At least 181 records · Page 10

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

One Year of Rayleigh Lidar Measurements at Toronto

The Rayleigh lidar technique is being used at York University to study middle atmospheric thermal structure with particular emphasis on the properties and influence of internal gravity waves. These measurements are now carried out on a routine basis (every clear night) in order to determine seasonal variability and, eventually, long term trends. The transmitter consists of a doubled Nd:YAG laser with an output of 0.4 Joules per pulse at 20Hz (8 Watts) which is expanded to obtain a divergence of 0.4 milliradians. Backscattered photons are collected by a half meter cassegrain telescope, filtered to a bandwidth of 1nm, detected by a PMT, and counted with a multi-channel scaling averager. Strong backscatter from lower altitudes is blocked using a rotating chopper (25000rpm) which triggers the laser. The range gate and hardware averaging interval are variable but typically 300m and 5 minutes. Relative density profiles are obtained by simply normalizing to a model (eg. CIRA) at some altitude. Absolute temperature is derived using the hydrostatic equation, ideal gas law, and a model pressure value at the altitude where the photocount statistical uncertainty is about 15 percent - typically 90km for the entire night's average. The lower limit is currently about 30-35km due the presence aerosol from the volcanic eruption of Mt. Pinatubo.

Whiteway, James A.↗

Dark counts in optical superconducting transition-edge sensors for rare-event searches

Superconducting transition-edge sensors (TESs) are a type of quantum sensor known for their high single-photon detection efficiency and low background. This makes TESs ideal for particle-physics experiments searching for rare events. In this work, we present a comprehensive characterization of the background in optical TESs, distinguishing three types of events: electrical-noise, high-energy, and photonlike events. We introduce computational methods to automate the classification of events. We experimentally verify and simulate the source of the high-energy events. We also isolate the photonlike events, the expected signal in dielectric haloscopes searching for dark-matter dark photons, and achieve a photonlike dark-count rate of 3.6× 10 − 4 in the 0.8–3.2 eV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation of gamma-ray burst source count statistics

Ever since the discovery of gamma-ray bursts, the so-called log N-log S relation has been used for determination of their distances and distribution. This task has not been straightforward because of varying thresholds for the detection of bursts. Most of the current analyses of these data are couched in terms of ambiguous distributions, such as the distribution of Cp/Clim, the ratio of peak to threshold photon count rates, or the distribution of V/Vmax = (Cp/Clim) exp -3/2. It is shown that these distributions are not always a true reflection of the log N-log S relation. Some kind of deconvolution is required for obtaining the true log N-log S. Therefore, care is required in the interpretation of results of such analyses. A new method of analysis of these data is described, whereby the bivariate distribution of Cp and Clim is obtained directly from the data.

Petrosian, Vahe↗

Observations of the high latitude far ultraviolet background in the 1040-1080 A band

Observations of the far ultraviolet background at high galactic latitudes in a band from 1040-1080 A were carried out with a rocket-borne 1 meter telescope and a 0.23 square degree field of view photometer. The photometer had a sharp cutoff shortward of 1040 A and a sensitivity at hydrogen Lyman alpha of a factor of 0.0001 below its sensitivity at 1060 A. A second photometer monitored geocoronal hydrogen Lyman alpha emission enabling an accurate evaluation of counts due to this background. The hydrogen Lyman alpha flux contributed only 17 percent of the total counts detected in the cosmic background detector. An upper limit to the emission in the 1040-1080 A band of 9700 photons per sq cm-s-sr-A is obtained. This upper limit is compared with previous measurements and theoretical predictions.

Bixler, J.↗

Lithium-niobate-on-insulator waveguide-integrated superconducting nanowire single-photon detectors

Here, we demonstrate waveguide-integrated superconducting nanowire single-photon detectors on thin-film lithium niobate (LiNbO 3 , LN). Using a 250 μm-long NbN superconducting nanowire lithographically defined on top of a 125 μm-long LN nanowaveguide, an on-chip detection efficiency of 46% is realized with simultaneous high performance in dark count rates and timing jitter. As LN possesses high χ (2) second-order nonlinear and electro-optic properties, an efficient single-photon detector on thin-film LN opens up the possibility to construct a small-scale fully integrated quantum photonic chip, which includes single-photon sources, filters, tunable quantum gates, and detectors.

42 ENGINEERING↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A flash photolysis-resonance fluorescence study of the formation of O/1D/ in the photolysis of water and the reaction of O/1D/ with H2, Ar, and He

The technique employed in the study utilizes the vacuum ultraviolet flash photolysis of H2O combined with time resolved, simultaneous detection of H and O via resonance fluorescence at 121.6 and 130.2 nm respectively. The measurements were made by means of photon counting and multichannel scaling. The sensitivity of the system for H and O is discussed. Experiments are reported in which signals due to H and O were accumulated from the flash photolysis of a mixture of 0.1 torr H2O and 100 torr Ar. Attention is given to the relative importance of two primary processes in the photolysis of water.

Stief, L. J.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

EUV emission from a sample of Active Galactic Nuclei

Active Galactic Nuclei (AGN) emit a substantial fraction of their total radiated power in the EUV passband, because spectroscopically this band is situated at or near the peak of the 'big blue bump,' which is bounded on either side by the UV and soft X-ray excesses. Owing to the lack of observational data, the shape of AGN spectra in the EUV is not well known. This paper presents broad band (65-190 eV) count rates of 11 AGN detected by the Extreme Ultraviolet Explorer (EUVE). Assuming a power law spectral shape for the EUV and soft X-ray energies, we demonstrate that the photon indices of the sources are considerably steeper than typical AGN indices. For 6 sources where ROSAT data are available to provide a more precise determination of their spectral parameters in the 0.1-2.5 keV range, we have used these parameters to compute predicted EUVE count rates and compared them with the observed values. The two sets of quantities agree to within experimental error. We conclude that there is no evidence of spectral steepening or turn-over of the soft X-ray excess at EUV wavelengths for a sample of AGN which covers a wide range of brightness.

Lieu, R.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.↗

Optical Array Versus Monolithic Telescope Ground Station Cost Assessment

The purpose of this study is to outline the design of an optimal array of optical telescopes to emulate performance of a monolithic 12 m telescope in support of deep-space communications. In this case, optimal means minimizing the initial capital investment and operational cost while maintaining performance requirements of the deep-space link. The design is approached from a practical, engineering perspective. Pulse position modulation (PPM) signal formatting and photon counting detectors are assumed at each telescope in the array. That is, the telescopes function as so-called light buckets, so direct detection (as opposed to coherent reception) of the received signals is assumed, and there is no intention to consider active compensation for atmospheric turbulence-induced phase fluctuations. A parametric analysis among aperture size, detector size, and primary mirror surface quality, in the context of field-of-view expansion, is presented to minimize the cost function.

Romanofsky, Robert R.↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

Development of a Rayleigh Scattering Diagnostic for Time-Resolved Gas Flow Velocity, Temperature, and Density Measurements in Aerodynamic Test Facilities

A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded turbulent flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultiplier tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. An acoustically driven nozzle flow is studied to validate velocity fluctuation measurements, and an asymmetric oscillating counterflow with unequal enthalpies is studied to validate the measurement of temperature fluctuations. Velocity fluctuations are compared with constant temperature anemometry measurements and temperature fluctuations are compared with constant current anemometry measurements at the same locations. Time-series and power spectra of the temperature and velocity measurements are presented. A numerical simulation of the light scattering and detection process was developed and compared with experimental data for future use as an experiment design tool.

Mielke, Amy F.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

The X-Ray Variable Sky

A novel approach to search for rapid time variability of every source, whether persistent or transient, within the entire ROSAT detector field has been developed. Semi-automated software statistically tests the photon arrival time event list for source variability and reports significant (greater than 5 sigma) variable enhancement in the photon count rate on time scales ranging from 5-500 seconds. The computational algorithms have been thoroughly tested, and are able to discriminate between false detections induced by instrumental effects, and real X-ray variable sources (XRVs); when carefully scrutinized by the PI. The analysis has proven to be successful, with both periodic and transient XRVs having been found. Some of these are entirely new discoveries, while others have been detected in previous X-ray missions, yet their nature remained elusive since source identification and analysis had yet to be performed. On average, one new (unidentified) XRV is found per ROSAT PSPC field analyzed. In some cases the XRVs show only a transient signature (a burst type event) with no persistent X-ray or other known (optical) counterpart. The ambitious goal of this project was to process as much of the ROSAT PSPC archive data as feasibly possible to discover XRVs and analyze this data.

Stringfellow, Guy↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗