The observed eigenfrequency of the Chandler wobble
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
X Persei is a persistent low-luminosity X-ray pulsar of period of ≈ 835 s in a Be binary system. The field strength at the neutron star surface is not known precisely, but indirect signs indicate a magnetic field above 10 13 G, which makes the object one of the most magnetized known X-ray pulsars. Here we present the results of observations X Persei performed with the Imaging X-ray Polarimetry Explorer (IXPE). The X-ray polarization signal was found to be strongly dependent on the spin phase of the pulsar. The energy-averaged polarization degree in 3–8 keV band varied from several to ∼20 per cent over the pulse with a phase dependence resembling the pulse profile. The polarization angle shows significant variation and makes two complete revolutions during the pulse period, resulting in nearly nil pulse-phase averaged polarization. Applying the rotating vector model to the IXPE data we obtain the estimates for the rotation axis inclination and its position angle on the sky, as well as for the magnetic obliquity. The derived inclination is close to the orbital inclination, reported earlier for X Persei. The polarimetric data imply a large angle between the rotation and magnetic dipole axes, which is similar to the result reported recently for the X-ray pulsar GRO J1008−57. After eliminating the effect of polarization angle rotation over the pulsar phase using the best-fitting rotating vector model, the strong dependence of the polarization degree with energy was discovered, with its value increasing from 0 at ∼2 keV to 30per cent at 8 keV.
Observation is reported of a rotation in the polarization of the two photorefractive recording beams in GaAs for a configuration with the internally generated space-charge field along the line 110 crystallographic orientation. This rotation is a result of simultaneous constructive and destructive beam coupling in each beam for the optical electric field components along the two electrooptically induced principal dielectric axes of the crystal. By turning one of the beams on and off, the intensity of the other beam after the crystal and a polarization analyzer can be modulated by as much as 500 percent. This result is of particular importance for optical information processing applications.
As a roving vehicle moves along the lunar surface, electric charge will build up through tribo-charging. This charge collected by the roving object will have a dissipative path to either the surface or the ambient plasma, depending upon which path is most conductive. At the lunar terminator region and into nightside regions, the surface is very cold and becomes a very poor conductor. leaving the plasma as the dominant remediating current for dissipation. However, within lunar craters, even plasma currents become substantially reduced which then greatly increases electric 'dissipation times, This work will involve the advancement of the stepping astronaut charge model, by considering the charging and plasma dissipation of a rolling rover wheel, The objective of this work is to determine the nature of charging and discharging for a rover wheel as it rolls along the cold, plasma-starved lunar polar regions. The rotating wheel accumulates charge via contact electrification (tribo-charging) with the lunar regolith. This tribo-charging is dependent on the composition of the objects in contact, with insulators and conductors charging differently. Given the environmental plasma in the region, we then determine the dissipation time for the wheel to bleed off its excess charge into the surrounding plasma. A model of the rover wheel rotating continuously over a surface regolith within a polar crater has been applied. The environmental plasma has been described previously. We define a new tribo-charging term specifically for the rotating system, with charge levels defined as a function of the wheel size, area in contact with the regolith, regolith particle size distribution, as well as the velocity at which the wheel is turning. We recognize that as charged dust accumulates and sticks to the wheel, this behaves effectively as a new current. Hence, the overall charging of the system should no longer vary linearly. and begin to show signs of saturation, We are devising a dust current term to model this charge-limiting effect, and will present the results in discussion.
Experiments that require linearly polarized brightness measurements, traditionally have obtained three successive images through a linear polarizer that is rotated through three well-defined angles and the images are combined to get the linearly polarized brightness. This technique requires a mechanism to hold the linear polarizer in place and to precisely turn it through the three angles. Obviously, the temporal resolution is lost in such a scenario, since the three images that are used to derive the linearly polarized brightness are taken at three different times. Specifically, in a dynamic corona that is in constant reshaping of its structures, the linearly polarized brightness image produced in this manner may not yield true values all around the corona. In this regard, with the advent of the polarization camera, the linearly polarized brightness can be measured from a single image. This also eliminates the need for a linear polarizer and the associated rotator mechanisms and can contribute toward lower weight, size, power requirements, overall risk of the instrument, and most importantly, increase the temporal resolution. We evaluate the capabilities of a selected polarization camera and how these capabilities could be tested in a ground experiment conducted in conjunction with a total solar eclipse. The ground experiment requires the measurement of the linearly polarized brightness, also known as K-corona, in a corona that also contains unpolarized brightness, known as F-corona, in order to measure three important physical properties pertaining to coronal electrons, namely, the electron density, electron temperature, and the electron speed.
An electrostrictive graft elastomer has a backbone molecule which is a non-crystallizable, flexible macromolecular chain and a grafted polymer forming polar graft moieties with backbone molecules. The polar graft moieties have been rotated by an applied electric field, e.g., into substantial polar alignment. The rotation is sustained until the electric field is removed. In another embodiment, a process for producing strain in an elastomer includes: (a) providing a graft elastomer having a backbone molecule which is a non-crystallizable, flexible macromolecular chain and a grafted polymer forming polar graft moieties with backbone molecules; and (b) applying an electric field to the graft elastomer to rotate the polar graft moieties, e.g., into substantial polar alignment.
The phenomenon of Faraday rotation of linearly polarized synchrotron emission in a magneto-ionized medium has been understood and studied for decades. But since the sense of the rotation itself is irrelevant in most contexts, some uncertainty and inconsistencies have arisen in the literature about this detail. Here, we start from basic plasma theory to describe the propagation of polarized emission from a background radio source through a magnetized, ionized medium in order to rederive the correct sense of Faraday rotation. We present simple graphics to illustrate the decomposition of a linearly polarized wave into right and left circularly polarized modes, the temporal and spatial propagation of the phases of those modes, and the resulting physical rotation of the polarization orientation. We then re-examine the case of a medium that both Faraday-rotates and emits polarized radiation and show how a helical magnetic field can construct or destruct the Faraday rotation. This paper aims to resolve a source of confusion that has arisen between the plasma physics and radio astronomy communities and to help avoid common pitfalls when working with this unintuitive phenomenon.
Sudden approximation applied to computation of rotational transition probability and inelastic total cross sections for scattering of polar and nonpolar diatomic molecules by atoms
A system for monitoring the configuration of a surface (e.g., a segmented parabolic surface) using orthogonally placed retroreflectors at sets of points 1, 2, and 3 dispersed throughout the surface with a stationary halfwave plate (HWP) in the front of the one retroreflector at a corner point 3 and a rotating halfwave plate (RHWP) over a source of linearly polarized coherent light, thereby causing the direction of linear polarization to continuously rotate through 360 deg and causing light returned by the retroreflector at point 3 to be continuously phase shifted through 360 deg relative to light returned by retroreflectors at points 1 and 2. The returned light from each set of points 1, 2, and 3 is focused onto a bed-of-nails (BON) phase grating diagonally oriented with respect to the orthogonal orientation of the incident beams from retroreflectors 1, 2, and 3, thereby causing overlap in the light from points 1 and 3 to produce interferometric signals 1,3 and 2,3. Any change in phase of the interferometric signals 1,3 and 2,3 indicates both the magnitude and direction of any change in the position of the retroreflector at point 3 relative to retroreflectors at points 1 and 2.
Sudden changes in earth rotational acceleration and polar secular motion
We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman‐alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman‐alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non‐uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.
The contributions of the Antarctic and the Greenland ice sheets to the earth's gravity, displacement, and rotation are estimated using gridded values of the net surface accumulation rates in the ice sheets of these two regions. It is found that the contributions to the low-order zonal harmonic coefficients of the earth's gravitational potential from Antarctica are between 2 and 10 times larger than the uncertainties of the zonal harmonics derived from satellite solutions; for Greenland, the coefficients are within an order of magnitude of the uncertainties of the satellite solutions. Polar contributions to the displacement of the center of mass of the solid earth, as seen in the frame of reference of satellites tracked from the earth surface, range from less than 1 mm to 1.5 cm over a 60-yr period.
Compact polarimetry has been shown to be an interesting alternative mode to full polarimetry when global coverage and revisit time are key issues. It consists on transmitting a single polarization, while receiving on two. Several critical points have been identified, one being the Faraday rotation (FR) correction and the other the calibration. When a low frequency electromagnetic wave travels through the ionosphere, it undergoes a rotation of the polarization plane about the radar line of sight for a linearly polarized wave, and a simple phase shift for a circularly polarized wave. In a low frequency radar, the only possible choice of the transmit polarization is the circular one, in order to guaranty that the scattering element on the ground is illuminated with a constant polarization independently of the ionosphere state. This will allow meaningful time series analysis, interferometry as long as the Faraday rotation effect is corrected for the return path. In full-polarimetric (FP) mode, two techniques allow to estimate the FR: Freeman method using linearly polarized data, and Bickel and Bates theory based on the transformation of the measured scattering matrix to a circular basis. In CP mode, an alternate procedure is presented which relies on the bare surface scattering properties. These bare surfaces are selected by the conformity coefficient, invariant with FR. This coefficient is compared to other published classifications to show its potential in distinguishing three different scattering types: surface, doublebounce and volume. The performances of the bare surfaces selection and FR estimation are evaluated on PALSAR and airborne data. Once the bare surfaces are selected and Faraday angle estimated over them, the correction can be applied over the whole scene. The algorithm is compared with both FP techniques. In the last part of the paper, the calibration of a CP system from the point of view of classical matrix transformation methods in polarimetry is proposed.
Explore the source record for details and available documents.
Cir X-1 is a neutron star X-ray binary characterized by strong variations influx during its eccentric∼16.6 day orbit. There are also strong variations in the spectral state, and it has historically shown both atoll and Z state properties. We observed the source with the Imaging X-ray Polarimetry Explorer during two orbital segments, 6days apart, for a total of 263 ks. We find an X-ray polarization degree in these segments of 1.6%±0.3% and1.4%±0.3% at polarization angles of 37°±5°and−12°±7°, respectively. Thus, we observed a rotation of the polarization angle by 49°±8°along the orbit. Because variations of accretion flow, and then of the hardness ratio, are expected during the orbit, we also studied the polarization binned in hardness ratio and found the polarization angle differing by 67°±11°between the lowest and highest values of the hardness ratio. We discuss possible interpretations of this result that could indicate a possible misalignment between the symmetry axes of the accretion disk and the Comptonizing region caused by the misalignment of the neutron star’s angular momentum with respect to the orbital one.
In the previous paper in this series (McGuire and Chipman, 1990), a formulation was established for the calculation and analysis of diffraction image quality in polarizing optical systems illuminated with partially polarized, partially coherent light. In the present paper, the effect of second- and fourth-order polarization aberrations on the image plane diffraction patterns are examined. The amplitude response matrix is calculated for optical systems with small numerical apertures. Numerical results are presented for optical systems with circular apertures for three of the aberration types.