Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cold Plasma IC Report

This past year we completed the simulation campaign in support of our magnetospheric cold plasma research project. This project aimed to develop the next-generation particle instruments to measure the properties of the cold particle populations in the Earth’s magnetosphere.

58 GEOSCIENCES↗

Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)

Double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is one of the most important measurement methods in the establishment of measurement standards for inorganic analysis. However, there is still no good consensus on approaches for uncertainty evaluation in double ID-ICP-MS. Particularly, approaches to treating the instrumental isotopic fractionation (IIF) phenomenon and correlation between uncertainty sources are diverse and often unclear in the literature. Here, an approach for uncertainty evaluation in double ID-ICP-MS measurements is described. Using three certified reference materials (CRMs), it is shown that the IIF effects cancel out and should not be included in the uncertainty budget. Further, a consistent way of considering correlated sources of uncertainty to prevent double counting of uncertainties is described in detail along with an example of measuring the mass fraction of magnesium in an oyster powder CRM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for multiple frequency heating and investigation of underlying processes

The development of new facilities routinely challenges ion source designers to build and operate sources that can achieve ever higher beam intensities and energies. As shown in this work, electron cyclotron resonance ion sources have proven to be extremely capable in meeting these challenges through the production of intense beams of medium and high-charge state ions. As performance boundaries are pushed, source stability becomes an issue as does the technology required to meet the challenge. Multiple frequency heating, the simultaneous use of two or more plasma heating frequencies, is a powerful tool in meeting the simultaneous need of intensity and stability. Relatively straightforward to utilize, the technique has been employed at numerous facilities to increase beam current and achievable charge state while also stabilizing the plasma. Its application has expanded the operational boundaries of existing and next generation sources, demonstrating that these devices have not yet achieved their full operational potential. To better understand the underlying physics, the diagnostics used to probe the source operational boundaries and the plasma properties have become increasingly sophisticated. In concert with detailed modeling, they are beginning to provide insight into the heating mechanism and, with that, the prospect of future advances.

47 OTHER INSTRUMENTATION↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

The Critical Need for Innovations in Instruments and Techniques to Enable In-Situ Cold Ion and Cold Electron Measurements within the Magnetosphere

Relatively few studies have focused on the cold plasma populations of the magnetosphere due to difficulties associated with obtaining measurements. The cold particle populations are defined here as those with total energy approximately <100 eV which is an energy range for which measurements are difficult (regardless of species), but which often make up the bulk of the plasma density. These populations have known and suspected impacts on the structure and dynamics of the magnetosphere. Unfortunately, the lack of accurate measurements of the cold ion and cold electron populations through the magnetosphere makes closure of these science questions extremely difficult if not impossible. In a complex system of interconnected parts like the Earth’s magnetosphere, a lack of understanding of one part of the system (the cold electron and ion populations) is disabling. Hence, until cold electron and cold ion measurements are obtained robustly with every mission, the magnetospheric plasma environment cannot be completely understood. This will require innovations in plasma spectrometers and associated techniques required to obtain high-fidelity in-situ measurements of the cold ion and cold electron populations in the magnetosphere. This paper seeks to review the instruments and techniques that have been used to date and present possible options for future missions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of ultrahigh-brightness pre-bunched beams from a plasma cathode for X-ray free-electron lasers

The longitudinal coherence of X-ray free-electron lasers (XFELs) in the self-amplified spontaneous emission regime could be substantially improved if the high brightness electron beam could be pre-bunched on the radiated wavelength-scale. Here, we show that it is indeed possible to realize such current modulated electron beam at angstrom scale by exciting a nonlinear wake across a periodically modulated plasma-density downramp/plasma cathode. The density modulation turns on and off the injection of electrons in the wake while downramp provides a unique longitudinal mapping between the electrons’ initial injection positions and their final trapped positions inside the wake. The combined use of a downramp and periodic modulation of micrometers is shown to be able to produces a train of high peak current (17 kA) electron bunches with a modulation wavelength of 10’s of angstroms - orders of magnitude shorter than the plasma density modulation. The peak brightness of the nano-bunched beam can be $\textit{O}$(10 21 A/m 2 /rad 2 ) orders of magnitude higher than current XFEL beams. Such prebunched, high brightness electron beams hold the promise for compact and lower cost XEFLs that can produce nanometer radiation with hundreds of GW power in a 10s of centimeter long undulator.

47 OTHER INSTRUMENTATION↗

Probing the Magnetosheath Boundaries Using Interstellar Boundary Explorer (IBEX) Orbital Encounters

Inside the magnetosheath, the IBEX-Hi energetic neutral atom (ENA) imager measures a distinct background count rate that is more than 10 times the typical heliospheric ENA emissions observed when IBEX is outside the magnetosheath. The source of this enhancement is magnetosheath ions of solar wind (SW) origin that deflect around the Earth's magnetopause (MP), scatter and neutralize from the anti-sunward part of the IBEX-Hi sunshade, and continue into the instrument as neutral atoms, behaving indistinguishably from ENAs emitted from distant plasma sources. While this background pollutes observations of outer heliospheric ENAs, it provides a clear signature of IBEX crossings over the magnetospheric boundaries. In this study, we investigate IBEX encounters with the magnetosheath boundaries using ~8 yr of orbital data, and we determine the MP and bow shock (BS) locations derived from this background signal. We find 280 BS crossings from X GSE ~ 11 R e to X GSE ~ –36 R e and 241 MP crossings from X GSE ~ 6 R e to X GSE ~ –48 R e . We compare IBEX BS and MP crossing locations to those from IMP-8, Geotail, Cluster, Magion-4, ISEE, and Magnetospheric Multiscale Mission, and we find that IBEX crossing locations overlap with the BS and MP locations inferred from these other data sets. In this paper, we demonstrate how IBEX can be used to identify magnetosheath crossings, and extend boundary observations well past the terminator, thus further constraining future models of magnetosheath boundaries. Furthermore, we use the IBEX data set to show observational evidence of near-Earth magnetotail squeezing during periods of strong interplanetary magnetic field B y .

79 ASTRONOMY AND ASTROPHYSICS↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Autonomous sputter synthesis of thin film nitrides with composition controlled by Bayesian optimization of optical plasma emission

Autonomous experimentation has emerged as an efficient approach to accelerate the pace of material discovery. Although instruments for autonomous synthesis have become popular in molecular and polymer science, solution processing of hybrid materials, and nanoparticles, examples of autonomous tools for physical vapor deposition are scarce yet important for the semiconductor industry. Here, we report the design and implementation of an autonomous workflow for sputter deposition of thin films with controlled composition, leveraging a highly automated sputtering reactor custom-controlled by Python, optical emission spectroscopy (OES), and a Bayesian optimization algorithm. We modeled film composition, measured by x-ray fluorescence, as a linear function of plasma emission lines monitored during co-sputtering from elemental Zn and Ti targets in an N 2 and Ar atmosphere. A Bayesian control algorithm, informed by OES, navigates the space of sputtering power to fabricate films with user-defined compositions by minimizing the absolute error between desired and measured optical emission signals. We validated our approach by autonomously fabricating Zn x Ti 1-x N y films that deviate from the targeted cation composition by a relative ±3.5%, even for 15 nm thin films, demonstrating that the proposed approach can reliably synthesize thin films with a specific composition and minimal human interference. Moreover, the proposed method can be extended to more difficult synthesis experiments where plasma intensity lines depend non-linearly on pressure, or the elemental sticking coefficients strongly depend on the substrate temperature.

36 MATERIALS SCIENCE↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

Monte Carlo Analysis of the Performance of the ITER Diagnostic Residual Gas Analyzer

The composition of exhausted gas is a key parameter in long-pulse plasma fusion experiments, and its evolution shall be monitored at timescales relevant to plasma dynamics and plasma-wall interactions. A diagnostic residual gas analyzer (DRGA) is a multisensor instrument particularly suited to these studies, and ITER will adopt DRGAs in the equatorial and in the divertor tokamak regions. In this work, we have revisited the design of the ITER divertor DRGA through simple vacuum analytical considerations supported by simulations conducted with Molflow+, a test particle Monte Carlo (TPMC) simulation code commonly used in the particle accelerator community. Here, starting with recommendations on the manufacturing of the vacuum piping of the DRGA, this work is followed by a complete vacuum characterization of the diagnostic vacuum setup (pressure profiles at base pressure and during sampling, orifice diameter, and length optimization), and finally, the in-vessel residence time of the most important gas species is simulated. These studies have allowed us to give insights into some experimental results recently found on the prototype DRGA installed in the Wendelstein W7-X stellarator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complex multicomponent spectrum analysis with Deep Neural Network

Here, in this paper, we present the use of deep neural networks to estimate physical parameters from complex optical emission spectra of the D β /H β transition. Specifically, we focus on estimating the radio frequency electric field vector of the lower hybrid wave and isotope ratio within the scrape-off-layer plasma of the WEST tokamak. Fitting the spectral data using a traditional non-linear least squares analysis requires many free parameters and is computationally expensive, rendering the data unusable for real-time control. By implementing relatively small neural networks, the physical parameters can be directly extracted from the spectral data with reasonable accuracy in a few milliseconds. The deep neural network prediction can serve as input for a reduced model using least-squares fitting or for real-time control. We show that deep neural networks can be an effective tool for analyzing complex multicomponent spectra, providing a speedup of more than 10 5 times compared to least residual analysis, with an accuracy of 0.5% for the isotope ratio, and 0.09 kV/cm and 0.38 kV/cm for the RF radial and poloidal electric field respectively.

47 OTHER INSTRUMENTATION↗

Optical spectroscopy and modeling of uranium gas-phase oxidation: Progress and perspectives

We report that studies related to U gas-phase oxidation through plasma- and thermo-chemistry are important for many fields, including environmental monitoring, forensic analysis, debris analysis in a weapon detonation event, and nucleation physics. Recently, significant efforts have been made to understand the chemical pathways involved in the progression from U atoms to diatoms (UO) and polyatomic molecules (UxOy), employing optical spectroscopy tools and computational modeling. In many studies, laser ablation of U or a U-containing flow reactor are used as a highly resource-efficient, repeatable, tunable, and lab-scale testbed for studying gas-phase oxidation in U plasmas. The spectroscopic analysis of high-temperature gas-phase oxidation of U is challenging due to the congested U spectra, resolution limitations of instrumentation, and the numerous chemical reaction pathways possible. This article focuses on the current understanding and challenges related to studying U plasma chemistry, specifically U gas-phase oxidation and molecular formation, via optical spectroscopy of plasmas and associated computational and spectral modeling. The physical and chemical processes involved in the evolution from U atoms to U oxide molecules to nanoparticles and agglomerates (i.e., debris) are discussed in the context of optical spectroscopic studies. The article concludes by highlighting opportunities for future research efforts based on existing knowledge published in the literature.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A confocal laser-induced fluorescence diagnostic with an annular laser beam

Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.

47 OTHER INSTRUMENTATION↗

Large-Scale Interlaboratory DI-FT-ICR MS Comparability Study Employing Various Systems

We report ultra-high resolution mass spectrometry (UHR-MS) coupled with direct infusion (DI) electrospray ionization offers a fast solution for accurate untargeted profiling. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers have been shown to produce a wealth of insights into complex chemical systems because they enable unambiguous molecular formula assignment even if the vast majority of signals is of unknown identity. Inter-laboratory comparisons are required to apply this type of instrumentation in quality control (for food industry or pharmaceutics), large-scale environmental studies or clinical diagnostics. Extended comparisons employing different FT-ICR MS instruments with qualitative direct infusion analysis are scarce since the majority of detected compounds cannot be quantified. The extent to which observations can be reproduced by different laboratories remains unknown. We set up a preliminary study which encompassed a set of seventeen laboratories around the globe, diverse in instrumental characteristics and applications, to analyze the same sets of extracts from commercially available standard human blood plasma and Standard Reference Material (SRM) for blood plasma (SRM1950), which were delivered at different dilutions or spiked with different concentrations of pesticides. The aim of this study was to assess the extent to which the outputs of differently tuned FTICR mass spectrometers, with different technical specifications, are comparable for setting the frames of a future DI-FT-ICR MS ring trial. We concluded that a cluster of five laboratories, with diverse instrumental characteristics showed comparable and representative performance across all experiments, setting a reference to be used in a future ring trial on blood plasma.

47 OTHER INSTRUMENTATION↗

Laser-induced fluorescence of filament-produced plasmas

Self-guided ultrafast laser filaments are a promising method for laser beam delivery and plasma generation for standoff and remote detection of elements and isotopes via filament-induced breakdown spectroscopy (FIBS). Yet, there are several challenges associated with the practical application of FIBS, including delivery of sufficient laser energy at the target for generating plasma with a copious amount of emission signals for obtaining a high signal-to-noise ratio. Here, in this study, we use laser-induced fluorescence (LIF) to boost the emission signal and reduce self-reversal in the spectral profiles. Ultrafast laser filaments were used to produce plasmas from an Al 6061 alloy target at various standoff distances from 1 to 10 m. For LIF emission enhancement, a narrow linewidth continuous-wave laser was used in resonance with a 394.40 nm Al I resonant transition, and the emission signal was monitored from the directly coupled transition at 396.15 nm. Emission signal features of Al I are significantly enhanced by resonant excitation. In addition, LIF of filament ablation plumes reduces the self-reversal features seen in the thermally excited spectral profiles. Time-resolved two-dimensional fluorescence spectroscopy was performed for evaluating the optical saturation effects, which are found to be non-negligible due to high Al atomic densities in the filament-produced plasmas.

47 OTHER INSTRUMENTATION↗

Collective optical Thomson scattering in pulsed-power driven high energy density physics experiments (invited)

Optical collective Thomson scattering is used to diagnose magnetized high energy density physics experiments at the Magpie pulsed-power generator at Imperial College London. The system uses an amplified pulse from the 2nd harmonic of a Nd:YAG laser (3 J, 8 ns, 532 nm) to probe a wide diversity of hightemperature plasma objects; with densities in the range of 10 17 -10 19 cm -3 and temperatures between 10 eV and a few keV. The scattered light is collected from 100 μm-scale volumes within the plasmas, which are imaged onto optical fiber arrays. Multiple collection systems observe these volumes from different directions, providing simultaneous probing with different scattering K-vectors (and different associated α-parameters, typically in the range 0.5 – 3) allowing independent measurements of separate velocity components of the bulk plasma flow. The fiber arrays are coupled to an imaging spectrometer with a gated ICCD. The spectrometer is configured to view the ion-acoustic waves (IAWs) of the collective Thomson scattered spectrum. Fits to the spectra with the theoretical spectral density function S(K,ω) yield measurements of the local plasma temperatures and velocities. Fitting is constrained by independent measurements of the electron density from laser interferometry, and the corresponding spectra for different scattering vectors. Furthermore, this TS diagnostic has been successfully implemented on a wide range of experiments, revealing temperature and flow velocity transitions across magnetized shocks, inside rotating plasma jets and imploding wire arrays, as well as providing direct measurements of drift velocities inside a magnetic reconnection current sheet.

47 OTHER INSTRUMENTATION↗