Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase two”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Continuous liquid-phase synthesis of nickel phosphide nanoparticles in a helically coiled tube reactor

The continuous liquid phase synthesis of nickel phosphide (Ni 2 P) nanoparticles was studied in a helically coiled tube (HCT) reactor both in single-phase and two-phase slug flows. The reactants were nickel acetylacetonate and tri-n-octylphosphine (TOP) in a 1-octadecane solvent. For the single-phase mode, various parameters such as reaction temperature, residence time, TOP concentration, and P/Ni ratio were studied. It was found that lower temperatures of 320 and 340 °C resulted in the formation of mixed Ni 12 P 5 and Ni 2 P phases, while a higher temperature of 360 °C gave mostly Ni 2 P, with particle sizes increasing from 28 to 42 nm. Upon varying the contact time between 88 and 340 s at 360 °C, a likely sequence of reaction involved an amorphous phase that was transformed in parallel to Ni, Ni 12 P 5 , and Ni 2 P. When the flow in the HCT was changed to a two-phase slug flow by using N 2 to split the continuous liquid phase into small liquid columns, the product was nearly 100% Ni 2 P and the particle size was as small as 3–4 nm. This was attributed to the enhanced mass transfer in the small liquid columns of the slug flow that led to higher reaction rates. Finally, it is highlighted that the HCT operated in a slug flow is an efficient and continuous method for the fabrication of nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow Boiling Heat Transfer Characteristics of Water for Metal-foam-filled Horizontal Tubes

The goal of this paper is to enhance the in-tube flow boiling heat transfer of water while accounting for potential increase in pressure drop. Metal foams are a class of cellular structure with large surface-area-to-volume ratio and tortuous structure which has shown promising results for various energy conversion and storage applications. The higher heat transfer area and higher nucleation sites density due to the porous media can effectively enhance the heat transfer of water in both single-phase and two-phase operations. This paper presents the local heat transfer and pressure drop measurements of water in a partially metal-foam-filled horizontal copper tube. The ranges of parameters in the experiments are: mass flux from 80 to 200 kg/s-m2, heat flux from 3.5 to 105 kW/m2, and vapor quality from subcooled to 0.3. The results in the metal-foam-filled tube are compared with that of the bare copper tube. The effect of metal foam on the thermal hydraulic characteristics is discussed and analyzed. In addition, the two-phase flow behavior in a transparent tube filled with the same metal foam was visualized and investigated by high-speed imaging system. The experiments were also conducted in the tube without the metal foam for comparison.

Nawaz, Kashif↗

Interface pinning causes the hysteresis of the hydride transformation in binary metal hydrides

Hydriding and dehydriding transitions in bulk and nanocrystalline binary metal hydrides were studied using the Pd-H model system by measuring pressure-composition isotherms with in situ x-ray diffractometry. Nanocrystalline Pd showed a smaller pressure hysteresis, solvus hysteresis, and hysteresis in lattice parameter, compared to bulk Pd. The time-dependence of pressure equilibration was measured after dosing with aliquots of hydrogen, giving equilibration times that were much faster in the single-phase regions than in the two-phase plateaus. In the broad two-phase plateaus, the pressure relaxations were exponential functions of time. An explanation of hysteresis is developed that is based on a dissipative potential barrier that impedes the motion of the interface due to interactions between lattice defects and the two-phase interface. The exponential pressure relaxations and hysteresis are consistent for this mechanism. For a simple model of the pinning potential, the potential barrier maximum is an order of magnitude less than typical grain boundary energies. These pinning effects are substantially different in the nanocrystalline Pd, suggesting differences in the hydriding mechanism.

36 MATERIALS SCIENCE↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Studies toward the Use of Ionic Liquids and Supercritical CO 2 for the Recovery and Separation of Praseodymium from Waste Streams

Waste streams from the incineration of metal-containing materials like such as computer processor boards and batteries may contain critical rare earth elements like praseodymium. Data on the solubility of Pr compounds and on their distribution coefficients in supercritical CO 2 /ionic liquid two-phase systems are important to determine if an ionic liquid/supercritical CO 2 two-phase approach is feasible toward the recovery of a particular metal. This work provides data on the solubility of various praseodymium compounds in butyl-methyl-pyrrolidinium bis(trifluoromethylsulfonyl)imide (BMPyTf2N) ionic liquid and on the distribution coefficients of these praseodymium compounds in the supercritical CO 2 phase of the two-phase BMPyTf2N ionic liquid/supercritical CO 2 system, with and without a tributyl phosphate additive.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Nanorod Assembly and Dynamics in Polymer Nanocomposites in Equilibrium and Shear

Coarse-grained molecular dynamics simulations are used to examine the structure and dynamics of nanorod assemblies in polymer melts under equilibrium and simple shear. We show that as the concentration of nanorods increases, there is a transition from an isotropic phase to a two-phase region in which the nanorods phase separate into a dilute phase and dense bundles of hexagonally packed nanorods. The onset of the two-phase region is below that predicted by Onsager theory, which we attribute to an effective increase in the diameter of nanorods due to a layer of polymer bound to the rod surfaces. Equilibrium simulations show that increasing polymer chain length N enhances nanorod bundling at fixed nanorod concentration. Simulations of systems undergoing simple shear show that flow enhances nanorod alignment and bundling relative to those of equilibrium systems with similar properties. Finally, simulations reveal that increasing nanorod length enhances nanorod alignment under shear at equivalent shear rates but not at equivalent Péclet numbers. Overall, our simulations highlight that polymer matrix-nanorod attraction (i.e., chemistry), shear rate, and matrix chain length are desirable design variables to control the structure of nanorod-containing soft materials under simple shear.

diffusion↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Spectrally Stabilized Interface Capturing Formulation and Implementation in Nek5000/NekRS

This report documents the formulation of a novel level-set method for incompressible two-phase flows in the continuous Galerkin (CG) high order spectral element framework. The overall method hinges on a novel implementation of the spectral vanishing viscosity (SVV) operator for the stabilization of linear/non-linear hyperbolic problems. The multidimensional SVV convolution kernels, which in essence, have a similar effect as a high pass filter applied to the derivatives, are formulated by exploiting the tensor product form, analogous to the construction of the usual stiffness matrix system. The resulting kernels are directionally decoupled and ensure a linear, symmetric positive definite, elliptic matrix operator. The SVV formulation is demonstrated to provide a robust stabilizing mechanism through challenging linear and non-linear hyperbolic problems, including problems pertinent to the level-set formulation. The two-phase framework conceptualized herein is based on the conservative level-set (CLS) method which represents the interface between the fluids by the 0.5 iso-contour of the smoothed Heaviside function. The CLS method is augmented with a preconditioning procedure for interface normals using the signed distance function which precludes the manifestation of spurious oscillations in the vicinty of the interface. Further, the existing mixed explicit-implicit approach for the solution of Navier-Stokes equations in Nek5000, as described in Tomboulides et al, is augmented with a pressure coefficient splitting approach for the Poisson equation, which greatly accelerated the convergence of pressure solver for two-phase systems with large density ratio. The robustness and accuracy of the overall two-phase method is demonstrated through canonical challenging problems involving high density and viscosity ratios, with and without surface tension. The two-phase formulation is wholly implemented in Nek5000 and the SVV stabilization method is implemented in NekRS, which is the essential precursor to the two-phase framework, undergoing active development.

97 MATHEMATICS AND COMPUTING↗

A density functional theory and neutron diffraction study of the ambient condition properties of sub-stoichiometric yttrium hydride

Several mechanical and thermophysical properties are required as a function of non-stoichiometry for the successful implementation of YH 2-x for nuclear reactor moderator applications. Density functional theory calculations, in combination with neutron diffraction experiments, were used to study the structural and mechanical properties of YH 2-x . Point defect analysis indicated H occupation primarily at the tetrahedral site within an fcc Y sub-lattice, confirming a fluorite YH 2 structure. The small positive formation energy for H vacancies under Y-rich conditions predicted that hypo-stoichiometry is accommodated by Y+YH 2 at ambient conditions and by H vacancies in the YH 2-x single phase that is relevant to high temperatures. Neutron diffraction studies were used to confirm both the occupation of H on tetrahedral sites and the near-stoichiometric composition of the hydride phase in the two-phase Y+YH 2 region of the phase diagram that dominates at room temperature. Energy minimized special-quasirandom-structures of H vacancies were used to calculate lattice parameters, elastic constants, and several other properties as a function of composition for the single phase YH 2-x . The lattice parameter of YH 2-x decreased by only 0.004 Å with increasing H/Y for the range 1.31 ≤ H / Y ≤ 2.0 indicating a negligible effect on lattice parameters due to vacancy formation. In the two-phase region, however, calculations predicted the density of z Y + ( 1 - z ) Y H 2 - x to increase with decreasing H/Y at lower temperatures due to the increased fraction of high-density Y metal. Additionally, for the high temperature single phase, decreasing H/Y reduced the density as a consequence of the lattice expansion associated with vacancy formation. All elastic constants and moduli increased with increasing hydrogen content in single-phase YH 2-x .

36 MATERIALS SCIENCE↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pioneer WEC concept design report

The "Pioneer WEC" project is targeted at developing a wave energy generator for the Coastal Surface Mooring (CSM) system within the Ocean Observatories Initiative (OOI) Pioneer Array. The CSM utilizes solar photovoltaic and wind generation systems, along with rechargeable batteries, to power multiple sensors on the buoy and along the mooring line. This approach provides continuous power for essential controller functions and a subset of instruments, and meets the full power demand roughly 70% of the time. Sandia has been tasked with designing a wave energy system to provide additional electrical power and bring the CSM up-time for satisfying the full-power demand to 100%. This project is a collaboration between Sandia and Woods Hole Oceanographic Institution (WHOI), along with Evergreen Innovations, Monterey Bay Aquarium Research Institute (MBARI), Eastern Carolina University (ECU), Johns Hopkins University (JHU), and the National Renewable Energy Laboratory (NREL). This report captures Phase I of an expected two phase project and presents project scoping and concept design results.

16 TIDAL AND WAVE POWER↗

ANTS

The ANTS code (Alternate Non-Linear Two-phase Solver) is based on a novel non-linear solution algorithm for the solution of the two-phase, subchannel fluid equations. It achieves its performance through decoupling of the two-phase momentum equations (axial and transverse) from the axial phasic mass and energy equations which allows for a nested non-linear iteration scheme. This enables a plane-by-plane solution which the inner iteration focuses on a reduced non-linear equation set for the primitives in phasic mass flow rate, enthalpy and void for each node edge. Single node edges are coupled as part of the outer iteration via surface mass fluxes which appear as source terms in the inner iteration scheme. The outer iteration readily accommodates two-phase flow phenomena closure relationships for subchannel mixing and void drift. A primary feature is the use of a non-staggered mesh computational mesh and steady-state iterative solver in contrast to all existing subchannel codes.

Kropaczek, David J↗

Loop Thermosyphon Enhanced Solar Collector

A two-phase loop thermosyphon solar collector was developed to transfer thermal energy efficiently and passively from a concentrated solar collector to a thermal desalination process. The two-phase flow in the loop thermosyphon is driven by a difference in gravitational pressure head between the liquid return line and the two-phase riser located between the evaporator and condenser. A numerical model incorporating mass, energy, and pressure drop balances was developed to predict system performance and use as a design tool. Three iterations of loop thermosyphon solar collectors were designed, fabricated, and tested to validate the numerical analysis and demonstrate system integration. Additionally, a novel solar receiver design was evaluated based on volumetric absorption of the concentrated sunlight by an optically absorptive two-phase working fluid. Life tests were performed to evaluate the working fluid thermal stability and resistance to ultraviolet degradation. A glass receiver tube and associated glass-to-metal junctions were developed. Finally, a full-scale loop thermosyphon was integrated with a parabolic trough solar collector and tested on-sun.

14 SOLAR ENERGY↗

Environmental life cycle assessment of treatment and management strategies for food waste and sewage sludge

A consequential life cycle assessment (LCA) was utilized to compare the environmental impacts of food waste and sewage sludge management strategies. The strategies included a novel two-phase anaerobic digestion (AD) system and alternatives including landfill, waste-to-energy, composting, anaerobic membrane bioreactor, and conventional AD (wet continuous stirred-tank reactor [CSTR]). The co-management of food waste with sewage sludge was also considered for the two-phase AD system and for a conventional AD reactor. Further, a multidimensional LCA approach was taken, considering the five-midpoint impact categories of global warming, smog, human health particulate, acidification, and eutrophication estimated using the U.S. EPA Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts. Co-management of food waste and sewage sludge using the novel two-phase AD system was shown to maximize energy recovery and had a net global warming benefit while reducing other environmental impacts compared with the alternative management strategies. It had similar relative environmental advantages across all categories as conventional AD, with the advantage of a smaller physical footprint. However, both approaches featured net environmental burdens when the background electric grid intensity fell below 0.25 kg CO 2 -eq kWh -1 , as could be expected in a decarbonized electric future. Upgrading the biogas produced from AD to renewable natural gas can displace the use of fossil natural gas for other non-electricity energy requirements that are difficult to decarbonize and may extend the time period of significant environmental benefits of utilizing AD for organic waste management. Treatment of the nutrient-rich supernatant generated by the novel two-phase AD system could be an obstacle for utilities with stringent nutrient discharge limits. Future research and full-scale implementation are needed to demonstrate the benefits of the two-phase AD system predicted through this analysis.

54 ENVIRONMENTAL SCIENCES↗

Towards understanding the development and characteristics of under-expanded flash boiling jets

Here in this research, the n-hexane jets discharged from a straight channel were studied numerically to reveal the development and characteristics of under-expanded flashing jets. Firstly, the development of flash boiling jets was investigated and compared to that of two-phase jets without phase transition. It was shown that the two-phase jets without phase transition can be under-expanded only if the flow is choked. In contrast, flash boiling jets can be under-expanded whether or not the choked conditions are verified. Secondly, the factors affecting the flashing jet behaviors were discussed. The relaxation time in phase transition, the expansion ratio, and the injection pressure have been identified as three key factors determining the jet characteristics. With high enough expansion ratio and low enough relaxation time, the expansion was so strong that the flow became transonic and shock structures similar to those of under-expanded gaseous jets appeared near the orifice exit. Finally, two types of choking have been identified for flash boiling jets, i.e., vaporization-induced choking and expansion-induced choking. The former one is mainly ascribed to the vapor formation in the orifice which reduces the local speed of sound, while the latter one is due to the expansion of under-expanded two-phase flow and the resultant flow acceleration.

42 ENGINEERING↗

FY-24 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the computational modeling of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY24. This year’s modeling campaign focuses on the continual testing of the RELAP5 model against experimental data. Several fault cases were simulated with the RELAP5 model in FY23 to study the accuracy of the model under complex flow conditions. Similarly, in FY24, a case is simulated where the chimney outlet is throttled with a valve while the flow is undergoing two-phase oscillations. The purpose of this case is to study the effects of increasing pressure drop in the two-phase region on the system behavior. Even though the model is able to capture the experimental data qualitatively, it overpredicts the pressure drops experienced by the flow in the two-phase regime. Nevertheless, the model and the experiment show that oscillations are stabilized with increased pressure drop in the two-phase region.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

Symmetric Mass Generation with Four SU(2) Doublet Fermions

We study a single exactly massless staggered fermion in the fundamental representation of an SU(2) gauge group. We utilize an nHYP-smeared fermion action supplemented with additional heavy Pauli-Villars fields that serve to decrease lattice artifacts. The phase diagram exhibits a clear two-phase structure with a conformal phase at weak coupling and a novel new phase, the symmetric mass generation (SMG) phase, appearing at strong coupling. The SMG phase is confining with all states gapped and chiral symmetry unbroken. Our finite size scaling analysis provides strong evidence that the phase transition between these two phases is continuous, which would allow for the existence of a continuum SMG phase. Furthermore, the renormalization group flows are consistent with a 𝛽 function that vanishes quadratically at the new fixed point, suggesting that the 𝑁 𝑓 = 4 flavor SU(2) gauge theory lies at the opening of the conformal window.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗