Search NASA⌕ Search

SEARCH · Search NASA

Results for “occupant modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Alternative approach to quantum imaginary time evolution

There is increasing interest in quantum algorithms (QAs) that are based on the imaginary time evolution (ITE), a successful classical numerical approach to obtain ground states. However, most of the proposals so far require heavy postprocessing computational steps on a classical computer, such as solving linear equations. Here we provide an alternative approach to implement ITE. A key feature in our approach is the use of an orthogonal basis set: the propagated state is efficiently expressed in terms of orthogonal basis states at every step of the evolution. We argue that the number of basis states needed at those steps to achieve an accurate solution can be kept on the order of n , the number of qubits, by controlling the precision (number of significant digits) and the imaginary time increment. The number of quantum gates per imaginary time step is estimated to be polynomial in n . Additionally, while in many QAs the locality of the Hamiltonian is a key assumption, in our algorithm this restriction is not required. This characteristic of our algorithm renders it useful for studying highly nonlocal systems, such as the occupation-representation nuclear shell model. Here, we illustrate our algorithm through numerical implementation on an IBM quantum simulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraining the galaxy-halo connection of infrared-selected unWISE galaxies with galaxy clustering and galaxy-CMB lensing power spectra

We present the first detailed analysis of the connection between galaxies and their dark matter halos for the unWISE galaxy catalog—a full-sky, infrared-selected sample built from WISE data, containing over 500 million galaxies. Using unWISE galaxy-galaxy autocorrelation and Planck CMB lensing-galaxy cross-correlation measurements down to 10 arcmin angular scales, we constrain the halo occupation distribution (HOD), a model describing how central and satellite galaxies are distributed within dark matter halos, for three unWISE galaxy samples at mean redshifts z ¯ ≈ 0.6 , 1.1, and 1.5, assuming a fixed cosmology at the best-fit Planck Λ CDM values. We constrain the characteristic minimum halo mass to host a central galaxy, M min HOD = 1.8 3 - 1.63 + 0.41 × 10 12 M ⊙ / h , 5.22 - 4.80 + 0.34 × 10 12 M ⊙ / h , 6.60 - 1.11 + 0.30 × 10 13 M ⊙ / h and the mass scale at which one satellite galaxy per halo is found, M 1 ' = 1.1 3 - 0.70 + 0.32 × 10 13 M ⊙ / h , 1.18 - 1.11 + 0.30 × 10 13 M ⊙ / h , 1.23 - 1.17 + 0.14 × 10 14 M ⊙ / h for the unWISE samples at z ¯ ≈ 0.6 , 1.1, and 1.5, respectively. We find that all three samples are dominated by central galaxies, rather than satellites. Using our constrained HOD models, we infer the effective linear galaxy bias for each unWISE sample, and find that it does not evolve as steeply with redshift as found in previous perturbation-theory-based analyses of these galaxies. We discuss possible sources of systematic uncertainty in our results, the most significant of which is the uncertainty on the galaxy redshift distribution. Our HOD constraints provide a detailed, quantitative understanding of how the unWISE galaxies populate the underlying dark matter halo distribution. These constraints will have a direct impact on future studies employing the unWISE galaxies as a cosmological and astrophysical probe, including measurements of ionized gas thermodynamics and dark matter profiles via Sunyaev-Zel’dovich and lensing cross-correlations.

79 ASTRONOMY AND ASTROPHYSICS↗

Precise cosmological constraints from BOSS galaxy clustering with a simulation-based emulator of the wavelet scattering transform

For this study, we perform a reanalysis of the BOSS CMASS DR12 galaxy dataset using a simulation-based emulator for the wavelet scattering transform (WST) coefficients. Moving beyond our previous works, which laid the foundation for the first galaxy clustering application of this estimator, we construct a neural net-based emulator for the cosmological dependence of the WST coefficients and the 2-point correlation function multipoles, trained from the state-of-the-art suite of abacussummit simulations combined with a flexible halo occupation distribution (HOD) galaxy model. In order to confirm the accuracy of our pipeline, we subject it to a series of thorough internal and external mock parameter recovery tests, before applying it to reanalyze the CMASS observations in the redshift range 0.46 < z < 0.57. We find that a joint WST+2-point correlation function likelihood analysis allows us to obtain marginalized 1⁢σ errors on the Λ⁢ CDM parameters that are tighter by a factor of 2.5–6, compared to the 2-point correlation function, and by a factor of 1.4–2.5 compared to the WST-only results. This corresponds to a competitive 0.9%, 2.3% and 1% level of determination for parameters ω c , ⁢σ 8 &n s , respectively, and also to a 0.7% and 2.5% constraint on derived parameters h and ƒ⁡(z)⁢⁢σ 8 ⁡(z), in agreement with the Planck 2018 results. Our results reaffirm the constraining power of the WST and highlight the exciting prospect of employing higher-order statistics in order to fully exploit the power of upcoming stage-IV spectroscopic observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Solar particle event organ doses and dose equivalents for interplanetary crews: variations due to body size

Proper assessments of spacecraft shielding requirements and concomitant estimates of risk to critical body organs of spacecraft crews from energetic space radiation require accurate, quantitative methods of characterizing the compositional changes in these radiation fields as they pass through the spacecraft and overlying tissue. When estimating astronaut radiation organ doses and dose equivalents it is customary to use the Computerized Anatomical Man (CAM) model of human geometry to account for body self-shielding. Usually, the distribution for the 50th percentile man (175 cm height; 70 kg mass) is used. Most male members of the U.S. astronaut corps are taller and nearly all have heights that deviate from the 175 cm mean. In this work, estimates of critical organ doses and dose equivalents for interplanetary crews exposed to an event similar to the October 1989 solar particle event are presented for male body sizes that vary from the 5th to the 95th percentiles. Overall the results suggest that calculations of organ dose and dose equivalent may vary by as much as approximately 15% as body size is varied from the 5th to the 95th percentile in the population used to derive the CAM model data. c2002 Published by Elsevier Science Ltd on behalf of COSPAR.

NASA Discipline Radiation Health↗

Monte Carlo mixture model of lifetime cancer incidence risk from radiation exposure on shuttle and international space station

Estimating uncertainty in lifetime cancer risk for human exposure to space radiation is a unique challenge. Conventional risk assessment with low-linear-energy-transfer (LET)-based risk from Japanese atomic bomb survivor studies may be inappropriate for relativistic protons and nuclei in space due to track structure effects. This paper develops a Monte Carlo mixture model (MCMM) for transferring additive, National Institutes of Health multiplicative, and multiplicative excess cancer incidence risks based on Japanese atomic bomb survivor data to determine excess incidence risk for various US astronaut exposure profiles. The MCMM serves as an anchor point for future risk projection methods involving biophysical models of DNA damage from space radiation. Lifetime incidence risks of radiation-induced cancer for the MCMM based on low-LET Japanese data for nonleukemia (all cancers except leukemia) were 2.77 (90% confidence limit, 0.75-11.34) for males exposed to 1 Sv at age 45 and 2.20 (90% confidence limit, 0.59-10.12) for males exposed at age 55. For females, mixture model risks for nonleukemia exposed separately to 1 Sv at ages of 45 and 55 were 2.98 (90% confidence limit, 0.90-11.70) and 2.44 (90% confidence limit, 0.70-10.30), respectively. Risks for high-LET 200 MeV protons (LET=0.45 keV/micrometer), 1 MeV alpha-particles (LET=100 keV/micrometer), and 600 MeV iron particles (LET=180 keV/micrometer) were scored on a per particle basis by determining the particle fluence required for an average of one particle per cell nucleus of area 100 micrometer(2). Lifetime risk per proton was 2.68x10(-2)% (90% confidence limit, 0.79x10(-3)%-0. 514x10(-2)%). For alpha-particles, lifetime risk was 14.2% (90% confidence limit, 2.5%-31.2%). Conversely, lifetime risk per iron particle was 23.7% (90% confidence limit, 4.5%-53.0%). Uncertainty in the DDREF for high-LET particles may be less than that for low-LET radiation because typically there is very little dose-rate dependence. Probability density functions for high-LET radiation quality and dose-rate may be preferable to conventional risk assessment approaches. Nuclear reactions and track structure effects in tissue may not be properly estimated by existing data using in vitro models for estimating RBEs. The method used here is being extended to estimate uncertainty in spacecraft shielding effectiveness in various space radiation environments.

NASA Center LaRC↗

Validation of the 5th and 95th Percentile Hybrid III Anthropomorphic Test Device Finite Element Model

NASA spacecraft design requirements for occupant protection are a combination of the Brinkley criteria and injury metrics extracted from anthropomorphic test devices (ATD's). For the ATD injury metrics, the requirements specify the use of the 5th percentile female Hybrid III and the 95th percentile male Hybrid III. Furthermore, each of these ATD's is required to be fitted with an articulating pelvis and a straight spine. The articulating pelvis is necessary for the ATD to fit into spacecraft seats, while the straight spine is required as injury metrics for vertical accelerations are better defined for this configuration. The requirements require that physical testing be performed with both ATD's to demonstrate compliance. Before compliance testing can be conducted, extensive modeling and simulation are required to determine appropriate test conditions, simulate conditions not feasible for testing, and assess design features to better ensure compliance testing is successful. While finite element (FE) models are currently available for many of the physical ATD's, currently there are no complete models for either the 5th percentile female or the 95th percentile male Hybrid III with a straight spine and articulating pelvis. The purpose of this work is to assess the accuracy of the existing Livermore Software Technology Corporation's FE models of the 5th and 95th percentile ATD's. To perform this assessment, a series of tests will be performed at Wright Patterson Air Force Research Lab using their horizontal impact accelerator sled test facility. The ATD's will be placed in the Orion seat with a modified-advanced-crew-escape-system (MACES) pressure suit and helmet, and driven with loadings similar to what is expected for the actual Orion vehicle during landing, launch abort, and chute deployment. Test data will be compared to analytical predictions and modelling uncertainty factors will be determined for each injury metric. Additionally, the test data will be used to further improve the FE model, particularly in the areas of the ATD neck components, harness, and suit and helmet effects.

Lawrence, C.↗

Basis for the ICRP’s updated biokinetic model for systemic astatine

The International Commission on Radiological Protection (ICRP) recently updated its biokinetic models for workers in a series of reports called the OIR (occupational intakes of radionuclides) series. A new biokinetic model for astatine (At), the heaviest member of the halogen family, was adopted in OIR Part 5 (ICRP in press). Occupational intakes of radionuclides: Part 5). Furthermore, this paper provides an overview of available biokinetic data for At; describes the basis for the ICRP's updated model for At; and tabulates dose coefficients for intravenous injection of each of the two longest lived and most important At isotopes, 211 At and 210 At. At-211 (T 1/2 = 7.214 h) is a promising radionuclide for use in targeted α-particle therapy due to several favourable properties including its half-life and the absence of progeny that could deliver significant radiation doses outside the region of α-particle therapy. At-210 (T 1/2 = 8.1 h) is an impurity generated in the production of 211 At in a cyclotron and represents a potential radiation hazard via its long-lived progeny 210 Po (T 1/2 = 138 days). Tissue dose coefficients for injected 210 At and 211 At based on the updated model are shown to differ considerably from values based on the ICRP's previous model for At, particularly for the thyroid, stomach wall, salivary glands, lungs, spleen, and kidneys.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of the DNAS framework expansion to occupant population synthesis

Research in occupant behaviour is now using a more elaborate framework of building occupant interaction. Researchers often face challenges in collecting data, particularly for the data to meet the minimum number of required data points and the data interoperability requirements. Researchers address the first issue with the synthetic population and the latter with data ontologies. While synthetic population is commonly used to address the first issue, data ontology development is used to address the latter. The two solutions are complementary to each other. One of the known ontologies in building occupant behaviour research is the Drivers-Needs-Actions-Systems (DNAS) ontology, which has been used by building modelers to describe energy-related occupant behaviour. This paper describes the ontology-based synthetic population generation that can be used in the agent-based modeling (ABM) applications. This paper considers multiple data sources, including ASHRAE Thermal Comfort DB II and IEA Annex 66 data sets. A case study of an office building is used to present the workflow of DNAS framework expansion, synthetic population generation, and agent-based modeling.

Chandra Putra, Handi↗

Occupant thermal comfort inference using body shape information

Occupant thermal comfort may be inferred and improved using body shape information. Height, weight, and shoulder circumference of an occupant of a room may be obtained using a depth sensor. A model may be utilized that is trained on a dataset including information reflecting of occupant comfort within the room versus temperature, the model receiving, as inputs, the height, the weight, and the shoulder circumference of the occupant and environmental information and outputting a comfort class. A temperature set-point for is identified which the room occupant is identified by the model as having the comfort class being indicative of user comfort. Heating, ventilation, and air conditioning (HVAC) controls are adjusted for the room to the identified temperature set-point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart thermostat data-driven U.S. residential occupancy schedules and development of a U.S. residential occupancy schedule simulator

Occupancy schedule is one of the key inputs in Building Energy Modeling (BEM) to reflect the interaction between buildings and occupants. Over the past decades, standardized occupancy schedules, developed mainly by engineering rule-of-thumb, have been widely used in BEM due to its simplicity and lack of real measured occupancy data. However, the BEM community has recognized their association with uncertainty and reliability in simulation results from BEM. This study introduces representative occupancy schedules in the U.S. residential buildings, derived from a large smart thermostat dataset and time-series K-means clustering, and an open-source tool to generate a stochastic residential occupancy schedule. Over 90,000 residential occupancy schedules were estimated from the ecobee Donate Your Data dataset. Then, the representative occupancy schedules were identified through clustering. This study further investigated the impacts of three parameters (day, house type, and state) on residential occupancy schedules. Then, a tool, the Residential Occupancy Schedule Simulator (ROSS), is developed using the representative occupancy schedules derived in this study. Details of this tool are presented in this paper. In conclusion, the derived representative occupancy schedules and the ROSS tool can help improve the energy modeling of residential buildings.

42 ENGINEERING↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 4.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 4.1. The two most significant changes for HyRAM+ version 4.1 from HyRAM+ version 4.0 are direct incorporation of unconfined overpressure into the QRA calculations and modification of the models for cryogenic liquid flow through an orifice. In QRA mode, the user no longer needs to input peak overpressure and impulse values that were calculated separately; rather, the unconfined overpressure is estimated for the given system inputs, leak size, and occupant location. The orifice flow model now solves for the maximum mass flux through the orifice at constant entropy while conserving energy, which does not require a direct speed of sound calculation. This does not affect the mass flow for all-gaseous releases; the method results in the same speed of sound for choked flow. However, this method does result in a higher (and more realistic) mass flow rate for a given leak size for liquid releases than was previously calculated.

08 HYDROGEN↗

Evaluation of Human and Anthropomorphic Test Device Finite Element Models under Spaceflight Loading Conditions

In an effort to develop occupant protection standards for future multipurpose crew vehicles, the National Aeronautics and Space Administration (NASA) has looked to evaluate the test device for human occupant restraint with the modification kit (THOR‐K) anthropomorphic test device (ATD) in relevant impact test scenarios. With the allowance and support of the National Highway Traffic Safety Administration, NASA has performed a series of sled impact tests on the latest developed THOR‐K ATD. These tests were performed to match test conditions from human volunteer data previously collected by the U.S. Air Force. The objective of this study was to evaluate the THOR‐K finite element (FE) model and the Total HUman Model for Safety (THUMS) FE model with respect to the tests performed. These models were evaluated in spinal and frontal impacts against kinematic and kinetic data recorded in ATD and human testing. Methods: The FE simulations were developed based on recorded pretest ATD/human position and sled acceleration pulses measured during testing. Predicted responses by both human and ATD models were compared to test data recorded under the same impact conditions. The kinematic responses of the models were quantitatively evaluated using the ISO‐metric curve rating system. In addition, ATD injury criteria and human stress/strain data were calculated to evaluate the risk of injury predicted by the ATD and human model, respectively. Results: Preliminary results show well‐correlated response between both FE models and their physical counterparts. In addition, predicted ATD injury criteria and human model stress/strain values are shown to positively relate. Kinematic comparison between human and ATD models indicates promising biofidelic response, although a slightly stiffer response is observed within the ATD. Conclusion: As a compliment to ATD testing, numerical simulation provides efficient means to assess vehicle safety throughout the design process and further improve the design of physical ATDs. The assessment of the THOR‐K and THUMS FE models in a spaceflight testing condition is an essential first step to implementing these models in the computational evaluation of spacecraft occupant safety. Promising results suggest future use of these models in the aerospace field.

Putnam, Jacob P.↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient and assured reinforcement learning-based building HVAC control with heterogeneous expert-guided training

Abstract Building heating, ventilation, and air conditioning (HVAC) systems account for nearly half of building energy consumption and $$20\%$$ of total energy consumption in the US. Their operation is also crucial for ensuring the physical and mental health of building occupants. Compared with traditional model-based HVAC control methods, the recent model-free deep reinforcement learning (DRL) based methods have shown good performance while do not require the development of detailed and costly physical models. However, these model-free DRL approaches often suffer from long training time to reach a good performance, which is a major obstacle for their practical deployment. In this work, we present a systematic approach to accelerate online reinforcement learning for HVAC control by taking full advantage of the knowledge from domain experts in various forms . Specifically, the algorithm stages include learning expert functions from existing abstract physical models and from historical data via offline reinforcement learning, integrating the expert functions with rule-based guidelines, conducting training guided by the integrated expert function and performing policy initialization from distilled expert function. Moreover, to ensure that the learned DRL-based HVAC controller can effectively keep room temperature within the comfortable range for occupants, we design a runtime shielding framework to reduce the temperature violation rate and incorporate the learned controller into it. Experimental results demonstrate up to 8.8 X speedup in DRL training from our approach over previous methods, with low temperature violation rate.

Xu, Shichao↗

Behavioral and Population Data-Driven Distribution System Load Modeling

Distribution system residential load modeling and analysis for different geographic areas within a utility or an independent system operator territory are critical for enabling small-scale, aggregated distributed energy resources to participate in grid services under Federal Energy Regulatory Commission Order No. 2222 [1]. In this study, we develop a methodology of modeling residential load profiles in different geographic areas with a focus on human behavior impact. First, we construct a behavior-based load profile model leveraging state-of-the-art appliance models. We simulate human activity and occupancy using Markov chain Monte Carlo methods calibrated with the American Time Use Survey data set. Second, we link our model with cleaned Current Population Survey data from the U.S. Census Bureau. Finally, we populate two sets of 500 households using California and Texas census data, respectively, to perform an initial analysis of the load in different geographic areas with various group features (e.g., different income levels). To distinguish the effect of population behavior differences on aggregated load, we simulate load profiles for both sets assuming fixed physical household parameters and weather data. Analysis shows that average daily load profiles vary significantly by income and income dependency varies by locality.

American Time Use Survey↗

Quantifying spatiotemporal variability in occupant exposure to an indoor airborne contaminant with an uncertain source location

Well-mixed zone models are often employed to compute indoor air quality and occupant exposures. While effective, a potential downside to assuming instantaneous, perfect mixing is underpredicting exposures to high intermittent concentrations within a room. When such cases are of concern, more spatially resolved models, like computational-fluid dynamics methods, are used for some or all of the zones. But, these models have higher computational costs and require more input information. A preferred compromise would be to continue with a multi-zone modeling approach for all rooms, but with a better assessment of the spatial variability within a room. Here to do so, we present a quantitative method for estimating a room's spatiotemporal variability, based on influential room parameters. Our proposed method disaggregates variability into the variability in a room's average concentration, and the spatial variability within the room relative to that average. This enables a detailed assessment of how variability in particular room parameters impacts the uncertain occupant exposures. To demonstrate the utility of this method, we simulate contaminant dispersion for a variety of possible source locations. We compute breathing-zone exposure during the releasing (source is active) and decaying (source is removed) periods. Using CFD methods, we found after a 30 minutes release the average standard deviation in the spatial distribution of exposure was approximately 28% of the source average exposure, whereas variability in the different average exposures was lower, only 10% of the total average. We also find that although uncertainty in the source location leads to variability in the average magnitude of transient exposure, it does not have a particularly large influence on the spatial distribution during the decaying period, or on the average contaminant removal rate. By systematically characterizing a room's average concentration, its variability, and the spatial variability within the room important insights can be gained as to how much uncertainty is introduced into occupant exposure predictions by assuming a uniform in-room contaminant concentration. We discuss how the results of these characterizations can improve our understanding of the uncertainty in occupant exposures relative to well-mixed models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗