Search NASA⌕ Search

SEARCH · Search NASA

Results for “normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Ultrafast Raman probe of the photoinduced superconducting to normal state transition in the cuprate Bi 2 ⁢Sr 2 ⁢CaCu 2 ⁢O 8+𝛿

Here, we report an ultrafast Time-Resolved Raman scattering study of the out-of-equilibrium photoinduced dynamics across the superconducting to normal state phase transition of the cuprate Bi 2 ⁢Sr 2⁢ CaCu 2 ⁢O 8+𝛿 . Using the polarization-resolved momentum space selectivity of Raman scattering, we track the superconducting condensate destruction and recovery dynamics with subpicoseconds time resolution in the antinodal region of the Fermi surface where the superconducting gap is maximum. Leveraging ultrafast Raman thermometry, we find a significant dichotomy between the superconducting condensate and the quasiparticle temperature dynamics near the antinodes, which cannot be framed in terms of a single effective electron temperature. The present work demonstrates the ability of Time-Resolved Raman scattering to selectively probe out-of-equilibrium pathways of different electronic subdegrees of freedom during a photoinduced phase transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Autonomous Electrochemistry Platform with Real-Time Normality Testing of Voltammetry Measurements Using ML

Electrochemistry workflows utilize various instruments and computing systems to execute workflows consisting of electrocatalyst synthesis, testing and evaluation tasks. The heterogeneity of the software and hardware of these ecosystems makes it challenging to orchestrate a complete workflow from production to characterization by automating its tasks. We propose an autonomous electrochemistry computing platform for a multi-site ecosystem that provides the services for remote experiment steering, real-time measurement transfer, and AI/ML-driven analytics. We describe the integration of a mobile robot and synthesis workstation into the ecosystem by developing custom hub-networks and software modules to support remote operations over the ecosystem’s wireless and wired networks. We describe a workflow task for generating I-V voltammetry measurements using a potentiostat, and a machine learning framework to ensure their normality by detecting abnormal conditions such as disconnected electrodes. We study a number of machine learning methods for the underlying detection problem, including smooth, non-smooth, structural and statistical methods, and their fusers. We present experimental results to illustrate the effectiveness of this platform, and also validate the proposed ML method by deriving its rigorous generalization equations.

Alnajjar, Anees↗

Synchronized Phasor Measurement Unit-based Central Controller for Normal and Contingent Operation of a High-Capacity HVDC Macrogrid for the Continental US

This paper presents a Synchronized Phasor Measurement Unit (PMU) based controller to support the coordination and operation of a high-capacity high-voltage direct current (HVDC) macrogrid transmission for the continental US. The proposed controller allows for optimal scheduling of each segment of the multi-terminal HVDC network under normal and contingent conditions, while considering minimum levels of frequency response requirements. The performance of the proposed controller is tested on a 100,222-bus representation of the US Eastern and Western interconnections. Results show that a centralized PMU-based controller improves the frequency nadir of the HVDC macrogrid under contingency conditions by 25.9%. Furthermore, the primary frequency response (PFR) of the HVDC macrogrid is increased by 33.4%. The performance of each interconnection under the largest credible contingency conditions is also discussed.

Mohan, Nihal↗

Coinfection of Influenza A and B and Human OC43 Coronavirus in Normal Human Bronchial Epithelial Cells

Influenza viruses and seasonal coronaviruses are pathogens transmitted via an airborne route that can cause respiratory diseases in humans that have similar symptoms such as fever, cough, and pneumonia. These two viruses can infect similar human tissues, such as the respiratory tract and nasal, bronchial, and alveolar epithelial cells. Influenza virus and seasonal coronavirus coinfections are poorly understood. Here, we coinfected normal human bronchial epithelial (NHBE) cells with influenza A/California/04/09 (IAV) or B/Victoria/504/2000 (IBV) strains and the seasonal human beta-coronavirus OC43 and evaluated viral replication capacities. We also examined changes in the expression of various cytokines/chemokines by qPCR and Luminex assay. We observed that the replication of IAV and IBV was not affected by coinfection with OC43. However, coinfection reduced OC43 titers (~3-fold) compared with infection with OC43 alone. Select cytokine/chemokine expression was increased in coinfected cells compared with all single infections with greater differences seen between coinfected cells and cells infected with OC43 alone compared with IAV- or IBV-infected cells. In addition, IL-8 and IL-1RA showed the highest expression among a panel of 22 cytokines by Luminex. As the rate of influenza and seasonal coronavirus coinfection continue to increase, our findings may help set guidelines for the treatments of the individuals coinfected with both viruses.

60 APPLIED LIFE SCIENCES↗

QuantumNAT: quantum noise-aware training with noise injection, quantization and normalization

Parameterized Quantum Circuits (PQC) are promising towards quantum advantage on near-term quantum hardware. However, due to the large quantum noises (errors), the performance of PQC models has a severe degradation on real quantum devices. Take Quantum Neural Network (QNN) as an example, the accuracy gap between noise-free simulation and noisy results on IBMQ-Yorktown for MNIST-4 classification is over 60%. Existing noise mitigation methods are general ones without leveraging unique characteristics of PQC; on the other hand, existing PQC work does not consider noise effect. To this end, we present QuantumNAT, a PQC-specific framework to perform noise-aware optimizations in both training and inference stages to improve robustness. We experimentally observe that the effect of quantum noise to PQC measurement outcome is a linear map from noise-free outcome with a scaling and a shift factor. Motivated by that, we propose post-measurement normalization to mitigate the feature distribution differences between noise-free and noisy scenarios. Furthermore, to improve the robustness against noise, we propose noise injection to the training process by inserting quantum error gates to PQC according to realistic noise models of quantum hardware. Lastly, post-measurement quantization is introduced to quantize the measurement outcomes to discrete values, achieving the denoising effect. Extensive experiments on 8 classification tasks using 6 quantum devices demonstrate that QuantumNAT improves accuracy by up to 43%, and achieves over 94% 2-class, 80% 4-class, and 34% 10-class classification accuracy measured on real quantum computers. The code for construction and noise-aware training of PQC is available in the TorchQuantum library.

Wang, Hanrui↗

Normalization of CSF pTau measurement by Aβ 40 improves its performance as a biomarker of Alzheimer’s disease

Alzheimer’s disease (AD)-related tauopathy can be measured with CSF phosphorylated tau (pTau) and tau PET. We aim to investigate the associations between these measurements and their relative ability to predict subsequent disease progression. In 219 cognitively unimpaired and 122 impaired Alzheimer’s Disease Neuroimaging Initiative participants with concurrent amyloid-β (Aβ) PET ( 18 F-florbetapir or 18 F-florbetaben), 18 F-flortaucipir (FTP) PET, CSF measurements, structural MRI, and cognition, we examined inter-relationships between these biomarkers and their predictions of subsequent FTP and cognition changes. The use of a CSF pTau/Aβ 40 ratio eliminated positive associations we observed between CSF pTau alone and CSF Aβ 42 in the normal Aβ range likely reflecting individual differences in CSF production rather than pathology. Use of the CSF pTau/Aβ 40 ratio also increased expected associations with Aβ PET, FTP PET, hippocampal volume, and cognitive decline compared to pTau alone. In Aβ+ individuals, abnormal CSF pTau/Aβ 40 only individuals (26.7%) were 4 times more prevalent (p < 0.001) than abnormal FTP only individuals (6.8%). Furthermore, among individuals on the AD pathway, CSF pTau/Aβ 40 mediates the association between Aβ PET and FTP PET accumulation, but FTP PET is more closely linked to subsequent cognitive decline than CSF pTau/Aβ 40 . Together, these findings suggest that CSF pTau/Aβ 40 may be a superior measure of tauopathy compared to CSF pTau alone, and CSF pTau/Aβ 40 enables detection of tau accumulation at an earlier stage than FTP among Aβ+ individuals.

60 APPLIED LIFE SCIENCES↗

White Beam Normalization

Raw data used to normalize detector performance on the ARCS instrument For the run cycle starting in June 2023. This is a V cylinder and the T0 chopper is set to 150 Hz and phased for 300 meV. All Fermi Choppers are out of the Beam.

MATERIALS SCIENCE↗

Dose-Rate Effects of Protons and Light Ions for DNA Damage Induction, Survival and Transformation in Apparently Normal Primary Human Fibroblasts

In this work, we report on effects of low-dose exposures of accelerated protons delivered at high-dose rate (HDR) or a simulated solar-particle event (SPE) like low-dose rate (LDR) on immediate DNA damage induction and processing, survival and in vitro transformation of low passage NFF28 apparently normal primary human fibroblasts. Cultures were exposed to 50, 100 and 1,000 MeV monoenergetic protons in the Bragg entrance/plateau region and cesium-137 γ rays at 20 Gy/h (HDR) or 1 Gy/h (LDR). DNA double-strand breaks (DSB) and clustered DNA damages (containing oxypurines and abasic sites) were measured using transverse alternating gel electrophoresis (TAFE) and immunocytochemical detection/scoring of colocalized γ-H2AX pS139/53BP1 foci, with their induction being linear energy transfer (LET) dependent and dose-rate sparing observed for the different damage classes. Relative biological effectiveness (RBE) values for cell survival after proton irradiation at both dose-rates ranged from 0.61–0.73. Transformation RBE values were dose-rate dependent, ranging from ~1.8–3.1 and ~0.6–1.0 at low doses (≤30 cGy) for HDR and LDR irradiations, respectively. However peak transformation frequencies were significantly higher (1.3–7.3-fold) for higher doses of 0.5–1 Gy delivered at SPE-like LDR. Cell survival and transformation frequencies measured after low-dose 500 MeV/n He-4, 290 MeV/n C-12 and 600 MeV/n Si-28 ion irradiations also showed an inverse dose-rate effect for transformation at SPE-like LDR. This work demonstrates the existence of inverse dose-rate effects for proton and light-ion-induced postirradiation cell survival and in vitro transformation for space mission-relevant doses and dose rates.

59 BASIC BIOLOGICAL SCIENCES↗

Progress on the normal conducting magnets for the Electron-Ion Collider

The electron-ion collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 1e+34 1/cm2 1/sec. The EIC will take advantage of the existing Relativistic Heavy Ion Collider (RHIC) facility. Two additional rings will be installed: an electron storage ring (ESR) and a rapid cycling electron synchrotron ring (RCS).This paper presents an update on the normal conducting magnet designs required for both the ESR and RCS rings. The ESR will store polarized electron beams up to 18 GeV and utilizes a triplet of dipole magnets to increase the emittance at 5 GeV and generate excess bending to create additional radiation damping to allow a larger beam-beam tune shift. The RCS will accelerate single bunches of spin-polarized electrons at various energies from 5 GeV to 18 GeV, with a ramp rate of 100 ms and 1 Hz repetition rate. Both rings require dipole, quadrupole and sextupole magnets with different specifications.

43 PARTICLE ACCELERATORS↗

MENT-Flow: maximum-entropy phase space tomography using normalizing flows

Generative models can be trained to reproduce low-dimensional projections of high-dimensional phase space distributions. Normalizing flows are generative models that parameterize invertible transformations, allowing exact probability density evaluation and sampling. Consequently, flows are unbiased entropy estimators and could be used to solve the high-dimensional maximum-entropy tomography (MENT) problem. In this work, we evaluate a flow-based MENT solver (MENT-Flow) against exact maximum-entropy solutions and Minerbo's iterative MENT algorithm in two dimensions.

Hoover, Austin↗

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics↗