Search NASA⌕ Search

SEARCH · Search NASA

Results for “power inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Studying the Impact of IBR Modeling on the Commonly Applied Transmission Line Protective Elements

It is a well-accepted fact that detailed inverter-based resource (IBR) models are needed for electromagnetic transient (EMT) studies, especially for protection studies and protection designs. However, it is not clear which modeling aspects should be included in the EMT model to accurately represent the IBR fault responses. Therefore, this paper addresses this gap by evaluating the impact of key modeling aspects (DC source, inverter model, power control, current/voltage control, and current limiting) on the response of protective relay elements both qualitatively and quantitatively. Both grid-following (GFL) and grid-forming (GFM) IBR models are comprehensively evaluated through a simplified real-world transmission network by varying the IBR modeling aspects, fault locations, and types. The insights and findings from this paper will benefit the power system protection community because this work provides modeling requirements and guidelines for IBR modeling so that correct IBR models will be used for protection scheme settings design.

grid-following inverter↗

Blackstart of Power Grids with Inverter-Based Resources: Preprint

This paper presents the findings of our investigation into inverter-based resource- (IBR-) driven blackstart of electric grids. Four potential black-start configurations with different setups are presented. To evaluate the technical feasibility of IBR-driven black start in the four configurations, a behavioral model of inverters that mimics current-limited inverter operation is developed using variable resistors in the MATLAB Simulink/Simscape environment. The inverter model is connected to an induction motor through transformers and a transmission line to simulate its startup. Simulation results show that even with the limited current supply capability of inverters because of their physical constraints, IBRs can black-start a motor under certain conditions. Results also show that by using soft-start techniques, such as ramped supply voltage, inrush currents can be reduced, thereby expanding the conditions under which IBRs can provide black-start support. Simulation results with different scenarios lead to discussions and key takeaways that could be valuable for further IBR-driven black-start research.

14 SOLAR ENERGY↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration: Preprint

This paper presents an innovative wave energy conversion system employing an interleaved Cuk converter and advanced nonlinear control for seamless integration with the grid. The proposed system utilizes the interleaved Cuk converter for efficient power extraction on the DC side, while an inverter facilitates power transfer to the grid or load on the AC side. A sophisticated nonlinear control architecture based on Lyapunov energy functions ensures stable and optimal operation under varying wave conditions. Case study results demonstrate the effectiveness of the proposed system, highlighting its ability to efficiently harness wave energy and seamlessly integrate with the grid, thus paving the way for sustainable and reliable renewable energy generation. The overall system is verified via computer simulations based on MATLAB/Simulink and various case study results are presented.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Advanced Power-Hardware-in-the-Loop Evaluation of Inverter-Based Resources (IBRs)

Power-hardware-in-the-loop evaluation of IBRs has become more and more important as it provides reliable testing results to investigate the real responses of inverters with interconnected systems. A successful laboratory PHIL testing gives confidence of the hardware system to be deployed and de-risk technology integration prior to field deployment. So far, there are two important applications for PHIL evaluation: (1) test stability and functionality of large utility inverters into the system when it interconnects to the distribution systems/microgrids; and (2) test the collective grid service that inverters can provide to the grid. For the first application, the PHIL evaluation has high requirements for the stability and accuracy of the PHIL interface as the close-loop in digital real time simulator (DRTS) should replicate the actual current and voltage dynamics in the inverter. This is challenging because of the delays, sensing errors, nonlinearities of inverters, and hardware bandwidth limitations of the elements in the HIL loop. For the second application, multiple inverters will be tested resulting in multiple PCCs, which naturally causes competing dynamics and oscillations among hardware inverters if traditional PHIL interface is used. Therefore, new PHIL interface should be developed to compromise between stability and accuracy and represent the dispatched grid services for the hardware inverters. In this presentation, we will share our latest work in developing PHIL interface in these two applications to address the two key challenges.

DERMS↗

On the Stability of Power Transmission Systems Under Persistent Inverter Attacks: A Bi-Linear Matrix Approach

We investigate the stability and robustness properties of a power transmission system under persistent deceiving attacks on inverter-interfaced energy resources. The attacks can corrupt the damping coefficients in the inverters' controllers and measurements of the frequency at the points of coupling. Leveraging tools from hybrid dynamical systems theory, we characterize a broad family of persistent (and not necessarily periodic) attacks acting on the inverters, under which the stability properties of the transmission system can be shown to not be compromised. To address potentially conservative conditions identified through conventional bounding techniques, sufficient conditions on the average activation time of the attacks are identified via Lyapunov theory, as well as the formulation and solution of a class of bilinear matrix inequalities (BMI). The results are obtained for constant and slowly time-varying loads via input-to-state stability (ISS) tools. Numerical simulations on the IEEE 39-bus test system are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Reliable, Cost-Effective Transformerless Medium-Voltage Inverter for Grid Integration of Combined Solar and Energy Storage

The goal of this project is to utilize an innovative holistic power electronic inverter design approach, which can leverage best-in-class silicon carbide (SiC) power modules, novel multi-level power electronic circuits, high frequency transformers, switching sequence based control and co-designed electro-thermal management methods, to realize a 300 kW transformerless medium-voltage (MV) inverter system. The system cost of the inverter is considered as a primary design objective alongside high power density, efficiency, low electromagnetic interference (EMI) and long lifespan. This design-oriented research activity, especially the proposed multi-objective optimization approach, will have broad impacts in holistic power electronic system design methods and in technologies that can be commercialized into a wide variety of wide bandgap power electronic applications.

14 SOLAR ENERGY↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Distributed Control of Smart Inverters for Network-level Optimization

The limitations of centralized optimization methods in managing electric power distribution systems operations have led to the distributed paradigm of computing and decision-making. Unfortunately, the existing distributed optimization algorithms are limited in their applicability to managing fast varying phenomena such as those resulting from highly variable Distributed Energy Resource (DER) generation patterns. They require a large number of communication rounds (in the order of 10 2 to 10 3 ) among the computing agents to solve one instance of the optimization problem. Related real-time distributed control methods are equally limited in their applications to power distribution systems with fast-changing DER generation; they require hundreds of rounds of communication and thus are slow in tracking the network-level optimal solutions. In this paper, we propose a novel distributed voltage controller that provides a fast-tracking of rapidly varying DER generation profiles while simultaneously converging to network-level optimal solutions within a few communication rounds. The proposed control algorithm leverages the radial topology of the system, which reduces the required communication rounds to reach the network-level optimum solution by order of magnitude. The novelty lies in carefully reducing the electrical network model from the perspective of each distributed controller and enabling appropriate data sharing among upstream and downstream nodes to achieve fast convergence. The simulation results demonstrate the effectiveness of the proposed approach in minimizing the feeder losses while maintaining the node voltage within the pre-specified limits.

voltage control, optimization, reactive power, inv↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗