Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive interrogation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

178 records · Page 10

A Wireless Fluid-Level Measurement Technique

This paper presents the application of a recently developed wireless measurement acquisition system to fluid-level measurement. This type of fluid-level measurement system alleviates many shortcomings of fluid-level measurement methods currently being used, including limited applicability of any one fluid-level sensor design. Measurement acquisition shortcomings include the necessity for power to be supplied to each sensor and for the measurement to be extracted from each sensor via a physical connection to the sensor. Another shortcoming is existing measurement systems require that a data channel and signal conditioning electronics be dedicated to each sensor. Use of wires results in other shortcomings such as logistics needed to add or replace sensors, weight, potential for electrical arcing and wire degradations. The fluid level sensor design is a simple passive inductor-capacitor circuit that is not subject to mechanical failure that is possible when float and lever-arm systems are used. Methods are presented for using the sensor in caustic, acidic or cryogenic fluids. Oscillating magnetic fields are used to power the sensor. Once electrically excited, the sensor produces a magnetic field response. The response frequency corresponds to the amount to fluid within the capacitor s electric field. The sensor design can be modified for measuring the level of any fluid or fluent substance that can be stored in a non-conductive reservoir. The interrogation method for discerning changes in the sensor response frequency is also presented.

Woodard, Stanley E.↗

Survival Estimates for the Passage of Spring-Migrating Juvenile Salmonids through Snake and Columbia River Dams and Reservoirs, 2008.

In 2008, the National Marine Fisheries Service completed the sixteenth year of a study to estimate survival and travel time of juvenile salmonids Oncorhynchus spp. passing through dams and reservoirs on the Snake and Columbia Rivers. All estimates were derived from detections of fish tagged with passive integrated transponder (PIT) tags. We PIT tagged and released a total of 18,565 hatchery steelhead O. mykiss, 15,991 wild steelhead, and 9,714 wild yearling Chinook salmon O. tshawytscha at Lower Granite Dam in the Snake River. In addition, we utilized fish PIT tagged by other agencies at traps and hatcheries upstream from the hydropower system and at sites within the hydropower system in both the Snake and Columbia Rivers. These included 122,061 yearling Chinook salmon tagged at Lower Granite Dam for evaluation of latent mortality related to passage through Snake River dams. PIT-tagged smolts were detected at interrogation facilities at Lower Granite, Little Goose, Lower Monumental, Ice Harbor, McNary, John Day, and Bonneville Dams and in the PIT-tag detector trawl operated in the Columbia River estuary. Survival estimates were calculated using a statistical model for tag-recapture data from single release groups (the single-release model). Primary research objectives in 2008 were to: (1) estimate reach survival and travel time in the Snake and Columbia Rivers throughout the migration period of yearling Chinook salmon and steelhead, (2) evaluate relationships between survival estimates and migration conditions, and (3) evaluate the survival estimation models under prevailing conditions. This report provides reach survival and travel time estimates for 2008 for PIT-tagged yearling Chinook salmon (hatchery and wild), hatchery sockeye salmon O. nerka, hatchery coho salmon O. kisutch, and steelhead (hatchery and wild) in the Snake and Columbia Rivers. Additional details on the methodology and statistical models used are provided in previous reports cited here. Survival and detection probabilities were estimated precisely for most of the 2008 yearling Chinook salmon and steelhead migrations. Hatchery and wild fish were combined in some of the analyses. For yearling Chinook salmon, overall percentages for combined release groups used in survival analyses in the Snake River were 80% hatchery-reared and 20% wild. For steelhead, the overall percentages were 65% hatchery-reared and 35% wild. Estimated survival from the tailrace of Lower Granite Dam to the tailrace of Little Goose Dam averaged 0.939 for yearling Chinook salmon and 0.935 for steelhead.

13 HYDRO ENERGY↗

The Isothermal Oxidation of High-Purity Aluminum at High Temperature

The isothermal oxidation in air of high purity aluminum sheet was studied as a function of temperature using Thermogravimetric Analysis simultaneously with Differential Scanning Calorimetry (TGA/DSC). The rates and extents of oxidation were found to be non-linear functions of the temperature, in agreement with the literature. Between 650 °C and 750 °C very little oxidation took place; at 850 °C oxidation occurred after an induction period, while at 950 °C oxidation occurred without an induction period. At oxidation temperatures between 1050 °C and 1150 °C rapid passivation of the surface of the aluminum occurred, while at 1250 °C and above, an initial rapid mass increase was observed, followed by a more gradual increase in mass. The initial rapid increase in mass was accompanied by a significant exotherm, which was quantified by DSC. At temperatures of 1050 °C and above the specimen coalesced into a spheroidal particle, whereas at lower temperatures the original morphology was retained due to the cohesive strength of the native oxide layer. Cross-sections of oxidized specimens were characterized by scanning electron microscopy (SEM); the observed alumina skin thicknesses correlated qualitatively with the observed mass increases. Interrogation of the surface of an oxidized spheroidal particle by SEM showed a fractured alumina shell around a partially hollow core of aluminum which appeared to have grain boundaries.

36 MATERIALS SCIENCE↗

Passive Tomography for Spent Fuel Verification: Analysis Framework and Instrument Design Study

The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly is being assessed through a collaboration of Support Programs to the International Atomic Energy Agency (IAEA). In the first phase of this study, two safeguards verification objectives have been identified. The first is the independent determination of the number of active pins that are present in the assembly, in the absence of a priori information. The second objective is to provide quantitative measures of pin-by-pin properties, e.g. activity of key isotopes or pin attributes such as cooling time and relative burnup, for the detection of anomalies and/or verification of operator-declared data. The efficacy of GET to meet these two verification objectives will be evaluated across a range of fuel types, burnups, and cooling times, and with a target interrogation time of less than 60 minutes. The evaluation of GET viability for safeguards applications is founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types are used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. Instrument response data are processed by a variety of tomographic-reconstruction and image-processing methods, and scoring metrics specific to each of the verification objectives are defined and used to evaluate the performance of the methods. This paper will provide a description of the analysis framework and evaluation metrics, example performance-prediction results, and describe the design of a “universal” GET instrument intended to support the full range of verification scenarios envisioned by the IAEA.

spent nuclear fuel assemblies, partial defect veri↗

Active Neutron Interrogation of Non-Radiological Materials with the Nuclear Materials Identification System

The Nuclear Materials Identification System (NMIS) at Oak Ridge National Laboratory (ORNL), although primarily designed for analyzing special nuclear material, is capable of identifying nonradiological materials with a wide range of measurement techniques. This report demonstrates four different measurement methods, complementary to fast-neutron imaging, which can be used for material identification: DT transmission, DT scattering, californium transmission, and active time-tagged gamma spectroscopy. Each of the four techniques was used to evaluate how these methods can be used to identify four materials: aluminum, polyethylene, graphite, and G-10 epoxy. While such measurements have been performed individually in the past, in this project, all four measurements were performed on the same set of materials. The results of these measurements agree well with predicted results. In particular, the results of the active gamma spectroscopy measurements demonstrate the technique's applicability in a future version of NMIS which will incorporate passive and active gamma-ray spectroscopy. This system, designated as a fieldable NMIS (FNMIS), is under development by the US Department of Energy Office of Nuclear Verification.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Infrared surface phonon nanospectroscopy of an interacting dielectric-particle–dielectric-substrate dimer using fast electrons

Refinements in energy monochromation and aberration correction in state-of-the-art scanning transmission electron microscopes has opened access to the far infrared regime for spectroscopic characterization at the nanoscale. At these low energies, the dielectric environment, such as a dielectric slab adjacent to the target specimen, may no longer play a passive role in the spectrum. Instead, the environment may itself host resonances that mix with those of the target and complicate interpretation of its spectral responses. This article explores a theoretical description of the coupling between the collective vibrational surface modes of a dielectric particle and dielectric slab of varying thickness for the purpose of elucidating the interacting phononic excitations in dielectric materials typical of inelastic electron scattering measurements in the infrared. Dynamical coordinates and a governing Hamiltonian are rigorously defined in the quasistatic limit to account for phonon mode mixing and forcing by an aloof electron probe, which travels along a grazing trajectory, parallel to the dielectric slab. As the spectral window of interrogation by fast electron probes has been extended down to thermal energies with unprecedented meV energy resolution, theoretical models like that presented herein are crucial for accurate interpretation of experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiography of Dry Cask Storage for Used Nuclear Fuel

Since the U.S. currently only approves of storing used nuclear fuel in pools or dry casks, the demand for dry cask storage is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. With the rising demand comes additional pressure to ensure the integrity of dry cask systems. Visual inspection is costly and man-power intensive, so alternative nondestructive testing techniques are desired to insure the continued safe and effective storage of fuel. Several approaches being investigated by the University of Florida and the larger multi-university Department of Energy (DOE) Nuclear Energy University Program (NEUP) Integrated Research Project (IRP) are gamma or neutron radiography, both transmission based and interior source emission. Additionally muon radiography is discussed. This work leverages the well-established techniques in medical image reconstruction and applies them to a significantly larger scale with additional considerations due to the dense nuclear materials which serves as effective shields for radiation. Emission source radiography relies on the radiation that is emitted from the used fuel. The main advantage of this technique is the passive nature of the measurement. The fuel is already emitting radiation and only detectors are needed. Transmission radiography uses an external source of radiation to penetrate the side of the cask. Challenges include selecting the external source spectrum to avoid overlap with the spectrum emitted from the fuel, and ensuring the radiation dose limits do not exceed those mandated by the Nuclear Regulatory Commission (NRC). Benefits of this technique include better understanding of the source location allowing for clear image reconstruction, and isolation of the signal from surrounding radiation sources. Muon radiography takes advantage of the natural background flux coming from the interaction of the atmosphere with cosmic radiation. The technique is particularly effective at interrogating large dense objects as the highly energetic muons have smaller cross sections than most typical sources and energies used in nuclear engineering. The various techniques are discussed individually then the conclusion compares them. Finally, future work is identified.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance of 3 cm 3 ion trap vacuum package sealed for 10 years

Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10 -13 $τ$ -1/2 integrating down to 1×10 -14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.

74 ATOMIC AND MOLECULAR PHYSICS↗

Preparation for and Performance of a Pseudomonas aeruginosa Biofilm Experiment On Board the International Space Station

Biofilms are a problem on Earth given their ability to degrade the materials upon which they grow and due to their relevance to infections. Remarkably, 65% and 80% of infections and chronic diseases on Earth are associated with biofilms, respectively. In space, these problems' impact is higher because the crew's lives and mission success depend on nominal operation of mechanical systems. Furthermore, the isolated confined environment nature of spaceflight may increase the rates of disease transmission. In the case of the International Space Station (ISS), biofilms are an identified problem on the Environmental Control and Life Support System (ECLSS), namely on the water processor assembly (WPA). In late 2019, the Space Biofilms experiment launched towards ISS to (i) characterize the mass, thickness, morphology, and gene expression of biofilms formed in space with respect to matched Earth controls, (ii) interrogate the expression of antimicrobial resistance genes, and (iii) test novel materials as potential biofilm control strategies for future ECLSS components. For this, 288 bacterial samples were prepared prior to the launch of the Northrop Grumman CRS-12 mission from NASA's Wallops Flight Facility. The samples were integrated into the spaceflight hardware, BioServe's Fluid Processing Apparatus (FPA) packed in sets of eight in Group Activation Packs (GAP). Half of these samples were activated and terminated on orbit by NASA astronauts Jessica Meir and Christina Koch, while the remaining half were processed equivalently on Earth. The spaceflight bacterial samples of Space Biofilms returned on board SpaceX' CRS-19 Dragon spacecraft, in early 2020. We here describe the test campaign implemented to verify the experiment design and confirm it would enable us to achieve the project's scientific goals. This campaign ended with the Experiment Verification Test (EVT), from which we here present example morphology and transcriptomic results. We describe in detail the sample preparation prior to flight, including cleaning and sterilization of the coupons of six materials (SS316, passivated-SS316, lubricant impregnated surface, catheter-grade silicone with and without a nanotopography, and cellulose membrane), loading and integration of growth media, bacterial inoculum, fixative and preservative to enable experiment termination on orbit. Additionally, we describe the performance of the experiment on board the ISS, including crew activities, use of assets, temperature profile, and experiment timeline; all leading to a successful spaceflight experiment.

Pamela Flores↗

Multimodal Nondestructive Dry Cask Basket Structure and Spent Fuel Evaluation

This NEUP-IRP assembled a team from diverse institutions and a diverse set of expertise to examine the problem of assessing the structural health of dry nuclear fuel storage casks, specifically the TN-32 design. With no physical access designed into these storage casks and the high cost and risk associated with opening casks for direct inspection, the technical difficulty of structural assessment of the basket structure and fuel assemblies is high. In response to this challenge, this IRP brought together experts in both traditional and novel NDE methodologies: active acoustics (University of Mississippi), emissions tomography (University of Florida), muon tomography (Oregon State University), and passive-active ultrasonics (University of South Carolina). Further, our industry partners in the Electric Power Research Institute (EPRI) and AREVA provided invaluable insight into technical design details for the cask, practical knowledge of operating parameters at a storage facility, and key relationships that enabled activities unforeseen at the time of the proposed work but were critical in guiding the path of the research. The team decided early in the project that we had a collective goal of laying the technical ground work for practical solutions that could be implemented in the field with reasonable cost, time, and reliability. A fortunate opportunity arose early in this IRP project to obtain access to a new TN-32 cask at Columbiana High Tech. Both acoustics teams were given access for testing concepts in the first year of the project. This ended up providing critical guidance in the design of subsequent laboratory experiments. Specifically, it became clear that the only reliable acoustic pathways to the interior were through the trunnions, base plate, and top ring of the cask. Based on these field tests and discussions about what would be of practical interest, the team as a whole decided a realistic goal was to detect catastrophic failure of a single fuel assembly, or one that was missing. It is clear from this work that the active acoustics / resonance and muon tomography methodologies would be capable of detecting interior structural integrity problems at this level. The other two areas of investigation (emissions tomography and passive/active ultrasonics) would need more testing to determine a successful implementation, but each may also have other applications such as long term monitoring and monitoring during transportation. This IRP project resulted in technical advances with applications that extend beyond the problem at hand, supported the training of 10 graduate students + 1 post doc, 21 publications, and 13 conference presentations. The remainder of this summary highlights significant activities and achievements in each of the methodologies and a brief discussion on how they can be combined to leverage strengths. Active Acoustics The active acoustics team at UM used both linear and non-linear structural resonance methods to infer information about the internal structure of a cask. Significant activities were a set of four field test measurements on a full scale TN-32 cask at the Columbiana Hi Tech facility in Greensboro, NC and the design and fabrication of a 1/6th scale model TN-32 cask for laboratory measurements. A significant set of acoustic data has been acquired on both the full scale and laboratory scale casks. It was determined early in the project that mechanical resonance techniques were not going to be sensitive to small scale (centimeter) cracks and structural defects in the basket structure or fuel assemblies. We were able to ascertain that both the energy and complexity of the resonance spectra were sensitive to “bulk state” of the fuel assemblies – an intact assembly versus a severely degraded assembly. By developing a novel combination of metrics, we are able to measure a statistically significant shift due to one out of the 32 fuel assemblies being either missing or degraded to a point of complete loss of structural coherence (i.e. “rubble”). We believe this combination of resonance metrics is new to the field and will have applications beyond the fuel storage problem. Emissions Tomography The Emissions Tomography team at the University of Florida explored the concept of using scattering of radiation emissions from the stored fuel as method of evaluating the internal structural health of the cask. Due to the need for emissive fuel assemblies and the difficulties of gaining access to storage facilities, this team primarily relied on simulations to inform feasibility. A key question was the flux estimates of neutrons with a small enough number of scattering events to retain spatial information. Some key conclusions from the transmission component of this work are that the number of scattering events falls rapidly with energy – setting a 11MeV threshold, the average number of scattering events is 8∓4. Rough estimates of scanning times using an ideal detector array would be 1 week. The team also explored the case of significant structural failure resulting in a shift of the source material (fuel). The result is that a +/- 2% mass shift results in a detectable (5.13%) shift in the correlated 2 neutron emission counts and thus may be a candidate as an initial survey. Finally, simulations for predicting the azimuthal dependence of the flux based on specific loading patterns were conducted. Due to self-shielding effects of the assemblies, a periodic pattern results and could potentially be used to identify missing or severely degraded assemblies. This work forms a basis for proper detector placement with the goal of optimizing sensitivity. Muon Tomography Muon tomography (MT) is a relatively novel method of interrogating interior structure on a large scale. One of the advantages of this technique is that the exciting energy source (cosmic muons) is ubiquitous and relatively stable in time. Challenging aspects are relatively low flux rates and appropriate detector technologies. The efforts of the muon group at Oregon State University focused on two areas: (1) simulation of various combinations of muon scattering events and detection schemes to assess sensitivities and time scales for image construction and (2) building a prototype muon detection system applicable to the dry storage cask problem as well as many other similar systems. Significant accomplishments in this area are: (1) demonstration that MT is a viable method for detecting missing or severely degraded rod assemblies, (2) a scintillation based detector with 4 panels and 32 channels of position data each were constructed, tested, and calibrated. Testing of the panels using natural muon background and no scattering objects yielded largely expected results – a straight line path for the muon through the four panels. However some anomalies (paths deviating from a line) were also detected. A redesign of the board improved the signal which greatly improved the muon tracking through the panels. Testing with lead bricks as scattering bodies showed a reduction in the coincidence rate with increasing bricks indicating increased scattering events. A refinement of the scintillator detector design resulted in a spatial image resolution of around 2 cm based on lead brick spacing tests lasting 24 hours. Passive/Active Ultrasonics This team at the University of South Carolina investigated the feasibility of combining passive ultrasonics, in which an elastic pulse is generated by a degradation process (such as a crack extending), and active ultrasonics, in which a known excitation is introduced into the structure and detected by an array of transducers. Significant accomplishments in this area include the development of elastic wave propagation simulation in relevant materials, development of diagnostic algorithms, and laboratory testing and validation using laser doppler vibrometry. This group demonstrated the applicability of various non-contact vibration detection methodologies such as air-coupled ultrasonic transducers and scanning laser doppler vibrometry. While passive acoustic emissions monitoring will likely have a role during the transportation of a fuel storage cask, the level of detailed information about the defect generating the event which can be ascertained from the detections in a complex structure remains for future work. Thermography The EPRI team contributed early in the project a series of thermography measurements in which various levels of water pooled in a mock-up canister were analyzed using commercially available infrared imaging technologies. While large levels of water (100 L, ~10 cm deep) were observable in the thermograms, more realistic levels of pooled water (1 L) were not detectable whether localized or distributed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Analysis Technique for Active Neutron Multiplicity Measurements Based on First Principles

Passive neutron multiplicity counting is commonly used to quantify the total mass of plutonium in a sample, without prior knowledge of the sample geometry. However, passive neutron counting is less applicable to uranium measurements due to the low spontaneous fission rates of uranium. Active neutron multiplicity measurements are therefore used to determine the {sup 235}U mass in a sample. Unfortunately, there are still additional challenges to overcome for uranium measurements, such as the coupling of the active source and the uranium sample. Techniques, such as the coupling method, have been developed to help reduce the dependence of calibration curves for active measurements on uranium samples; although, they still require similar geometry known standards. An advanced active neutron multiplicity measurement method is being developed by Texas A&M University, in collaboration with Los Alamos National Laboratory (LANL) in an attempt to overcome the calibration curve requirements. This method can be used to quantify the {sup 235}U mass in a sample containing uranium without using calibration curves. Furthermore, this method is based on existing detectors and nondestructive assay (NDA) systems, such as the LANL Epithermal Neutron Multiplicity Counter (ENMC). This method uses an inexpensive boron carbide liner to shield the uranium sample from thermal and epithermal neutrons while allowing fast neutrons to reach the sample. Due to the relatively low and constant fission and absorption energy dependent cross-sections at high neutron energies for uranium isotopes, fast neutrons can penetrate the sample without significant attenuation. Fast neutron interrogation therefore creates a homogeneous fission rate in the sample, allowing for first principle methods to be used to determine the {sup 235}U mass in the sample. This paper discusses the measurement method concept and development, including measurements and simulations performed to date, as well as the potential limitations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Smolt Monitoring at the Head of Lower Granite Reservoir and Lower Granite Dam, 2005 Annual Report.

This project monitored the daily passage of Chinook salmon Oncorhynchus tshawytscha, steelhead trout O. mykiss, and sockeye salmon O. nerka smolts during the 2005 spring out-migration at migrant traps on the Snake River and Salmon River. In 2005 fish management agencies released significant numbers of hatchery Chinook salmon and steelhead trout above Lower Granite Dam that were not marked with a fin clip or coded-wire tag. Generally, the age-1 and older fish were distinguishable from wild fish by the occurrence of fin erosion. Age-0 Chinook salmon are more difficult to distinguish between wild and non-adclipped hatchery fish and therefore classified as unknown rearing. The total annual hatchery spring/summer Chinook salmon catch at the Snake River trap was 0.34 times greater in 2005 than in 2004. The wild spring/summer Chinook catch was 0.34 times less than the previous year. Hatchery steelhead trout catch was 0.67 times less than in 2004. Wild steelhead trout catch was 0.72 times less than the previous year. The Snake River trap collected 1,152 age-0 Chinook salmon of unknown rearing. During 2005, the Snake River trap captured 219 hatchery and 44 wild/natural sockeye salmon and 110 coho salmon O. kisutch of unknown rearing. Differences in trap catch between years are due to fluctuations not only in smolt production, but also differences in trap efficiency and duration of trap operation associated with flow. Trap operations began on March 6 and were terminated on June 3. The trap was out of operation for a total of one day due to heavy debris. FPC requested that the trap be restarted on June 15 through June 22 to collect and PIT tag age-0 Chinook salmon. Hatchery Chinook salmon catch at the Salmon River trap was 1.06 times greater and wild Chinook salmon catch was 1.26 times greater than in 2004. The hatchery steelhead trout collection in 2005 was 1.41 times greater and wild steelhead trout collection was 1.27 times greater than the previous year. Trap operations began on March 6 and were terminated on May 17 due to high flows. There were two days when the trap was taken out of service because of mechanical failure. Travel time (d) and migration rate (km/d) through Lower Granite Reservoir for passive integrated transponder (PIT) tagged Chinook salmon and steelhead trout marked at the Snake River trap were affected by discharge. Statistical analysis of 2005 data detected a relation between migration rate and discharge for hatchery Chinook but was unable to detect a relation for wild Chinook. The inability to detect a migration rate discharge relation for wild Chinook salmon was caused by a lack of data. For hatchery Chinook salmon there was a 1.8-fold increase in migration rate between 50 and 100 kcfs. For steelhead trout tagged at the Snake River trap, statistical analysis detected a significant relation between migration rate and lower Granite Reservoir inflow discharge. For hatchery and wild steelhead trout, there was a 2.2-fold and a 2.2-fold increase in migration rate, respectively, between 50 and 100 kcfs. Travel time and migration rate to Lower Granite Dam for fish marked at the Salmon River trap were calculated. Statistical analysis of the 2005 data detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge for hatchery Chinook salmon, wild Chinook salmon, hatchery steelhead trout, and wild steelhead trout. Migration rate increased 4.2-fold for hatchery Chinook salmon, 2.9-fold for wild Chinook salmon and 2.5-fold for hatchery steelhead, and 1.7-fold for wild steelhead as discharge increased between 50 kcfs and 100 kcfs. Fish tagged with PIT tags at the Snake River and Salmon River traps were interrogated at four dams with PIT tag detection systems (Lower Granite, Little Goose, Lower Monumental and McNary dams). Because of the addition of the fourth interrogation site (Lower Monumental) in 1993 and the installation of the Removable Spillway Weir at Lower Granite Dam in 2001, caution must be used in comparing cumulative interrogation data. Cumulative interrogations at the four dams for fish marked at the Snake River trap were 84% for hatchery Chinook, 89% for wild Chinook, 94% for hatchery steelhead, and 93% for wild steelhead. Cumulative interrogations at the four dams for fish marked at the Salmon River trap were 71% for hatchery Chinook, 78% for wild Chinook salmon, 80% for hatchery steelhead trout, and 81% for wild steelhead trout.

13 HYDRO ENERGY↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ice Cryo-Encapsulation Balloon (Project ICEBall) Field Campaign Report

The Ice Cryo-Encapsulation Balloon (ICEBall) field campaign was designed to sample the ice crystals that compose high-altitude cirrus with a passive device. The campaign made use of a new instrument, ICEBall, which is a balloon-borne ice crystal sampling system. The ice crystal sounding system is capable of measuring ice crystal concentration, temperature, atmospheric pressure, ice crystal habit, aerosol particle morphology, and residual composition. The 3-kg instrument is carried upwards at 5 m s-1 by a high-altitude balloon. The instrument can be cut down from the balloon at any altitude up to 20 km, and the apparatus returns to the surface by parachute. Basic measurements such as temperature and pressure are recorded onboard, and high-frequency Global Positioning System (GPS) records altitude and latitude/longitude. Ice crystal concentrations are measured through the use of a high-resolution video camera mounted on the device. Ice crystals are collected through an open aperture leading to insulated collection chambers cooled with dry ice. Upon exiting the top of the cloud system, the chamber aperture is closed, and the ~1 mm3 sample cell is magnetically sealed and isolated at -78 °C, ensuring that ice particles do not sublimate or grow after collection. Once the crystals are returned to the surface, they are double-sealed and immersed at liquid nitrogen temperature in “dry-cryo shippers” before being transported back to the laboratory. Dr. Magee’s laboratory at The College of New Jersey contains a cryo-stage scanning electron microscope (SEM), which was used to interrogate the crystals and aerosol particles. The main purpose of this pilot field campaign was to provide an unprecedented level of detail on the crystal habits and ice surface complexity in mid-latitude cirrus, which may help resolve issues associated with habit identification and classification in cirrus. The ICEBall campaign was originally scheduled to run from March 28 to April 18 of 2021 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains observatory. The COVID-19 pandemic intervened and caused us to shift the dates of the experiment to October 16-November 6 of 2021. This period is also climatologically favorable for cirrus. The approximately six-month gap between our original field campaign dates and the actual dates afforded us the opportunity to build two new ICEBall payload instruments. These instruments were tested during an August 2021 trip to The College of New Jersey. During this field testing phase, we decided to launch the ICEBall payload upstream from the ARM SGP site with the goal of landing in the vicinity of the site. Our goal was to sample the ice crystals before the cirrus were advected over the remote-sensing instruments at the SGP site. The team assembled for the field campaign consisted of the Principle Investigator (PI) and Co-Principle Investigator (Co-PI) (Drs. Harrington and Magee), The Pennsylvania State University research scientist Dr. Alfred Moyle, and two graduate students (Ms. Marley Majetic and Gwenore Pokrifka). The team operated out of a house rented in Enid, Oklahoma. We successfully sampled seven cirrus cloud systems during the three-week field campaign (October 21, 23-26, 31, and November 1). This was a much higher success rate than either of the PIs anticipated (our goal was closer to sampling three or four cases). The balloon was typically launched from oil pads or farm fields northwest of Enid and the payload was typically retrieved somewhat north of the SGP site. We never landed directly at the SGP site, and so did not need regular access to the SGP facilities. Our greatest concern going into the field campaign was the longer-term storage of crystals in the -196°C cryo dry-shipper dewars and the subsequent transport across the country. We had tested storage and transport prior to the field campaign, but we had never stored crystals for a few weeks nor had we transported the dewars over long distances. To our great relief, the storage and transport worked flawlessly and we were able to image a large number of crystals from six of the seven cases. Working with the staff at the ARM SGP office was excellent. They not only helped us find the sources we needed for helium, liquid nitrogen, and other materials, but also helped with contacts within the Federal Aviation Administration (FAA) and Vance Air Force Base. One goal of our field project was to tie the in situ measurements of ice crystal habits to the radar signatures derived from the Ka-band ARM Zenith-pointing Radar (KAZR). Unfortunately KAZR was down for the duration of our experiment. However, the Ka-band Scanning ARM Cloud Radar (KASACR) was put into vertically pointing mode during the ICEBall campaign and those data, along with Doppler lidar measurements, have proved very useful.

54 ENVIRONMENTAL SCIENCES↗

Static Strain Modelling, Calibration, and Measurements for High-Temperature Wireless SAW Resonator Operation

Static strain measurements are relevant for Integrated System Health Monitoring of civil structures, aircrafts, power plants and advanced manufacturing equipment, with implications for safety, process efficiency, and maintenance costs. Wireless strain sensing is highly desirable where the presence of wires poses significant safety concerns, increases maintenance, and thus overall costs, or where they are not feasible, such as in applications which contain moving parts. This paper presents wireless interrogation of surface acoustic wave resonators (SAWRs) fabricated on langasite (LGS) along Euler angles (0°, 138.5°, 32.9°) and aimed at the detection of static strain at hightemperature (HT, above 100°C). Both commercial HT strain gauges and finite element analysis (FEA Abaqus software) were used and compared for SAWR strain calibration from room temperature (RT) to HT. In addition, this work investigated a compromise between high temperature operation vs. sensitivity based on the thickness of ceramic adhesive used. For instance, a reduction in the adhesive thickness from about 150 μm to 135 μm, resulted in a 39% increase in sensitivity at RT. It was also observed that the sensitivity dropped up to 34% from RT to 200°C. Furthermore, wireless operation, calibration, and increase in sensitivity constitute important advances in the use of LGS SAW devices to monitor static stress in high-temperature harsh environments.

42 ENGINEERING↗

The Add-A-Source Matrix Calibration of a Large Neutron Box Counter

A general purpose passive neutron box counter has been designed, constructed and factory calibrated. The instrument is intended to sort and assay Transuranic Uranium (TRU) waste according to the Waste Isolation Pilot Plant (WIPP) criteria in containers ranging from drums to large boxes and crates. A multi-position Cf Add-A-Source (AAS) capability has been built into the system to determine gross matrix correction factors. The Cf source capsule runs in a U-shaped guide tube beneath the powered roller conveyor used to move the containers into the assay cavity from the loading station. The factory calibration involved measuring a wide range of matrix materials and densities in 208-liter (55 US-gal.) barrels, Standard Waste Box (SWB), Standard Large Box (SLB-2), and Ten Drum Overpack (TDOP) containers. For each container a Volume Weighted Average (VWA) rate and an AAS perturbation factor was determined and the relationship between them was established for the full range of conditions expected to be encountered operationally. In this paper we describe the calibration procedure which used Cf-252 as a surrogate for Pu-240 to map out the spatial responses for the various container-matrix combinations. A particular challenge was the scale of the measurement campaign which was directly related to the large volume of some of the containers. The reduction of the data was also challenging because for the larger items with high concentrations of hydrogen steep spatial gradients were observed in the response. For this reason simple volume-element averaging of the data to derive VWA quantities was inadequate and numerical-integration approaches of the 3-dimensional maps were explored. The response maps were also used to create point-source contributions to the Total Measurement Uncertainty (TMU), but this work is not the subject of this paper. The wide range in container size also required varying numbers of AAS interrogation position. For the drums a single AAS position was used while for the SWB and TDOP six positions were used to achieve better coverage of the cross-section. The SLB-2 has a larger cross section still and ten positions of the AAS were used for this container. The AAS calibration parameterizations for the various containers will be described along with the difficulties associated with a calibration of large containers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗