phenomena that influence its apparent viscosity. In an earlier study explosive Composition B-3 (Comp B-3, 60/40wt% RDX/TNT) was examined for evidence of yield stress using a non-isothermal falling ball viscometer and a yield stress model was proposed in this paper. An integrated viscosity model suitable for use in computational fluid dynamics (CFD) simulations is developed to capture the transition from a heterogeneous solid to a Bingham viscoplastic fluid. This viscosity model is used to simulate the motion of imbedded spheres falling through molten Comp B-3. Finally, comparison of the simulations to physical tests show agreement between the positions predicted by the model and the measured locations of the spheres as a function of temperature between 90C and 165C.

36 MATERIALS SCIENCE↗

Adaptive local learning in sampling based motion planning for protein folding

Background: Simulating protein folding motions is an important problem in computational biology. Motion planning algorithms, such as Probabilistic Roadmap Methods, have been successful in modeling the folding landscape. Probabilistic Roadmap Methods and variants contain several phases (i.e., sampling, connection, and path extraction). Most of the time is spent in the connection phase and selecting which variant to employ is a difficult task. Global machine learning has been applied to the connection phase but is inefficient in situations with varying topology, such as those typical of folding landscapes. Results: We develop a local learning algorithm that exploits the past performance of methods within the neighborhood of the current connection attempts as a basis for learning. It is sensitive not only to different types of landscapes but also to differing regions in the landscape itself, removing the need to explicitly partition the landscape. We perform experiments on 23 proteins of varying secondary structure makeup with 52–114 residues. We compare the success rate when using our methods and other methods. We demonstrate a clear need for learning (i.e., only learning methods were able to validate against all available experimental data) and show that local learning is superior to global learning producing, in many cases, significantly higher quality results than the other methods. Conclusions: We present an algorithm that uses local learning to select appropriate connection methods in the context of roadmap construction for protein folding. Our method removes the burden of deciding which method to use, leverages the strengths of the individual input methods, and it is extendable to include other future connection methods.

Mathematical & Computational Biology↗

Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy

Purpose: Hypofractionated prostate radiotherapy may benefit from both volumetric modulated arc therapy (VMAT) due to shortened treatment time and intrafraction real-time monitoring provided by implanted radiofrequency(RF) transponders. The authors investigate dosimetrically driven action thresholds (whether treatment needs to be interrupted and patient repositioned) in VMAT treatment with electromagnetic (EM) tracking. Methods: VMAT plans for five patients are generated for prescription doses of 32.5 and 42.5 Gy in five fractions. Planning target volume (PTV) encloses the clinical target volume (CTV) with a 3 mm margin at the prostate-rectal interface and 5 mm elsewhere. The VMAT delivery is modeled using 180 equi-spaced static beams. Intrafraction prostate motion is simulated in the plan by displacing the beam isocenter at each beam assuming rigid organ motion according to a previously recorded trajectory of the transponder centroid. The cumulative dose delivered in each fraction is summed over all beams. Two sets of 57 prostate motion trajectories were randomly selected to form a learning and a testing dataset. Dosimetric end points including CTV D95%, rectum wall D1cc, bladder wall D1cc, and urethra Dmax, are analyzed against motion characteristics including the maximum amplitude of the anterior-posterior (AP), superior-inferior (SI), and left-right components. Action thresholds are triggered when intrafraction motion causes any violations of dose constraints to target and organs at risk (OAR), so that treatment is interrupted and patient is repositioned. Results: Intrafraction motion has a little effect on CTV D95%, indicating PTV margins are adequate. Tight posterior and inferior action thresholds around 1 mm need to be set in a patient specific manner to spare organs at risk, especially when the prescription dose is 42.5 Gy. Advantages of setting patient specific action thresholds are to reduce false positive alarms by 25% when prescription dose is low, and increase the sensitivity of detecting dose limits violations by 30% when prescription dose is high, compared to a generic 2 mm action box. The sensitivity and specificity calculated from the testing dataset are consistent to the learning set, which indicates that the patient specific approach is reliable and reproducible within the scope of the prostate database. Conclusions: This work introduces a formalism for ensuring a VMAT delivery meets the most clinically important dose requirements by using patient specific and dosimetric-driven action thresholds to hold the beam and reposition the patient when necessary. Such methods can provide improved sensitivity and specificity compared to conventional methods, which assume directionally symmetric action thresholds.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

INTERACTIONS OF THE MAGNETOSPHERES OF STARS AND CLOSE-IN GIANT PLANETS

Since the first discovery of an extrasolar planetary system more than a decade ago, hundreds more have been discovered. Surprisingly, many of these systems harbor Jupiter-class gas giants located close to the central star, at distances of 0.1 AU or less. Observations of chromospheric 'hot spots' that rotate in phase with the planetary orbit, and elevated stellar X-ray luminosities, suggest that these close-in planets significantly affect the structure of the outer atmosphere of the star through interactions between the stellar magnetic field and the planetary magnetosphere. Here, we carry out the first detailed three-dimensional magnetohydrodynamics simulation containing the two magnetic bodies and explore the consequences of such interactions on the steady-state coronal structure. The simulations reproduce the observable features of (1) increase in the total X-ray luminosity, (2) appearance of coronal hot spots, and (3) phase shift of these spots with respect to the direction of the planet. The proximate cause of these is an increase in the density of coronal plasma in the direction of the planet, which prevents the corona from expanding and leaking away this plasma via a stellar wind. The simulations produce significant low temperature heating. By including dynamical effects, such as the planetary orbital motion, the simulation should better reproduce the observed coronal heating.

79 ASTRONOMY AND ASTROPHYSICS↗

Computational Approach for Improving Three-Dimensional Sub-Surface Earth Structure for Regional Earthquake Hazard Simulations in the San Francisco Bay Area

In our Exascale Computing Project (ECP) we seek to simulate earthquake ground motions at much higher frequency than is currently possible. Previous simulations in the SFBA were limited to 0.5-1 Hz or lower (Aagaard et al. 2008, 2010), while we have recently simulated the response to 5 Hz. In order to improve confidence in simulated ground motions, we must accurately represent the three-dimensional (3D) sub-surface material properties that govern seismic wave propagation over a broad region. We are currently focusing on the San Francisco Bay Area (SFBA) with a Cartesian domain of size 120 x 80 x 35 km, but this area will be expanded to cover a larger domain. Currently, the United States Geologic Survey (USGS) has a 3D model of the SFBA for seismic simulations. However, this model suffers from two serious shortcomings relative to our application: 1) it does not fit most of the available low frequency (< 1 Hz) seismic waveforms from moderate (magnitude M 3.5-5.0) earthquakes; and 2) it is represented with much lower resolution than necessary for the high frequency simulations (> 5 Hz) we seek to perform. The current model will serve as a starting model for full waveform tomography based on 3D sensitivity kernels. This report serves as the deliverable for our ECP FY2017 Quarter 4 milestone to FY 2018 “Computational approach to developing model updates”. We summarize the current state of 3D seismic simulations in the SFBA and demonstrate the performance of the USGS 3D model for a few selected paths. We show the available open-source waveform data sets for model updates, based on moderate earthquakes recorded in the region. We present a plan for improving the 3D model utilizing the available data and further development of our SW4 application. We project how the model could be improved and present options for further improvements focused on the shallow geotechnical layers using dense passive recordings of ambient and human-induced noise.

58 GEOSCIENCES↗

Numerical simulation of vortex-induced motion of a deep-draft paired-column semi-submersible offshore platform

Understanding and predicting vortex-induced motion (VIM) of offshore systems for deep seawater applications is crucial to improve the system safety and integrity. In this paper, we report on experimental tow-tank measurements and numerical simulations of VIM of a deep-draft offshore platform, specifically Paired-Column Semisubmersible (PC-Semi). The study is carried out in model scale (1:54), at subcritical flow regime with Re~10 4 . Motion of the floating structure has three degrees of freedom: in-line, cross-flow, and yaw. Large periodic cross-flow motion is measured for headings 0°, 11.25°, and 22.5°, for reduced velocities (U r ) between 5 and 10. Considerably smaller cross-flow amplitude is recorded at 45° heading across the U r range considered. An extensive sensitivity study is performed using computational fluid dynamics (CFD) to capture the transient displacement history of VIM (in-line, cross-flow, and yaw motion components). Amplitude and period of cross-flow (transverse) motion are obtained from statistical analysis of VIM time history and subsequently used as the validation criterion between the CFD simulation and the model tests. Satisfactory agreement between the CFD results and tow-tank measurements is achieved with a Delayed Detached Eddy Simulation – Shear Stress Transport (DDES-SST) formulation. Finally, this work provides experimental results and serves as a practical starting point to set up a CFD problem to estimate amplitude and period of cross-flow VIM motion for offshore engineering applications.

42 ENGINEERING↗

SU-E-J-35: Using CBCT as the Alternative Method of Assessing ITV Volume

Purpose To study the accuracy of Internal Target Volumes (ITVs) created on cone beam CT (CBCT) by comparing the visible target volume on CBCT to volumes (GTV, ITV, and PTV) outlined on free breathing (FB) CT and 4DCT. Methods A Quasar Cylindrical Motion Phantom with a 3cm diameter ball (14.14 cc) embedded within a cork insert was set up to simulate respiratory motion with a period of 4 seconds and amplitude of 2cm superioinferiorly and 1cm anterioposteriorly. FBCT and 4DCT images were acquired. A PTV-4D was created on the 4DCT by applying a uniform margin of 5mm to the ITV-CT. PTV-FB was created by applying a margin of the motion range plus 5mm, i.e. total of 1.5cm laterally and 2.5cm superioinferiorly to the GTV outlined on the FBCT. A dynamic conformal arc was planned to treat the PTV-FB with 1mm margin. A CBCT was acquired before the treatment, on which the target was delineated. During the treatment, the position of the target was monitored using the EPID in cine mode. Results ITV-CBCT and ITV-CT were measured to be 56.6 and 62.7cc, respectively, with a Dice Coefficient (DC) of 0.94 and disagreement in center of mass (COM) of 0.59 mm. On the other hand, GTV-FB was 11.47cc, 19% less than the known volume of the ball. PTV-FB and PTV-4D were 149 and 116 cc, with a DC of 0.71. Part of the ITV-CT was not enclosed by the PTV-FB despite the large margin. The cine EPID images have confirmed geometrical misses of the target. Similar under-coverage was observed in one clinical case and captured by the CBCT, where the implanted fiducials moved outside PTV-FB. Conclusion ITV-CBCT is in good agreement with ITV-CT. When 4DCT was not available, CBCT can be an effective alternative in determining and verifying the PTV margin.

60 APPLIED LIFE SCIENCES↗

SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.

60 APPLIED LIFE SCIENCES↗

Validation of Deterministic Broadband Ground Motion and Variability from Dynamic Rupture Simulations of Buried Thrust Earthquakes

According to the article, we numerically model broadband ground motion (up to 5–7.5 Hz⁠) from blind‐thrust scenario earthquakes matching the fault geometry of the 1994 Mw 6.7 Northridge earthquake. Several realizations are modeled (by varying the hypocenter location in the dynamic rupture simulation) in a 1D‐layered velocity profile. In addition, we include Q(f )⁠, nonlinear effects from Drucker–Prager plasticity, and superimpose small‐scale medium complexity in both a 1D‐layered and 3D velocity model within the subsequent wave propagation. We investigate characteristics of the ground motion and its variability up to 50 km from the fault by comparing them with ground‐motion prediction equations (GMPEs), simple proxy metrics, as well as strong ground motion records from the Northridge event. We find that median ground motion closely follows the trend predicted by GMPEs and that the intraevent standard deviation, although varying with hypocenter location, lies near that of GMPE models. Plasticity affects ground‐motion amplitudes in regions near the source, reducing intraevent variability above ∼0.5 Hz⁠. Heterogeneity in the velocity structure on both the regional and small scales is needed for the simulated data to match two proxy metrics: the period‐to‐period correlation of spectral acceleration (SA) and the ratio of maximum‐to‐median SA. Although small‐scale heterogeneity has a negligible effect on median SA for this style of rupture, it serves to significantly increase the cumulative absolute velocity, better agreeing with observations. When compared with strong‐motion data, we find that long‐wavelength velocity structure within our deterministic simulations reduces bias at both short and long periods. Finally, synthetic ground motion at both footwall and hanging‐wall sites has no clear dependence on the distance to rupture (at both short and long periods); directivity is likely overpowering any hanging‐wall effect.

Geochemistry & Geophysics↗

SU-G-BRA-13: An Advanced Deformable Lung Phantom for Analyzing the Dosimetric Impact of Respiratory Motion

Purpose: The difference between three-dimensional (3D) and four-dimensional (4D) dose is affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control for each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate characteristics. Methods: A phantom was designed to simulate diaphragm motion with amplitude in the range 1 to 7 cm and various periods of regular breathing. To simulate different size tumors, tumors were produced by pouring liquid silicone into custom molds created by a 3D printer. The accuracy of phantom diaphragm motion was assessed using calipers and protractor. To control tumor motion, tumor trajectories were evaluated using 4D computed tomography (CT), and diaphragm-tumor correlation curve was calculated by curve fitting method. Three-dimensional dose and 4D dose were calculated and compared according to tumor motion. Results: The accuracy of phantom diaphragm motion was less than 1 mm. Maximum tumor motion amplitudes in the left-right and anterior-posterior directions were 0.08 and 0.12 cm, respectively, in a 10 cm{sup 3} tumor, and 0.06 and 0.27 cm, respectively, in a 90 cm{sup 3} tumor. The diaphragm-tumor correlation curve showed that tumor motion in the superior-inferior direction was increased with increasing diaphragm motion. In the 10 cm{sup 3} tumor, the tumor motion was larger than the 90 cm{sup 3} tumor. According to tumor motion, variation of dose difference between 3D and 4D was identified. Conclusion: The developed phantom can independently control factors such as tumor size and motion. In potentially, this phantom can be used to quantitatively analyze the dosimetric impact of respiratory motion according to the factors that influence the difference between 3D and 4D dose. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

Ion motion in the wake driven by long particle bunches in plasmas

In this paper, we explore the role of the background plasma ion motion in self-modulated plasma wakefield accelerators. We employ Dawson's plasma sheet model to derive expressions for the transverse plasma electric field and ponderomotive force in the narrow bunch limit. We use these results to determine the on-set of the ion dynamics and demonstrate that the ion motion could occur in self-modulated plasma wakefield accelerators. Simulations show the motion of the plasma ions can lead to the early suppression of the self-modulation instability and of the accelerating fields. The background plasma ion motion can nevertheless be fully mitigated by using plasmas with heavier plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A virtual simulator designed for collision prevention in proton therapy

Purpose: In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Methods: Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine’s components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. Results: All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. Conclusions: The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.

60 APPLIED LIFE SCIENCES↗

Rare transition event with self-consistent theory of large-amplitude collective motion

A numerical simulation method, based on Dang et al.’s self-consistent theory of large-amplitude collective motion, for rare transition events is presented. The method provides a one-dimensional pathway without knowledge of the final configuration, which includes a dynamical effect caused by not only a potential but also kinetic term. Although it is difficult to apply the molecular dynamics simulation to a narrow-gate potential, the method presented is applicable to the case. A toy model with a high-energy barrier and/or the narrow gate shows that while the Dang et al. treatment is unstable for a changing of model parameters, our method stable for it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-J-38: Dose Rates and Preliminary Evaluation of Contouring Similarity Metrics Using 4D Cone Beam CT

Purpose: 4D imaging modalities require detailed characterization for clinical optimization. The On-Board Imager mounted on the linear accelerator was used to investigate dose rates in a tissue mimicking phantom using 4D-CBCT and assess variability of contouring similarity metrics between 4D-CT and 4D-CBCT retrospective reconstructions. Methods: A 125 kVp thoracic protocol was used. A phantom placed on a motion platform simulated a patient’s breathing cycle. An ion chamber was affixed inside the phantom’s tissue mimicking cavities (i.e. bone, lung, and soft tissue). A sinusoidal motion waveform was executed with a five second period and superior-inferior motion. Dose rates were measured at six ion chamber positions. A preliminary workflow for contouring similarity between 4D-CT and 4D-CBCT was established using a single lung SBRT patient’s historical data. Average intensity projection (Ave-IP) and maximum intensity projection (MIP) reconstructions generated offline were compared between the 4D modalities. Similarity metrics included Dice similarity coefficient (DSC), Hausdorff distance, and center of mass (COM) deviation. Two isolated lesions were evaluated in the patient’s scans: one located in the right lower lobe (ITVRLL) and one located in the left lower lobe (ITVLLL). Results: Dose rates ranged from 2.30 (lung) to 5.18 (bone) E-3 cGy/mAs. For fixed acquisition parameters, cumulative dose is inversely proportional to gantry speed. For ITVRLL, DSC were 0.70 and 0.68, Hausdorff distances were 6.11 and 5.69 mm, and COM deviations were 1.24 and 4.77 mm, for Ave-IP and MIP respectively. For ITVLLL, DSC were 0.64 and 0.75, Hausdorff distances were 10.74 and 8.00 mm, and COM deviations were 7.55 and 4.3 mm, for Ave-IP and MIP respectively. Conclusion: While the dosimetric output of 4D-CBCT is low, characterization is necessary to assure clinical optimization. A basic workflow for comparison of simulation and treatment 4D image-based contours was established. This work was partially supported by a Research Scholar Grant (RSG-15-137-01-CCE) from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗