Search NASA⌕ Search

SEARCH · Search NASA

Results for “particle identification methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Dalitz Plot Analysis of B{sup -{yields}}D{sup +{pi}-{pi}-}

We present a Dalitz plot analysis of B{sup -{yields}}D{sup +{pi}-{pi}-} decays, based on a sample of about 383 million {Upsilon}(4S){yields}BB-bar decays collected by the BABAR detector at the PEP-II asymmetric-energy B Factory at SLAC. The analysis has been published previously in [1]. We measure the inclusive branching fraction of the three-body decay to be B(B{sup -{yields}}D{sup +{pi}+{pi}-}) = (1.08{+-}0.03(stat){+-}0.05(syst))x10{sup -3}. We observe the established D{sub 2}*{sup 0} and confirm the existence of D{sub 0}*{sup 0} in their decays to D{sup +{pi}-}, where the D{sub 2}*{sup 0} and D{sub 0}*{sup 0} are the 2{sup +} and 0{sup +} cu-bar P-wave states, respectively. We measure the masses and widths of D{sub 2}*{sup 0} and {Gamma}D{sub 0}*{sup 0} to be: mD{sub 2}* = (2460.4{+-}1.2{+-}1.2{+-}1.9) MeV/c{sup 2}, {Gamma}D{sub 2}* = (41.8{+-}2.5{+-}2.1{+-}2.0) MeV, mD{sub 0}* = (2297{+-}8{+-}5{+-}19) MeV/c{sup 2}, {Gamma}D{sub 0}* = (273{+-}12{+-}17{+-}45) MeV. The stated errors reflect the statistical and systematic uncertainties, and the uncertainty related to the assumed composition of signal events and the theoretical model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phosphorus doping of Si nanocrystals embedded in silicon oxynitride determined by atom probe tomography

Silicon nanocrystals (SiNCs) embedded in a silicon oxide matrix were studied by 3D atom probe tomography (APT). The distribution of the SiNC diameter was found to have a mean value of 3.7 ± 0.8 nm. The elemental composition of these particles was determined by employing two different approaches: (i) The proximity histogram method and (ii) a cluster identification algorithm based on maximum-atom separations. Both approaches give very similar values in terms of the amount of P, O, and Si within the SiNCs: the mean atomic concentrations are c{sub P} = 0.77% ± 0.4%, c{sub O} = 12.3% ± 2.1%, and c{sub Si} = 85.3% ± 2.1%. A detailed cluster analysis implies that, on average, a 4.5-nm SiNC would contain around 30 P atoms, whereas a 2.0-nm SiNC would contain only around 3 P atoms. Radial concentration profiles obtained for these SiNCs indicate that the P content is inhomogeneous and possibly enhanced at the boundary as compared to the interior of the NCs. About 20% of the P atoms are found to be incorporated into the SiNCs, whereas roughly 30% are trapped within the interfacial layer (with a thickness of ∼ 0.8 nm); the remainder resides in the surrounding matrix. Cluster-size dependent P concentrations support the view of self-purification in the Si nanostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Searching for the critical point of QCD: Theoretical benchmark calculations

We present a comprehensive study of event-by-event multiplicity fluctuations in nucleon-nucleon and nucleus-nucleus interactions from the BNL Alternating Gradient Synchrotron/GSI Facility for Antiproton and Ion Research to BNL Relativistic Heavy Ion Collider energies within the ultrarelativistic quantum molecular dynamics transport approach. The scaled variances of negative, positive, and all charged hadrons are analyzed. The scaled variance in central Pb+Pb collisions increases with energy and behaves similar to inelastic p+p interactions. We find a nontrivial dependence of multiplicity fluctuations on the rapidity and transverse-momentum interval used for the analysis and on the centrality selection procedure. Quantitative predictions for the NA49 experiment are given, taking into account the acceptance of the detector and the selection procedure of central events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exotic Meson Photoproduction at GlueX – Search for the hybrid candidate Y

Understanding the hadron spectrum is one of the primary goals of non-perturbative QCD. Many predictions have experimentally been confirmed, others still remain under experimental investigation. Of particular interest is how gluonic excitations give rise to states with constituent glue. One class of such states are hybrid mesons that are predicted by theoretical models and Lattice QCD calculations. Searching for and understanding the nature of these states is a primary physics goal of the GlueX experiment at the CEBAF accelerator at Jefferson Lab. A search for a JPC = 1-- hybrid meson candidate, the Y (2175), in phi(1020)pi+pi+ and phi(1020)f0(980) channels in photoproduction on a proton target has been conducted. A first measurement of non-resonant phi(1020)pi+pi+ and phi(1020)f0(980) total cross sections in photoproduction has been performed. An upper limit on the resonance production cross section for the Y (2175) -> phi(1020)pi+pi+ and Y (2175) -> phi(1020)f0(980) channels are estimated. Since the analysis essentially depends on the quality of the charged kaon identification, also an optimization of particle identification through an improvement of the energy loss estimation in the CDC by a truncated mean method has been investigated.

Hamdi, Abdennacer↗

Mixed Material Scintillator Systems for Neutron Detection

Scintillators are a fundamental technology that enables radiation detection. Their use has historically enabled the detection of incoming gamma radiation, with recent advances in plastic scintillator development enabling detection and discrimination of neutron and gamma radiation through pulse shape discrimination. However, scintillators have so far consisted of a single material, typically one primary dye and one secondary dye embedded in a plastic matrix. Based on the simulation studies described previously, mixed material scintillator systems with multiple secondary dyes arranged in alternating, periodic micro-sized regions opens the door for scintillators with a wide variety of different capability, such as directional sensing, positional reconstruction, particle identification, and pulse shape discrimination. However, fabrication of a mixed material scintillator system by conventional manufacturing methods is difficult to manufacture and scale, creating a barrier to their wide spread implementation. On the other hand, additive manufacturing additive manufacturing presents itself as the optimal method for fabricating mixed material scintillator systems based on its flexibility, ability to fabricate fine features, and potential for multimaterial fabrication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Measurement of the Neutron Magnetic Form Factor via the Ratio Method at Jefferson Lab Hall A

Protons and neutrons, collectively known as nucleons, are composed of quarks and gluons. The Sachs electromagnetic form factors encode information about the spatial distributions of charge and magnetization in the nucleon, particularly at low momentum transfer. In particular, the neutron magnetic form factor (GMn) provides crucial information about the distribution of magnetization inside the neutron and helps constrain theoretical models of nucleon structure. Quasi-elastic electron scattering from deuterium was measured up to Q^2=13.5 GeV^2 using the Super BigBite Spectrometer in Hall A at Jefferson Lab. In this work, the neutron magnetic form factor GMn was extracted at Q^2 = 3.0 GeV^2 and Q^2=4.5 GeV^2 using the Ratio Method. These results represent a subset of the full dataset collected in this experiment, which extended to significantly higher Q^2. The extracted GMn values agree with the existing global fit within approximately two standard deviations at Q^2=3.0 and show excellent agreement at Q^2=4.5. The measurements achieved systematic uncertainties of about 2% and statistical uncertainties below 0.5%, among the most precise determinations of GMn at these kinematics. These results demonstrate the robustness of the experimental technique and provide an important validation point for future extractions at higher Q^2, where data remain scarce. In addition, the GRINCH heavy gas Cherenkov detector—a key component of the experimental apparatus—was commissioned and achieved an electron detection efficiency of approximately 97%, supporting reliable particle identification. Together, the analysis presented here advances both our understanding of nucleon structure and the validation of the experimental methods and instrumentation used to access it.

Satnik, Maria [College of William and Mary, Willia↗

CC{pi}{sup 0} Event Reconstruction at MiniBooNE

We describe the development of a fitter to reconstruct v{sub {mu}} induced Charged-Current single {pi}{sup 0} (CC{pi}{sup 0}) events in an oil Cerenkov detector (CH{sub 2}). These events are fit using a generic muon and two photon extended track hypothesis from a common event vertex. The development of ring finding and particle identification are described. Comparisons between data and Monte Carlo are presented for a few kinematic distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Relative abundances of sub-iron to iron nuclei in low energy (50-250 MeV/N) cosmic rays as observed in the Skylab experiment

A Lexan polycarbonate detector exposed on the exterior of Skylab-3 for 73 days during a solar quiet period was used to study the relative abundances of calcium to nickel ions in low energy cosmic rays of 50 to 250 MeV/N. The method of charge identification is based on the measurement of conelength (L) and residual range (R) of these particles in various Lexan sheets. Since more than one cone (sometimes as many as five) is observed and is measured, the charge accuracy becomes precise and accurate. The ratio of (calcium to manganese) to (iron and cobalt) obtained at three energy intervals of 50 to 80, 80 to 150, 150 to 250 and 50 to 250 MeV/N are 7.6 plus or minus 3.8, 2.7 plus or minus 0.8, 1.4 plus or minus 0.6 and 3.3 plus or minus 0.7 respectively. These data thus indicate a large increase of this ratio with decreasing energy. The origin of this strong energy dependence is not understood at present.

Durgaprasad, N.↗

A survey of implicit particle filters for data assimilation [Implicit particle filters for data assimilation]

Implicit particle filters for data assimilation update the particles by first choosing probabilities and then looking for particle locations that assume them, guiding the particles one by one to the high probability domain. We provide a detailed description of these filters, with illustrative examples, together with new, more general, methods for solving the algebraic equations and with a new algorithm for parameter identification.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A method to investigate relativistic heavy ion collision

Parton energy loss in heavy ion collisions has been dealt in many different ways. At low collision energies, the high multiplicity and low energy partons are close in momentum space, difficulting the identification of a jet. We propose a method which could be complementary to the dihadron correlation analysis. The method selects events where there is at least one particle with certain minimum transverse momentum, then the momentum spectra for all particles belonging to such event is drawn. From those events it is possible to extract information of the collision. We discuss the applicability of the method in parton energy loss and other observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiological Source Term Estimation and Isotopic Identification with Parallel Log Domain Particle Filters

This paper presents a parallel log-domain particle filtering algorithm combined with gamma spectrum unfolding to perform localization, identification, and evaluation of multiple point sources of various isotopes in an environment with attenuating obstacles. The method uses sets of precomputed attenuation kernels that map the attenuation characteristics of the environment. These kernels are specific to the energy level of a photopeak of interest. The spectral measurements are deconvolved into count measurements of each photopeak. These count measurements are fed into a set of parallel particle filters using attenuation kernels computed for that photopeak’s energy level. The individual regularized particle filters perform all likelihood calculations in the logarithmic domain to mitigate the effects of particle degeneracy. The output of each particle filter is combined to estimate which isotopes are present as well as their positions and strengths. The performance of the algorithm is characterized in a lab-scale environment using a mobile robot equipped with a gamma ray spectrometer in the presence of up to three different radioactive isotopes simultaneously. The sources were localized to within 10 cm, and their strengths were estimated within 10% of their true values. Furthermore, the isotopes were all correctly identified, and no spurious sources were reported.

42 ENGINEERING↗

Particle tracing in the magnetosphere - New algorithms and results

A fast and efficient method is employed to trace charged particles through realistic magnetospheric electric and magnetic fields, greatly reducing computer simulation times. The method is applicable for particles having arbitrary charge, energy, or pitch angle but which conserve the first two adiabatic invariants. An efficient method is used to classify drift orbits, which greatly facilitates identification of the last closed drift path or other drift boundaries. The time-independent evolution of the bounce-averaged phase space density along convective drift orbits is calculated. These three tools can be used to quantitatively describe convective evolution of the particle distribution from the tail, an essential step in understanding the production of unstable distributions in the magnetosphere.

Sheldon, R. B.↗

Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15μm has been achieved, which is equivalent to a UCN energy resolution below 2 pico-electron-volts through the relation δE=m 0 gδx. Here, the symbols δE, δx, m 0 and g are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. As a result, this method allows different types of UCN spectroscopy and other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new detector array for diffractive physics in ALICE at the LHC

We discuss some aspects of a new sub-detector for the ALICE experiment at the LHC. This detector would enhance the capabilities of ALICE to study several topics of diffractive as well as of photon induced physics. It consists of four stations of scintillator pads that would tag the diffractive gap more efficiently.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of GeV Neutrino Events in LENA

LENA (Low Energy Neutrino Astronomy) is a proposed next generation liquid-scintillator detector with about 50 kt target mass. Besides the detection of solar neutrinos, geoneutrinos, supernova neutrinos and the search for the proton decay, LENA could also be used as the far detector of a next generation neutrino beam. The present contribution outlines the status of the Monte Carlo studies towards the reconstruction of GeV neutrinos in LENA. Both the tracking capabilities at a few hundred MeV, most interesting for a beta beam, and above 1 GeV for a superbeam experiment are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

(Multi-)strange hadron and light (anti-)nuclei production with ALICE at the LHC

Thanks to its excellent tracking performance and particle identification capabilities, the ALICE detector allows for the identification of light (anti-)(hyper)nuclei and for the measurement of (multi-)strange particles over a wide range of transverse momentum. Deuterons, {sup 3}He and {sup 4}He and their corresponding anti-nuclei are identified via their specific energy loss in the Time Projection Chamber and the velocity measurement provided by the Time-Of-Flight detector. Strange and multi-strange baryons and mesons as well as (anti-)hypertritons are reconstructed via their topological decays. Detailed measurements of (multi-)strange hadron production in pp, p–Pb and Pb–Pb collision and of light (anti-)nuclei and (anti-)hypertritons in Pb–Pb collisions with ALICE at the LHC are presented. The experimental results will be compared with the predictions of both statistical hadronization and coalescence models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector calibration using through going and stopping muons in the MicroBooNE LArTPC

The MicroBooNE experiment at Fermilab uses a liquid argon time projection chamber (LArTPC) in the Booster Neutrino Beam to search for anomalous production of electron-neutrino-like events and to study neutrino-argon cross sections in the 1 GeV neutrino energy regime. The detector operates at 0.273 kV/cm drift electric field and its TPC has an active mass of 85 tons of liquid argon. One of the main advantages of the LArTPC technology is its ability to reconstruct both particle track direction and energy with very high precision. Effects such as misconfigured or cross-connected TPC wires, space charge effects, electron attenuation, diffusion, and recombination can worsen the energy resolution of the detector. Therefore the detector calibration is of utmost importance to get the correct dE/dx (energy loss per unit track length) measurement. This is crucial for particle identification and in particular the separation of electrons and photons, essential for oscillation analyses. Here we describe a method developed for MicroBooNE to calibrate the detector by correcting for the above mentioned effects. In this analysis first we make the detector response uniform throughout the detector and time using through-going muons. Next stopping muons are used to determine the energy scale and convert dQ/dx to dE/dx.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency issues in Ce{sup 3+} doped YAG nanocrystals

Graphical abstract: The organic coating inevitably obtained from glycothermal syntheses of nano YAG:Ce in 1,4-butanediol proved to be beneficial and disadvantageous at the same time. The overall efficiency of the materials is further limited due to a strong decrease of the absorbtion. Highlights: {yields} Evaluation of hydrothermal nano-YAG:Ce synthesis. {yields} Determination of concentration and particle size dependence of optical properties. {yields} Analysis of surface species. {yields} Identification of efficiency limitations and bottlenecks. -- Abstract: Nanoparticles of Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+} (YAG:Ce{sup 3+}, 1%) were synthesized via the glycothermal method. The particle sizes were estimated by transmission electron microscopy, X-ray diffraction, surface area determination and by dynamic light scattering. We found primary particles of 10-14 nm in diameter, which form agglomerates of approximately 100 nm. For the 4f {yields} 5d transition of Ce{sup 3+} an internal quantum efficacy of up to 46% was measured. The particles consist of 6-10% of 1,4-butanediol attached on the surface, as determined by carbon content measurements in combination with IR and absorption spectroscopy. In particular, limiting drawbacks due to inevitable surface coatings for glycothermal syntheses and nanoscale associated scattering are elucidated.

36 MATERIALS SCIENCE↗