Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen partial pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Mechanisms of oxidation in the Co-Cr system.

Oxidation has been studied both as a function of temperature in the range from 900 to 1300 C and of the partial pressure of oxygen in the range from 0.05 to 760 torr. In addition, microstructures of oxide scales have been studied and characterized in more detail utilizing metallographic and X-ray techniques combined with electron microprobe analysis. The parabolic rate constants in 1100 C and at 100 and 10 torr oxygen are presented in a graph as a function of chromium content. Three main different mechanisms of oxidation in the Co-Cr system have been identified. In two of these, the rate determining process controlling the oxidation is the solid state diffusion of cobalt through the oxide CoO. The rate controlling process governing the oxidation for the third mechanism is chromium diffusion in dichromium trioxide.

Kofstad, P. K.↗

A monkey metabolism pod for space-flight weightlessness studies.

The system described will permit quantitative physiological studies in adult monkeys, weighing from 8 to 14 kg, during future space flights. The system comprises a fiberglass pod containing a comfortable restraint couch for the animal. The pod is divided into upper and lower halves. When the monkey occupies the couch, a rubber belly-band forms a gas seal between the upper and lower portions of the animal. The upper-pod ventilating air stream is monitored for the partial pressures of oxygen, carbon dioxide, nitrogen, and water to permit continuous metabolic gas-exchange measurements for computation of metabolic energy expediture. The lower pod is lined with ashless filter paper for excreta collection.

Pace, N.↗

To the problem about the origin of lunar maria and continents (Moessbauer investigations)

A comparative study of Mossbauer spectra of regolith returned by the Luna 16 and Luna 20 spacecraft is presented. The Mossbauer spectra of the mare regolith differs significantly for all fractions from the spectra for the same fractions of continental regolith. The total quantity of iron is 1.85 times greater in the mare regolith. There is 2.4 times less olivine in the mare region than in the continental region. The pyroxene component of the mare regolith is less homogeneous in composition (contains more augite and glass) and is present in larger quantities. Ilmenite was found only in the mare regolith. In the continental region, the predominant titanium-containing phase is ulvospinel. The mare regolith contains more metallic iron, which is more finely dispersed and contains less nickel. Troilite is found in the maria region. Based on these differences, it is concluded that the formation of continental rocks occurred at an earlier stage of crystallization from the melt and at higher temperatures and higher partial pressures of oxygen. The mare basalts crystallized from a more reduced magma, apparently in a later process.

Malysheva, T. V.↗

Atmosphere

The physiological basis of the limits established for atmospheric pressure as well as the partial pressures of oxygen, carbon dioxide, water vapor, and diluent gas are reviewed.

Horrigan, D. J.↗

A new technique for measuring gas conversion factors for hydrocarbon mass flowmeters

A technique for measuring calibration conversion factors for hydrocarbon mass flowmeters was developed. It was applied to a widely used type of commercial thermal mass flowmeter for hydrocarbon gases. The values of conversion factors for two common hydrocarbons measured using this technique are in good agreement with the empirical values cited by the manufacturer. Similar agreements can be expected for all other hydrocarbons. The technique is based on Nernst theorem for matching the partial pressure of oxygen in the combustion product gases with that in normal air. It is simple, quick and relatively safe--particularly for toxic/poisonous hydrocarbons.

Singh, J. J.↗

Effects of solution mass transport on the ECC ozonesonde background current

A technique is developed to measure the effective mass transport parameter for the electrochemical concentration cell (ECC) ozonesonde in order to determine the mass transport rate constant for the ECC as a function of pressure. It is shown that a pressure dependent factor in the background current originates in a convective mass transport parameter. It is determined that for atmospheric pressures greater than 100 mb the mass transport parameter is a constant, while at pressures less than 100 mb it decreases logarithmically with pressure. It is suggested that the background current correction is directly correlated to the mass transport parameter pressure dependence. The presently used background current correction, which is based on the partial pressure of oxygen, is found to lead to an overestimation of the integrated ozone value in the troposphere for the ECC ozonesonde data.

Thornton, D. C.↗

A flow-system comparison of the reactivities of calcium superoxide and potassium superoxide with carbon dioxide and water vapor

A single pass flow system was used to test the reactivity of calcium superoxide with respiratory gases and the performance was compared to that of potassium superoxide. The KO2 system is used by coal miners as a self-contained unit in rescue operations. Particular attention was given to the reactivity with carbon dioxide and water vapor at different temperatures and partial pressures of oxygen, carbon dioxide, and water vapor. The calcium superoxide beds were found to absorb CO2 and H2O vapor, releasing O2. The KO2 bed, however, released O2 at twice the rate of CO2 absorption at 37 C. It is concluded that the calcium superoxide material is not a suitable replacement for the KO2 bed, although Ca(O2)2 may be added to the KO2 bed to enhance the CO2 absorption.

Wood, P. C.↗

New technique for calibrating hydrocarbon gas flowmeters

A technique for measuring calibration correction factors for hydrocarbon mass flowmeters is described. It is based on the Nernst theorem for matching the partial pressure of oxygen in the combustion products of the test hydrocarbon, burned in oxygen-enriched air, with that in normal air. It is applied to a widely used type of commercial thermal mass flowmeter for a number of hydrocarbons. The calibration correction factors measured using this technique are in good agreement with the values obtained by other independent procedures. The technique is successfully applied to the measurement of differences as low as one percent of the effective hydrocarbon content of the natural gas test samples.

Singh, J. J.↗

Technique for Measuring Gas Conversion Factors

Technique for measuring calibration conversion factors for hydrocarbon mass flowmeters applied to widely used type of commercial thermal mass flowmeter for hydrocarbon gases. Values of conversion factors for two common hydrocarbons measured using this technique in good agreement with empirical values cited by manufacturer. Similar agreement expected for all other hydrocarbons. Technique based on Nernst theorem for matching partial pressure of oxygen in combustion product gases with that in normal air. Simple, quick, and relatively safe, particularly for toxic/poisonous hydrocarbons.

Singh, J. J.↗

Challenges in the development of the orbiter atmosphere revitalization subsystem

The space shuttle orbiter atmospheric revitalization subsystem provides thermal and contaminant control as well as total- and oxygen partial-pressure control of the environment within the orbiter crew cabin. Challenges that occurred during the development of this subsystem for the space shuttle orbiter are described. The design of the rotating hardware elements of the system (pumps, fans, etc.) required significant development to meet the requirements of long service life, maintainability, and high cycle-fatigue life. As a result, a stringent development program, particularly in the areas of bearing life and heat dissipation, was required. Another area requiring significant development was cabin humidity control and condensate collection.

Prince, R. N.↗

Biological modulation of planetary atmospheres: The early Earth scenario

The establishment and subsequent evolution of life on Earth had a profound impact on the chemical regime at the planet's surface and its atmosphere. A thermodynamic gradient was imposed on near-surface environments that served as the driving force for a number on important geochemical transformations. An example is the redox imbalance between the modern atmosphere and the material of the Earth's crust. Current photochemical models predict extremely low partial pressures of oxygen in the Earth's prebiological atmosphere. There is widespread consensus that any large-scale oxygenation of the primitive atmosphere was contingent on the advent of biological (autotrophic) carbon fixation. It is suggested that photoautotrophy existed both as a biochemical process and as a geochemical agent since at least 3.8 Ga ago. Combining the stoichiometry of the photosynthesis reaction with a carbon isotope mass balance and current concepts for the evolution of the stationary sedimentary mass as a funion of time, it is possible to quantify, the accumulation of oxygen and its photosynthetic oxidation equivalents through Earth history.

Schidlowski, M.↗

An overview of Japanese CELSS research activities

Development of Controlled Ecological Life Support System (CELSS) technology is inevitable for future long duration stays of human beings in space, for lunar base construction and for manned Mars flight programs. CELSS functions can be divided into 2 categories, Environmental Control and Material Recycling. Temperature, humidity, total atmospheric pressure and partial pressure of oxygen and carbon dioxide, necessary for all living things, are to be controlled by the environment control function. This function can be performed by technologies already developed and used as the Environment Control Life Support System (ECLSS) of Space Shuttle and Space Station. As for material recycling, matured technologies have not yet been established for fully satisfying the specific metabolic requirements of each living thing including human beings. Therefore, research activities for establishing CELSS technology should be focused on material recycling technologies using biological systems such as plants and animals and physico-chemical systems, for example, a gas recycling system, a water purifying and recycling system and a waste management system. Japanese research activities were conducted and will be continued accordingly.

Nitta, Keiji↗

Active-to-passive transition in the oxidation of silicon carbide and silicon nitride in air

The active-to-passive transition in the oxidation of SiC and Si3N4 was determined in a flowing air environment as a function of temperature and total pressure. The experimentally observed transition temperatures ranged from a low of 1347 C to a high of 1543 C for partial pressures of oxygen of 2.5 and 123.2 Pa, respectively. The SiC and Si3N4 samples had approximately the same transition point for a given pressure. In general, the higher the flow rate, the higher the transition temperature for a given pressure. The transitions for SiC measured in this study agree with previous data for the transition of SiC measured in pure oxygen at reduced pressures and in oxygen inert gas mixtures.

Vaughn, Wallace L.↗

Automation of closed environments in space for human comfort and safety

The Environmental Control and Life Support System (ECLSS) for the Space Station Freedom and future colonization of the Moon and Mars presents new challenges for present technologies. Current plans call for a crew of 8 to live in a safe, shirt-sleeve environment for 90 days without ground support. Because of these requirements, all life support systems must be self-sufficient and reliable. The ECLSS is composed of six subsystems. The temperature and humidity control (THC) subsystem maintains the cabin temperature and humidity at a comfortable level. The atmosphere control and supply (ACS) subsystem insures proper cabin pressure and partial pressures of oxygen and nitrogen. To protect the space station from fire damage, the fire detection and suppression (FDS) subsystem provides fire sensing alarms and extinguishers. The waste management (WM) subsystem compacts solid wastes for return to Earth, and collects urine for water recovery. Because it is impractical, if not impossible, to supply the station with enough fresh air and water for the duration of the space station's extended mission, these elements are recycled. The atmosphere revitalization (AR) subsystem removes CO2 and other dangerous contaminants from the air. The water recovery and management (WRM) subsystem collects and filters condensate from the cabin to replenish potable water supplies, and processes urine and other waste waters to replenish hygiene water supplies. These subsystems are not fully automated at this time. Furthermore, the control of these subsystems is not presently integrated; they are largely independent of one another. A fully integrated and automated ECLSS would increase astronauts' productivity and contribute to their safety and comfort. The Kansas State University Advanced Design Team is in the process of researching and designing controls for the automation of the ECLSS for Space Station Freedom and beyond. The approach chosen to solve this problem is to divide the design into three phases. The first phase is to research the ECLSS as a whole system and then concentrate efforts on the automation of a single subsystem. The AR subsystem was chosen for our focus. During the second phase, the system control process will then be applied to the AR subsystem.

Source record↗

Automation of closed environments in space for human comfort and safety

The development of Environmental Control and Life Support Systems (ECLSS) for Space Station Freedom, future colonization of the Moon, and Mars missions presents new challenges for present technologies. ECLSS that operate during long-duration missions must be semi-autonomous to allow crew members environmental control without constant supervision. A control system for the ECLSS must address these issues as well as being reliable. The Kansas State University Advanced Design Team is in the process of researching and designing controls for the automation of the ECLSS for Space Station Freedom and beyond. The ECLSS for Freedom is composed of six subsystems. The temperature and humidity control (THC) subsystem maintains the cabin temperature and humidity at a comfortable level. The atmosphere control and supply (ACS) subsystem insures proper cabin pressure and partial pressures of oxygen and nitrogen. To protect the space station from fire damage, the fire detection and suppression (FDS) subsystem provides fire-sensing alarms and extinguishers. The waste management (WM) subsystem compacts solid wastes for return to Earth, and collects urine for water recovery. The atmosphere revitalization (AR) subsystem removes CO2 and other dangerous contaminants from the air. The water recovery and management (WRM) subsystem collects and filters condensate from the cabin to replenish potable water supplies, and processes urine and other waste waters to replenish hygiene water supplies. These subsystems are not fully automated at this time. Furthermore, the control of these subsystems is not presently integrated; they are largely independent of one another. A fully integrated and automated ECLSS would increase astronauts' productivity and contribute to their safety and comfort.

Source record↗

Airline Chair-rest Deconditioning: Induction of Immobilization Thromboemboli?

Air passenger miles will likely double by year 2020. The altered and restrictive environment in an airliner cabin can influence hematological homeostasis in passengers and crew. Flight-related deep various thromboemboli (DVT) have been associated with at least 577 deaths on 42 of 120 airlines from 1977 to 1984 (25 deaths/million departures), whereas many such cases go unreported. However, there are four major factors that could influence formation of possible flight-induced DVT: sleeping accomodations (via sitting immobilization), travelers' medical history (via tissue injury), cabin environmental factors (via lower partial pressure of oxygen and lower relative humidity), and the more encompassing chair-rest deconditioning (C-RD) syndrome. There is ample evidence that recent injury and surgery (especially in deconditioned hospitalized patients) facilitate thrombophlebitis and formation of DVT that may be exacerbated by the immobilization of prolonged air travel. In the healthy flying population immobilization factors associated with prolonged (> 5 hr) C-RID such as total body dehydration, hypovolemia and increased blood viscosity, and reduced various blood flow (pooling) in the legs may facilitate formation of DVT. However, data from at least four case-controlled epidemiological studies did not confirm a direct causative relationship between air travel and DART, but factors such as history of vascular thromboemboli, various insufficiency, chronic heart failure, obesity, immobile standing position, more than 3 pregnancies, infectious disease, long-distance travel, muscular trauma and violent physical effort were significantly more frequent in DVT patients than in controls. Thus, there is no clear, direct evidence yet that prolonged sitting in airliner seats, or prolonged experimental chair-rest- or bed- rest-deconditioning treatments cause deep various thromboemboli in healthy people.

Greenleaf, J. E.↗

Electron Field Emission Properties of Textured Platinum Surfaces

During ground tests of electric microthrusters and space tests of electrodynamic tethers the electron emitters must successfully operate at environmental pressures possibly as high as 1x10(exp -4) Pa. High partial pressures of oxygen, nitrogen, and water vapor are expected in such environments. A textured platinum surface was used in this work for field emission cathode assessments because platinum does not form oxide films at low temperatures. Although a reproducible cathode conditioning process did not evolve from this work, some short term tests for periods of 1 to 4 hours showed no degradation of emission current at an electric field of 8 V/mm and background pressures of about 1x10(exp -6) Pa. Increases of background pressure by air flow to about 3x10(exp -4) Pa yield a hostile environment for the textured platinum field emission cathode.

Sovey, James S.↗

Airline chair-rest deconditioning: induction of immobilisation thromboemboli?

Air passenger miles will likely double by year 2020. The altered and restrictive environment in an airliner cabin can influence haematological homeostasis in passengers and crew. Flight-related deep venous thromboemboli (DVT) have been associated with at least 577 deaths on 42 of 120 airlines from 1977 to 1984 (25 deaths/million departures), whereas many such cases go unreported. However, there are four major factors that could influence formation of possible flight-induced DVT: sleeping accommodations (via sitting immobilisation); travellers' medical history (via tissue injury); cabin environmental factors (via lower partial pressure of oxygen and lower relative humidity); and the more encompassing chair-rest deconditioning (C-RD) syndrome. There is ample evidence that recent injury and surgery (especially in deconditioned hospitalised patients) facilitate thrombophlebitis and formation of DVT that may be exacerbated by the immobilisation of prolonged air travel.In the healthy flying population, immobilisation factors associated with prolonged (>5 hours) C-RD such as total body dehydration, hypovolaemia and increased blood viscosity, and reduced venous blood flow (pooling) in the legs may facilitate formation of DVT. However, data from at least four case-controlled epidemiological studies did not confirm a direct causative relationship between air travel and DVT, but factors such as a history of vascular thromboemboli, venous insufficiency, chronic heart failure, obesity, immobile standing position, more than three pregnancies, infectious disease, long-distance travel, muscular trauma and violent physical effort were significantly more frequent in DVT patients than in controls. Thus, there is no clear, direct evidence yet that prolonged sitting in airliner seats, or prolonged experimental chair-rest or bed-rest deconditioning treatments cause DVT in healthy people.

Review, Tutorial↗