Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concentrating Rare Earth Elements in Coal mine drainage Using Coal Combustion Products through Abandoned Mine Land Reclamation

Rare earth elements (REEs) (including scandium, yttrium and a group of 15 lanthanides) are often considered to be critical components in the productions of renewable energy hardware, electric vehicles, health care and military equipment, and consumer electronic products. The demand of REEs has been projected to be growing at an annual rate of 5-9% in the next 25 years. In 2011, the global demand of total rare earth oxides (REOs) was estimated to be approximately 105,000 tons, which is expected to grow to 210,000 tons by 2025. China overwhelmingly dominates the current worldwide rare earth productions but has strategically restricted its exports, causing significant instability for the global market. In response to the increasing demand for REEs and the supply dominance of China, identifying alternative sources of REEs has become a critical issue for the United States and other countries. Coal, coal ash, and coal mine drainage (CMD) are considered to be the alternative sources of REEs. In the U.S., high REE concentrations have been reported to be closely associated with coal deposits, including the Appalachian Basins. When surface and/or groundwater come in contact with geologic strata containing sulfide minerals exposed by coal mining, the accelerated oxidation of sulfide minerals in the presence of ferric iron and/or oxygen can produce sulfuric acid. The process promotes the weathering of REE-bearing rocks and minerals in the host geologic strata. Compared to average river water and seawater, the concentrations of REEs can be orders of magnitude higher in CMD. In this study, we demonstrated a trap-extract-precipitate (TEP) process that can effectively recover REEs from CMD. The three-stage TEP process uses alkaline industrial by-products to capture REEs from CMD and then applies an extraction/precipitation procedure to produce a feedstock that can be economically processed to produce marketable rare earth oxides. The alkaline industrial by-products tested in this study include the residual from a water softening process (DRWP sludge) and two types of stabilized flue gas desulfurization materials (sFGDs). sFGD material is a mixture of lime (CaO) and two coal combustion by-products, calcium sulfite FGD by-product and fly ash. The objectives of this study are to (1) validate the effectiveness and feasibility; (2) determine mechanisms controlling the rare earth recovery, (3) quantify the associated economic and environmental benefits, and (4) evaluate the full-scale application. To achieve these objectives, tasks to be carried out in this proposed project are organized into three phases. In the first phase, the research team collaborated with Ohio Department of Natural Resources, American Electric Power, The Wilds (a nonprofit wildlife conservation organization), and a private landowner to carry out field investigations aimed to screen and evaluate the seasonal changes of rare earths in the CMD discharges that have high recovery potentials. Next, the recovery of REEs from CMD was tested using a series of lab-scale column and batch tests under, respectively, percolation and completely mixed conditions. Results obtained from these lab-scale studies show that all three tested solids are very effective in retaining REEs. Over 98% of the CMD REEs that contacted the solids were captured before the solids exhausted their neutralization capacities. We also determined an extraction process using a non-acid, organic ligand extraction solution that can effectively remobilize the retained REEs from the spent solids (over 90%). The REE concentrate (>7.5 wt. % of total REEs) is then formed in an aeration process. The TEP process uses environmentally benign industrial by-products and a naturally-occurring organic ligand to mitigate CMD and recover REEs. Techno-economic analysis (TEA) and life-cycle assessment (LCA) was carried out in the third phase. The engineering-economic costs and net energy, net CO2 emissions, and water and other requirements were investigated to understand the economic and environmental implications of this process. This work uses mass and energy balances from laboratory-scale experiments to estimate the economic costs and environmental impacts. The results suggest that passive treatment systems that use DRWP sludge are preferred over those that use sFGD material, because of lower economic costs ($89,300/yr with a unit cost of $86/gT-REE vs. $89,800/yr, or $278/gT-REE) and improved environmental performance across all indicators from two different impact assessment methods. These differences are largely attributable to the larger capacity of DRWP sludge in the passive treatment application. We envision this TEP process can be integrated with abandoned mine land (AML) reclamation to create an approach that can add economic incentives for AML reclamation, remediate CMD discharge, and eliminate public safety hazards and threats to local environment and ecological systems posed by AMLs. It can restore lands and communities that are adversely impacted by legacy mining.

01 COAL, LIGNITE, AND PEAT↗

Composite Solid Ion Conductor with Engineered Lithium Interface

Successful widespread commercialization of electric vehicles is contingent upon development of safe high energy density batteries capable of long cycle life. Lithium metal affords the highest theoretical capacity (3,860 mAh/g) and lowest electrochemical potential (-3.04V vs SHE), which offers the highest specific energy density of anode materials today. While Li-ion batteries are capable of delivering energy densities of 400-600 Wh/kg, the development of lithium metal batteries such as Li-S and Li-air may boost this number up to 650 and 950 Wh/kg, respectively. However, significant progress towards the passivation of lithium metal must occur before the energy density benefit can be realized. Issues with lithium dendrite formation, anode volume expansion, and continuous solid electrolyte interphase (SEI) build-up often result in significant safety concerns, high cell resistance, and poor cycle life. The intrinsic high reactivity between lithium metal with conventional lithium ion electrolytes (organic carbonate-based solvents) makes it extremely difficult to overcome these problems. In this project, Wildcat performed focused, fundamental research and development on composite polymer/ceramic electrolytes and protected lithium metal anodes to develop an all solid state lithium metal battery targeting the DOE requirements to enable commercialization. Wildcat successfully leveraged its high throughput battery platform and explored a broad composite electrolyte compositional space. Additionally, Wildcat screened large numbers of inorganic and organic coatings for lithium metal protection using in situ liquid methods and translated the best results to all solid cells. The proposed composite polymer/ceramic electrolyte and a protected lithium metal anode enabled a solid-state lithium metal battery. The ultimate targets from this effort will deliver a safe all solid-state lithium metal pouch cell with over 350 Wh/kg and over 1,000 cycles (C/3) with the cost estimate below $100/kWh. During the course of the project, we demonstrated stable cycling of 10’s of cycles with the composite SSE and our protected lithium. The work has continued after the conclusion of the DOE funding, demonstrating further improvements in catholyte composition and thinner composite solid electrolytes.

25 ENERGY STORAGE↗

Cable/Antenna Bounds Connecting Field Levels To Personnel Safety And Electronic Upset Thresholds

We use bounding models to estimate the power delivered to interior ordnance as well as the pin level voltages along a cable at interior electronic components. The procedures underlying these estimates are described in some detail. Conservation of steady-state power in a linear passive system underpins the power estimate, whereas, losses and quality factor limits underpin the limits on voltage transformations. The final levels are compared to no-fire threshold power and to minimum upset voltage levels in an example using a canonical slot aperture and cavity to estimate interior fields.

42 ENGINEERING↗

Preliminary Thermal-hydraulics and Selected Safety Analysis for Holos-Quad Reactor Design

This report presents thermal hydraulics and safety analyses of the 10 MWe Holos-Quad micro-reactor design developed by HolosGen LLC. These analyses were executed under steady-state and station black-out (SBO) transient conditions using the System Analysis Module (SAM), with a focus on ensuring peak fuel temperatures do not exceed the safety thresholds of 1,250°C for steady state normal operating conditions and 1,600°C for transient conditions. For steady-state temperature predictions, a coupled 1D fluid-to-3D solid heat conduction methodology was used. The steady-state simulations included a model of the central core region where power peaking occurs to predict the maximum steady-state fuel temperature, and a coarse-mesh full-core model to provide the initial condition for the consequent transient SBO decay heat removal simulation. The maximum fuel temperature predicted from the central core region simulations under the normal operating condition was 1,222°C, which is below the design limit 1,250°C. To simulate a SBO transient, a full core model was necessary because of the non-axial symmetric core design and heat loss from the outer core structures to the environment. To reduce the required computational costs, a novel scaled subassembly approach was used to model the full core domain. With the full core steady-state temperature distribution provided as the initial condition, the passive decay heat removal of the core was simulated with the scaled subassembly full core model under SBO transient conditions. This analysis showed that the peak fuel temperatures of the Holos-Quad core remained below their steady-state values during the transient, therefore much lower than the safety limit 1,600°C. This is mainly due to the large thermal inertia of the graphite matrix, relatively low power density, and the large surface-to-volume-ratio of the core. The preliminary analyses presented in this report confirm the inherent safety of the Holos-Quad micro-reactor thermal-hydraulics design, as the peak fuel temperatures under both normal and off-normal operational conditions remain within design and safety limits.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Bismuth and Platinum Bi-Metallic Nanoparticles to Enhance Melt Wire Temperature Resolution

Advanced manufacturing (AM) based on direct-write (DW) technologies has emerged as the predominant enabler for the fabrication of active and passive sensors to be deployed in harsh operating environments seen in a nuclear reactor. Recently, Idaho National Laboratory and Boise State University have recently established capabilities to incorporate advanced manufacturing (AM) methods to accelerate, modernize and enhance functionality of nuclear sensors and instrumentation to achieve the goal of enhancing the safety and efficiency of nuclear reactors. A significant thrust of this work includes the development of nuclear relevant feedstock materials compatible with a variety of direct-write processes for the development, fabrication and testing of AM sensors for peak temperature detection and neutron flux monitoring. For this report, bismuth and bismuth/platinum (BiPt) bi-metallic nanoparticles were synthesized using wet chemical approaches to develop bi-metallic feedstock materials to enhance the sensitivity of melt wires for peak temperature detection. Nanoparticle characterization was performed with Transmission Electron Microscopy (TEM) for nanoparticle composition and size, Transmission X-Ray Diffraction Fluorescence (TXRF) for nanoparticle composition, and Differential Scanning Calorimetry to elucidate the melting point of BiPt bi-metallic nanoparticles. Preliminary results indicate bi-metallic BiPt nanoparticles as a viable pathway for fabricating high resolution AM melt wires.

36 MATERIALS SCIENCE↗

Activation of lead coolant in Westinghouse lead fast reactor

The Westinghouse Lead-cooled Fast Reactor (LFR) is a medium-sized, passively safe, scalable reactor being developed by Westinghouse in collaboration with domestic and international organizations with the primary goals of reducing front-end capital cost and generating flexible and cost-competitive electricity while satisfying the highest standards in terms of safety and sustainability. An important aspect of new plant design is an assessment of activation level of its components so that an appropriate nuclear waste management plan can be established. As lead coolant is a distinguishing design feature of the LFR, its activation due to irradiation and the implications on establishing an appropriate waste disposal approach are important for engagement of project stakeholders, customers and nuclear safety regulators. This paper provides a brief description of the Westinghouse LFR design, a background on lead activation phenomenology, and then describes the methodology used for lead activation analysis performed with the computer code Serpent 2. It was determined that impurities naturally occurring in lead have the biggest contribution to lead activation. Corrosion and erosion products from the components immersed in lead can also be important contributors to lead activity and their impact can be limited by appropriate selection of materials and operating conditions. Polonium isotopes, resulting from bismuth generated from lead irradiation and its impurities, bring a notable contribution to the inhalation and ingestion doses during the plant operation and in the first years after the plant shutdown. However, it is not by far as important as for lead-bismuth coolant.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a FHR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform fluoride-salt-cooled high-temperature reactor (FHR) safety evaluations. The generic plant model is based on publicly-available FHR design information. For plant aspects (e.g., reactor building leak rate and details of the cover-gas system) that are not described in the FHR references, the analysts made assumptions needed to construct a MELCOR full-plant model. The FHR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to two coiled tube air heat ex changers. Three passive direct reactor auxiliary cooling systems provide heat removal to supplement or replace the emergency secondary system heat removal during accident conditions. Surrounding the reactor vessel is a low volume reactor cavity that insulates the reactor with fire bricks and thick concrete walls. A refractory reactor liner system provides water cooling to reduce the concrete wall temperatures. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, the primary system decay heat removal and also a piping leak of the line to the coolant drain tank.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Update on Cardinal: Toward Full Core Pebble Simulations

The new DOE-NE Center of Excellence for Thermal-fluids applications in Nuclear Energy inaugurated in April 2018 considers and researches novel new solution strategies for historically challenging flow issues that still plague the current fleet of deployed Light Water nuclear Reactors (LWRs) as well as predicting various fluid flow and fluid related issues with advanced reactor technologies. Our advanced thermal-fluids research and development approach synergistically combines three natural, though overlapping, length and time scales in a hierarchal multi-scale approach to avoid the temptation and pitfalls of attempting to develop a single solve-all algorithm for physical fluid flow problems that will span nine orders of magnitude in spatial and temporal scales. To demonstrate the multi-scale philosophy of the center we focus on Fluoride Cooled High Temperature Reactors (FHRs), and in particular on the Berkley’s PB-FHR Mark-I design. The Fluoride salt cooled High temperature Reactor (FHR) is a class of advanced nuclear reactors that combine the robust coated particle fuel form from high temperature gas cooled reactors, direct reactor auxiliary cooling system (DRACS) passive decay removal of liquid metal fast reactors, and the transparent, high volumetric heat capacitance liquid Fluoride salt working fluids - such as Flibe - from molten salt reactors. This combination of fuel and coolant enables FHRs to operate in a high-temperature low-pressure design space that has beneficial safety and economic implications. The PB-FHR reactor relies on a pebble bed approach and pebble bed reactors are in a sense the poster child for multi-scale analysis. The lower length-scale simulator for pebble reactor cores comprises three physics: neutronics (OpenMC), thermal-fluids (Nek5000/NekRS) and fuel performance (BISON). As part of Center of Excellence ongoing research efforts we have developed Cardinal, a new tool platform for lower length-scale simulation. Cardinal tightly couples all three physics and leverages advances in MOOSE such as the MultiApp system and the concept of MOOSE-wrapped Apps. The present report provides an update on the development of Cardinal with an extension of Cardinal to GPUs. We also perform a first-of-a-kind demonstration simulation on Summit representing a 10x capability increase in terms of pebble count for Cardinal.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cardinal: A Lower-Length-Scale Multiphysics Simulator for Pebble-Bed Reactors

This paper demonstrates a multiphysics solver for pebble-bed reactors, in particular, for Berkeley’s pebble-bed -fluoride-salt-cooled high-temperature reactor (PB-FHR) (Mark I design). The FHR is a class of advanced nuclear reactors that combines the robust coated particle fuel form from high-temperature gas-cooled reactors, the direct reactor auxiliary cooling system passive decay removal of liquid-metal fast reactors, and the transparent, high-volumetric heat capacitance liquid-fluoride salt working fluids (e.g., FLiBe) from molten salt reactors. This fuel and coolant combination enables FHRs to operate in a high-temperature, low-pressure design space that has beneficial safety and economic implications. The PB-FHR relies on a pebble-bed approach, and pebble-bed reactors are, in a sense, the poster child for multiscale analysis. Relying heavily on the MultiApp capability of the Multiphysics Object-Oriented Simulation Environment (MOOSE), we have developed Cardinal, a new platform for lower-length-scale simulation of pebble-bed cores. The lower-length-scale simulator comprises three physics: neutronics (OpenMC), thermal fluids (Nek5000/NekRS), and fuel performance (BISON). Cardinal tightly couples all three physics and leverages advances in MOOSE, such as the MultiApp system and the concept of MOOSE-wrapped applications. Moreover, Cardinal can utilize graphics processing units for accelerating solutions. In this paper, we discuss the development of Cardinal and the verification and validation and demonstration simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Review of heat transfer enhancement techniques for single phase flows

The thermal energy exchange between a flowing fluid and its confining channel is a ubiquitous process in modern society. To enhance the fluid-to-wall or wall-to-fluid heat transfer, several techniques have been developed to maximize the contact area between the fluid and the inner wall and/or disrupt the flow to enhance circulation or induce turbulence. Deployment of channels having features capable of enhancing heat transfer enables the reduction of heat exchanger size while maintaining performance. Reduction in equipment size is critical due to the ability to minimize the required volume of costly working fluids and to mitigate potential safety concerns associated with total system fluid volume. Here, a comprehensive review of single-phase heat transfer enhancement techniques is presented. The article provides a thorough comparison by analyzing the heat transfer rate, pressure drop, and other operational aspects. Single-phase heat transfer enhancement methods are divided into active and passive techniques. Active methods such as electrohydrodynamic (EHD), magnetohydrodynamics (MHD), or mechanical motion require external power to create enhancement. Passive methods such as dimples, fins, or tape inserts do not require external input and rely only on surface modification. Although active methods are more expensive and difficult to implement compared to passive techniques, it enables active control of heat transfer augmentation. Finally, this review develops and summarizes key learning data for design optimization enabled by additive manufacturing and machine learning algorithms, helping to inform these next-generation heat exchanger design methodologies for a plethora of modern applications such as electrification of vehicles, computing, and classical industries.

42 ENGINEERING↗

Spatiotemporal Adaptive Passive Direct Air Capture

Carbon Collect Inc., along with Arizona State University, the Electric Power Research Institute (EPRI), PM Group, and Trimeric Corporation, completed an initial design of a commercial-scale, passive direct air capture (DAC) system termed “carbon trees” that will capture, separate, and store at least 100,000 tonnes/year of carbon dioxide (CO2) from air (net basis). Passive DAC is unique among DAC technologies in that passive air delivery by wind avoids the energy penalty of forced convection. Carbon Collect Inc.’s sorbent-agnostic approach offers the flexibility to choose sorbents for a wide range of climates. A combination of steam, low-grade heat, and vacuum releases the CO2 from the sorbent, which is extracted from the chamber and purified and compressed for geological storage. A commercial carbon tree forest combines the output of several thousand trees for compression and purification with high heat and energy integration. The project team prepared an initial engineering design package for each of three geographically diverse host sites throughout the United States to better understand the effect of local/regional ambient conditions on DAC system performance and project costs. A techno-economic analysis, life cycle analysis, business case analysis, and an environmental, health, and safety risks assessment were also completed for each of the three geographically diverse host sites.

14 SOLAR ENERGY↗

Adhesion of impure ice on surfaces

The undesirable buildup of ice can compromise the operational safety of ships in the Arctic to high-flying airplanes, thereby having a detrimental impact on modern life in cold climates. The obstinately strong adhesion between ice and most functional surfaces makes ice removal an energetically expensive and dangerous affair. Hence, over the past few decades, substantial efforts have been directed toward the development of passive ice-shedding surfaces. Conventionally, such research on ice adhesion has almost always been based on ice solidified from pure water. However, in all practical situations, freezing water has dissolved contaminants; ice adhesion studies of which have remained elusive thus far. Here, in this work, we cast light on the fundamental role played by various impurities (salt, surfactant, and solvent) commonly found in natural water bodies on the adhesion of ice on common structural materials. We elucidate how varying freezing temperature & contaminant concentration can significantly alter the resultant ice adhesion strength making it either super-slippery or fiercely adherent. The entrapment of impurities in ice changes with the rate of freezing and ensuing adhesion strength increases as the cooling temperature decreases. We discuss the possible role played by the in situ generated solute enriched liquid layer and the nanometric water-like disordered ice layer sandwiched between ice and the substrate behind these observations. Our work provides useful insights into the elementary nature of impure water-to-ice transformation and contributes to the knowledge base of various natural phenomena and rational design of a broad spectrum of anti-icing technologies for transportation, infrastructure, and energy systems.

36 MATERIALS SCIENCE↗

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling↗