Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

DRiFT - Release 2.1.0: Organic Scintillators and Gas Detectors

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that post-processes output from the extensively validated radiation transport code, MCNP, and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. The focus of this release is on organic scintillator, gas detector, and associated capabilities, while semiconductor features are still under development. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. DRiFT also has several diagnostic and detector physics features relevant to neutron gas detector simulations including: gas detector wall effects, inactive areas at the end of detector tubes, and effects of a preamplifier. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of selenium in CdZnTeSe quaternary compound for radiation detector applications

X- and gamma-ray detectors are increasingly becoming essential tool for science and technology in various fields include homeland security, nonproliferation, nuclear security, medical imaging, astrophysics, and high energy physics. Cd 1-x Zn x Te 1-y Se y (CZTS) is emerging as a next-generation compound semiconductor for such applications. CZTS was found to possesses a very low concentration of Te inclusions and free from sub-grain boundary networks. Being a quaternary compound with varying alloy composition, optimization of the composition was performed to determine the minimum amount of selenium required to produce CZTS with reduced defects. The optimized composition was found to be x=0.10 and y=0.02, i.e., Cd 0.9 Zn0.1Te 0.98 Se 0.02 , for excellent material properties as a radiation detector. The resulting material was free from sub-grain boundary networks and with a highly reduced concentration of Te inclusions. The bulk dark resistivity obtained was in the range of 1-3x1010 ohm-cm with the highest achieved mobility-lifetime product of ~6.6x10-3 cm2/V for the optimized CZTS composition. Impurity analyses were performed by the Glow Discharge Mass Spectroscopy (GDMS) technique, and the results showed relatively high impurity concentrations compared to commercial detector-grade CdZnTe. Thus, CZTS has room for further improvement with additional purification of the starting materials.

36 MATERIALS SCIENCE↗

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly Segmented Silicon Strip Detectors for Radiation Detection (LDRD Final Report)

Large area highly segmented silicon strip detectors were investigated for use in applied radiation detection applications. Two ASIC-based readout electronics solutions were tested for compatibility. During the analysis, it was determined that significant computational resources and highly specialized firmware are required to reconstruct the data into a meaningful data stream for generalized spectroscopic performance. Future investment in the technology and careful choice of readout ASIC is expected to demonstrate relevance in measuring high activity samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secondary-Source Core Reload Modeling with VERA

The CASL reactor simulation package VERA has been adapted to provide high-fidelity simulation capabilities for modeling source range detector response during subcritical reactor configurations. New features include the activation and shuffling of secondary-source assemblies, use of burned fuel neutron emission data from the ORIGEN depletion solver to the MPACT deterministic neutron transport solver, allowance of user-defined sources in MPACT based on material composition, ability to solve the subcritical source-driven system with neutron multiplication using the MPACT diffusion solver, and transfer of the calculated fission source from MPACT to the continuous-energy Monte Carlo solver Shift for final detector response evaluation using the CADIS methodology for variance reduction. These new capabilities were benchmarked against Watts Bar Unit 1 plant operating data for the first few fuel loading steps and were found to demonstrate excellent agreement with the measured data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗

Measurement of the Li 7 ( γ , t ) He 4 ground-state cross section between E γ = 4.4 and 10 MeV

Here, the Li 7 ( γ , t ) He 4 ground state cross section was measured for the first time using monoenergetic γ rays with energies between 4.4 and 10 MeV at the High Intensity Gamma-ray Source. The reaction is important for the primordial Li problem and for testing our understanding of the mirror α -capture reactions H 3 ( α , γ ) Li 7 and He 3 ( α , γ ) Be 7 . Although over the last 30 years most measurements of the H 3 ( α , γ ) Li 7 reaction have concentrated in an energy range below E γ = 3.65 MeV, measurements at higher energies could potentially restrict the extrapolation to astrophysically important energies. The experimental arrangement for measuring the Li 7 ( γ , t ) He 4 reaction included a large-area silicon detector array and several beam characterization instruments. The experimental astrophysical S factor of H 3 ( α , γ ) calculated from the present data was fitted using the R -matrix formalism. The results are in disagreement with previous experimental measurements in the same energy range but the extrapolated S factor agrees with the potential model calculation and lower energy experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

INTEGRATION OF THE H3D-M400 DETECTOR AND SPOT ROBOT FOR AUTOMATED AREA SURVEY MISSIONS

Office of Nuclear Smuggling Detection and Deterrence (NSDD) is charged to identify and develop technologies to detect, disrupt, and investigate smuggling of radiological and nuclear materials •Border protection involves primary inspections using Radiation Portal Monitors (RPM), complimented with secondary and area survey inspections, usually performed manually using portable radiation detectors (PRDs) -RPM rely on fast technologies which provide quick scans of passing cargo/vehicles -Secondary inspections rely on trained, field deployed staff responsible for additional interdiction of screened cargo/vehicle putting them in potentially hazardous environment -Area survey inspections rely on trained, field deployed staff responsible for scanning and identifying presence of radiation while patrolling through a facility or public space •This project explores the use of technology which could reduce risks to field inspectors and add efficiency •The work presented here is a proof of principle of detector-robot integration to perform area survey inspections

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Large-area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-β decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work, we showcase light detectors based on an alternative Ir-Pt bilayer transition-edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of < 100 eV rms. Our detectors have risetimes of approximately 180μs and measured timing jitter of < 20μs for the expected signal to noise at the Q value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-β decay pile-up events. In conclusion, the current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The polarization sensitivity of GRETINA

Compton polarimeters have played an important role in the study of nuclear structure physics, but have often been limited in their applications because of relatively low -ray detection efficiency. With the advent of -ray tracking detector arrays, which feature nearly solid angle coverage and the ability to identify the location of Compton-scattering events to within a few millimeters, this limitation can be overcome. Here we present a characterization of the performance of the Gamma Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter using the 24 Mg(p,p') reaction at 2.45 MeV proton energy. We also discuss a new capability added to the simulation package UCGretina to simulate the emission of polarized photons, and compare it to the measured data. Lastly, we use these simulations to predict the performance of the Gamma Ray Energy Tracking Array (GRETA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 488: MUSiC Accomplishments and Goals [Slides]

IER-488: Measurement of Uranium Subcritical and Critical (MUSiC) consists of measurements of bare, HEU systems covering a large range of reactivities. Multiple detector systems and analysis methods are being used to obtain detector-independent results. Massive amounts of data and information available. Substantial analysis has been completed for both critical and subcritical configurations. Work in progress is largely novel research and will result in several conference proceedings, journal publications, and a subcritical benchmark. There is still a large amount of data that has not been analyzed and much more to come from the analysis of the Measurements of Uranium Subcritical and Critical.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for ground-state electron capture of K 40

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches—including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for potassium-40, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The existence of this decay mode impacts several fields, while theoretical predictions span an order of magnitude. Here we report on the first, successful observation of this rare decay mode, obtained by the KDK (potassium decay) Collaboration using a novel combination of a low-threshold x-ray detector surrounded by a tonne-scale, high-efficiency γ -ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ( I EC 0 ) over excited-state ones ( I EC * ) of I EC 0 / I EC * = 0.0095 ± stat 0.0022 ± sys 0.0010 (68% CL), with the null hypothesis rejected at 4 σ [Stukel et al. , Phys. Rev. Lett. 131 , 052503 (2023) ]. In terms of branching ratio, this unambiguous signal yields I EC 0 = 0.098 % ± stat 0.023 % ± sys 0.010 % , roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves our understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. For example, a shell-model based theoretical estimate for the neutrinoless double-beta decay half-life of calcium-48 is increased by a factor of 7 - 2 + 3 . Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exotic Dark Matter Search with the Majorana Demonstrator

With excellent energy resolution and ultralow-level radiogenic backgrounds, the high-purity germanium detectors in the enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos ν s → ν a . We report new limits on fermionic dark matter absorption ( χ + A → ν + A ) and sub-GeV DM-nucleus 3 → 2 scattering ( χ + χ + A → ϕ + A ), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1–100)-keV low-energy region of a 37.5-kg y exposure collected by the between May 2016 and November 2019 using a set of Ge 76 -enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗