Diel cycle impacts on the chemical and light absorption properties of organic carbon aerosol from wildfires in the western United States

Abstract. Organic aerosol (OA) emissions from biomass burning have been the subject of intense research in recent years, involving a combination of field campaigns and laboratory studies. These efforts have aimed at improving our limited understanding of the diverse processes and pathways involved in the atmospheric processing and evolution of OA properties, culminating in their accurate parameterizations in climate and chemical transport models. To bring closure between laboratory and field studies, wildfire plumes in the western United States were sampled and characterized for their chemical and optical properties during the ground-based segment of the 2019 Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) field campaign. Using a custom-developed multiwavelength integrated photoacoustic-nephelometer spectrometer in conjunction with a suite of instruments, including an oxidation flow reactor equipped to generate hydroxyl (OH⚫) or nitrate (NO3⚫) radicals to mimic daytime or nighttime oxidative aging processes, we investigated the effects of multiple equivalent hours of OH⚫ or NO3⚫ exposure on the chemical composition and mass absorption cross-sections (MAC(λ)) at 488 and 561 nm of OA emitted from wildfires in Arizona and Oregon. We found that OH⚫ exposure induced a slight initial increase in absorption corresponding to short timescales; however, at longer timescales, the wavelength-dependent MAC(λ) decreased by a factor of 0.72 ± 0.08, consistent with previous laboratory studies and reports of photobleaching. On the other hand, NO3⚫ exposure increased MAC(λ) by a factor of up to 1.69 ± 0.38. We also noted some sensitivity of aerosol aging to different fire conditions between Arizona and Oregon. The MAC(λ) enhancement following NO3⚫ exposure was found to correlate with an enhancement in CHO1N and CHOgt1N ion families measured by an Aerodyne aerosol mass spectrometer.

54 ENVIRONMENTAL SCIENCES↗

Quantitative infrared spectroscopy of aerosols: Mie theory modeling with experimental validation

Infrared spectroscopy is a well-established method for identifying solid, liquid, and gas-phase chemicals. Accurate infrared spectroscopic analysis requires reference libraries where library endmembers reflect all optical phenomena contributing to the observed spectra. Traditional spectral libraries most often contain molecular-based absorption spectra, but these do not account for the complex scattering effects that become significant when measuring aerosols. In this work, we combine the laboratory-derived, wavelength-dependent complex optical vectors ( n / k ) of liquid dioctyl sebacate (DOS) with Mie scattering theory and the Beer–Lambert law to generate synthetic infrared transmission spectra of aerosolized DOS. Additionally, we record experimental infrared transmission spectra using an FTIR spectrometer coupled to a simple aerosol chamber filled with a quantified number size distribution of aerosolized DOS. The modeled and measured spectra show strong agreement, with Mie scattering effects clearly altering the overall spectral shape as well as the positions and profiles of absorption features. The results demonstrate that synthetic spectra generated from n / k values can reliably capture aerosol-specific spectral behavior and thus serve as a foundation for building scalable, physics-based aerosol reference libraries to enable infrared spectroscopic detection of aerosols.

Salcido, Jessica M. O. [Pacific Northwest National↗

EPCAPE-PT-LANL Measurements: Proton Transfer Reaction Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: IONICON High-Resolution PTR-TOF-MS - Trace VOC Analyzer. Concentrations were calculated based on theoretical reaction rates of each species with H3O+. Details of the calculation are found in the PTR-MS Ionicon Manual. Data Notes: It is a high-resolution PTR-TOF-MS we have sub-selected relevant species. Contact us if you want additional data products from this instrument. Header: - CalculatedAcetonitrile[ppbv]: The concentration of acetonitrile expressed in parts per billion by volume (ppbv). - CalculatedAcetaldehyde[ppbv]: The concentration of acetaldehyde expressed in parts per billion by volume (ppbv). - CalculatedAcetone[ppbv]: The concentration of acetone expressed in parts per billion by volume (ppbv). - CalculatedAceticAcid[ppbv]: The concentration of acetic acid expressed in parts per billion by volume (ppbv). - CalculatedIsoprene[ppbv]: The concentration of isoprene expressed in parts per billion by volume (ppbv). - CalculatedMVK[ppbv]: The concentration of methyl vinyl ketone (MVK) and methacrolein (MACR) expressed in parts per billion by volume (ppbv). - CalculatedMEK[ppbv]: The concentration of methyl ethyl ketone (MEK) expressed in parts per billion by volume (ppbv). - CalculatedBenzene[ppbv]: The concentration of benzene expressed in parts per billion by volume (ppbv). - CalculatedToluene[ppbv]: The concentration of toluene expressed in parts per billion by volume (ppbv).

54 ENVIRONMENTAL SCIENCES↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

Multichannel angular spectrometer

A multichannel angular spectrometer includes an array of fiber pickups having an arcuate arrangement and focused about a sample volume. A broadband light source is configured to illuminate a sample within the sample volume. At least one dispersion element is in optical communication with the array of fiber pickups. An imaging sensor is in optical communication with the array of fiber pickups. The imaging sensor is configured to image the broadband light received by the array of fiber pickups and dispersed by the at least one dispersion element. A processor is in electrical communication with the imaging sensor. The processor has a power supply and computer-readable memory.

47 OTHER INSTRUMENTATION↗

Measurement of the Neutron Electromagnetic Form Factors at High Momentum Transfer Using a Polarized 3He Target at Jefferson Lab

Ever since the composite structure of nucleons was uncovered, many experiments have been commissioned with the purpose of extracting parameters that shape our understanding of this structure. Form factors are powerful tools that rest at the forefront of the nucleon structure study. In the non-relativistic limit, they describe the magnetic and charge distributions inside the nucleon. The GEn-II experiment, which ran in Hall A of Jefferson Lab as a part of the SuperBigbite Spectrometer (SBS) program, aimed to extract the ratio of the neutron’s electric to magnetic Sachs form factors (GnE/GnM. This was accomplished using the double polarization technique: scattering polarized electrons with initial energies up to 8.45 GeV off high-density polarized 3He targets. The experiment was a coincidence measurement, with the scattered electrons detected in the BigBite Spectrometer and the recoil nucleons in a hadron calorimeter, a part of the SuperBigbite Spectrometer. The convection-style target cells used in this experiment have a 60cm long target chamber, an increase from the 40 cm cell used in the most recent polarized 3He target experiment. In addition, the cells were optically pumped from two sides of the pumping chamber. These improvements in design and functionality introduced world-record-breaking luminosity. This thesis presents preliminary results of the GEn-II experiment for the following 4-momentum transfer (Q2) values: 2.93, 6.76, and 9.78 GeV2, in addition to target performance and preliminary polarimetry results.

Presley, Hunter [Univ. of Virginia, Charlottesvill↗

S. elongatus PCC 7942 Carbon Metabolism Proteomics (MC-DP2)

The purpose of this experiment was to examine the redox proteome of S. elongatus PCC 7942 CscB/SPS under different light conditions (light and dark) and culture conditions (dense and dilute optical density). Samples were processed using a resin-assisted capture (RAC) workflow with TMT labeling to enrich and quantify protein cysteines which were differentially oxidized under four conditions. The datasets were generated by a Q Exactive Plus Orbitrap Mass Spectrometer coupled with a Waters nanoAcquity UPLC, then searched by MSGF+ for downstream redox PTM analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Single-shot local measurement of terahertz correlated second harmonic generation in laser air plasma filaments

We present a single-shot detection method of terahertz correlated second harmonic generation in plasma-based sources by directly mixing an optical probe into femtosecond laser-induced plasma filaments in air. Furthermore, the single-shot second harmonic trace is obtained by measuring a second harmonic generation on a conventional CCD with a spatiotemporally distorted probe beam. The system shows a spectrometer resolution of 22 fs/pixel on the CCD and a true resolution on the order of the probe pulse duration. With considerable THz peak electric field strength, this formalism can open the door to single-shot THz detection without bandwidth limitations.

47 OTHER INSTRUMENTATION↗

On-chip spectrometers using stratified waveguide filters

We present an ultra-compact single-shot spectrometer on silicon platform for sparse spectrum reconstruction. It consists of 32 stratified waveguide filters (SWFs) with diverse transmission spectra for sampling the unknown spectrum of the input signal and a specially designed ultra-compact structure for splitting the incident signal into those 32 filters with low power imbalance. Each SWF has a footprint less than 1 µm × 30,µm, while the 1 × 32 splitter and 32 filters in total occupy an area of about 35 µm × 260 µm, which to the best of our knowledge, is the smallest footprint spectrometer realized on silicon photonic platform. Experimental characteristics of the fabricated spectrometer demonstrate a broad operating bandwidth of 180 nm centered at 1550 nm and narrowband peaks with 0.45 nm Full-Width-Half-Maximum (FWHM) can be clearly resolved. This concept can also be implemented using other material platforms for operation in optical spectral bands of interest for various applications.

42 ENGINEERING↗

Collective optical Thomson scattering in pulsed-power driven high energy density physics experiments (invited)

Optical collective Thomson scattering is used to diagnose magnetized high energy density physics experiments at the Magpie pulsed-power generator at Imperial College London. The system uses an amplified pulse from the 2nd harmonic of a Nd:YAG laser (3 J, 8 ns, 532 nm) to probe a wide diversity of hightemperature plasma objects; with densities in the range of 10 17 -10 19 cm -3 and temperatures between 10 eV and a few keV. The scattered light is collected from 100 μm-scale volumes within the plasmas, which are imaged onto optical fiber arrays. Multiple collection systems observe these volumes from different directions, providing simultaneous probing with different scattering K-vectors (and different associated α-parameters, typically in the range 0.5 – 3) allowing independent measurements of separate velocity components of the bulk plasma flow. The fiber arrays are coupled to an imaging spectrometer with a gated ICCD. The spectrometer is configured to view the ion-acoustic waves (IAWs) of the collective Thomson scattered spectrum. Fits to the spectra with the theoretical spectral density function S(K,ω) yield measurements of the local plasma temperatures and velocities. Fitting is constrained by independent measurements of the electron density from laser interferometry, and the corresponding spectra for different scattering vectors. Furthermore, this TS diagnostic has been successfully implemented on a wide range of experiments, revealing temperature and flow velocity transitions across magnetized shocks, inside rotating plasma jets and imploding wire arrays, as well as providing direct measurements of drift velocities inside a magnetic reconnection current sheet.

47 OTHER INSTRUMENTATION↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

X-Ray Performance of Critical-angle Transmission Grating Prototypes for the Arcus Mission

Arcus is a proposed Explorer Class soft X-ray grating spectrometer. It aims to explore cosmic feedback by mapping hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes and to investigate the dynamics of protoplanetary disks and stellar accretion. Arcus features 12 m focal-length grazing-incidence silicon pore optics (SPO) developed for the Athena mission. Critical-angle transmission (CAT) gratings efficiently disperse high diffraction orders onto CCDs. We report new and improved X-ray performance results for Arcus-like CAT gratings, including a record resolving power for two coaligned CAT gratings. Multiple Arcus prototype grating facets were illuminated by an SPO at the PANTER facility. The facets consist of 32 × 32.5 mm 2 patterned silicon membranes, bonded to metal frames. The bonding angle is adjusted according to the measured average tilt angle of the grating bars in the membrane. Two simultaneously illuminated facets show a minor broadening of the Al-K α doublet in the 18th and 21st orders with the best-fit record effective resolving power of ${R}_{G}\approx {1.3}_{-0.5}^{+\infty }\times {10}^{4}$ (3σ), about three to four times the Arcus requirement. We measured the diffraction efficiency of quasi-fully illuminated gratings at O-K wavelengths in orders 4–7 in an Arcus-like configuration and compare results with synchrotron spot measurements. After corrections for geometrical effects and bremsstrahlung continuum, we find agreement between full and spot illumination at the two different facilities, as well as with the models used for Arcus effective area predictions. We find that these flight-like gratings meet the diffraction efficiency and greatly exceed the resolving power Arcus requires.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of Stark-split beam and carbon charge exchange emissions for simultaneous B-field and temperature/rotation analysis at DIII-D

A set of two newly designed, single-channel Czerny–Turner spectrometers has been deployed at the DIII-D tokamak for measurements of the motional Stark effect (MSE) split beam emission and the C6+ (CVI) carbon charge exchange recombination (CER) emission at high spectral (δλ = 0.13 nm) and temporal (1–5 kHz) resolution. High throughput optics (f/# = 2.8) allow for good signal-to-noise at high time resolution using fast EMCCD detectors. The MSE emission allows for spectral fitting of the magnitude and direction of the local B-field, while the carbon emission yields local ion temperature and toroidal rotation information. To reduce so-called Doppler broadening of the MSE emission, a new channel-specific variable lens-masking approach has been developed. Experimental data collected from the 2023 DIII-D experimental campaign demonstrate the signal quality and instrument fidelity for both diagnostic measurements. Moreover, initial CER data analysis shows a clear evolution of the toroidal rotation during edge localized modes. Initial progress on the advanced MSE model, including a new validated ray-trace model of the DIII-D collection optics, is shown via sensitivity analysis.

Instruments & Instrumentation↗

Fugitive methane detection using open-path stand-off chirped laser dispersion spectroscopy

We report an open-path chirped laser dispersion spectrometer capable of detecting the atmospheric methane concentration above the background using both specular and diffusive reflective surfaces via two distinct operation modes in a stand-off detection configuration. The system is integrated with simultaneous ranging functionality, which enables average concentration measurements for varying optical pathlengths. The system was first tested for accuracy and characterized to achieve sensitivity of 2.9 p p m - m / H z 1 / 2 and pathlength precision of 0.2 m / H z 1 / 2 with a controlled release of methane outside the laboratory. The instrument was subsequently field-deployed in the proximity of a natural gas compressor station for fugitive methane detection. The instrument successfully detected methane plumes and narrowed down the location of the plume through multi-path measurement. The field measurements were verified by a co-located reference mobile methane sensor.

Chen, Yifeng↗

Erosion resistance test of SiC mirror sample for ITER divertor VUV spectrometer

A series of tests have been performed to validate the resistance of the Silicon Carbide (SiC) mirror as the first mirror material of ITER VUV spectrometers to all ITER environmental conditions. Here we focused on the erosion (and deposition) of the SiC mirror sample caused by high-energy neutral particles. The flux of neutral particles reaching the first mirror was calculated using the ZEMAX software with a simplified entrance duct model. In the calculation, the particle flux reaching the first wall is necessary and the previously reported values derived from the SOLPS calculations were used. Based on this estimated particle flux, the erosion resistance tests were performed to check the erosion effect due to the high-energy neutral particles on the first mirror of ITER divertor VUV spectrometer. In the experiment, erosion was induced by exposing the SiC mirror sample to hydrogen and deuterium plasmas (and ions). The target fluence of incident ions in experiment is based on the estimation of the flux of neutral particles in ITER. The surface shape, composition, erosion depth, and surface roughness were measured to check the damage of the mirror surface after erosion test. Based on simulations and erosion resistance tests, it was concluded that the SiC mirror can be used as the first mirror of ITER divertor VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

Cold Gas and Star Formation in the Phoenix Cluster with JWST

We present integral field unit observations of the Phoenix Cluster with the JWST Mid-infrared Instrument’s Medium Resolution Spectrometer. We focus this study on the molecular gas, dust, and star formation in the brightest cluster galaxy (BCG). We use precise spectral modeling to produce maps of the silicate dust, molecular gas, and polycyclic aromatic hydrocarbons (PAHs) in the inner ∼50 kpc of the cluster. We measure the optical depth from silicates by comparing the observed H 2 line ratios to those predicted by excitation models. We provide updated measurements of the total molecular gas mass of $1.9^{+0.5}_{-0.04}$ x 10 10 M ⊙ , which agrees with CO-based estimates, providing an estimate of the CO-to-H 2 conversion factor of α CO = 0.8 ± 0.2 M ⊙ pc -2 (K km s -1 ) -1 ; an updated stellar mass of M * = 2.6 ± 0.5 × 10 10 M ⊙ ; and star formation rates (SFRs) averaged over 10 and 100 Myr of $\langle$SFR$\rangle$ 10 = 1340 ± 100 M ⊙ yr −1 and $\langle$SFR$\rangle$ 100 = 740 ± 80 M ⊙ yr −1 , respectively. The H 2 emission seems to be powered predominantly by shocks and star formation within the central ∼20 kpc, induced by stellar feedback and radio jets from the active galactic nucleus. Additionally, we find nearly an order-of-magnitude drop in the SFRs estimated by PAH fluxes in cool core BCGs compared to field galaxies, suggesting that hot particles from the intracluster medium are destroying PAH grains even in the central-most tens of kiloparsecs.

Active galaxies↗