Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical signals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

A 10-Gb/s Driver/Receiver ASIC and Optical Modules for Particle Physics Experiments

We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated silicon optical amplifier with reduced residual pump

An optical amplifier device employing a Mach-Zehnder Interferometer (MZI) that reduces the amount of residual pump power in the optical output of the amplifier is disclosed. The MZI amplifier employs two geometrically linear optical amplifier arms or two multi-spatial-mode racetrack optical amplifiers to amplify a signal with a pumping beam, with the signal output port having extremely low levels of residual pump power. The MZI optical amplifier is a silicon photonic integrated circuit, with all optical amplifiers, couplers, phase shifters, and optical attenuators formed of silicon photonic integrated circuit elements. The MZI optical amplifier may include one, two, or three MZI stages, and multiple MZI optical amplifiers may be used in parallel or sequentially to achieve higher overall signal gain or power. The MZI optical amplifier may employ Brillouin-scattering-based amplifiers, Raman-based integrated waveguide optical amplifiers, or Erbium-doped integrated waveguide optical amplifiers.

Lentine, Anthony L.↗

Spatially enhanced electric field induced second harmonic (SEEFISH) generation for measurements of electric field distributions in high-pressure plasmas

Abstract The spatial resolution of the ps electric field induced second harmonic (EFISH) generation has been enhanced by using non-collinear pump laser beam arrangements. The pump laser beam (1064 nm, nominal pulse duration 150 ps, pulse energy 20–40 mJ) is separated into two coaxial or crossing beams, overlapping only near the focal point. The spatially enhanced EFISH (SEEFISH) signal is generated over a shorter beam overlap region compared to the collinear beam arrangement. Blocking of either of the two beams results in a complete suppression of the signal. The signal is spatially isolated from the ‘conventional’ EFISH signal and measured by a photomultiplier detector. Measurements of a known Laplacian field generated between two parallel cylinder electrodes in ambient air shows that SEEFISH improves the spatial resolution of the measurements by up to a factor of 2, such that the measurement results agree with the Laplacian field distribution. The spatial resolution is improved further by reducing the focal distance of the lens. The magnitude of the SEEFISH signal is significantly lower compared to that of the single-beam EFISH and decreases rapidly as the beam crossing angle is increased, due to the phase mismatch. This approach has a significant potential for measurements of electric field distributions in high-pressure plasmas, with an additional benefit of removing the stray second harmonic signal from the optical access windows.

Physics↗

Photocurrent Nanoscopy of Quantum Hall Bulk

Understanding nanoscale electronic and thermal transport of two-dimensional (2D) electron systems in the quantum Hall regime, particularly in the bulk insulating state, poses considerable challenges. One of the primary difficulties arises from the presence of chiral edge channels, whose transport behavior obscures the investigation of the insulating bulk. Using near-field optical and photocurrent nanoscopy, we probe real-space variations of the optical and thermal dynamics of graphene in the quantum Hall regime without relying on complex sample or electrode geometries. Near the charge-neutrality point, we detect strong optical and photothermal signals from resonant inter-Landau-level (LL) magnetoexciton excitations between the zeroth and ± 1 st LLs, which gradually weaken with increasing doping due to Pauli blocking. Interestingly, at higher doping levels and full-integer LL fillings, photothermal signals reappear across the entire sample over an approximately 10 − μ m scale, indicating unexpectedly long cooling lengths and nonlocal photothermal heating through the insulating bulk. This observation suggests that thermal conductivity persists for the localized states even as electronic transport is suppressed—a clear violation of the Wiedemann-Franz law. Our experiments provide novel insights into nanoscale thermal and electronic transport in incompressible 2D gases, highlighting the roles of magnetoexcitons and chiral edge states in the thermo-optoelectric dynamics of the Dirac quantum Hall state. Published by the American Physical Society 2025

36 MATERIALS SCIENCE↗

High Energy Cooling

The paper considers methods of particle cooling applicable to beam cooling in high energy hadron colliders at the collision energy. Presently, there are two major methods of the cooling the electron cooling and stochastic cooling. The later, in application to colliders, requires exceptionally large frequency band of cooling system. Presently two methods are considered. They are the optical stochastic cooling (OSC) and the coherent electron cooling (CEC). OSC and CEC are essentially extensions of microwave stochastic cooling, operating in 1-10 GHz frequency range, to the optical frequencies enabling bands up to 30-300 THz. The OSC uses undulators as a pickup and a kicker, and an optical amplifier for signal amplification, while the CEC uses an electron beam for all these functions. We discuss major limitations, advantages and disadvantages of electron and stochastic cooling systems.

43 PARTICLE ACCELERATORS↗

Study of shortwave spectra in fully 3D environment: synergy between scanning radars and spectral radiation measurements (final Report)

Overview of 3D atmospheric radiative transfer in cloudy atmosphere for Reports on Progress in Physics. We surveyed the 3D atmospheric radiative transfer literature over the past 50 years and identify three concurrent and intertwining themes: first, how to assess the damage (bias) caused by 3D effects in the operational 1D radiative transfer models? Second, how to mitigate this damage? Third, can we exploit 3D radiative transfer phenomena to invent new observation methods and technologies? Two equally important application areas for atmospheric radiative transfer in general, and 3D in particular, were identified: broadband radiative energy budget estimation and wavelength-specific optical remote sensing signal modeling. As illustrations, both satellite and ARM observations were highly used.

54 ENVIRONMENTAL SCIENCES↗

Temporal resolution and fidelity enhancement of arbitrary waveforms

Apparatuses comprising cascaded or series configurations of Mach-Zehnder electrooptic modulators, where the nonlinearities of the cascaded and series configurations of Mach-Zehnder electrooptic modulators increase signal bandwidth and boost signal fidelity in electronic digital to analog converters. The Mach-Zehnder electrooptic modulators are combined with photodiode detectors that are used to convert signals from the optical domain to the electrical domain.

Muir, Ryan D.↗

Selective Enhancement of Spectroscopic Features by Quantum Optimal Control

Tailored light can be used to steer atomic motions into selected quantum pathways. In optimal control theory (OCT), the target is usually expressed in terms of the molecular wave function, a quantity that is not directly observable in experiment. In this study, we present simulations using OCT that optimize the spectroscopic signal itself. By shaping the optical pump, the x-ray stimulated Raman signal, which occurs solely during the passage through conical intersections, is temporally controlled and amplified by up to 2 orders of magnitude. This enhancement can be crucial in order to bring small coherence-based signatures above the detectable threshold. Our approach is applicable to any signal that depends on the expectation value of a positive definite operator.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dual-Color Optical Recording of Bioelectric Potentials by Polymer Electrochromism

Optical recording based on voltage-sensitive fluorescent reporters allows for spatial flexibility of measuring from desired cells, but photobleaching and phototoxicity of the fluorescent labels often limit their sensitivity and recording duration. Voltage-dependent optical absorption, rather than fluorescence, of electrochromic materials, would overcome these limitations to achieve long-term optical recording of bioelectrical signals. Electrochromic materials such as PEDOT:PSS possess the property that an applied voltage can either increase or decrease the light absorption depending on the wavelength. In this work, we harness this anticorrelated light absorption at two different wavelengths to significantly improve the signal detection. With dual-color detection, electrical activity from cells produces signals of opposite polarity, while artifacts, mechanical motions, and technical noises are uncorrelated or positively correlated. Using this technique, we are able to optically record cardiac action potentials with a high signal-to-noise ratio, 10 kHz sampling rate, >15 min recording duration, and no time-dependent degradation of the signal. Furthermore, we can reliably perform multiple recording sessions from the same culture for over 25 days.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Analysis of pump-to-signal noise transfer in two-stage ultra-broadband optical parametric chirped-pulse amplification

In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam.

47 OTHER INSTRUMENTATION↗

Impact of the optical parametric amplification phase on laser pulse compression

Optical parametric chirped-pulse amplification (OPCPA) is an effective way to generate ultrashort pulses that has been used extensively for a variety of applications requiring high peak intensities. Precise control and measurement of a system’s spectral and spatial phases are required for Fourier transform–limited pulse compression and diffraction-limited focusing. Phase accumulated during optical parametric amplification (OPA) can degrade the compressibility and focusability of the pulse, reducing peak intensity. We used analytic and numerical analysis of OPA to study the influence of crystal parameters, wavefront of the pump and signal, and their relative optical alignment on the accumulated phase. Here, we show that the accumulated signal phase is largely independent of amplifier saturation and, with significant local wavefront gradients in the signal or pump beam, the quality of the compressed pulses can be degraded. We use first-order expressions for the pump- and signal-angle sensitivity to evaluate an OPCPA system consisting of a highly deuterated potassium dihydrogen phosphate (DKDP) amplifier designed to support bandwidth for 15 fs pulses centered at 920 nm.

47 OTHER INSTRUMENTATION↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Testing of the Address in Real-Time Data Driver Card for the Micromegas Detector of the ATLAS New Small Wheel Upgrade

The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data in the Micro-Mesh Gaseous Structure (Micromegas) detector of the ATLAS New Small Wheel (NSW) upgrade. The Address in Real Time (ART) signals are generated by the front-end ASIC, named VMM chip, to indicate the address of the first above-threshold event. A custom ASIC (ART ASIC) is designed to receive the ART signals from the VMM chip and implement the hit-selection. The processed data from the ART ASIC will be transmitted out of the NSW through the GBTx serializer, the unidirectional Versatile Twin Transmitter (VTTx) and fiber optical links. The ART signal is critical for the ATLAS experiment trigger selection thus the performance and stability of the ADDC is very important. To ensure extensive testing of the ADDC, an FPGA Mezzanine Card (FMC) based testing platform and a special designed firmware/software are developed. We find that this test platform works with the commercial Xilinx VC707 FPGA development kit, independent of the other electronics of the NSW it can test all the functions of the ADDC and its long-term stability. This paper will introduce the design, testing procedure and results of the ADDC and the FMC testing platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intelligent Monitoring System for Real-time Geologic Storage, Optimization, and Reservoir Management

The objective of the subtask was to develop a near-real-time monitoring system for seismic data at the Decatur, IL, geologic carbon sequestration (GCS) site and specifically include fiber-optic cable derived distributed acoustic signal (DAS) data in the process. Owing to the large volumes of data, we opted to utilize existing deep borehole conventional seismic sensors for detection and pull DAS and shallow borehole seismic data once a detection has been made. Unfortunately, the horizontal fiber-optic cables did not yield microseismic signals for use in locating events near the GCS site. Various stacking and filtering approaches were tested without any coherent detection becoming apparent. We attribute the insensitivity to local microseismic events to a lack of coupling in downhole, vertical cable and the non-ideal alignment of the horizontal fiber-optic cable to the vertically polarized seismic energy. Despite the inability to detect and utilize the DAS data from the fiber-optic cables, we developed a general processing framework that enables easy adaptation for future deployment of fiber-optic cables with better suited alignment at Decatur or elsewhere.

Kaven, J. Ole↗