Techniques and Applications of SAR interferometry for ERS-1: Topographic Mapping, Change Detection, and Slope Measurement

SAR (Synthetic Aperture Radar) interferometry allows the measurement of high resolution topography of terrain from repeat orbit SAR data sets obtained by the ERS-1 AMI (Active Microwave Instrument). The system parameters which affect the accuracy of the topographic maps are errors in determination of the interferometric baseline, non parallel orbit tracks, decorrelation caused by baseline length, thermal noise, and surface change. Surface change can be observed in the interferograms either through decorrelation of the interferometric phase, or coherent phase shifts caused by locally uniform surface displacements. Phase gradient maps can be derived directly from the complex interferograms and can be transformed into surface slopes mapped onto a geometrically corrected grid.

Charles L Werner↗

Optical diagnostics of solution crystal growth

Solution crystal growth monitoring of LAP/TGS crystals by various optical diagnostics systems, such as conventional and Mach-Zehnder (M-Z) interferometers, optical heterodyne technique, and ellipsometry, is under development. The study of the dynamics of the crystal growth process requires a detailed knowledge of crystal growth rate and the concentration gradient near growing crystals in aqueous solution. Crystal growth rate can be measured using conventional interferometry. Laser beam reflections from the crystal front as well as the back surface interfere with each other, and the fringe shift due to the growing crystal yields information about the growth rate. Our preliminary results indicate a growth rate of 6 A/sec for LAP crystals grown from solution. Single wavelength M-Z interferometry is in use to calculate the concentration gradient near the crystal. Preliminary investigation is in progress using an M-Z interferometer with 2 cm beam diameter to cover the front region of the growing crystal. In the optical heterodyne technique, phase difference between two rf signals (250 KHZ) is measured of which one is a reference signal, and the other growth signal, whose phase changes due to a change in path length as the material grows. From the phase difference the growth rate can also be calculated. Our preliminary results indicate a growth rate of 1.5 A/sec. the seed and solution temperatures were 26.46 C and 27.92 C respectively, and the solution was saturated at 29.0 C. an ellipsometer to measure the growth rate and interface layer is on order from JOBIN YVON, France. All these systems are arranged in such a manner that measurements can be made either sequentially or simultaneously. These techniques will be adapted for flight experiment.

Kim, Yongkee↗

Relative tracking of multiple spacecraft by interferometry

An analysis is conducted of earth-based radiometric tracking of one spacecraft relative to an angularly nearby second spacecraft. Two cases are studied: relative positioning between a lander and a rover on the surface of Mars and relative tracking between a Mars lander and a Mars orbiter. All spacecraft signals are simultaneously received in the same beamwidth of an earth tracking antenna. Differential interferometric measurement errors are predicted. Errors which scale with angular separation between sources and errors which scale with temporal separation between measurement epochs are reduced virtually to zero. System thermal noise and systematic phase shifts introduced by receiver electronics typically dominate the error budget. Solar plasma delays become dominant for signal paths which pass close to the sun. Precise line-of-sight range measurements, differenced between stations, are also considered. Meter-level accuracy is obtained for lander/rover relative position by combining interferometric and precise range measurements. Either data type alone, for geometries where earth is not near zero declination as seen from Mars and Mars is not near zero declination as seen from earth, can provide accuracy at the 10-100-m level.

Border, James S.↗

Data transmission by quantum matter wave modulation

Abstract Classical communication schemes exploiting wave modulation are the basis of our information era. Quantum information techniques with photons enable future secure data transfer in the dawn of decoding quantum computers. Here we demonstrate that also matter waves can be applied for secure data transfer. Our technique allows the transmission of a message by a quantum modulation of coherent electrons in a biprism interferometer. The data is encoded in the superposition state by a Wien filter introducing a longitudinal shift between separated matter wave packets. The transmission receiver is a delay line detector performing a dynamic contrast analysis of the fringe pattern. Our method relies on the Aharonov–Bohm effect but does not shift the phase. It is demonstrated that an eavesdropping attack will terminate the data transfer by disturbing the quantum state and introducing decoherence. Furthermore, we discuss the security limitations of the scheme due to the multi-particle aspect and propose the implementation of a key distribution protocol that can prevent active eavesdropping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two-stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Rydberg Excitation of Single Atoms for Applications in Quantum Information and Metrology

With the advent of laser cooling and trapping, neutral atoms have become a foundational source of accuracy for applications in metrology and are showing great potential for their use as qubits in quantum information. In metrology, neutral atoms provide the most accurate references for the measurement of time and acceleration. The unsurpassed stability provided by these systems make neutral atoms an attractive avenue to explore applications in quantum information and computing. However, to fully investigate the eld of quantum information, we require a method to generate entangling interactions between neutral-atom qubits. Recent progress in the use of highly-excited Rydberg states for strong dipolar interactions has shown great promise for controlled entanglement using the Rydberg blockade phenomenon. I report the use of singly-trapped 133 Cs atoms as qubits for applications in metrology and quantum information. Each atom provides a physical basis for a single qubit by encoding the required information into the ground-state hyper ne structure of 133 Cs. Through the manipulation of these qubits with microwave and optical frequency sources, we demonstrate the capacity for arbitrary single-qubit control by driving qubit rotations in three orthogonal directions on the Bloch sphere. With this control, we develop an atom interferometer that far surpasses the force sensitivity of other approaches by applying the well-established technique of lightpulsed atom-matterwave interferometry to single atoms. Following this, we focus on two-qubit interactions using highly-excited Rydberg states. Through the development of a unique single-photon approach to Rydberg excitation using an ultraviolet laser at 319 nm, we observe the Rydberg blockade interaction between atoms separated by 6.6(3) m. Motivated by the observation of Rydberg blockade, we study the application of Rydberg-dressed states for a quantum controlled-phase gate. Using a realistic simulation of the dressed-state dynamics, we calculate a controlled-phase gate delity of 94% that is primarily limited by Doppler frequency shifts. Finally, we employ our single-photon excitation laser to measure the Rydberg-dressed interaction, thus demonstrating the viability of this approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Holographic interferometric tomography for reconstructing flow fields

Holographic interferometric tomography is a technique for instantaneously capturing and quantitatively reconstructing three-dimensional flow fields. It has a very useful application potential for high-speed aerodynamics. However, three major challenging tasks need to be accomplished before its practical applications. First, fluid flows are mostly unsteady or at least non repeatable. Consequently, a means for Instantaneously recording three-dimensional flow fields, that is, a simple holographic technique for simultaneously recording multi-directional projections, needs to be developed. Second, while holographic interferometry provides enormous data storage capabilities, expeditious data extraction from complicated interferograms is very important for timely near real-time applications. Third, unlike medical applications, flow tomography does not provide complete data sets but instead involves ill-posed reconstruction problems of incomplete projection and limited angular scanning. During this summer research period, new experimental techniques and corresponding hardware were developed and tested to address the above mentioned tasks. The first task was achieved by diffuser illumination. This concept allows instantaneous capture of many projections with a conventional setup for single-projection recording. For the second task, a phase-shifting technique was incorporated. This technique allows one to acquire multiple phase-stepped interferograms for a single projection and thus to extract phase information from intensity data almost at real-time. For the third task, the research that has been extensively conducted previously was utilized. In this research period, a complete experimental setup that provides the above three major capabilities was designed, built, and tested by integrating all the techniques. A simple laboratory experiment for simulating wind-tunnel testing was then conducted. A test flow was produced by employing a relatively simple device that generated a gravity-driven flow. The flow was then experimentally investigated to check the viability of the holographic interferometric tomographic technique before wind-tunnel application.

Cha, Soyoung S.↗

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

High-resolution broadband spectroscopy using externally dispersed interferometry at the Hale telescope: Part 2, photon noise theory

High-resolution broadband spectroscopy at near-infrared (NIR) wavelengths (950 to 2450 nm) has been performed using externally dispersed interferometry (EDI) at the Hale telescope at Mt. Palomar, with the TEDI interferometer mounted within the central hole of the 200-in. primary mirror in series with the comounted TripleSpec NIR echelle spectrograph. These are the first multidelay EDI demonstrations on starlight. We demonstrated very high (10×) resolution boost and dramatic (20× or more) robustness to point spread function wavelength drifts in the native spectrograph. Data analysis, results, and instrument noise are described in a companion paper (part 1). This part 2 describes theoretical photon limited and readout noise limited behaviors, using simulated spectra and instrument model with noise added at the detector. We show that a single interferometer delay can be used to reduce the high frequency noise at the original resolution (1× boost case), and that except for delays much smaller than the native response peak half width, the fringing and nonfringing noises act uncorrelated and add in quadrature. This is due to the frequency shifting of the noise due to the heterodyning effect. We find a sum rule for the noise variance for multiple delays. The multiple delay EDI using a Gaussian distribution of exposure times has noise-to-signal ratio for photon-limited noise similar to a classical spectrograph with reduced slitwidth and reduced flux, proportional to the square root of resolution boost achieved, but without the focal spot limitation and pixel spacing Nyquist limitations. At low boost (~1×) EDI has ~1.4× smaller noise than conventional, and at >10× boost, EDI has ~1.4× larger noise than conventional. Readout noise is minimized by the use of three or four steps instead of 10 of TEDI. Net noise grows as step phases change from symmetrical arrangement with wavenumber across the band. As a result, for three (or four) steps, we calculate a multiplicative bandwidth of 1.8:1 (2.3:1), sufficient to handle the visible band (400 to 700 nm, 1.8:1) and most of TripleSpec (2.6:1).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel femtosecond-gated, high-resolution, frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experiments

Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiers synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Doppler vibrometer employing active frequency feedback

We present a heterodyne Michelson interferometer for vibration measurement in which feedback is used to obviate the need to unwrap phase data. The Doppler shift of a vibrating target mirror is sensed interferometrically and compensated by means of a voltage-controlled oscillator driving an acousto-optic modulator. For frequencies within the servo bandwidth, the oscillator control voltage provides a direct measurement of the target velocity. Outside the servo bandwidth, phase-sensitive detection is used to evaluate high-frequency displacements. This approach is of great interest for the frequently-occurring situation where vibration amplitudes at low frequency exceed an optical wavelength, but knowledge of the vibration spectrum at high frequency is important as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Zero-added-loss entanglement multiplexing using time-bin spectral shearing

High-quality quantum communications that enable important capabilities, such as distributed quantum computing and sensing, will require quantum repeaters for providing high-quality entanglement. To realize high-rate heralded entanglement for quantum repeaters, Chen et al . [Phys. Rev. Appl. 19 , 054029 (2023)] proposed a scheme for heralded-multiplexed generation of quasideterministic entangled photon pairs, called zero-added-loss multiplexing (ZALM). Here, we propose a design of the ZALM source using time-bin entanglement and spectral shearing. Additionally, we provide an analysis of experimentally relevant spectral-shearing parameters to optimize the spectral multiplexing. Moreover, we experimentally verify the compatibility of time-bin pulses and spectral shearing, as supported by observation of no appreciable phase shift when the same shearing is applied to both time bins. These results expand the benefits of applying a ZALM source to time-bin entanglement use cases. Moreover, more fully demonstrating time-bin and spectral shearing compatibility clears a path toward a broader use of spectral shearing that provides a deterministic frequency shift of high utility.

entanglement production↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electro-optic modulation of a laser at microwave frequencies for interferometric purposes

A multi-point microwave interferometer (MPMI) concept was previously proposed by the authors for spatially-resolved, non-invasive tracking of a shock, reaction, or detonation front in energetic media [P. Specht et al., AIP Conf. Proc. 1793, 160010 (2017).]. The advantage of the MPMI concept over current microwave interferometry techniques is its detection of Doppler shifted microwave signals through electro-optic (EO) modulation of a laser. Since EO modulation preserves spatial variations in the Doppler shift, collecting the EO modulated laser light into a fiber array for recording with an optical heterodyne interferometer yields spatially-resolved velocity information. This work demonstrates the underlying physical principle of the MPMI diagnostic: the monitoring of a microwave signal with nanosecond temporal resolution using an optical heterodyne interferometer. For this purpose, the MPMI concept was simplified to a single-point construction using two tunable 1550 nm lasers and a 35.2 GHz microwave source. A (110) ZnTe crystal imparted the microwave frequency onto a laser, which was combined with a reference laser for determination of the microwave frequency in an optical heterodyne interferometer. A single, characteristic frequency associated with the microwave source was identified in all experiments, providing a means to monitor a microwave signal on nanosecond time scales. Lastly, areas for improving the frequency resolution of this technique are discussed, focusing on increasing the phase-modulated signal strength.

Specht, Paul E. (ORCID:000000027007000X)↗

Dual-wavelength low-coherence instantaneous phase-shifting interferometer to measure the shape of a segmented mirror with subnanometer precision

We present a noncontact optical metrology measuring the pistons and tip/tilt angles of the 61 hexagonal segments of a compact-sized segmented mirror. The instrument has been developed within the scope of a design study for the European Extremely Large Telescope (E-ELT). It is used as reference sensor for cophasing of the mirror segments in closed-loop control. The mirror shape is also measured by different types of stellar light-based phasing cameras whose performances will be evaluated with regard to a future E-ELT. Following a description of the system architecture, the second part of the paper presents experimental results demonstrating the achieved precision: 0.48 nm rms in piston and 74 nrad rms in tip/tilt.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE PHASES DIFFERENTIAL ASTROMETRY DATA ARCHIVE. IV. THE TRIPLE STAR SYSTEMS 63 Gem A AND HR 2896

Differential astrometry measurements from the Palomar High-precision Astrometric Search for Exoplanet Systems (PHASES) are used to constrain the astrometric orbit of the previously known {approx}<2 day subsystem in the triple system 63 Gem A and have detected a previously unknown two-year Keplerian wobble superimposed on the visual orbit of the much longer period (213 years) binary system HR 2896. 63 Gem A was already known to be triple from spectroscopic work, and absorption lines from all three stars can be identified and their individual Doppler shifts measured; new velocities for all three components are presented to aid in constraining the orbit and measuring the stellar masses. In fact, 63 Gem itself is a sextuple system: the hierarchical triple (Aa1-Aa2)-Ab (in which Aa1 and Aa2 orbit each other with a rapid period just under 2 days, and Ab orbits these every two years), plus three distant common proper motion companions. The very small astrometric perturbation caused by the inner pair in 63 Gem A stretches the limits of current astrometric capabilities, but PHASES observations are able to constrain the orientation of the orbit. The two bright stars comprising the HR 2896 long-period (213 year) system have a combined spectral type of K0III and the newly detected object's mass estimate places it in the regime of being an M dwarf. The motion of the stars are slow enough that their spectral features are always blended, preventing Doppler studies. The PHASES measurements and radial velocities (when available) have been combined with lower precision single-aperture measurements covering a much longer time frame (from eyepiece measurements, speckle interferometry, and adaptive optics) to improve the characterization of the long-period orbits in both binaries. The visual orbits of the short- and long-period systems are presented for both systems and used to calculate two possible values of the mutual inclinations between inner and outer orbits of 152{sup 0} {+-} 12{sup 0} or a less likely value of 31{sup 0} {+-} 11{sup 0} for 63 Gem A and 10.{sup 0}2 {+-} 2.{sup 0}4 or 171.{sup 0}2 {+-} 2.{sup 0}8 for HR 2896. The first is not coplanar, whereas the second is either nearly coplanar or anti-coplanar.

79 ASTRONOMY AND ASTROPHYSICS↗