Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear forensic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Impact of Precipitation Parameters on the Specific Surface Area of PuO 2

Controlling the properties of PuO 2 through processing is of vital importance to environmental transport and fate, production of nuclear fuels, nuclear forensic analyses, stockpile stewardship, and storage of nuclear wastes applications. A number of processing conditions have been identified to control final product properties, including specific surface area (SSA), residual carbon content, adsorption of volatile species, morphology, and particle size. In this paper, a novel approach is developed for the prediction of PuO 2 SSA via the synthetic route of Pu(IV) oxalate precipitation followed by calcination. The proposed model utilizes multivariate regression methodology and leave one out formalism to link Savannah River Site (SRS) precipitation and calcination production data to the SSA of the final product. A comparison among the models provides insight into the accuracy and ability to identify variations amongst the processing data. Additionally, the models may also be used to fit new data outside of the parameters explored in a production facility. Finally, the trained model was compared to a similarly trained conventional model form to illustrate the influence of precipitation parameters on the prediction of the final SSA. The models presented here attempt to provide new methods for more accurate prediction of the PuO 2 product properties in a production scale environment for key environmental and nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Framework for Inverse Prediction Using Functional Response Data

Inverse prediction models have commonly been developed to handle scalar data from physical experiments. However, it is not uncommon for data to be collected in functional form. When data are collected in functional form, it must be aggregated to fit the form of traditional methods, which often results in a loss of information. For expensive experiments, this loss of information can be costly. In this study, we introduce the functional inverse prediction (FIP) framework, a general approach which uses the full information in functional response data to provide inverse predictions with probabilistic prediction uncertainties obtained with the bootstrap. The FIP framework is a general methodology that can be modified by practitioners to accommodate many different applications and types of data. We demonstrate the framework, highlighting points of flexibility, with a simulation example and applications to weather data and to nuclear forensics. Results show how functional models can improve the accuracy and precision of predictions.

42 ENGINEERING↗

Chemical separation and measurement of platinum activation products

Here, a method has been developed to purify and measure platinum radioisotopes in the presence of fission products and environmental constituents. The method uses a combination of cation exchange and anion exchange chromatography and selective precipitation steps to remove other radioisotopes from the sample. The addition of stable platinum carrier allows for a gravimetric determination of the chemical yield of the procedure. Overall, the method is fast, simple, and potentially applicable for rapid turnaround of unknown samples. Using this method, multiple platinum radioisotopes were measured in two different irradiation experiments. The measured ratios of the platinum radioisotopes clearly reflect the neutron spectrum of the irradiation, suggesting that platinum radioisotopes could be valuable signatures in nuclear forensic analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing microscale signatures in uranium ore concentrates using electron probe microanalyzer

Impurities in uranium ore concentrates (UOCs) serve as forensic signatures of processing history and origin. Here, this study utilizes Electron Probe Microanalyzer (EPMA) to characterize microscale compositional and textural features in individual UOC particles from both commercial and bench-scale production. At the particle scale, multiple internal phases with distinct morphologies, chemical signatures, and stoichiometries are documented. Our data shows that chemical impurities are heterogeneously distributed within single particles and among particles within a sample. These microscale heterogeneities correlate with known processing histories, indicating that microscale signatures of early fuel cycle materials can provide valuable information for nuclear forensic material analysis.

organic↗

Single particle trace element analysis of uranium oxide standards with laser-induced breakdown spectroscopy

Femtosecond Laser-Induced Breakdown Spectroscopy (LIBS) was used to analyze over 1000 individual particles of uranium oxide trace element standard CRM124. Intra-granular analysis showed elemental concentrations were consistent across different surface locations on each uranium grain. However, inter-granular comparison revealed large heterogeneity between different grains of the same sample. By comparing the distribution of elemental concentrations across the particle populations, we were able to correctly identify a manufacturing process involving wet chemistry, rather than a dry mixing of two powders to give an overall chemical average. In conclusion, this demonstrates the utility of LIBS as a large-scale single particle analysis tool for nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron capture signatures determined from gadolinium isotope compositions of uranium ore concentrates using MC-ICPMS

We present Gd isotope compositions on 25 well-characterized uranium ore concentrates (UOCs). About half the UOCs have isotope depletions in 157 Gd coupled with anticorrelated excesses in 158 Gd due to neutron capture effects. UOCs from older ore bodies and with higher U contents show larger neutron capture effects than UOCs from younger ore bodies with lower U contents. These Gd data are correlated with their previously measured Sm isotope compositions, and we use the Sm data to estimate the neutron fluence of these samples. In conclusion, this work demonstrates how Gd isotope signatures can be employed as a new tool for nuclear forensics.

Earth Sciences↗

Direct Alpha Spectrometry of Nuclear Fallout

Advanced instruments and methods are under development to allow direct alpha spectrometry of nuclear fallout debris near the point of collection, to support nuclear forensics (NF). New approaches are needed to support NF in order to accelerate the process for data generation and reduce the overall timeline for decision making. Fallout debris at short time periods following detonation can be difficult to work with for alpha spectrometry, due to the presence of intense beta radiation originating from significant quantities of high-activity fission products. Intense beta radiation can challenge traditional silicon-based high-resolution alpha spectrometers. Addressing this, single-crystal (sc) chemical vapor deposition (CVD) produced diamond semiconductors have been studied for use for alpha spectrometry for assaying nuclear fallout debris. Tests have been performed using scCVD sensors to assay a variety of actinide-bearing samples. Sample preparation, when done, has been limited to pulverization using a mechanical ball mill. To reduce measurement times, multi-chip arrays of scCVD diamond semiconductor have been developed in form factors suitable for field deployment in support of NF objectives. These arrays have been tested using high-beta-activity sol gel surrogate nuclear explosive debris (SNED) containing varying concentrations of uranium and plutonium. Results from the use of scCVD detectors with sol gel SNED will be presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving robustness for model discerning synthesis process of uranium oxide with unsupervised domain adaptation

The quantitative characterization of surface structures captured in scanning electron microscopy (SEM) images has proven to be effective for discerning provenance of an unknown nuclear material. Recently, many works have taken advantage of the powerful performance of convolutional neural networks (CNNs) to provide faster and more consistent characterization of surface structures. However, one inherent limitation of CNNs is their degradation in performance when encountering discrepancy between training and test datasets, which limits their use widely. The common discrepancy in an SEM image dataset occurs at low-level image information due to user-bias in selecting acquisition parameters and microscopes from different manufacturers. Therefore, in this study, we present a domain adaptation framework to improve robustness of CNNs against the discrepancy in low-level image information. Furthermore, our proposed approach makes use of only unlabeled test samples to adapt a pretrained model, which is more suitable for nuclear forensics application for which obtaining both training and test datasets simultaneously is a challenge due to data sensitivity. Through extensive experiments, we demonstrate that our proposed approach effectively improves the performance of a model by at least 18% when encountering domain discrepancy, and can be deployed in many CNN architectures.

scanning electron microscopy↗

Production of anhydrous ƒ-element fluorides through the ionothermal treatment of ƒ-element oxalates

The pivotal role of uranium and plutonium fluorides in the nuclear fuel cycle, particularly in the pyrochemical reduction process, is well recognized. Traditionally, the fluorination of uranium and plutonium materials relies on the use of highly toxic and corrosive gases (e.g., HF (g) , F 2(g) ). Herein, we present an alternative approach using the ionic liquid 1‑butyl‑3-methylimidazolium hexafluorophosphate ([Bmim][PF 6 ] (l) ) and/or hexafluorophosphoric acid (HPF 6(aq) ) as fluorinating agents for the ƒ-element oxalates M$^{III}_{2}$(C 2 O 4 ) 3 ∙ 9H 2 O (s) M$^{III}_{2}$(C 2 O 4 ) 3 ∙ 9H 2 O (s) (M III = Ce, Pu) and M IV (C 2 O 4 ) 2 ∙ 6H 2 O (s) (M IV = Th, U). Our findings demonstrate that [Bmim][PF 6 ] (l) and HPF 6(aq) enable the ionothermal fluorination of ƒ-element oxalates, resulting in the formation of anhydrous CeF 3(s) , ThF 4(s) , and UF 4(s) within 2 hours at 200 °C. This method also facilitates the partial fluorination of plutonium(III) oxalate, yielding a mixture of anhydrous PuF 3(s) and an unidentified phase. Overall, the ionothermal treatment approach offers a safer and more efficient means of producing anhydrous ƒ-element fluorides than conventional methods involving hazardous gases. In addition, we describe the morphology of UF 4(s) materials as a function of production route and demonstrate the presence of morphological signatures that could be used during a nuclear forensic investigation.

Cerium↗

Radiochronometric analysis of an historic Cs-137 activity standard

In this work, a 137 Cs activity standard discovered during routine inventory was analyzed to determine its model age using radiochronometry. The aqueous activity standard was separated using an established separation method that employs commercially available Sr resin. The method was also tested against a nuclear forensics reference material developed specifically for benchmarking 137 Cs radiochronometry methods. Results of the analyses showed good agreement between the results and the certified values of the reference material. Analysis of the discovered activity standard were also in good agreement with the activity certification date, though uncertainty was higher due to natural Ba contaminating the sample and the stable 133 Cs used as a carrier during the standard’s production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radioxenon signatures of molten salt reactors

Developments of molten salt reactor (MSR) technologies are making rapid progress across the globe. These reactor designs involve properly controlling radionuclides through off-gas systems. This work examines radioxenon emissions and assesses treaty detection technology to be used for monitoring. This work also includes a sensitivity study with ORIGEN on the nuclear forensic signals possible from a MSR. Multiple Isotope Ratio Comparison (MIRC) plots are used to compare the ratios of radioxenon isotopes in an MSR to a highly enriched uranium (HEU) reactor. Finally, the results show that MSR emissions may significantly overlap with signals produced in a HEU reactor and that changing reactor operations or retaining emissions in an off-gas system can significantly shift the radioxenon signature away from the HEU pulse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

In-situ Synthesis of PuCl 3 and Corresponding Raman and Density Functional Theory Vibrational Modes

The experimental and calculated Raman spectrum of PuCl 3 has been reported for the first time. PuCl 3 is a primary species found in plutonium metal refinement, specifically in pyrochemical salt processes including multicycle direct oxide reduction, metal chlorination, and electrorefining. As such, Raman signatures of PuCl 3 could serve as potential forensic indicators of material process history. A novel technique for synthesizing PuCl 3 from the in situ chlorination of plutonium metal with HCl was developed to establish these signatures. Cerium metal surrogates were utilized to ensure optimization of the plutonium experiments and to minimize personnel exposure, and all experiments were carried out in a Raman reaction chamber designed for air-tight, high vacuum environments. In situ Raman spectroscopy was employed in conjunction with density functional theory (DFT) to investigate the vibrational modes of PuCl 3 . Associated mixed oxy and hydroxyl phases are also reported. The combined Raman and DFT results have eliminated inconsistencies in Raman mode assignments for the MX 3 family of metal chlorides having P6 3 /m symmetry, and IR modes derived from the DFT calculations are additionally presented. The data observed in this study are of potential interest to nuclear forensic analyses, nuclear sample aging, nuclear energy, plutonium processing, and stockpile stewardship.

36 MATERIALS SCIENCE↗

In-situ Synthesis of PuCl 3 and Corresponding Raman and Density Functional Theory Vibrational Modes

The experimental and calculated Raman spectrum of PuCl 3 has been reported for the first time. PuCl 3 is a primary species found in plutonium metal refinement, specifically in pyrochemical salt processes including multicycle direct oxide reduction, metal chlorination, and electrorefining. As such, Raman signatures of PuCl 3 could serve as potential forensic indicators of material process history. A novel technique for synthesizing PuCl 3 from the in-situ chlorination of plutonium metal with HCl was developed to establish these signatures. Cerium metal surrogates were utilized to ensure optimization of the plutonium experiments and to minimize personnel exposure, and all experiments were carried out in a Raman reaction chamber designed for air-tight, high vacuum environments. In-situ Raman spectroscopy was employed in conjunction with Density Functional Theory (DFT) to investigate the vibrational modes of PuCl 3 . Associated mixed oxy and hydroxyl phases are also reported. The combined Raman and DFT results have eliminated inconsistencies in Raman mode assignments for the MX 3 family of metal chlorides having P6 3 /m symmetry, and IR modes derived from the DFT calculations are additionally presented. The data observed in this study is of potential interest to nuclear forensic analyses, nuclear sample aging, nuclear energy, plutonium processing, and stockpile stewardship.

36 MATERIALS SCIENCE↗

Separation of gold from irradiated actinide material utilizing a 2- thenoyltrifluoroacetone extraction resin

Post-detonation nuclear forensics capabilities depend on the ability to rapidly isolate radionuclides to improve measurement quality. In this work an extraction chromatography resin was developed utilizing the extractants thenoyltrifluoroacetone and 1-octanol supported on Eichrom prefilter resin. Here the resin was tested in nitric and hydrochloric acid matrices. In nitric acid matrices the resin is able to extract zirconium, while in hydrochloric acid matrices it is possible to extract iron and gallium. In all acid conditions tested gold is retained but can be removed from the column with a 10% thiourea rinse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of Uranium Foil Irradiations at the WSU TRIGA Reactor Using a New Reactor Model in Scale

A new reactor model of the Washington State University TRIGA was developed in the SCALE neutron transport code, and its fidelity was verified by comparison to MCNP and available data for several reactor parameters. The model was used to characterize irradiations designed to produce the short-lived actinides 237 U and 239 U, two key isotopes for nuclear forensics. These short-lived actinides, their decay daughters 237Np and 239Pu, and total fissions (via 99 Mo) were measured in irradiated foils at Los Alamos National Laboratory and other labs with good agreement among parent/daughter pairs and among labs. The laboratory-measured isotope ratios were used as a benchmark for the model determination of reaction rates. The flux distribution in the foils was also determined. Finally, using the continuous energy TSUNAMI-3D module of SCALE, a sensitivity/uncertainty analysis was performed to determine the effects on foil reactions caused by other system-wide reactions and by uncertainties in the known cross-sections.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Model ages of three uranium metal CRMs and implications for radiochronometry data interpretation

In this study, we report 230 Th/ 234 U and 231 Pa/ 235 U model ages in three uranium metal certified reference materials with distinct production histories and isotopic compositions ranging from depleted to highly enriched (CRMs 112-A, 115, and 116-A). Here, our results provide the first model age values for these materials using multiple radiochronometers, which can be used as reference values for quality control of radiochronometry measurements performed during nuclear forensic investigations. Furthermore, we evaluate the model ages in the context of available production records for the materials, which provides insight into the processes that may impact radiochronometry systems during uranium metal production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

International interlaboratory compilation of trace element concentrations in the CUP-2 uranium ore concentrate standard

Herein, a nuclear forensics investigation involving a uranium ore concentrate relies on accurate and precise analysis of impurities. Analytical data defensibility requires the use of reference materials as part of quality control. This study presents a compilation of trace element concentration results of the CUP-2 Uranium Ore Concentrate Standard measured by 11 different laboratories. The laboratories employed various dissolution methods, analytical preparation methods, and instrumental platforms. The data presented here contain concentrations of 66 impurities with up to 138 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗