Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance advantaged”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Minimum energy, liquid hydrogen supersonic cruise vehicle study

The potential was examined of hydrogen-fueled supersonic vehicles designed for cruise at Mach 2.7 and at Mach 2.2. The aerodynamic, weight, and propulsion characteristics of a previously established design of a LH2 fueled, Mach 2.7 supersonic cruise vehicle (SCV) were critically reviewed and updated. The design of a Mach 2.2 SCV was established on a corresponding basis. These baseline designs were then studied to determine the potential of minimizing energy expenditure in performing their design mission, and to explore the effect of fuel price and noise restriction on their design and operating performance. The baseline designs of LH2 fueled aircraft were than compared with equivalent designs of jet A (conventional hydrocarbon) fueled SCV's. Use of liquid hydrogen for fuel for the subject aircraft provides significant advantages in performance, cost, noise, pollution, sonic boom, and energy utilization.

Brewer, G. D.↗

Skeletal muscle fiber type composition and performance during repeated bouts of maximal, concentric contractions

Force output and fatigue and recovery patterns were studied during intermittent short-term exercise. 27 men performed three bouts of 30 maximal unilateral knee extensions on 2 different occasions. Blood flow was maintained or occluded during recovery periods (60 s). Blood flow was restricted by inflating a pneumatic cuff placed around the proximal thigh. Muscle biopsies from vastus lateralis were analyzed for identification of fast twitch (FT) and slow twitch (ST) fibers and relative FT area. Peak torque decreased during each bout of exercise and more when blood flow was restricted during recovery. Initial peak torque (IPT) and average peak torque (APT) decreased over the three exercise bouts. This response was 3 fold greater without than with blood flow during recovery. IPT and APT decreased more in individuals with mainly FT fibers than in those with mainly ST fibers. It is suggested that performance during repeated bouts of maximal concentric contractions differs between individuals with different fiber type composition. Specifically, in high intensity, intermittent exercise with emphasis on anaerobic energy release a high FT composition may not necessarily be advantageous for performance.

Muscle Contraction↗

Integrated Pressure-Fed Liquid Oxygen / Methane Propulsion Systems - Morpheus Experience, MARE, and Future Applications

An integrated liquid oxygen (LOx) and methane propulsion system where common propellants are fed to the reaction control system and main engines offers advantages in performance, simplicity, reliability, and reusability. LOx/Methane provides new capabilities to use propellants that are manufactured on the Mars surface for ascent return and to integrate with power and life support systems. The clean burning, non-toxic, high vapor pressure propellants provide significant advantages for reliable ignition in a space vacuum, and for reliable safing or purging of a space-based vehicle. The NASA Advanced Exploration Systems (AES) Morpheus lander demonstrated many of these key attributes as it completed over 65 tests including 15 flights through 2014. Morpheus is a prototype of LOx/Methane propellant lander vehicle with a fully integrated propulsion system. The Morpheus lander flight demonstrations led to the proposal to use LOx/Methane for a Discovery class mission, named Moon Aging Regolith Experiment (MARE) to land an in-situ science payload for Southwest Research Institute on the Lunar surface. Lox/Methane is extensible to human spacecraft for many transportation elements of a Mars architecture. This paper discusses LOx/Methane propulsion systems in regards to trade studies, the Morpheus project experience, the MARE NAVIS (NASA Autonomous Vehicle for In-situ Science) lander, and future possible applications. The paper also discusses technology research and development needs for Lox/Methane propulsion systems.

Hurlbert, Eric↗

Laparoscopic surgery in weightlessness

BACKGROUND: Performing a surgical procedure in weightlessness has been shown not to be any more difficult than in a 1g environment if the requirements for the restraint of the patient, operator, and surgical hardware are observed. The feasibility of performing a laparoscopic surgical procedure in weightlessness, however, has been questionable. Concerns have included the impaired visualization from the lack of gravitational retraction of the bowel and from floating debris such as blood. METHODS: In this project, laparoscopic surgery was performed on a porcine animal model in the weightlessness of parabolic flight. RESULTS: Visualization was unaffected due to the tethering of the bowel by the elastic mesentery and the strong tendency for debris and blood to adhere to the abdominal wall due to surface tension forces. CONCLUSIONS: There are advantages to performing a laparoscopic instead of an open surgical procedure in a weightless environment. These will become important as the laparoscopic support hardware is miniaturized from its present form, as laparoscopic technology becomes more advanced, and as more surgically capable crew medical officers are present in future long-duration space-exploration missions.

manned↗

Fan Noise Control Using Herschel-quincke Resonators

The research effort proposed for this NASA NRA is mainly experimental. In addition, Virginia Tech is working in partnership with Goodrich Aerospace, Aerostructures Group for the analytical development needed to support the experimental endeavor, i.e. model development, design, and system studies. In this project, Herschel-Quincke (HQ)liner technology experiments will be performed at the NASA Glenn Active Noise Control Fan (ANCF) facility. A schematic of both inlet and aft HQ-liner systems installed in the ANCF rig as well as a picture of the Glenn facility is shown. The main goal is to simultaneously test in both the inlet and bypass duct sections. The by-pass duct will have HQ-systems in both the inner and outer duct walls. The main advantages of performing tests at the ANCF facility are that the effect of the inlet HQ-system on the by-pass HQ-system and vice versa, can be accurately determined from the in-duct modal data. Another significant advantage is that it offers the opportunity to assess (on a common basis) the proposed noise reduction concept on the ANCF rig which in the past has been used for assessing other active and passive noise reduction strategies.

Burdisso, Ricardo A.↗

Selection of Optical Glasses Using Buchdahl's Chromatic Coordinate

This investigation attempted to extend the method of reducing the size of glass catalogs to a global glass selection technique with the hope of guiding glass catalog offerings. Buchdahl's development of optical aberration coefficients included a transformation of the variable in the dispersion equation from wavelength to a chromatic coordinate omega defined as omega = (lambda - lambda(sub 0))/ 1 + 2.5(lambda - lambda(sub 0)) where lambda is the wavelength at which the wavelength is calculated and lambda(sub 0) is a base wavelength about which the expansion is performed. The advantage of this approach is that the dispersion equation may be written in terms of a simple power series and permits direct calculation of dispersion coefficients. While several promising examples were given, a systematic application of the technique to an entire glass catalog and analysis of the subsequent predictions was not performed. The goal of this work was to apply the technique in a systematic fashion to glasses in the Schoft catalog and assess the quality of the predictions.

Griffin, DeVon W.↗

Micromechanics-based Modeling of Laminated SiC/SiC Ceramic Matrix Composites

The behavior and response of ceramic matrix composites (CMCs), in particular silicon carbide fiber reinforced silicon carbide matrix (SiC/SiC), is affected by many factors such as variation of fiber volume fraction, residual stresses resulting from processing of the composites at high temperature, random microstructures, and the presence of matrix flaws (e.g., voids, pores, cracks etc.) as well as general material nonlinearity and heterogeneity that occurs randomly in a composite. Residual stresses arising from the phase change of constituents are evaluated in this paper and it is shown that they do influence composite strength and need to be properly accounted for. Additionally, the microstructures (location of fiber centers, coating thickness etc.) of advanced CMCs are usually disordered (or random) and fiber diameter and strength typically have a distribution. They rarely resemble the ordered fiber packing (square, rectangular, or hexagonal) that is generally assumed in micromechanics-based models with periodic boundary conditions for computational expediency. These issues raise the question of how should one model such systems effectively? Can an ordered hexagonal packed repeating unit cell (RUC) accurately represent the random microstructure behavior? How many fibers need to be included to enable accurate representation? Clearly, the number of fibers within an RUC must be limited to insure a balance between accuracy and efficiency. NASA’s in-house micromechanics-based code MAC/GMC provides a framework to analyze such RUCs for the overall composite behavior and the FEAMAC computer code provides linkage of MAC/GMC to the commercial FEA code, ABAQUS. The appropriate level of discretization of the RUC as well as the analysis method employed, i.e., Generalized Method of Cells (GMC) or High Fidelity Generalized Method of Cells (HFGMC), is investigated in this paper in the context of a unidirectional as well as a cross-ply laminated CMC. Results including effective composite properties, proportional limit stress (an important design parameter) and fatigue are shown utilizing both GMC as well as HFGMC. Finally, a few multiscale analyses are performed on smooth bar test coupons as well as test coupons with features such as open-hole and double notches using FEAMAC. Best practices and guidance are provided to take these phenomena into account and keep a proper balance between fidelity (accuracy) and efficiency. Following these guidelines can account for important physics of the problem and provide significant advantages when performing large multiscale composite structural analyses.

Ceramic Matrix Composites↗

Network issues for large mass storage requirements

File Servers and Supercomputing environments need high performance networks to balance the I/O requirements seen in today's demanding computing scenarios. UltraNet is one solution which permits both high aggregate transfer rates and high task-to-task transfer rates as demonstrated in actual tests. UltraNet provides this capability as both a Server-to-Server and Server-to-Client access network giving the supercomputing center the following advantages highest performance Transport Level connections (to 40 MBytes/sec effective rates); matches the throughput of the emerging high performance disk technologies, such as RAID, parallel head transfer devices and software striping; supports standard network and file system applications using SOCKET's based application program interface such as FTP, rcp, rdump, etc.; supports access to the Network File System (NFS) and LARGE aggregate bandwidth for large NFS usage; provides access to a distributed, hierarchical data server capability using DISCOS UniTree product; supports file server solutions available from multiple vendors, including Cray, Convex, Alliant, FPS, IBM, and others.

Perdue, James↗

Ultralight Weight Optical Systems Using Nano-Layered Synthesized Materials

Optical imaging is important for many NASA science missions. Even though complex optical systems have advanced, the optics, based on conventional glass and mirrors, require components that are thick, heavy and expensive. As the need for higher performance expands, glass and mirrors are fast approaching the point where they will be too large, heavy and costly for spacecraft, especially small satellite systems. NASA Langley Research Center is developing a wide range of novel nano-layered synthesized materials that enable the development and fabrication of ultralight weight optical device systems that enable many NASA missions to collect science data imagery using small satellites. In addition to significantly reducing weight, the nano-layered synthesized materials offer advantages in performance, size, and cost.

Clark, Natalie↗

Mars Rocket Propulsion System

A report discusses the methane and carbon monoxide/LOX (McLOx) rocket for ascent from Mars as well as other critical space propulsion tasks. The system offers a specific impulse over 370 s roughly 50 s higher than existing space-storable bio-propellants. Current Mars in-situ propellant production (ISPP) technologies produce impure methane and carbon monoxide in various combinations. While separation and purification of methane fuel is possible, it adds complexity to the propellant production process and discards an otherwise useful fuel product. The McLOx makes such complex and wasteful processes unnecessary by burning the methane/CO mixtures produced by the Mars ISPP systems without the need for further refinement. Despite the decrease in rocket-specific impulse caused by the CO admixture, the improvement offered by concomitant increased propellant density can provide a net improvement in stage performance. One advantage is the increase of the total amount of propellant produced, but with a decrease in mass and complexity of the required ISPP plant. Methane/CO fuel mixtures also may be produced by reprocessing the organic wastes of a Moon base or a space station, making McLOx engines key for a human Lunar initiative or the International Space Station (ISS) program. Because McLOx propellant components store at a common temperature, very lightweight and compact common bulkhead tanks can be employed, improving overall stage performance further.

Zubrin, Robert↗

Evaluation of Carbon Dioxide Sensors for the Constellation Space Suit Life Support System for Surface Exploration

This paper presents the findings of the trade study to evaluate carbon dioxide (CO2) sensing technologies for the Constellation (Cx) space suit life support system for surface exploration. The trade study found that nondispersive infrared absorption (NDIR) is the most appropriate high Technology Readiness Level (TRL) technology for the CO2 sensor for the Cx space suit. The maturity of the technology is high, as it is the basis for the CO2 sensor in the Extravehicular Mobility Unit (EMU). The study further determined that while there is a range of commercial sensors available, the Cx CO2 sensor should be a new design. Specifically, there are light sources (e.g., infrared light emitting diodes) and detectors (e.g., cooled detectors) that are not in typical commercial sensors due to cost. These advanced technology components offer significant advantages in performance (weight, volume, power, accuracy) to be implemented in the new sensor. The exact sensor design (light source, transmitting optics, path length, receiving optics and detector) will be specific for the Cx space suit and will be determined by the performance requirements of the Cx space suit. The paper further identifies specifications for some of the critical performance parameters as well as discussing the engineering aspects of implementing the sensor into the Portable Life Support System (PLSS). The paper then presents testing results from three CO2 sensors with respect to issues important to Extravehicular Activity (EVA) applications; stability, humidity dependence and low pressure compatibility. The three sensors include two NDIR sensors, one commercial and one custom-developed by NASA (for a different purpose), and one commercial electrochemical sensor. The results show that both NDIR sensors have excellent stability, no dependence on ambient humidity (when the ambient temperature is above the dew point) and operate in low pressure conditions and after being exposed to a full vacuum. The commercial electrochemical sensor was not suitable for the Cx space suit for surface exploration. Finally, the paper identifies a number of techniques currently under development that offer significant advantages for EVA applications. These include miniaturized, room temperature, solid electrolyte systems and advanced optical detectors.

Dietrich, Daniel L.↗

A GPS-Based Pitot-Static Calibration Method Using Global Output-Error Optimization

Pressure-based airspeed and altitude measurements for aircraft typically require calibration of the installed system to account for pressure sensing errors such as those due to local flow field effects. In some cases, calibration is used to meet requirements such as those specified in Federal Aviation Regulation Part 25. Several methods are used for in-flight pitot-static calibration including tower fly-by, pacer aircraft, and trailing cone methods. In the 1990 s, the introduction of satellite-based positioning systems to the civilian market enabled new inflight calibration methods based on accurate ground speed measurements provided by Global Positioning Systems (GPS). Use of GPS for airspeed calibration has many advantages such as accuracy, ease of portability (e.g. hand-held) and the flexibility of operating in airspace without the limitations of test range boundaries or ground telemetry support. The current research was motivated by the need for a rapid and statistically accurate method for in-flight calibration of pitot-static systems for remotely piloted, dynamically-scaled research aircraft. Current calibration methods were deemed not practical for this application because of confined test range size and limited flight time available for each sortie. A method was developed that uses high data rate measurements of static and total pressure, and GPSbased ground speed measurements to compute the pressure errors over a range of airspeed. The novel application of this approach is the use of system identification methods that rapidly compute optimal pressure error models with defined confidence intervals in nearreal time. This method has been demonstrated in flight tests and has shown 2- bounds of approximately 0.2 kts with an order of magnitude reduction in test time over other methods. As part of this experiment, a unique database of wind measurements was acquired concurrently with the flight experiments, for the purpose of experimental validation of the optimization method. This paper describes the GPS-based pitot-static calibration method developed for the AirSTAR research test-bed operated as part of the Integrated Resilient Aircraft Controls (IRAC) project in the NASA Aviation Safety Program (AvSP). A description of the method will be provided and results from recent flight tests will be shown to illustrate the performance and advantages of this approach. Discussion of maneuver requirements and data reduction will be included as well as potential applications.

Foster, John V.↗

Low-cost quasi-parabolic antenna

Antenna design employs flat petal-shaped aluminum sheets and novel rim configuration. New antenna is inexpensive and has only slightly degraded performance. Design advantages are low-cost tooling and fabrication, convenient size and shape for transport and assembly, and simple assembly procedure.

Taggart, R. B., Jr.↗

Simple gas chromatographic system for analysis of microbial respiratory gases

Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

Carle, G. C.↗

Candidate space processing techniques for biomaterials other than preparative electrophoresis

The advantages of performing the partition and countercurrent distribution (CCD) of cells in phase separated aqueous polymer systems under reduced gravity were assessed. Other possible applications considered for the space processing program include the freezing front separation of cells, adsorption of cells at the air-water interface, and the macrophage electrophoretic mobility test for cancer.

Brooks, D. E.↗

Feasibility analysis of gravitational experiments in space

Experiments on gravitation and general relativity suggested by different workers in the past ten or more years are reviewed, their feasibility examined, and the advantages of performing them in space were studied. The experiments include: (1) the gyro relativity experiment; (2) experiments to test the equivalence of gravitational and inertial mass; (3) an experiment to look for nongeodesic motion of spinning bodies in orbit around the earth; (4) experiments to look for changes of the gravitational constant G with time; (5) a variety of suggestions; laboratory tests of experimental gravity; and (6) gravitational wave experiments.

Everitt, C. W. F.↗

Differential capacitance sensor as position detector for a magnetic suspension densimeter

In the present work, which consists of adapting a magnetic suspension densimeter for use at pressures up to 350 bars, a differential capacitance sensor is developed for use in the servosystem of a magnetic suspension densimeter for detecting the position of a magnetic buoy. This type of sensor has not been used previously in magnetic suspension densimeters. Its design, performance, and advantages are outlined. A cutaway drawing and a schematic diagram of the capacitance sensor and magnetic buoy are presented and described. The concentric-disk design of the sensor capacitor plates and the high degree of symmetry which results from the printed circuit fabrication approach minimize the sensor sensitivity to lateral displacement of the buoy and to the dielectric constant of the surrounding medium. A high-power microscope is necessary to monitor the position of the buoy relative to the support coil.

Frederick, N. V.↗

Design and performance of compliant thrust bearing with spiral-groove membranes on resilient supports

Novel thrust bearings with spiral-groove flexible membranes mounted on resilient supports were designed and their performance demonstrated. Advantages of surface compliance were combined with the superior load-capacity of the spiral-groove geometry. Loads of 127-150N were supported on an area 42 sq cm, at speeds of 43,000-45,000 rpm and mean clearances of 15-20 microns. Support-worthiness was proved when tested in conjunction with foil journal-bearings and a 19N rotor, excited in a pitching mode by a total unbalance of 43 micron-N.

Licht, L.↗