Search NASA⌕ Search

SEARCH · Search NASA

Results for “operational integrated energy system models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

A Hydrogen Load Modeling Method for Integrated Hydrogen Energy System Planning

The integrated hydrogen energy system incorporates hydrogen energy into the power grid, which has been recognized as a promising option for reaching a 100% renewable electricity supply. It can make a profit because the hydrogen produced can be sold as fuel or used to generate electricity for grid services. In this paper, we develop a planning model for the integrated hydrogen energy system that considers the uncertainty of the load demand, the renewable energy generation, and the market prices. To calculate the hydrogen load, we simulate the refueling operations at a hydrogen fueling station over the course of one day and generate representative load profiles with K-means clustering. Moreover, the long-term profitability of the integrated system under both current and future conditions is validated in 10-year planning results.

grid service↗

A Hydrogen Load Modeling Method for Integrated Hydrogen Energy System Planning: Preprint

The integrated hydrogen energy system incorporates hydrogen energy into the power grid, which has been recognized as a promising option for reaching a 100% renewable electricity supply. It can make a profit because the hydrogen produced can be sold as fuel or used to generate electricity for grid services. In this paper, we develop a planning model for the integrated hydrogen energy system that considers the uncertainty of the load demand, the renewable energy generation, and the market prices. To calculate the hydrogen load, we simulate the refueling operations at a hydrogen fueling station over the course of one day. Moreover, the long-term profitability of the integrated system under both cur-rent and future conditions is compared in the planning results.

active distribution network↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Canadian Oil Sands Extraction and Upgrading: A Synthesis of the Data on Energy Consumption, CO 2 Emissions, and Supply Costs

As Canadian crude bitumen production from oil sands has increased in recent decades, the nation’s oil and gas industry has become a significant contributor to national greenhouse gas emissions. Canada has developed carbon emission reduction targets to meet its Nationally Determined Contributions and Mid-Century Strategy goals. A detailed profile of energy consumption pathways in the oil sands industry is necessary to identify potential areas of improvement and to monitor progress toward meeting emissions reduction targets. Much of the existing literature for oil sands modeling provides input assumptions with different technological boundaries. For a set of oil sands extraction and upgrading technologies, this study first reviews the literature and then quantifies energy input requirements, CO 2 emissions, and operating costs for a set of consistent technological boundaries and energy units. Summary results refer to requirements and costs at the production facility, excluding transportation and blending costs. An energy system diagram of oil sands production that matches these boundaries is provided, which can be used by integrated assessment models, oil sands companies, and government ministries to evaluate the present and future energy consumption and emissions pathways of the oil sands industry.

02 PETROLEUM↗

2023 Real-time Optimization Workflow Status Update

Nuclear integrated energy systems are composed of a diverse set of energy generation sources and exist in dynamic and competitive electricity markets. With the inclusion of thermal energy storage, nuclear power systems can store heat for future use through various processes, such as water desalination or hydrogen generation. This heat storage can be managed in such a way as to economically optimize its usage. By combining real-time price data from the day-ahead and real-time markets with predictive and intelligent models, the charging and discharging of the thermal energy storage may be determined and optimized. This research details an approach through models and systems for the real-time optimization (RTO) of capacity allocation. Virtual models of the energy system and its physics phenomenon and component interactions provide intelligence to verification and prediction of operations. An optimization framework can use data generated from both a set of physical assets as well as the virtual models to predict future performance and create optimization and control workflows. Data warehouse technologies can be used to combine data across models, optimization workflows, market price data, and sensor data to intuitively store various types of data and provide integrations to physical control systems as well as user visualizations. Put together, these components can create a system for the RTO of nuclear integrated energy systems. Various virtual models and bench-scale physical demonstrations have been successfully performed and verified using this system. Larger scale testbeds that include thermal energy storage systems have been identified as future opportunities. A gap analysis that details the steps necessary to reach a physical demonstration at this scale is provided, along with conclusions on the current effort and future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

HybridSystemsSimulations.jl - Solving the Merchant Collocated Facilities with JuMP

The development of new clean-generation technologies also leads to new plant-level architectures that combine several generation and storage assets behind the point of connection. These co-located generation resources (Hybrid Systems) primarily operate as merchant assets that employ automated market bidding models and internal Energy Management Systems (EMS) to comply with the operator's signals. Formulating an optimal bidding model requires embedding the EMS control model into the bidding algorithm, resulting in a bi-level optimization problem. In this presentation, we first showcase using JuMP to formulate and solve this problem effectively for multiple merchant systems and the bidding outcomes considering different model formulations. Second, the bidding outcomes are later integrated into a PowerSimulations.jl (also built with JuMP) simulation to study the system-level effects of the various merchant bidding and the interactions between market-clearing models and the embedded EMS model. We will showcase simulations conducted in the RTS system considering different levels of merchant hybrid systems participation. The presentation provides the following specific insights on JuMP usage: 1) the Formulation of specialized bi-level problems with custom cuts to solve the merchant hybrid system bidding problem; 2) the integration of a modular model within a complex simulation workflow supported by JuMP in PowerSimulations.jl; 3) Accelerating the solution of power systems operations simulation that employ agent optimization problems using JuMP.

energy markets↗

Quantitative Metrics for Grid Resilience Evaluation and Optimization

Power system resilience has become a critical topic in recent years because of the increasing trend of extreme events and the growing integration of intermittent renewable energy sources. To enhance grid resilience against high-impact, low-frequency events, two questions should be answered: how to quantify the resilience of a given grid and how to incorporate the quantification into power system planning, operation, and restoration. Here this paper develops a new set of quantitative metrics with clear physical interpretation to comprehensively evaluate power system resilience. Using microgrids as an example, an event-based corrective scheduling (ECS) model and an online model predictive control (OMPC) model are developed to integrate the proposed quantitative resilience metrics into power system optimization models for resilience enhancement. The ECS model employs extreme event data to investigate the optimal restoration solution and to help microgrid operators prepare to respond to similar events. The OMPC model provides online decision-making support for operators to handle ongoing outages in the most resilient fashion. The effectiveness and superiority of the proposed quantitative resilience metrics and the resilience enhancement models are demonstrated through simulations and comparative studies on an IEEE test feeder and a real distribution feeder in Southern California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear-Renewable-Storage Systems: Enhancing Planning and Operations of Integrated Energy Systems

Nuclear-renewable-storage integrated energy systems (IES) are multi-carrier energy systems that include not only electricity but also other forms of demands. Because individual IES components must observe their thermo-physical limits, including ramp rates, start-up, and shut-down time, we formulate operations of the IES as an optimization model by minimizing the total operations costs subject to physical limits of all constituent components. In addition, we develop a data-driven approach to improve the computational performance of the economic dispatch model by using reinforcement learning, where an agent is rewarded by meeting demands and penalized otherwise when shifting to the next state.

25 ENERGY STORAGE↗

Flexible Nuclear Energy for Clean Energy Systems

As part of the Nuclear Innovation: Clean Energy Future initiative, this report describes flexibility in nuclear systems, the value it can bring, and international experiences surrounding flexible nuclear energy. Flexible nuclear energy for this report is defined as “The ability of nuclear energy generation to economically provide energy services at the time and location they are needed by end-users. These energy services can include both electric and non-electric applications utilizing both traditional nuclear power plants and advanced integrated systems.” Flexibility in nuclear systems is enabled by three main mechanisms: core ramping, integrated energy systems with multiple byproducts, and thermal storage. The value of this flexibility on a $\$$/MW and a $\$$/MWh basis can be estimated through a combination of physics and economics modeling. International agencies describe their experiences in operating flexible nuclear systems and describe their plans for increasing nuclear flexibility in a clean energy system, likely with a high penetration of variable renewable energy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstrate FARM supervisory capabilities for a thermal energy storage problem for the DETAIL facility: IES Simulation Ecosystem Control System Development

The goal of the power dispatch problem for an Integrated Energy System (IES) is to adjust the power output and the heat flow of each component to maximize the profitability of the whole unit. Facilities that can integrate real-time digital signals, mock nuclear power, thermal energy storage and industrial heat use via high-temperature electrolysis were constructed at INL to support the research activities. The Dynamic Energy Technology and Integration Laboratory (DETAIL) houses the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET) and the Thermal Energy Distribution System (TEDS). In this report, the hierarchical control system architecture proposed in June 2023 milestone for the flexible operation of DETAIL facility is finalized and demonstrated. A brief description of the components and the corresponding Dymola models from the HYRBID repository is first provided. Then, the current control strategy is presented. In particular, the approach for generating the set-point trajectories to be fed to the PI controllers is analyzed, and its limits were identified. To preserve safe operation over both long-time and real-time horizons, the integration of a Supervisory Control layer embedding a modified version of FARM (Feasible Actuator Range Modifier) module is proposed. FARM is a component of the RAVEN-based FORCE framework designed to support HERON module at optimizing the operation of IES units. The proposed control system for DETAIL foresees FARM to be applied twice, i.e., the original version (“FARM-Validator”) aiding the solution of the power dispatch problem, and a modified version (“FARM-Supervisory”) coordinating the PID controllers. Despite the kernel of the two modules is the same, their tasks are quite different. The former intervenes at the beginning of each hour to prevent constraint violations over long time periods, the latter addresses real-time control tasks and monitors the response of constrained variables at a much finer time resolution. A tentative procedure for training the embedded Digital Twins with the experimental data is also proposed. Finally, the capabilities of the designed architecture and the impact of the added Supervisory Control layer are demonstrated by simulating a representative power dispatch scenario.

25 ENERGY STORAGE↗

Challenges and Opportunities for Electric Utility Modeling and Asset Valuation Frameworks: Case Study on Valuing New Pumped Storage Hydropower

Asset valuation by electric utilities is becoming increasingly difficult in the rapidly changing electric sector. Rapid deployment of variable generation and inverter-based storage systems along with uncertain demand growth, climate, policies, and other factors create a challenging environment for understanding the value proposition of a new potential asset. This report describes an effort between the Tennessee Valley Authority (TVA) and three U.S. Department of Energy laboratories to perform a detailed review of utility modeling and analysis practices for asset valuation and identify challenges and opportunities for advancing its methods into the future. It focuses on a case study of new potential pumped storage hydropower (PSH) because of growing interest in new PSH capacity to provide energy balancing, firm capacity, and a range of ancillary services. Staff from the DOE labs conducted systematic interviews about current practices in capacity expansion modeling, production-cost modeling, hydrological modeling, and transmission stability modeling while also discussing how scenario analysis is conducted and how models and data are integrated. The effort resulted in a set of model, integration, and scenario recommendations that could be valuable to TVA, other utilities, system operators, and other stakeholders conducting integrated grid analysis. Individual model recommendations suggest exploring computational tradeoffs with detail and resolution across spatiotemporal structure, supply- and demand-side details, transmission overlays, market interactions, and ancillary services. Automated processes to pass data between models and conduct larger scenario suites could also enhance valuation practices by enabling a more consistent study of asset value across a broader range of uncertain future grid conditions where PSH could be particularly valuable. TVA and other industry stakeholders can learn from and adapt applied research-grade methods developed by DOE laboratories and other research institutions to improve decision making and accelerate progress towards a reliable, economic, sustainable energy system.

13 HYDRO ENERGY↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗

Conceptual Design of Integrated Energy Systems with Market Interaction Surrogate Models

Most integrated energy system (IES) optimization frameworks employ the price-taker approximation, which ignores important interactions with the market and can result in overestimated economic values. In this work, we propose a machine learning surrogate-assisted optimization framework to quantify IES/market interactions and thus go beyond price-taker. We use time series clustering to generate representative IES operation profiles for the optimization problem and use machine learning surrogate models to predict the IES/market interaction. We quantify the accuracy of the time series clustering and surrogate models in a case study to optimally retrofit a nuclear power plant with a polymer electrolyte membrane electrolyzer to co-produce electricity and hydrogen.

Chen, Xinhe↗

Multibody for Everybody (M4E) - A Linearization Approach to Enable Frequency Domain Analysis, Time Integration and Control Co-Design

1.1 Background/Objectives: Marine energy represents a promising yet underexploited source of power. To increase the harvested power, significant efforts have been made to improve wave energy converter (WEC) modeling capabilities and optimize power take-off (PTO) performance; however, these efforts have often treated WEC dynamics, PTO design, and controller development sequentially. In contrast, control co-design (CCD) is emerging as a promising strategy to address these issues directly, creating a growing need for fast analysis tools suitable for repeated simulation and parametric studies [1]. To support this need, this work presents the Multibody for Everybody (M4E) [2] linearization module, which employs a symbolic toolbox to provide deeper insight of WEC design parameters. The objective is to demonstrate that a minimal-coordinate linearization of articulated WEC dynamics can provide accurate wave response predictions and substantial computational savings relative to nonlinear time-domain simulation, while preserving compatibility with broader wave-energy analysis workflows, enabling CCD. 1.2 Approach/Activities: The proposed approach linearizes the equations of motion, generated by M4E, in minimal coordinates about a selected operating point and combines the resulting system with frequencydomain hydrodynamic terms to incorporate the reduced mass, damping, stiffness, and forcing operators. The linearized model is used for both impedance-based response amplitude operator (RAO) prediction and rapid regular-wave time integration. The methodology is demonstrated on a single-flap device and a FOSWEC configuration, with linearized M4E responses compared against the corresponding nonlinear M4E simulations and WEC-Sim results. Regular-wave time histories, RAO trends, and runtime differences are assessed. The framework is also compatible with broader wave-energy workflows, including coupling to WecOptTool, although that capability is not the focus of this work [3]. 1.3 Results/Lessons: The linearized M4E model reproduces key regularwave response characteristics such as integration and Response Amplitude over multiple frequencies. This module matches nonlinear M4E and WEC-Sim results while substantially reducing integration cost. Thus, the proposed framework can serve as a rapid analysis layer for articulated WEC design, parameter studies, and controls-oriented workflows. The analysis is most appropriate in the near-equilibrium regime, about the linearization point.

16 TIDAL AND WAVE POWER↗

Transient Physical Modelling for the Coupling of a High Temperature Gas Reactor with Thermal Energy Storage

Improving the flexibility of nuclear reactors to meet fluctuating demand on grids with high renewable energy generation penetration is key to improving reactor economics. Economic optimization using the code HERON gives maximum profit of coupling high temperature gas reactors (HTGRs) to thermal energy storage (TES) systems in the configuration shown in Figure 1 when following the demand in Figure 3. We look to model the physics of operation for a HTGR-TES using the HYBRID library in the code Modelica.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗