Development and Application of a Risk Analysis Toolkit for Plant Resources Optimization

This report summarizes the R&D activities of the Risk Informed Asset Management (RIAM) project during fiscal year 2020 (FY20). This project focuses on the development of methods designed to optimize plant operations (e.g., maintenance/replacement schedule, optimal maintenance posture) provided system/component health/cost data. This project development lives in cooperation with the Plant Health Management (PHM) project which focuses on the development of methods that integrate component health data and propagate such information at the system level to evaluate most relevant sources of risk. This year’s activities for the RIAM project focused on the continuation of schedule optimization algorithms developed in FY19. While in FY19 we focused on both deterministic and stochastic capital budgeting methods, in FY20 we moved forward by implementing two versions of schedule optimization methods. The first one reformulates the capital budgeting problem in a distributionally robust form which allows the user to rely on data directly rather than proposing a distribution from the data itself. The second version reformulates the capital budgeting explicitly using risk measures as variables to maximize/minimize. Lastly, we focused on the development of methods designed to identify the optimal maintenance posture based on the Pareto Frontier analysis. Rather than performing a tradeoff analysis (i.e., identify the absolute best posture), the Pareto Frontier analysis performs a trade space exploration approach (i.e., identify value and costs of several postures and have the analyst perform the task of imposing desired value and cost constraints). This is performed by identifying maintenance postures that maximize value (e.g., system availability) and minimize operational costs, i.e., the Pareto frontier in a value-cost trade space.

97 MATHEMATICS AND COMPUTING↗

Concentrating Solar Power Best Practices Study

The primary objective of this Concentrating Solar Power Best Practices Study is to publish best practices and lessons learned from the engineering, construction, commissioning, operations, and maintenance of existing concentrating solar power (CSP) parabolic trough and power tower systems. To accomplish this objective, information was solicited from many owners, operators, and engineering, procurement, and construction (EPC) contractors, independent engineers, and other stakeholders of parabolic trough and central receiver plants (also commonly referred to as power towers). Information was gathered through in-person or online meetings, site visits, and questionnaires sent to participants. The project team held about 50 information-gathering sessions with participants over the course this effort; and in the process, it collected information from participants representing nearly 80% of CSP plants operating worldwide.

14 SOLAR ENERGY↗

A Simple Program to Estimate the Fast Modular Reactor Steady-State Closed Brayton Cycle Operating Parameters

The Fast Modular Reactor (FMR) is a gas-cooled fast reactor (GFR) that produces a net electricity output of 50 MW with helium-driven closed Brayton cycle. The power plant includes reactor system and power conversion unit (PCU). The reactor system produces fission energy that is transferred by helium flow. The PCU consists of a turbine, two compressors, and three heat exchanges. More specifically, the recuperator is a counter-flow energy recovery heat exchanger. The precooler and intercooler are the heat sinks. To analyze and understand the sensitivity of plant performance to the design parameters, a numerical program was written to calculate the plant operating parameters represented by the helium temperature, pressure, mass flow, and the heat sink temperatures. The program was developed for the steady-state operating condition. etc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Reduced Glass Furnace Model to Optimize Process Operation

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and PPG Industries to develop a reduced-order glass furnace model that enables plant operators to make informed, realtime process adjustments. This CRADA project is sponsored under the High-Performance Computing for Manufacturing (HPC4Mfg) Program of the Department of Energy's Advanced Manufacturing Office (AMO) within the Energy Efficiency and Renewable Energy (EERE) Office. This program ran from June 2016 to July 2017 with no extensions.

42 ENGINEERING↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Application of Cable Condition Monitoring Technologies to Assess Age-Related Degradation of Industrial Cables Installed in Harsh Environments

The aging of electrical cables has been the subject of substantial research and development (R&D) projects performed by national and international laboratories, universities, and private organizations for many years. This R&D was conducted to develop guidance, equipment, and techniques to support aging management of in-service cables in industrial facilities such as nuclear power plants, research reactors, waste facilities, and fuel fabrication plants. Through these research efforts, condition monitoring technologies have been developed that can determine the severity of age-related degradation that occurs in industrial cables and insulation polymers during service. This paper summarizes the results of aging assessments that were performed for cables installed in two U.S. nuclear power plants, one a pressurized water reactor and one a boiling water reactor. These cables had been in service for over 40 years and during plant operation were exposed to harsh environmental conditions including elevated temperatures and radiation. For these assessments, a comprehensive series of measurements was performed to assess the aged condition of the cables. These cables came from different manufacturers, were manufactured in different years, and were constructed with a variety of jacket and insulation polymers including chloro-sulfonated polyethylene (CSPE), cross-linked polyethylene (XLPE)/cross-linked polyolefin (XLPO), neoprene, and ethylene propylene rubber (EPR). The goal of these assessments was to determine the current aged condition of the cable polymers and provide an estimate of how long the cable insulation materials could remain exposed to their in-service environmental conditions before reaching their end-of-life condition. Both nuclear power plants have received license renewals to extend their operation from 40 to 60 years, and the utilities need objective evidence to show that critical components such as cables will be able to function safely and reliably during the extended operating period. Furthermore, the results of these assessments showed that the cables exhibited different aged conditions depending on the type of polymers they were constructed with and the environment they were exposed to during service. Some of the cables and insulation polymers showed signs of significant age-related degradation and were estimated to have approximately 5 years of remaining service life. Other cables exhibited no signs of significant age-related degradation and were estimated to have 50 years or more of remaining service life. Using the results of these cable aging assessments, plant personnel were able to (1) determine the overall aged condition of cables and insulation polymers using objective test results, (2) identify aged or degraded cables before they caused operability issues, and (3) avoid unnecessary and costly replacement of cables that can continue to operate safely and reliably.

36 MATERIALS SCIENCE↗

Modeling and Analysis of Wind Turbine Wake Vortex Evolution Due to Time-Constant Spatial Variations in Atmospheric Flow

Modern utility-scale wind turbines are evolving toward larger, lighter, and more flexible designs to meet the growing demand for renewable energy while minimizing logistical costs. However, these advancements in lightweight design result in heightened aeroelastic sensitivity, leading to complex interactions which affect the rotor’s capacity to withstand aerodynamic loading and the cascading effects that manifest in the wake’s vortex-structure evolution under variable atmospheric conditions. In this paper, we analyze the influence of stream-wise fluctuating atmospheric flow conditions on wind turbines with large, flexible rotors through simulations of the National Rotor Testbed (NRT) turbine, located at Sandia National Labs’ Scaled Wind Farm Technology (SWiFT) facility in Lubbock, Texas. The Common Ordinary Differential Equation Framework (CODEF) modeling suite is used to simulate wind turbine aeroelastic oscillatory behavior and wind farm vortex–wake interactions for a range of conditions with spatially variant atmospheric flow. CODEF solutions for turbine operation in wind conditions featuring only one parameter fluctuation are compared to wind conditions with several wind parameter variations in combination. By isolating individual inflow variations and comparing them to multi-parameter scenarios, we determine the contributions of each atmospheric factor to rotor dynamics, wake evolution, and downstream wind farm interactions. The purpose of this paper is to analyze the effects of spatial variations in atmospheric flow on the topological evolution of wind turbine vortex wakes, which constitutes a gap in the current understanding of wind turbine wake dynamics. The insights gained from this study are particularly valuable for the development of wind farm control strategies aimed at mitigating the adverse effects of wake interactions, enhancing energy capture, and improving the overall stability of wind farm operations. With these insights, we aim to contribute to the development of modeling and simulation tools to optimize utility-scale wind power plants operating in diverse atmospheric environments.

Farrell, Alayna (ORCID:000000023555720X)↗

Towards a Deeper Understanding of Automation Transparency in the Operation of Nuclear Plants

Automation technologies have the potential to reduce operations and maintenance costs, ensure reliable power generation and safety, and thereby contribute to extending the lifespan of nuclear power plants. To fulfill this aspiration, automation behaviors have to be understandable and predictable to human operators and traceable for license holders and regulators in the event of automation failures. The current report investigates how automation transparency as a systems design principle can keep operators sufficiently informed about the inner workings of automation or make fail-safe automation run invisibly in the background to free up operator capacity.

99 GENERAL AND MISCELLANEOUS↗

Development of an In-Situ Method for Cable Condition Monitoring in Nuclear Power Plants (SBIR Phase IIB Final Report)

This is the final report of a Small Business Innovation Research (SBIR) project that Analysis and Measurement Services Corporation (AMS) has conducted for the U.S. Department of Energy (DOE) over a seven-and-a-half year period (February 2013 through April 2020 with the awards of Phase I, Phase II and Phase IIB projects). The goal of the project was to design, develop, validate, and demonstrate a technique for in-situ testing of cable insulation polymers that will identify, locate, and provide the degree of aging for cables commonly used in nuclear power plants. During the Phase I project, AMS established that the frequency domain reflectometry (FDR) technique can successfully identify and measure cable insulation degradation that can be trended with aging. In Phase II, AMS performed extensive cable aging studies to correlate FDR measurements with other laboratory condition monitoring techniques and developed aging condition categories to quantify the severity of insulation degradation. In Phase IIB, the project expanded the research to include a wider variety of cable polymers that are used in the commercial nuclear power industry. This work also involved developing acceptance criteria to objectively assess age-related cable degradation while sharing the results of this research with industry, academia, and national laboratories to advance the state of the art in cable aging management technologies. The products developed under this research project provide the nuclear industry with an effective condition monitoring tool to support safe and long-term plant operation. Throughout the project, collaborations and support were received from a variety of industry organizations and individuals including DOE National Laboratories as well as nuclear plant utilities and several other industry experts and cable manufacturers. Contributions from these organizations included the donation of new cables, naturally aged cables, and research collaboration. The validation and commercialization of the products of this project were achieved through opportunities to test and demonstrate the technologies’ capabilities on-site at nuclear power generation and research facilities as well as in the laboratory alongside industry peers and cable testing service companies. The research resulted in a technology that can be used to identify, locate, and quantify age-related degradation in several types of cable polymers. This included developing software and hardware as well as the methodology for using the FDR technique to assess age-related degradation of installed cables. The technology developed under this project can provide nuclear plant management, engineers, and technicians with an in-situ electrical test method to determine if in-service cables need to be replaced, monitored on a periodic basis, or show no evidence of significant age-related degradation that may require action. Near the end of this Phase IIB project, the FDR product was sold to a nuclear power utility in South Korea. This sale of a dedicated aging assessment tool is the beginning of a comprehensive contract with the expectation of twelve (12) units sold to that country. Additionally, the FDR technology has been sold to several industry organizations including a nuclear research institute and the Diablo Canyon nuclear power plant. This technology is also being leased by other nuclear industry service companies for incorporation into aging management programs. The cable testing technology that was developed under this project was also integrated into a comprehensive cable aging assessment service that is being offered to the nuclear industry at the request of U.S. nuclear utilities and is currently part of onsite testing services provided by AMS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Confinement performance predictions for a high field axisymmetric tandem mirror

This paper presents a Hammir tandem mirror confinement performance analysis based on Realta Fusion’s first-of-a-kind model for axisymmetric magnetic mirror fusion performance. This model uses an integrated end plug simulation model including, heating, equilibrium and transport combined with a new formulation of the plasma operation contours (POPCONs) technique for the tandem mirror central cell. Using this model in concert with machine learning optimization techniques, it is shown that an end plug utilizing high temperature superconducting magnets and modern neutral beams enables a classical tandem mirror pilot plant producing a fusion gain Q > 5. The approach here represents an important advance in tandem mirror design. The high-fidelity end plug model enables calculations of heating and transport in the highly non-Maxwellian end plug to be made more accurately. The detailed end plug modelling performed in this work has highlighted the importance of classical radial transport and neutral beam absorption efficiency on end plug viability. The central cell POPCON technique allows consideration of a wide range of parameters in the relatively simple near-Maxwellian central cell, facilitating the selection of more optimal central cell plasmas. These advances make it possible to find more conservative classical tandem mirror fusion pilot plant operating points with lower temperatures, neutral beam energies and end plug performance requirements than designs in the literature. Despite being more conservative, it is shown that these operating points have sufficient confinement performance to serve as the basis of a viable fusion pilot plant provided that they can be stabilized against magnetohydrodynamic and trapped particle modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Confinement performance predictions for a high field axisymmetric tandem mirror

This paper presents Hammir tandem mirror confinement performance analysis based on Realta Fusion's first-of-a-kind model for axisymmetric magnetic mirror fusion performance. This model uses an integrated end plug simulation model including, heating, equilibrium, and transport combined with a new formulation of the plasma operation contours (POPCONs) technique for the tandem mirror central cell. Using this model in concert with machine learning optimization techniques, it is shown that an end plug utilizing high temperature superconducting magnets and modern neutral beams enables a classical tandem mirror pilot plant producing a fusion gain Q > 5. The approach here represents an important advance in tandem mirror design. The high fidelity end plug model enables calculations of heating and transport in the highly non-Maxwellian end plug to be made more accurately. The detailed end plug modelling performed in this work has highlighted the importance of classical radial transport and neutral beam absorption efficiency on end plug viability. The central cell POPCON technique allows consideration of a wide range of parameters in the relatively simple near-Maxwellian central cell, facilitating the selection of more optimal central cell plasmas. These advances make it possible to find more conservative classical tandem mirror fusion pilot plant operating points with lower temperatures, neutral beam energies, and end plug performance requirements than designs in the literature. Despite being more conservative, it is shown that these operating points have sufficient confinement performance to serve as the basis of a viable fusion pilot plant provided that they can be stabilized against MHD and trapped particle modes.

FOS: Physical sciences↗

Assessment of the Effect of Prototypic High-Burnup Operating Conditions of Fuel Fragmentation, Relocation, and Dispersal Susceptibility

The US nuclear energy industry is investigating strategies that further reduce the cost of energy production by using its existing fleet of nuclear generating stations. Most nuclear power plant operating costs are associated with purchasing fresh fuel assemblies or the efficiency of the reactor core design. Material costs are typically beyond the operator’s control; however, the core design optimizations offer potential operational savings. The core design envelope available to operators is constrained by two primary regulatory criteria: an enrichment limit of 5% 235 U and a burnup limit of 62 GWD/tU. These constraints have resulted in renewed efforts by the nuclear industry to pursue extending the peak rod-average burnup beyond 62 GWd/tU. This effort will likely require additional safety analyses beyond what is currently accepted by the US Nuclear Regulatory Commission. The purpose of this work is to demonstrate a best estimate plus uncertainty pin-by-pin high-burnup loss of coolant accident analysis technique to assess full-core high-burnup fuel fragmentation, relocation, and dispersal (FFRD) and identify approaches for minimizing or potentially mitigating FFRD through core design optimizations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Atmospheric Grand Challenges in the Science of Wind Energy

Harvested by advanced technical systems honed over decades of research and development, wind energy has become a mainstream energy resource. However, continued innovation is needed to realize the potential of wind to serve the global demand for clean energy. Here, we outline three interdependent, cross-disciplinary grand challenges underpinning this research endeavor. The first is the need for a deeper understanding of the physics of atmospheric flow in the critical zone of plant operation. The second involves science and engineering of the largest dynamic, rotating machines in the world. The third encompasses optimization and control of fleets of wind plants working synergistically within the electricity grid. Addressing these challenges could enable wind power to provide as much as half of our global electricity needs and perhaps beyond.

17 WIND ENERGY↗

A digital twin approach to system-level fault detection and diagnosis for improved equipment health monitoring

Automating the task of fault detection and diagnosis is crucial in the effort to reduce the operation and maintenance cost in the nuclear industry. This paper describes a physics-based approach for system-level diagnosis in thermal-hydraulic systems in nuclear power plants. The inclusion of physics information allows for the creation of virtual sensors, which provide improved fault diagnosis capability. The physics information also serves to better constrain diagnostic solutions to the physical domain. As a demonstration, various test cases for fault diagnosis in a high-pressure feedwater system were considered. The use of virtual sensors allows constructing performance models for two first-point feedwater heaters which would not have been possible otherwise due to the limited sensor set. Real-time plant data provided by a utility partner were used to assess the diagnostic approach. The detection of an abnormal event immediate after a plant startup pointed to faulty behaviors in the two first-point feedwater heaters. Further, this double-blind fault diagnosis was subsequently confirmed by the plant operator. In addition, several simulated sensor fault events demonstrated the capability of our algorithms in detecting and discriminating sensor faults.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wind Turbine Drivetrain Reliability Research - Gearbox Bearing Axial Cracking Failure Mode Example

The U.S. Department of Energy's National Renewable Energy Laboratory and Argonne National Laboratory have been conducting wind turbine drivetrain (formerly gearbox) reliability research for many years. Although the drivetrain focus has not changed, detailed projects are adjusted every few years based on dynamic needs seen in the field across the wind industry. This webinar will walk through the research methodology by using wind turbine gearbox bearing axial cracking failure mode as an example. The detailed steps include: 1) top failure mode identification based on actual failure data collected from project partners, 2) bench-top testing to identify possible contributing factors and formulate a damage metric, 3) physics domain modeling and validation through testing, 4) reliability assessment and prognosis based on the physics domain model and data domain inputs, and further enhancement through machine learning algorithms, using actual wind plant operational and failure event data. Hopefully, the presented work is of interest to the IISE community, and some members can apply their expertise to wind turbine and plant applications, helping enhance wind power generation technology advancement and its broader deployment.

axial cracking↗

Roadmap for Deployment of Modularized Hydrothermal Liquefaction: Understanding the Impacts of Industry Learning, Optimal Plant Scale, and Delivery Costs on Biofuel Pricing

Hydrothermal liquefaction (HTL) is a promising technology for converting abundant organic wastes into fuels. Previous techno-economic analyses (TEAs) of HTL have been used to estimate the minimum fuel selling price (MFSP) of biofuel products, but these analyses often assume a bespoke plant design where each plant operates under unique process conditions and neglect transportation costs. However, transportation costs must be included in realistic TEAs, and further, a mass-produced fixed-scale modular plant design approach may be more effective than case-by-case plant design, provided that there is sufficient market capacity to benefit from modularization. This study estimates fuel price behavior in the presence of transportation costs and benefits stemming from modular plant design. This analysis indicates that a modular process capable of handling 60 dry tons per day (DTPD) is optimal, resulting in a ~25% reduction in MFSP (from $4.70/GGE, fully upgraded) at complete market feedstock utilization compared with case-by-case design. The associated cost reductions are attributable to learning benefits and modularization. Several HTL deployment “roadmaps” are then explored, with each roadmap consisting of different periods of case-by-case design followed by adoption of a modularized approach. A period of nonmodular industry growth up to market saturation of ~7% followed by implementation of modular plant design strikes a balance between the investment risk and learned cost reductions associated with modular plant design. However, if bespoke plants built during this period of nonmodular growth saturate more than 23% of available feedstock, learned cost reductions are significantly diminished. Here, this study points to the potential benefits of modularized and decentralized waste-to-energy processes when the modularization follows an optimal deployment strategy.

09 BIOMASS FUELS↗

Using Current Data to Detect Hardware Faults at Solar Plants

Monitoring amperage data is an effective means of detecting faults in PV plant data. Utilizing amperage data collected at the combiner box gives plant operators an up-to-date list of faulted equipment, allowing them to coordinate maintenance needs at much shorter intervals than previously. Shorter maintenance intervals will increase PV plant production levels, narrowing the gap between expected and actual PV plant performance. The amperage monitoring method performs at a high level, with a string-outage related fault detection True Positive Rate of 46% and False Positive Rate of 8%.

14 SOLAR ENERGY↗

Ship Motion Testing Needs Evaluation

The American Bureau of Shipping performed an evaluation of national maritime nuclear testing capabilities and determined there currently is an inability to test maritime nuclear power plants in a ship motion environment. A Ship Motion Test Facility (SMTF) is proposed to fill this gap. To inform design of this facility, this report documents an evaluation performed by a panel of technical experts that identifies key physical phenomena associated with maritime nuclear power plant operation that are important to safety and reliability and have a low state of knowledge. This evaluation concluded that all of the major test needs to understand a nuclear plant's behavior in a ship motion environment are for thermal-hydraulics related phenomena. Based on this finding, the evaluation panel concluded that the SMTF would not be required to use nuclear fuel to provide a heat source for the fluids. This would significantly decrease the cost, timeline, and complexity for this test facility to enable the advancement of maritime nuclear technology.